National Public Seating TPR72, RT4LC, SST48C, RS16C, STP16 User Manual

...
National Public
SEATING Corp.
sTages and risers
Shown NPS Seated Risers
www.nationalpublicseating.com
www.nationalpublicseating.com
speCiFiCaTions
National Public
SEATING Corp.
STAGES AND RISERS
Platform
Constructed with a ¾" thick solid plywood core, the riser shall be surfaced with one of the following:
Option 1: Carpet
Option 2: 1/8" thick tempered hardboard
The edges of the platform shall be routed to allow the frame to fit flush with the top surface and cover the ends of the carpet­ing.
Frame
16 gauge, 1-13/16" high formed steel channel frame shall be reinforced with 16 gauge steel angle welded to the inside of the channel. The angle shall provide a continu­ous support to which the decking is secured with screws placed a maximum of 9" apart. The frame shall completely enclose the top, bottom and edges of the decking perimeter preventing the decking from becoming loose and damaged. All areas where frame parts are joined together shall be reinforce with steel plates attached with rivets.
Leg Structure
Each leg structure shall be constructed if 1.05" diameter, 14 gauge steel tubing capped at the point of floor contact with high impact plastic glides. The vertical load bearing members shall be joined at the top by full width, steel tube to provide maximum support to the stage deck. The top of each leg assembly shall fold open and closed, using 16 gauge steel saddle clips that are secured with at least four screws. Leg assemblies shall be braced by friction type braces, equipped with a spring locking device to secure the legs in the open and closed position. Braces shall be secured to the leg assembly with rivets and to the deck using 8 screws installed through the decking. Legs shall open and close using only one hand. Gravity ring type brace locks are not acceptable.
Ganging
Stages and risers shall be equipped with drop-in couplings that allow units of the same or different heights to be joined
together. All ganging devices shall be permanently secured to each unit. Ganging devices that is not permanently attached are not acceptable.
Finish
All metal parts are to be finished with a black thermofused epoxy powdercoating.
Capacity All metal parts shall be designed to carry a uniform live load of at least 200 lbs. per square foot.
Portability
Stages and risers shall be capable of being completely set-up and taken apart quickly, without the need for tools, by two people of average strength.
Warranty
Stages and risers shall be covered by 10­year warranty.
ManUFaCTUrer's
WarranTY
TRANS-PORT
General
Risers shall consist of three 18" wide levels, 8", 16" and 24" high that are per­manently joined with hinge mechanisms to enable the unit to open and close in a uni­fied fashion. Each unit shall be equipped with wheels for easy transportation when folded and to allow for easy positioning after the unit has been set up.
Frame
Riser levels shall be supported by a 3" deep, double walled, extruded anodized aluminum frame that overlaps the top of each level to protect the carpet edge. 2 screws and lock nuts per bracket shall be used to secure hinge to frame. Frames must be joined with welded 5/16" bolt hinge.
Platform
Riser platforms shall be constructed of ¾" thick plywood, surfaced with polyolefin carpet.
SOLD THRU
Foldability
Risers shall be easily foldable and shall be easy to transport form place to place by an adult of average strength.
Ganging
Risers shall easily attach to each other without lifting unit by connecting ganging cord onto latch underneath the adjoining riser.
Optional Guardrails
Guardrails shall be constructed of black epoxy powdercoated tubular steel and shall be equipped with clamp-on attach­ments for easy installation. Guardrail must attach to unit using bolt.
Warranty
Trans-port risers shall be covered by 5­year warranty.
National Public Seating Corp. offers the original user a warranty against all manufacturing defects in material and workmanship. If defective, NPS will, at its option, repair or replace the defective product. This warranty does not apply to damage resulting from misuse, abuse or neglect. Authorization for return and/or repairs is required by contacting your dealer. This warranty gives you specific rights, and you may also have other rights which vary from state to state.
Orders are accepted under the express agreement that under no circumstances will seller be liable for any incidental or consequential damages, or for any other loss, damage or expense of any kind, including loss of profits, arising in connection with the order or with the use or inability to use seller’s products furnished under the order. Seller’s maximum liability shall not exceed and buyer’s remedy is limited to either (i) repair or replacement of the defective part or product, or at seller’s option, (ii) return of the product and refund of the purchase price. Such remedy shall be the buyer’s entire and exclusive remedy.
NATIONAL PUBLIC SEATING | 149 Entin Road, Clifton NJ 07014 | 973-594-1100 | www.nationalpublicseating.com
Loading...
+ 4 hidden pages