Thank you for purchasing your Nature Power Monocrystalline Solar Panel. This manual contains safety and installation information for Nature Power Monocrystalline Solar Panels. Nature Power reserves the right to make changes to the product, specifications and this manual without notice. Therefore, check the website for manual updates as necessary. www.naturepowerproducts.com
Cautions
Never touch the end of output cables with your bare hands when the modules are irradiated. Handle wires
with rubber-gloved hands to avoid electric shock
Do not wear metallic jewelry when working on electrical equipment
Product should be installed and maintained by qualified personnel
Do not drop tools or other items on the glass of the solar module
Do not scratch the back film of the solar panel
Avoid exposing solar panels to partial sunlight or shadows. Partial sunlight can cause hot spots on the panel
Do not pour chemicals on module when cleaning. To clean use a damp cloth do not apply excessive
pressure to the cells
Do not expose solar module to sunlight concentrated with mirrors, lenses or similar means
Keep module away from children
Precautions when working with batteries
Never smoke or allow a spark or flame near the batteries
Batteries generate hydrogen and oxygen during charging resulting in evolution of explosive gas mixture.
Care should be taken to ventilate the battery area and follow the battery manufacturer’s recommendations
Batteries contain very corrosive diluted acid as electrolyte. Precautions should be taken to prevent contact
with skin, eyes or clothing
Use caution to reduce the risk of dropping a metal tool on the battery. It could spark or short circuit the
battery or other electrical parts and could cause an explosion
Remove metal items like rings, bracelets and watches when working with batteries. The batteries can
produce a short circuit current high enough to weld a ring or the like to metal and thus cause a severe burn
If you need to remove a battery, always remove the ground terminal from the battery first. Make sure that
all the accessories are off so that you do not cause a spark
Only use rechargeable 12 Volt batteries, ie. Sealed Lead Acid, Deep Cycle, Gel-Cell etc.
Use properly insulated tools only when making battery connections
When working with batteries please follow the battery’s manufacturer manual and precautions
Precautions when working with solar panels
With the incidence of sunlight or other light sources on all solar panels, a voltage appears at the output terminals of the solar panel turning it into a source of electricity. Do not make contact with the terminals when the panel is exposed to sunlight or other light sources. To avoid shock hazard make sure the solar panel is either turned over so the cells are not exposed to light or cover the cells with an opaque (dark) material such as paper/cloth during the installation process.
Nature Power Products
Nature Power Monocrystalline Solar Cells are manufactured in Germany by Bosch and Solar Panels are assembled in China.
Manual Printed in China
Precautions when working with Charge Controllers
If two or more solar panels are connected in series/parallel make sure that the sum of the short circuit current ratings of all panel strings does not exceed 80% of the charge controller’s current rating i.e. 8 Amps or 28 Amps.
Package Contents:
1x Solar panel with EZ connect wiring
4x Mounting Z-brackets
4x Flange Bolts
4x Lock Nuts
4x Flat Washers
1x Battery Clamps
**280 Watt Kit: Double all quantities
Required Tools (Not Included)
Wrench
Hand Drill
Pliers
Drill Bit
Installation Overview
Open the packaging and check to make sure that all parts have been received.
Arrange to have on hand the proper tools to carry out the mounting installation.
Determine the mounting location of the solar panel(s).
Mount the charge controller within 5 feet of battery or loss of current may occur.
Wire the battery to the charge controller and then the solar panel to the charge controller to ensure that
the correct polarity is observed.
Secure the solar panel to the desired location, solar panel must be within 20 feet of the battery, or loss of
current may occur.
Selecting the correct Charge Controller
Charge Controllers may be sold separately and are required for installations of solar systems arrays that are rated 12 Watts and higher. Charge Controllers help to protect the battery(s) and solar panel(s) from harmful reverse currents, battery over charging and high wattage surges, addition protections are found on larger charge controllers. Nature Power Products offers an 8 Amp Easy-to-Connect Charge Controller (60008) and a 28 Amp Digital PWM Charge Controller (60028). You may also choose to use a non-Nature Power charge controller, however, please confirm that it is a 12 Volt DC charge controller. Also installations for non-Nature Power charge controllers may not be compatible with the EZ connect cables from the monocrystalline solar panel.