National Instruments PXIe-5160, PXIe-5162, PXIe-5163 Getting Started Manual

GETTING STARTED GUIDE
PXIe-5160/5162
PXIe, 500 MHz or 1.5 GHz, 2.5 GS/s or 5 GS/s, 10-Bit PXI Oscilloscopes
Note Before you begin, install and configure your chassis and controller.
This document explains how to install, configure, and test the PXIe-5160/5162. The PXIe-5160 is a 500 MHz, 10-bit oscilloscope with a sample rate of up to 2.5 GS/s. The PXIe-5162 is a 1.5 GHz, 10-bit oscilloscope with a sample rate of up to 5 GS/s.
Documentation for the PXIe-5160/5162 is available from the Start menu by navigating to NI-SCOPE Documentation in the National Instruments folder.
Contents
Verifying the System Requirements..........................................................................................2
Unpacking the Kit..................................................................................................................... 2
Other Equipment....................................................................................................................... 3
Preparing the Environment....................................................................................................... 4
Installing the Software.............................................................................................................. 4
Installing the PXIe-5160/5162.................................................................................................. 5
PXIe-5160/5162 Front Panels...................................................................................................7
Configuring the PXIe-5160/5162 in MAX............................................................................... 8
PXIe-5160/5162 Self-Calibration............................................................................................. 9
Running Self-Calibration.................................................................................................. 9
First Measurements................................................................................................................. 10
Making a Measurement with InstrumentStudio..............................................................10
Making a Measurement with LabVIEW.........................................................................10
PXIe-5160/5162 Compensating Passive Probes............................................................. 11
Programming the PXIe-5160/5162......................................................................................... 13
NI-SCOPE Examples......................................................................................................15
Troubleshooting...................................................................................................................... 16
What Should I Do if the PXIe-5160/5162 Doesn't Appear in MAX?............................ 16
What Should I Do if the PXIe-5160/5162 Fails the Self-Test?.......................................16
Thermal Shutdown Error................................................................................................ 17
Where To Go Next.................................................................................................................. 17
Worldwide Support and Services............................................................................................18
Verifying the System Requirements
To use the NI-SCOPE instrument driver, your system must meet certain requirements.
Refer to the product readme, which is available on the driver software media or online at
ni.com/manuals, for more information about minimum system requirements, recommended
system, and supported application development environments (ADEs).
Unpacking the Kit
Refer to the following figure to identify the contents of the PXIe-5160/5162 kit.
1
42
3
1. PXIe-5160 or PXIe-5162
2. PXIe-5160 or PXIe-5162 Safety, Environmental, and Regulatory Information
3. PXIe-5160/5162 Getting Started Guide (this document)
4. Maintain Forced-Air Cooling Note to Users
Notice To prevent electrostatic discharge (ESD) from damaging the module,
ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis.
1. Touch the antistatic package to a metal part of the computer chassis.
2. Remove the module from the package and inspect it for loose components or other signs of damage.
Notice Never touch the exposed pins of connectors.
Note Do not install a module if it appears damaged in any way.
3. Unpack any other items and documentation from the kit.
Store the module in the antistatic package when the module is not in use.
2 | ni.com | PXIe-5160/5162 Getting Started Guide
Other Equipment
There are several required items not included in your device kit that you need to operate the PXIe-5160/5162. Your application may require additional items not included in your kit to install or operate your device.
Required Items
A PXI Express chassis and chassis documentation
A PXI Controller or PC with a Device for PXI Remote Control system that meets the system requirements specified in this guide and chassis documentation
Optional Items
PXI Slot Blocker Kit, 5 slot blockers (NI part number 199198-01)
PXI Filler Panel Kit, 17 filler panels (NI part number 778646-01)
BNC-to-BNC cable, 50 Ω, 1 m (NI part number 781887-01)
Oscilloscope probe compensator, SMB (NI part number 786983-01)
Probes—refer to the following table for several options compatible with the PXIe-5160/5162.
Table 1. Probe Options for the PXIe-5160/5162
Model NI Part Number Description
CP400X 784254-01 400 MHz, 2 m, 10X cable divider probe
CP500X 784253-01 500 MHz, 1.2 m, 10X cable divider probe
NI 5191 781785-01 800 MHz differential active probe
SA1000X 784255-01 1 GHz single-ended active probe
SA1500X 784256-01 1.5 GHz single-ended active probe
SA2500X 784257-01 2.5 GHz single-ended active probe
SP200B 780284-01 1x or 10x passive probe, 200 MHz
SP500C 783630-01 100x passive probe, 500 MHz
SP500X 783629-01 10x passive probe, 500 MHz
CC0550X 786846-01 5 A RMS, 50 MHz current probe
CC05120X 786847-01 5 A RMS, 120 MHz current probe
CC5002X 786848-01 500 A RMS, 2 MHz current probe
CC15010X 786849-01 150 A RMS, 10 MHz current probe
PXIe-5160/5162 Getting Started Guide | © National Instruments | 3
Table 1. Probe Options for the PXIe-5160/5162 (Continued)
Model NI Part Number Description
CC3050X 785561-01 30 A RMS, 50 MHz current probe
CC30100X 785562-01 30 A RMS, 100 MHz current probe
Visit ni.com for more information about these additional items.
Preparing the Environment
Ensure that the environment in which you are using the PXIe-5160/5162 meets the following specifications.
Temperature
Operating 0 °C to 45 °C
Storage -40 °C to 71 °C
Humidity
Operating 10% to 90%, noncondensing
Storage 5% to 95%, noncondensing
Pollution Degree 2
Maximum altitude 2,000 m (800 mbar) (at 25 °C ambient temperature)
Indoor use only.
Installing the Software
You must be an Administrator to install NI software on your computer.
1. Install an ADE, such as LabVIEW or LabWindows™/CVI™.
2. Visit ni.com/downloads/drivers and search for NI-SCOPE.
3. Download the latest version of NI-SCOPE, extract the downloaded files, and run the executable (.exe) file.
Driver support for the PXIe-5160/5162 was first available in NI-SCOPE 4.1.
4. Follow the instructions in the installation prompts.
Note Windows users may see access and security messages during
installation. Accept the prompts to complete the installation.
5. When the installer completes, select Restart in the dialog box that prompts you to restart, shut down, or restart later.
4 | ni.com | PXIe-5160/5162 Getting Started Guide
Installing the PXIe-5160/5162
Notice To prevent damage to the PXIe-5160/5162 caused by ESD or
contamination, handle the module using the edges or the metal bracket.
1. Ensure the AC power source is connected to the chassis before installing the module.
The AC power cord grounds the chassis and protects it from electrical damage while you install the module.
2. Power off the chassis.
3. Inspect the slot pins on the chassis backplane for any bends or damage prior to installation. Do not install a module if the backplane is damaged.
4. Remove the black plastic covers from all the captive screws on the module front panel.
5. Identify a supported slot in the chassis. The following figure shows the symbols that indicate the slot types.
Figure 1. Chassis Compatibility Symbols
NI PXIe-1062Q
1
2 3
4
5
1. PXI Express System Controller Slot
2. PXI Peripheral Slot
3. PXI Express Hybrid Peripheral Slot
4. PXI Express System Timing Slot
5. PXI Express Peripheral Slot
PXIe-5160/5162 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots.
6. Touch any metal part of the chassis to discharge static electricity.
7. Ensure that the ejector handle is in the downward (unlatched) position.
8. Place the module edges into the module guides at the top and bottom of the chassis. Slide the module into the slot until it is fully inserted.
PXIe-5160/5162 Getting Started Guide | © National Instruments | 5
Figure 2. Module Installation
2
3
NI PXIe-1075
1
1. Chassis
2. Hardware Module
3. Ejector Handle in Downward (Unlatched) Position
9. Latch the module in place by pulling up on the ejector handle.
10. Secure the module front panel to the chassis using the front-panel mounting screws.
Note Tightening the top and bottom mounting screws increases mechanical
stability and also electrically connects the front panel to the chassis, which can improve the signal quality and electromagnetic performance.
11. Cover all empty slots using EMC filler panels or fill using slot blockers to maximize cooling air flow, depending on your application.
12. Power on the chassis.
6 | ni.com | PXIe-5160/5162 Getting Started Guide