The National Instruments PXIe- 1065 18- slot chassis features a highbandwidth backplane to meet a wide range of high- performance test and measurement application needs. The higher slot count of the NI PXIe- 1065 provides a solution for higher- channel- density systems. The chassis operates in a temperature range extended to 55 °C for applications needing cooling performance. It also incorporates all the features of the latest PXI specification including support for both PXI and PXI Express modules with a built-in 10 MHz reference clock, PXI trigger bus, and PXI star trigger for PXI modules and a built-in 100 MHz reference clock, SYNC 100, and PXI differential star trigger for PXI Express modules.
High Reliability
0 to 55 ° C extended temperature range Power supply, temperature, and fan monitoring HALT- tested for increased reliability Field- replaceable power supply shuttle
Multichassis Synchronization
PXI Express system timing slot for tight synchronization across chassis Rear CLK10 I/O connectors Switchless CLK10 routing
Optional Features
Front and rear rack- mount kits Replacement power supply and fan shuttle Filler panels Slot blockers for improved cooling performance Factory installation services
Slot PXI Express System PXI Express Peripheral Hybrid PXI
Bus Signaling PCI Express PCI Express
PCI (32/33)
PCI Express (x4)
PCI (32/33)
Bandwith
3 GB/s dedicated for PXI Express (3 x4 links)
132 MB/s shared for PXI
1 GB/s dedicated
132 MB/s shared (PXI) or
1 GB/s dedicated (PXI
Express)
132 MB/s shared
Number of Slots 1
4 1
4 9
1
Includes one system timing slot
Technical Sales
(866) 531-6285
orders@ni. com
| |
Print E-mail this Page Open Document as PDF
Last Revised: 2012-07- 30 10:18: 58.0
18-Slot PXI Express Chassis for PXI and PXI Express Modules
NI PXIe- 1065
Accepts 3U PXI, PXI Express, CompactPCI, and CompactPCI Express modules
Up to 1 GB/s per- slot dedicated bandwidth [x4 PCI Express]
700 W available power for 0 to 55 °C
Low- jitter internal 10 MHz reference clock for PXI slots with 25 ppm stability
Low- jitter internal 100 MHz reference clock for PXI Express slots with 25 ppm stability
Quiet operation for 0 to 30 °C at 45 dBA
Variable speed fan controller optimizes cooling and acoustic emissions
Remote power- inhibit control
Complies with PXI and CompactPCI specifications
Overview
|
Ordering Information Detailed Specifications
For user manuals and dimensional drawings, visit the product page resources tab on ni.com.
1/9 www.ni.com
Page 2
Back to Top
Slot Types Accept PXI and PXI Express Modules
The NI PXIe- 1065 enables higher- bandwidth systems and provides the flexibility to work with both PXI and PXI Express modules. The PXI Express system slot offers three x4 PCI Express links (1 GB/s single direction per link) and a x1 PCI Express link to a PCI Express- to-PCI translation bridge on the backplane. The PXI Express slots feature up to a 1 GB/s per­slot, per- direction dedicated bandwidth through a x4 PCI Express link connection. The PXI Express system timing slot provides a x4 PCI Express link to the system slot and accepts a PXI Express module or a PXI Express system timing controller for advanced timing and synchronization. The four PXI Express hybrid slots deliver connectivity to either a x4 PCI Express link to the system slot or to the 32-bit, 33 MHz PCI bus on the backplane. The nine remaining PXI slots provide connectivity to the 32-bit, 33 MHz PCI bus on the backplane.
Figure 1. NI PXIe- 1065 Chassis Backplane
Optimized Cooling and Acoustic Emissions
The NI PXIe- 1065 chassis integrates three pulse- width modulation (PWM) system fans to provide forced- air cooling that meets the increased cooling demands of PXI Express and CompactPCI Express. The NI PXIe- 1065 offers a HIGH fan setting to maximize cooling at any ambient temperature and an AUTO fan setting to minimize acoustic emissions at ambient temperatures below 30 °C. The chassis monitors air intake temperature and adjusts fan speed accordingly. With this technology, the NI PXIe- 1065 achieves acoustic noise levels as low as 45 dBA (sound pressure level measured at operator position according to ISO 7779).
Software System Configuration
The NI PXIe- 1065 chassis is configured with NI Measurement & Automation Explorer (MAX). With this software configuration tool, you can easily configure NI PXIe- 1065 systems without time­consuming manual installation of initialization files. MAX creates the pxisys. ini file that defines the layout and parameters of your PXI system including chassis, controller, and plug- in modules.
Replaceable Power Supply Shuttle
The NI PXIe- 1065 chassis include a removable high- performance universal AC power supply with built-in overcurrent protection. An isolated 12 VDC line provides power to the cooling fans, significantly reducing electrical noise on the chassis backplane. The NI PXIe- 1065 incorporates the power supply and fans into a single modular unit that you can replace quickly, resulting in a mean time to repair (MTTR) of less than five minutes.
External 10 MHz Reference Clock I/O Connectors
The NI PXIe- 1065 chassis include IN/OUT BNC connectors for the 10 MHz reference clock on the rear of the chassis. When the backplane detects a 10 MHz signal on the IN connector, it phase locks PXI_CLK10, PXIe_CLK100, and PXIe_SYNC100 to the external clock. The OUT connector provides a buffered, non-TTL version of the 10 MHz reference clock.
Remote Power Inhibit and Monitoring
The NI PXIe- 1065 chassis features remote power inhibit and voltage monitoring through a DB-9 connector on the rear of the chassis. Use this connector to switch off power or monitor the power remotely in the chassis.
Power Supply, Temperature, and Fan Monitoring
The NI PXIe- 1065 chassis monitors power supply voltages, air intake temperature, and fan speeds; and provides any failure feedback to the user via a bicolor LED located in the power switch button on the front of the chassis.
NI PXIe- 1065 Options
The NI PXIe- 1065 has several optional accessories for complete system integration and optimized chassis functionality. Front and rear rackmount kits are available for 19 in. rack- mounted systems. You can easily replace spare power supplies with little system downtime because of the modular nature of the NI PXIe- 1065 power supply and fan shuttle. You can use slot blockers to improve the overall cooling performance of the chassis.
Ordering Information
For a complete list of accessories, visit the product page on ni.com.
2/9 www.ni.com
Page 3
Back to Top
Back to Top
Products Part Number Recommended Accessories Part Number
Related Accessories
Replacement Power Supply and Fan Shuttle for NI PXIe-1065
779731-01 No accessories required.
PXI 18- Slot Front Panel Protector
781153-01 No accessories required.
NI 14/18- Slot Chassis Rear Rack Mount Kit
778644-02 No accessories required.
18-Slot Chassis Filler Panel Kit (to cover 17 slots)
778646-01 No accessories required.
NI 14/18- Slot Chassis Front Rack Mount Kit
778644-01 No accessories required.
PXIe-1065
PXIe-1065 Requires: 1 Cable
779730-01 Cable: Shielded - Power Cord, AC, U. S., 120 VAC, 2.3 meters 763000-01
Cable: Shielded - Power Cord, 240V, 10A, North American 763068-01
Support and Services
System Assurance Programs
NI system assurance programs are designed to make it even easier for you to own an NI system. These programs include configuration and deployment services for your NI PXI, CompactRIO, or Compact FieldPoint system. The NI Basic System Assurance Program provides a simple integration test and ensures that your system is delivered completely assembled in one box. When you configure your system with the NI Standard System Assurance Program, you can select from available NI system driver sets and application development environments to create customized, reorderable software configurations. Your system arrives fully assembled and tested in one box with your software preinstalled. When you order your system with the standard program, you also receive system- specific documentation including a bill of materials, an integration test report, a recommended maintenance plan, and frequently asked question documents. Finally, the standard program reduces the total cost of owning an NI system by providing three years of warranty coverage and calibration service. Use the online product advisors at ni. com/advisor to find a system assurance program to meet your needs.
Technical Support
Get answers to your technical questions using the following National Instruments resources.
Support - Visit ni. com/support to access the NI KnowledgeBase, example programs, and tutorials or to contact our applications engineers who are located in NI sales offices around the world and speak the local language. Discussion Forums - Visit forums. ni.com for a diverse set of discussion boards on topics you care about. Online Community - Visit community. ni.com to find, contribute, or collaborate on customer- contributed technical content with users like you.
Repair
While you may never need your hardware repaired, NI understands that unexpected events may lead to necessary repairs. NI offers repair services performed by highly trained technicians who quickly return your device with the guarantee that it will perform to factory specifications. For more information, visit ni. com/repair.
Training and Certifications
The NI training and certification program delivers the fastest, most certain route to increased proficiency and productivity using NI software and hardware. Training builds the skills to more efficiently develop robust, maintainable applications, while certification validates your knowledge and ability.
Classroom training in cities worldwide - the most comprehensive hands-on training taught by engineers. On-site training at your facility - an excellent option to train multiple employees at the same time. Online instructor- led training - lower- cost, remote training if classroom or on- site courses are not possible. Course kits - lowest- cost, self- paced training that you can use as reference guides. Training memberships and training credits - to buy now and schedule training later.
Visit ni. com/training for more information.
Extended Warranty
NI offers options for extending the standard product warranty to meet the life- cycle requirements of your project. In addition, because NI understands that your requirements may change, the extended warranty is flexible in length and easily renewed. For more information, visit ni. com/warranty.
OEM
NI offers design- in consulting and product integration assistance if you need NI products for OEM applications. For information about special pricing and services for OEM customers, visit ni. com/oem.
Alliance
Our Professional Services Team is comprised of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 700 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni. com/alliance.
Detailed Specifications
This appendix contains specifications for the NI PXIe- 1065 chassis.
3/9 www.ni.com
Page 4
Caution Specifications are subject to change without notice.
Electrical
AC Input
Input voltage range
100 to 240 VAC
Operating voltage range
1
90 to 264 VAC
Input frequency
50/60 Hz
Operating frequency range
1
47 to 63 Hz
Input current rating
10 –5 A
Over- current protection
12 A circuit breaker
Line regulation
3.3 V
<±0.2%
5 V
<±0.1%
±12 V
<±0.1%
Efficiency
70% typical
Power disconnect
The AC power cable provides main power disconnect. The front- panel power switch causes the internal
chassis power supply to provide DC power to the CompactPCI/PXI Express backplane. You also can use the rear- panel D- SUB 9- pin connector and power mode switch to control the internal chassis power supply.
DC Output
DC current capacity (I )
MP
Voltage Maximum Current
+3.3 V 61 A
+5 V 50 A
+12 V 45 A
–12 V 4 A
5 V
AUX
2.0 A
Note Maximum combined +3.3 V, +5 V, and +12 V power is 699 W. Maximum total power is 701.5 W.
Backplane pin current capacity
Slot +5 V V (I/O) +3.3 V +12 V –12 V 5 V
AUX
System Controller Slot 15 A - 15 A 30 A - 1 A
System Timing Slot - - 6 A 4 A - 1 A
Hybrid Peripheral Slot with PXI- 1 Peripheral 6 A 5 A 6 A 1 A 1 A -
Hybrid Peripheral Slot with PXI- 5 Peripheral - - 6 A 4 A - 1 A
PXI-1 Peripheral Slot 6 A 11 A 6 A 1 A 1 A -
Total system slot current should not exceed 45 A.
Note  PCI V(I/O) pins in PXI-1 peripheral slots and hybrid peripheral slots are connected to +5 V. The maximum power dissipated in the system slot should not exceed 140 W. The maximum power dissipated in a peripheral slot should not exceed 38.25 W.
Load regulation
Voltage Load Regulation
+3.3 V <5%
+12 V <5%
+5 V <5%
–12 V <5%
Maximum ripple and noise (20 MHz bandwidth)
Voltage Maximum Ripple and Noise
+3.3 V 50 mV
pp
+12 V 50 mV
pp
+5 V 50 mV
pp
–12 V
4/9 www.ni.com
Page 5
50 mV
pp
Over- current protection
All outputs protected from short circuit and overload with automatic recovery
Over- voltage protection
3.3 V and 5 V
Clamped at 20 to 30% above nominal output voltage
Power supply shuttle MTTR
Replacement in under 5 minutes
Chassis Cooling
Module cooling system
NI PXIe- 1065
Forced air circulation (positivepressurization) through three 165cfm fans with
High/Auto speed selector
Slot airflow direction
Bottom of module to topof module
Module cooling intake
Bottom rear of chassis
Module cooling exhaust
Along both sides and top of chassis
Power supply cooling system
Forced air circulation through twointegrated fans
Power supply cooling intake
Right side of chassis
Power supply cooling exhaust
Left side of chassis
Environmental
Maximum altitude
2,000 m (800 mbar) (at 25 ° C ambient)
Pollution Degree
2
For indoor use only.
Operating Environment
Ambient temperature range
0 to 55 ° C (Tested in accordance with IEC- 60068-2- 1 and IEC- 60068-2- 2.
Meets MIL-PRF- 28800F Class 3 lowtemperature limit and MIL- PRF- 28800F Class 2 hightemperature limit.)
Relative humidity range
10 to 90%, noncondensing (Tested in accordance with IEC- 60068-2- 56.)
Storage Environment
Ambient temperature range
– 40 to 71 °C (Tested in accordance with IEC- 60068-2- 1 and IEC- 60068-2-
2. Meets MIL-PRF- 28800F Class 3 limits.)
Relative humidity range
5 to 95%, noncondensing (Testedin accordance with IEC- 60068-2- 56.)
Shock and Vibration
Operational shock
30 g peak, half- sine, 11 ms pulse (Tested in accordance with IEC- 60068-2-
27. Meets MIL-PRF- 28800F Class 2 limits.)
Random Vibration
5 to 500 Hz, 0.3 g
rms
Acoustic Emissions
Sound Pressure Level (at Operator Position)
(Tested in accordance with ISO 7779. Meets MIL-PRF- 28800F requirements.)
Auto fan (up to ~30 °C ambient)
45.0 dBA
High fan
63.3 dBA
Sound Power
Auto fan (up to ~30 °C ambient)
55.5 dBA
High fan
76.2 dBA
Note Specifications are subject to change without notice.
Safety Standards
This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, andlaboratory use:
IEC 61010-1, EN 61010- 1
UL 61010- 1, CSA 61010-1
Note For UL and other safety certifications, refer to the product label or the section.
Online Product Certification
5/9 www.ni.com
Page 6
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
EN 61326 (IEC 61326): Class A emissions; Basic immunity
EN 55011 (CISPR 11): Group 1, Class A emissions
AS/NZS CISPR 11: Group 1, Class A emissions
FCC 47 CFR Part 15B: Class A emissions
ICES- 001: Class A emissions
Note For the standards applied to assess the EMC of this product, refer to the section.
Online Product Certification
Note For EMC compliance, operate this device with shielded cables.
CE Compliance 
This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows:
2006/95/EC; Low- Voltage Directive (safety)
2004/108/EC; Electromagnetic Compatibility Directive (EMC)
Online Product Certification
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit
ni.
, search by module number or product line, and click the appropriate link in the Certification column.
com/certification
Environmental Management
National Instruments is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous
substances from our products is beneficial not only to the environment but also to NI customers.
For additional environmental information, refer to the Web page at . This page contains the environmental regulations and directives
NI and the Environment
ni. com/environment
with which NI complies, as well as other environmental information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of the product life cycle, all products be sent to a WEEE recycling center. For more information about WEEE recycling centers, National
must
Instruments WEEE initiatives, and compliance with WEEE Directive 2002/96/EC on Waste Electrical and Electronic Equipment, visit .
ni. com/environment/weee. htm
Backplane
Size
3U- sized; one system slot (with three system expansion slots) and 17
peripheral slots. Compliant with IEEE 1101.10 mechanical packaging. PXI Express Specification compliant. Accepts both PXI Express and CompactPCI (PICMG 2.0 R 3.0) 3U modules.
Backplane bare- board material
UL 94 V- 0 Recognized
Backplane connectors
Conforms to IEC 917 and IEC1076- 4-101, and are UL94V- 0 rated
System Synchronization Clocks (PXI_CLK10, PXIe_CLK100, PXIe_SYNC100)
10 MHz System Reference Clock: PXI_CLK10
Maximum slot-to- slot skew
1 ns
Accuracy
±25 ppm max. (guaranteed over the operating temperature range)
Maximum jitter
5 ps RMS phase- jitter (10Hz– 1MHz range)
Duty- factor
45%–55%
Unloaded signal swing
3.3 V ±0. 3 V
Note For other specifications refer to the .
PXI-1 Hardware Specification
100 MHz System Reference Clock: PXIe_CLK100 and PXIe_SYNC100
Maximum slot-to- slot skew
100 ps
Accuracy
±25 ppm max. (guaranteed over the operating temperature range)
Maximum jitter
3 ps RMS phase- jitter (10Hz– 12kHz range), 2 ps RMS phase- jitter
(12kHz– 20MHz range)
Duty- factor for PXIe_CLK100
45%–55%
Absolute single- ended voltage swing (When each line in the differential pair
has 50W termination to 1.30 V or Thévenin equivalent)
400  –1000 mV
Note For other specifications refer to the .
PXI-5 PXI Express Hardware Specification
6/9 www.ni.com
Page 7
External 10MHz Reference Out (BNC on rear panel of chassis)
Accuracy
±25 ppm max. (guaranteed over the operating temperature range)
Maximum jitter
5 ps RMS phase- jitter (10Hz– 1MHz range)
Output amplitude
1 V ±20% square- wave into50Ω 2 V unloaded
PP PP
Output impedance
50 Ω ±5 Ω
External Clock Source
Frequency
10MHz ±100 PPM
Input amplitude
Rear panel BNC
200 mV to 5 V square- wave or sine-wave
PP PP
System timing slot PXI_CLK10_IN
5 V or 3.3 V TTL signal
Rear panel BNC input impedance
50 Ω ±5 Ω
Maximum jitter introduced by backplane
1 ps RMS phase- jitter (10Hz– 1MHz range)
PXIe_SYNC_CTRL
V
IH
2.0 –5.5 V
V
IL
0– 0.8 V
PXI Star Trigger
Maximum slot-to- slot skew
250 ps
Backplane characteristic impedance
65 Ω ±10%
Note For PXI slot to PXI Star mapping, refer to the section of the . For other specifications, refer to the
System Timing Slot NI PXIe- 1065 User Manual PXI-1 Hardware
.
Specification
PXI Differential Star Triggers (PXIe- DSTARA, PXIe- DSTARB, PXIe- DSTARC)
Maximum slot-to- slot skew
150 ps
Maximum differential skew
25 ps
Backplane differential impedance
100 Ω ±10%
Note For PXIe slot to PXI_DSTAR mapping, refer to the section of the . For other specifications, the NI PXIe- 1065
System Timing Slot NI PXIe- 1065 User Manual
complies with the .
PXI-5 PXI Express Hardware Specification
Mechanical
Overall dimensions
Standard chassis
Height
6.97 in. (177.1 mm)
Width
18.30 in. (464.8 mm)
Depth
18.40 in. (467.4 mm)
Note 0.57 in. (14.5 mm) is added to height when feet are installed. When tilted with front feet extended on table top, height is increased approximately 2.08 in. (52.8 mm) in front and 0.583 in. (14.8 mm) in rear.
Weight
12.8 kg (28.2 lb)
Chassis materials
Sheet Aluminum (5052- H32, 3003- H14, and 6061- T6), Extruded Aluminum
(6060- T6), and ColdRolled Steel, PC-ABS, Santoprene, Nylon
Finish
Conductive Clear Iridite onAluminum, Electroplated Nickel onCold Rolled
Steel Polyurethane Enamel
The following two figures show the NI PXIe- 1065 chassis dimensions. The holes shown are for the installation of the optional rack mount kits. You can install those kits on the
front or rear of the chassis, depending on which end of the chassis you want to face toward the front of the instrument cabinet. Notice that the front and rear chassis mounting
holes (size M4) are symmetrical.
NI PXIe- 1065 Chassis Dimensions (Front and Side)
7/9 www.ni.com
Page 8
NI PXIe- 1065 Chassis Dimensions (Bottom)
The following figure shows the chassis rack mount kit components.
NI Chassis Rack Mount Kit Components
8/9 www.ni.com
Page 9
Back to Top
1 Front Rack Mount Kit 2 NI Chassis 3 Optional Rear Rack Mount Kit
Note The chassis shown in the previous figure is representative of the NIPXI- 1044/1045 and NIPXIe- 1065 product line.
1
The operating range is guaranteed by design.
©2010 National Instruments. All rights reserved. CompactRIO, CVI, FieldPoint, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni. com, NI- DAQ, and NITestStand are trademarks of National Instruments. The
mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Other product and company names listed are trademarks or trade
names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency, partnership, or joint- venture relationship with National Instruments.
| | | |
My Profile RSS Privacy Legal Contact NI © 2012 National Instruments Corporation. All rights reserved.
9/9 www.ni.com
Loading...