This document explains how to connect the SLSC-12201.
Note Before you begin, complete the software and hardware installation
procedures applicable to your application.
Note The guidelines in this document are specific to the SLSC-12201. The other
components in the system might not meet the same safety ratings. Refer to the
documentation of each component in the system to determine the safety and EMC
ratings for the entire system.
Safety Guidelines
Caution Observe all instructions and cautions in the user documentation. Using
the model in a manner not specified can damage the model and compromise the
built-in safety protection. Return damaged models to NI for repair.
Attention Suivez toutes les instructions et respectez toutes les mises en garde de la
documentation utilisateur. L'utilisation d'un modèle de toute autre façon que celle
spécifiée risque de l'endommager et de compromettre la protection de sécurité
intégrée. Renvoyez les modèles endommagés à NI pour réparation.
Safety Voltages
Measurement categoryO
Isolation
Channel-to-channelNone
Channel-to-earth groundNone
Caution Do not connect the SLSC-12201 to signals or use for measurements
within Measurement Categories II, III, or IV.
Attention Ne connectez pas le SLSC-12201 à des signaux et ne l'utilisez pas pour
effectuer des mesures dans les catégories de mesure II, III ou IV.
Measurement Category I is for measurements performed on circuits not directly connected to
the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live
electrical supply system that powers equipment. This category is for measurements of voltages
from specially protected secondary circuits. Such voltage measurements include signal levels,
special equipment, limited-energy parts of equipment, circuits powered by regulated lowvoltage sources, and electronics.
Note Measurement Categories CAT I and CAT O are equivalent. These test and
measurement circuits are for other circuits not intended for direct connection to the
MAINS building installations of Measurement Categories CAT II, CAT III, or
CAT IV.
EMC Guidelines
This product was tested and complies with the regulatory requirements and limits for
electromagnetic compatibility (EMC) stated in the product specifications. These requirements
and limits provide reasonable protection against harmful interference when the product is
operated in the intended operational electromagnetic environment.
2 | ni.com | SLSC-12201 Getting Started Guide
This product is intended for use in industrial locations. However, harmful interference may
occur in some installations, when the product is connected to a peripheral device or test object,
or if the product is used in residential or commercial areas. To minimize interference with
radio and television reception and prevent unacceptable performance degradation, install and
use this product in strict accordance with the instructions in the product documentation.
Furthermore, any changes or modifications to the product not expressly approved by National
Instruments could void your authority to operate it under your local regulatory rules.
Notice To ensure the specified EMC performance, operate this product only with
shielded cables and accessories.
Notice To ensure the specified EMC performance, the length of all I/O cables must
be no longer than 3 m (10 ft).
Preparing the Environment
Ensure that the environment in which you are using the SLSC-12201 meets the following
specifications.
Module operating temperature
0 °C to 85 °C
(IEC 60068-2-1, IEC 60068-2-2)
Operating humidity (IEC 60068-2-78)10% RH to 90% RH, noncondensing
Pollution Degree2
Maximum altitude2,000 m
1
Indoor use only.
Note Refer to the device specifications on ni.com/manuals for complete
specifications.
1
The chassis internal ambient temperature may reach 85 °C with all slots at the maximum allowed
power dissipation.
Vsup_<0, 1> Voltage supply connection for Bank 0 and Bank 1. You can select either for a
given bank.
GNDGround connection
NCNo connection
Connecting Digital Devices to the SLSC-12201
The SLSC-12201 has 32 digital input/output channels that allow the direction to be configured
for each channel. The 32 channels are organized into two banks of 16 channels each. Each
bank can be powered from either of the Vsup connections. The banks are further organized
into two ports of eight channels each. In the example shown below, the SLSC-12201 connects
to the PXIe-7821R through the RTI-12301.
Short-Circuit Protection
Digital output channels are protected against short-circuit faults.
8 | ni.com | SLSC-12201 Getting Started Guide
Note The SLSC-12201 supports up to 10 channels in simultaneous short-circuit
fault.
Worldwide Support and Services
The NI website is your complete resource for technical support. At ni.com/support, you have
access to everything from troubleshooting and application development self-help resources to
email and phone assistance from NI Application Engineers.
Visit ni.com/services for information about the services NI offers.
Visit ni.com/register to register your NI product. Product registration facilitates technical
support and ensures that you receive important information updates from NI.
NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas,
78759-3504. NI also has offices located around the world. For support in the United States,
create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For
support outside the United States, visit the Worldwide Offices section of ni.com/niglobal to
access the branch office websites, which provide up-to-date contact information.
Information is subject to change without notice. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for
information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their
respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your
software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find
information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer
to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how
to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS
TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S.
Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable
limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.