USER GUIDE AND SPECIFICATIONS
NI USB-9211/9211A
4-Channel, 24-Bit Thermocouple Input Devices
This user guide describes how to use the National Instruments USB-9211/9211A devices and lists the specifications.
Introduction
The NI USB-9211/9211A data acquisition device provides a USB interface for four channels of 24-bit thermocouple inputs with integrated signal conditioning.
The NI USB-9211 consists of two components: an NI 9211 module and an NI USB-9161 carrier, as shown in Figure 1. The NI USB-9211A consists of two components: an NI 9211 module and an NI USB-9162 carrier, as shown in Figure 1.
NI 9211
NI USB-9161/9162
Figure 1. NI USB-9211/9211A Components
NI USB-9211/9211A
Dimensions
Figure 2 shows the NI USB-9211/9211A device dimensions.
Hi-Speed USB Carrier
NI USB-9162
140.23 mm (5.521 in.)
137.82 mm (5.426 in.)
120.68 mm (4.751 in.)
Safety Guidelines
Operate the NI USB-9211/9211A only as described in these operating instructions.
118.26 mm (4.656 in.)
88.12 mm (3.469 in.)
Figure 2. NI USB-9211/9211A Device in Millimeters (Inches)
25.34 mm (0.998 in.)
Note Although the NI 9211 module may have more stringent certification standards than
the NI USB-9211/9211A, when used with the NI USB-9161/9162 carrier, the combined system may be limited. Refer to the Specifications section for more details.
Hot Surface This icon denotes that the component may be hot. Touching this component
may result in bodily injury.
Caution Do not disconnect I/O-side wires or connectors unless power has been switched
off or the area is known to be nonhazardous.
Caution Do not remove modules unless power has been switched off or the area is known
to be nonhazardous.
Caution The NI USB-9211/9211A is not certified for use in hazardous locations.
NI USB-9211/9211A User Guide and Specifications 2 ni.com
Safety Guidelines for Hazardous Voltages
If hazardous voltages are connected to the module, take the following precautions. A hazardous voltage is a voltage greater than 42.4 V 60 VDC to earth ground.
Caution Ensure that hazardous voltage wiring is performed only by qualified personnel
adhering to local electrical standards.
Caution Do not mix hazardous voltage circuits and human-accessible circuits on the same
module.
Caution Make sure that devices and circuits connected to the module are properly
insulated from human contact.
Caution When module terminals are live with hazardous voltages, make sure that the
terminals are not accessible by using the high voltage screw terminal enclosure. Refer to the Assembling the High Voltage Screw Terminal Backshell section for more information.
Related Documentation
pk
or
Each application software package and driver includes information about writing applications for taking measurements and controlling measurement devices. The following references to documents assume you have NI-DAQmx 8.7 or later, NI-DAQmx Base 3.x, and where applicable, version 7.1 or later of the NI application software.
NI-DAQmx for Windows
The DAQ Getting Started Guide describes how to install your NI-DAQmx for Windows software, how to install your NI-DAQmx-supported DAQ device, and how to confirm that your device is operating properly. Select
Start»All Programs»National Instruments»NI-DAQ»DAQ Getting Started Guide.
The NI-DAQ Readme lists which devices are supported by this version of NI-DAQ. Select Start»All Programs»National Instruments»NI-DAQ» NI-DAQ Readme.
The NI-DAQmx Help contains general information about measurement concepts, key NI-DAQmx concepts, and common applications that are applicable to all programming environments. Select Start» All Programs»National Instruments»NI-DAQ»NI-DAQmx Help.
Note For information about non-Windows operating system support, refer to
ni.com/info and enter BaseGSGML.
© National Instruments Corporation 3 NI USB-9211/9211A User Guide and Specifications
LabVIEW
If you are a new user, use the Getting Started with LabVIEW manual to familiarize yourself with the LabVIEW graphical programming environment and the basic LabVIEW features you use to build data acquisition and instrument control applications. Open the Getting Started
with LabVIEW manual by selecting Start»All Programs»National Instruments»LabVIEW»LabVIEW Manuals or by navigating to the
labview\manuals directory and opening LV_Getting_Started.pdf.
Use the LabVIEW Help, available by selecting Help»Search the LabVIEW Help in LabVIEW, to access information about LabVIEW
programming concepts, step-by-step instructions for using LabVIEW, and reference information about LabVIEW VIs, functions, palettes, menus, and tools. Refer to the following locations on the Contents tab of the LabVIEW Help for information about NI-DAQmx:
Getting Started»Getting Started with DAQ—Includes overview
information and a tutorial to learn how to take an NI-DAQmx measurement in LabVIEW using the DAQ Assistant.
VI and Function Reference»Measurement I/O VIs and Functions—Describes the LabVIEW NI-DAQmx VIs and properties.
Taking Measurements—Contains the conceptual and how-to
LabWindows/CVI
The Data Acquisition book of the LabWindows/CVI Help contains measurement concepts for NI-DAQmx. This book also contains Taking an NI-DAQmx Measurement in LabWindows/CVI, which includes step-by-step instructions about creating a measurement task using the DAQ Assistant. In LabWindows Using LabWindows/CVI»Data Acquisition.
The NI-DAQmx Library book of the LabWindows/CVI Help contains API overviews and function reference for NI-DAQmx. Select Library Reference»NI-DAQmx Library in the LabWindows/CVI Help.
Measurement Studio
If you program your NI-DAQmx-supported device in Measurement Studio using Visual C++, Visual C#, or Visual Basic .NET, you can interactively create channels and tasks by launching the DAQ Assistant from MAX or from within Visual Studio .NET. You can generate the configuration code
information you need to acquire and analyze measurement data in LabVIEW, including common measurements, measurement fundamentals, NI-DAQmx key concepts, and device considerations.
/CVI™, select Help»Contents, then select
NI USB-9211/9211A User Guide and Specifications 4 ni.com
based on your task or channel in Measurement Studio. Refer to the DAQ Assistant Help for additional information about generating code. You also
can create channels and tasks, and write your own applications in your ADE using the NI-DAQmx API.
For help with NI-DAQmx methods and properties, refer to the NI-DAQmx .NET Class Library or the NI-DAQmx Visual C++ Class Library included in the NI Measurement Studio Help. For general help with programming in Measurement Studio, refer to the NI Measurement Studio Help, which is fully integrated with the Microsoft Visual Studio .NET help. To view this help file in Visual Studio. NET, select Measurement Studio» NI Measurement Studio Help.
To create an application in Visual C++, Visual C#, or Visual Basic .NET, follow these general steps:
1. In Visual Studio .NET, select File»New»Project to launch the New
Project dialog box.
2. Find the Measurement Studio folder for the language you want to create a program in.
3. Choose a project type. You add DAQ tasks as a part of this step.
ANSI C without NI Application Software
The NI-DAQmx Help contains API overviews and general information about measurement concepts. Select Start»All Programs»National Instruments»NI-DAQ»NI-DAQmx Help.
The NI-DAQmx C Reference Help describes the NI-DAQmx Library functions, which you can use with National Instruments data acquisition devices to develop instrumentation, acquisition, and control applications. Select Start»All Programs»National Instruments»NI-DAQ» NI-DAQmx C Reference Help.
.NET Languages without NI Application Software
With the Microsoft .NET Framework version 1.1 or later, you can use NI-DAQmx to create applications using Visual C# and Visual Basic .NET without Measurement Studio. You need Microsoft Visual Studio .NET 2003 or Microsoft Visual Studio 2005 for the API documentation to be installed.
The installed documentation contains the NI-DAQmx API overview, measurement tasks and concepts, and function reference. This help is fully integrated into the Visual Studio .NET documentation. To view the NI-DAQmx .NET documentation, go to Start»Programs»National
Instruments»NI-DAQ»NI-DAQmx .NET Reference Help. Expand NI Measurement Studio Help»NI Measurement Studio .NET Class
© National Instruments Corporation 5 NI USB-9211/9211A User Guide and Specifications
Library»Reference to view the function reference. Expand NI Measurement Studio Help»NI Measurement Studio .NET Class Library»Using the Measurement Studio .NET Class Libraries to view
conceptual topics for using NI-DAQmx with Visual C# and Visual Basic .NET.
To get to the same help topics from within Visual Studio, go to Help» Contents. Select Measurement Studio from the Filtered By drop-down list and follow the previous instructions.
Device Documentation and Specifications
NI-DAQmx includes the Device Document Browser, which contains online documentation for supported DAQ and SCXI devices, such as documents describing device pinouts, features, and operation. You can find, view, and/or print the documents for each device using the Device Document Browser at any time by inserting the CD. After installing the Device Document Browser, device documents are accessible from Start»
All Programs»National Instruments»NI-DAQ»Browse Device Documentation.
Note You can download these documents at ni.com/manuals.
NI-DAQmx Base (Linux/Mac OS X/LabVIEW PDA 8.x )
The NI-DAQmx Base Getting Started Guide describes how to install your NI-DAQmx Base software, your NI-DAQmx Base-supported DAQ device, and how to confirm that your device is operating properly. In Windows, select Start»All Programs»National Instruments»NI-DAQmx Base» Documentation»Getting Started Guide.
Getting Started with NI-DAQmx Base for Linux and Mac Users describes how to install your NI-DAQmx Base software, your NI-DAQmx Base-supported DAQ device, and how to confirm that your device is operating properly on your Mac/Linux machine.
The NI-DAQmx Base Readme lists which devices are supported by this version of NI-DAQmx Base. In Windows, select Start»All Programs» National Instruments»NI-DAQmx Base»DAQmx Base Readme.
The NI-DAQmx Base VI Reference Help contains VI reference and general information about measurement concepts. In LabVIEW, select Help» NI-DAQmx Base VI Reference Help.
The NI-DAQmx Base C Reference Help contains C reference and general information about measurement concepts. In Windows, select Start»
All Programs»National Instruments»NI-DAQmx
NI USB-9211/9211A User Guide and Specifications 6 ni.com
Base»Documentation» C Function Reference Help.
Note All NI-DAQmx Base documentation for Linux is installed at /usr/local/
natinst/nidaqmxbase/documentation
Note All NI-DAQmx Base documentation for Mac OS X is installed at /Applications/
National Instruments/NI-DAQmx Base/documentation
Training Courses
If you need more help getting started developing an application with NI products, NI offers training courses. To enroll in a course or obtain a detailed course outline, refer to
Technical Support on the Web
For additional support, refer to ni.com/support or zone.ni.com.
Installing the Software
.
.
ni.com/training.
Software support for the NI USB-9211/9211A for Windows Vista/XP/2000 is provided by NI-DAQmx or NI-DAQmx Base depending on the software you are using. Software support for your hardware depends on the carrier being used. Refer to Table 1 for a list of software support.
Table 1. Devices and Corresponding Components
Device Carrier Software Support
NI USB-9211 NI USB-9161 NI-DAQmx Base 2.2 and previous
NI USB-9211A NI USB-9162 NI-DAQmx or NI-DAQmx Base 3.0 and later
The DAQ Getting Started Guide, which you can download at
manuals
software and hardware, configuring channels and tasks, and getting started developing an application.
Note For information about non-Windows operating system support, refer to ni.com/
info
and enter BaseGSGML.
, offers NI-DAQmx users step-by-step instructions for installing
ni.com/
© National Instruments Corporation 7 NI USB-9211/9211A User Guide and Specifications
Loading...
+ 17 hidden pages