National Instruments PXI-8214 User Manual

Page 1
PXI
NI PXI-8214 User Manual
NI PXI-8214 User Manual
October 2002 Edition
Part Number 323455A-01
Page 2
Support
Worldwide Technical Support and Product Information
National Instruments Corporate Headquarters
11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100
Worldwide Offices
Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 20, Brazil 55 11 3262 3599, Canada (Calgary) 403 274 9391, Canada (Montreal) 514 288 5722, Canada (Ottawa) 613 233 5949, Canada (Québec) 514 694 8521, Canada (Toronto) 905 785 0085, China 86 21 6555 7838, Czech Republic 02 2423 5774, Denmark 45 76 26 00, Finland 09 725 725 11, France 01 48 14 24 24, Germany 089 741 31 30, Greece 01 42 96 427, Hong Kong 2645 3186, India 91 80 4190000, Israel 03 6393737, Italy 02 413091, Japan 03 5472 2970, Korea 02 3451 3400, Malaysia 603 9596711, Mexico 001 800 010 0793, Netherlands 0348 433466, New Zealand 09 914 0488, Norway 32 27 73 00, Poland 22 3390 150, Portugal 210 311 210, Russia 095 238 7139, Singapore 65 6 226 5886, Slovenia 3 425 4200, South Africa 11 805 8197, Spain 91 640 0085, Sweden 08 587 895 00, Switzerland 056 200 51 51, Taiwan 02 2528 7227, United Kingdom 01635 523545
For further support information, refer to the Technical Support and Professional Services appendix. To comment on the documentation, send email to techpubs@ni.com.
© 2002 National Instruments Corporation. All rights reserved.
Page 3
Important Information
Warranty
The NI PXI-8214 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor.
The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free.
A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are covered by warranty.
National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical accuracy. In the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent editions of this document without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. In no event shall National Instruments be liable for any damages arising out of or related to this document or the information contained in it.
XCEPT AS SPECIFIED HEREIN, NATIONAL INSTRUMENTS MAKES NO WARRANTIES, EXPRESS OR IMPLIED, AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF
E
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PUR POSE. CUSTOMERS RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF
N
ATIONAL INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER. NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR DAMAGES RESULTING FROM LOSS OF DATA, PROFITS, USE OF PRODUCTS, OR INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE POSSIBILITY THEREOF. This limitation of the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including
negligence. Any action against National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service failures caused by owners failure to follow the National Instruments installation, operation, or maintenance instructions; owners modification of the product; owners abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside reasonable control.
Copyright
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National Instruments Corporation.
Trademarks
National Instruments™, NI™, and ni.com™ are trademarks of National Instruments Corporation.
Product and company names mentioned herein are trademarks or trade names of their respective companies.
Patents
For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or
ni.com/patents.
WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS
(1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT INJURY TO A HUMAN.
(2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY, COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND HARDWARE COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES, TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR MISUSES, OR ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE HEREAFTER COLLECTIVELY TERMED SYSTEM FAILURES). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD NOT BE RELIANT SOLELY UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID DAMAGE, INJURY, OR DEATH, THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO PROTECT AGAINST SYSTEM FAILURES, INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS. BECAUSE EACH END-USER SYSTEM IS CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.
Page 4
Compliance
FCC/Canada Radio Frequency Interference Compliance
Determining FCC Class
The Federal Communications Commission (FCC) has rules to protect wireless communications from interference. The FCC places digital electronics into two classes. These classes are known as Class A (for use in industrial-commercial locations only) or Class B (for use in residential or commercial locations). Depending on where it is operated, this product could be subject to restrictions in the FCC rules. (In Canada, the Department of Communications (DOC), of Industry Canada, regulates wireless interference in much the same way.)
Digital electronics emit weak signals during normal operation that can affect radio, television, or other wireless products. By examining the product you purchased, you can determine the FCC Class and therefore which of the two FCC/DOC Warnings apply in the following sections. (Some products may not be labeled at all for FCC; if so, the reader should then assume these are Class A devices.)
FCC Class A products only display a simple warning statement of one paragraph in length regarding interference and undesired operation. Most of our products are FCC Class A. The FCC rules have restrictions regarding the locations where FCC Class A products can be operated.
FCC Class B products display either a FCC ID code, starting with the letters EXN, or the FCC Class B compliance mark that appears as shown here on the right.
Consult the FCC Web site at
http://www.fcc.gov for more information.
FCC/DOC Warnings
This equipment generates and uses radio frequency energy and, if not installed and used in strict accordance with the instructions in this manual and the CE Marking Declaration of Conformity*, may cause interference to radio and television reception. Classification requirements are the same for the Federal Communications Commission (FCC) and the Canadian Department of Communications (DOC).
Changes or modifications not expressly approved by National Instruments could void the users authority to operate the equipment under the FCC Rules.
Class A
Federal Communications Commission
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Canadian Department of Communications
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Class B
Federal Communications Commission
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Page 5
Canadian Department of Communications
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Compliance to EU Directives
Readers in the European Union (EU) must refer to the Manufacturer’s Declaration of Conformity (DoC) for information* pertaining to the CE Marking compliance scheme. The Manufacturer includes a DoC for most every hardware product except for those bought for OEMs, if also available from an original manufacturer that also markets in the EU, or where compliance is not required as for electrically benign apparatus or cables.
To obtain the DoC for this product, click Declaration of Conformity at by product family. Select the appropriate product family, followed by your product, and a link to the DoC appears in Adobe Acrobat format. Click the Acrobat icon to download or read the DoC.
* The CE Marking Declaration of Conformity will contain important supplementary information and instructions for the user
or installer.
ni.com/hardref.nsf/. This Web site lists the DoCs
Page 6
Conventions
The following conventions are used in this manual:
» The » symbol leads you through nested menu items and dialog box options
to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box.
This icon denotes a note, which alerts you to important information.
This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, or a system crash.
bold Bold text denotes items that you must select or click in the software, such
as menu items and dialog box options. Bold text also denotes parameter names.
italic Italic text denotes variables, emphasis, a cross reference, or an introduction
to a key concept. This font also denotes text that is a placeholder for a word or value that you must supply.
monospace Text in this font denotes text or characters that you should enter from the
keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames and extensions, and code excerpts.
Page 7
Contents
Chapter 1 Hardware Overview
PXI-8214 Features .........................................................................................................1-1
Connectivity...................................................................................................................1-2
Connectors .....................................................................................................................1-2
Chapter 2 Installation
What You Need to Get Started ......................................................................................2-1
Installing the PXI-8214..................................................................................................2-1
Driver Installation ..........................................................................................................2-3
Windows XP....................................................................................................2-3
Windows 2000.................................................................................................2-3
Windows NT ...................................................................................................2-3
Windows 98.....................................................................................................2-4
Linux................................................................................................................2-4
Device Connection Guide ..............................................................................................2-4
Termination Configuration ............................................................................................2-6
Appendix A Specifications
Appendix B Technical Support and Professional Services
© National Instruments Corporation vii NI PXI-8214 User Manual
Page 8
Hardware Overview
The NI PXI-8214 PXI-to-Ultra2 SCSI Host Adapter provides an Ultra2 SCSI interface to PXI or CompactPCI (cPCI) systems. The PXI-8214 is a 16-bit Low Voltage Differential (LVD)/Single-Ended (SE) SCSI solution you can use to connect up to 15 SCSI devices. Data transfer rates of up to 40 MegaTransfers (MT)/s (80 Mbytes/s) are possible. The PXI-8214 is an ideal solution for the PXI/cPCI system that requires true high-speed continuous disk operation.
PXI-8214 Features
The PXI-8214 includes the following features:
LSI53C895A PXI-to-Ultra2 SCSI controller
PXI/cPCI interface
1
Supports 32-bit DMA bus master with 64-bit addressing
Bursts up to 133 Mbytes/s at 33 MHz with zero wait-state bus
master data
SCSI interface
Supports 16-bit LVD and SE signaling
Contains 68-pin high-density (HD) connector
Performs wide (16-bit) Ultra2, synchronous LVD, SCSI transfers
up to 40 MT/s
Supports up to 15 SCSI devices
Maximum cable length for point-to-point connections25 m
Has active termination for one end of the SCSI bus
Provides SCSI termination power source
Onboard flash ROM for storage of SCSI BIOS
SCSI bus activity LED
© National Instruments Corporation 1-1 NI PXI-8214 User Manual
Page 9
Chapter 1 Hardware Overview
Connectivity
Connectors
The PXI-8214 connects up to 15 SCSI devices, including CD-ROM drives, hard disks, printers, and scanners. This interface can support single-ended and low voltage differential (LVD) devices.
There are two connectors. Connector P1 is a cPCI backplane connector; connector J1 is a 68-contact alternative 3 shielded SCSI device connector.
NI PXI-8214 User Manual 1-2 ni.com
Page 10
Installation
This chapter explains how to install the PXI-8214.
What You Need to Get Started
PXI or cPCI system
PXI-8214 interface board
Driver for PXI-8214 (diskettes are included for Windows 2000 and
Windows NT; Windows XP has native support; you can download drivers for Windows 98, Linux, and other operating systems from the National Instruments Web site at
SCSI cable
2
ni.com/support)
SCSI device
SCSI terminator (may be part of SCSI device)
Installing the PXI-8214
Caution Electrostatic discharge can damage several components on the PXI-8214. To
avoid such damage in handling the board, touch the antistatic plastic package to a metal part of your system chassis before removing the board from the package.
Complete the following steps to install the PXI-8214:
1. Make sure your system is turned off. Keep the system plugged in so that it remains grounded while you install the PXI-8214.
2. Choose an unused PXI/cPCI slot in your system. The PXI-8214 requires a slot that supports bus arbitration or bus master cards.
3. Remove the slot cover for the slot you have chosen.
4. Make sure the injector/ejector handle is in its downward position. Align the PXI-8214 with the card guides on the top and bottom of the slot.
© National Instruments Corporation 2-1 NI PXI-8214 User Manual
Page 11
Chapter 2 Installation
Caution Do not raise the injector/ejector handle as you insert the PXI-8214. The module
will not insert properly unless the handle is in its downward position so that it does not interfere with the injector rail on the chassis.
5. Hold the handle as you slowly slide the module into the chassis until the handle catches on the injector/ejector rail.
6. Raise the injector/ejector handle until the module firmly seats into the backplane receptacle connectors. The front panel of the PXI-8214 should be even with the chassis front panel.
Figure 2-1 shows how to install the PXI-8214 in a PXI/CompactPCI chassis.
3
2
1
1 Injector/Ejector Handle 2 PXI-8214
ON STANDBY
1
2
3
4
5
6
7
8
4
3 PXI Chassis 4 Injector/Ejector Rail
Figure 2-1. Installing the PXI-8214 into a PXI/CompactPCI Chassis
7. Screw the front panel of the PXI-8214 to the front panel mounting rail.
8. Power on your system.
NI PXI-8214 User Manual 2-2 ni.com
Page 12
Driver Installation
Windows XP
The PXI-8214 should automatically install with the correct driver. You can verify installation in the Device Manager.
After verifying that your operating system recognizes the PXI-8214 properly, power down your system and connect your devices according to the Device Connection Guide section.
Windows 2000
Installation in an Existing Operating System
1. In the New Hardware Found Wizard, select Search for a suitable
Chapter 2 Installation
driver for my device and click Next.
Windows NT
2. Check the Floppy Disk box and insert the Windows 2000 driver
diskette into your floppy disk drive.
3. Windows 2000 should find the proper driver. You can verify installation in the Device Manager.
After verifying that your operating system recognizes the PXI-8214 properly, power down your system and connect your devices according to the Device Connection Guide section.
New System Installation
Refer to the installation instructions in the WIN2000.TXT file on the NI PXI-8214 Driver for Windows 2000 disk.
Installation in an Existing Operating System
1. In the Control Panel, double-click the SCSI Adapters icon.
2. Select the Drivers tab and click the Add button. In the box that appears, click the Have Disk button.
3. Point the dialog box to the
4. After you select the
© National Instruments Corporation 2-3 NI PXI-8214 User Manual
winnt/miniport/ directory on your
floppy disk.
oemsetup.inf file, you will be prompted to
restart your computer.
Page 13
Chapter 2 Installation
Windows 98
5. You can verify the installation by returning to the Control Panel and
double-clicking SCSI Adapters.
After verifying that your operating system recognizes the PXI-8214 properly, power down your system and connect your devices according to the Device Connection Guide section.
New System Installation
Refer to the installation instructions in the WINNT.TXT file on the NI PXI-8214 Driver for Windows NT 4.0 disk.
1. In the Add New Hardware Wizard, select Search for the best driver for your device.
2. If your driver is on a floppy disk, select that option. If not, point the wizard to the driver location.
3. Windows 98 should find the proper driver file. You can verify installation in the Device Manager.
After verifying that your operating system recognizes the PXI-8214 properly, power down your system and connect your devices according to the Device Connection Guide section.
Linux
Instructions for installing under Linux depend on the Linux kernel you are using. Refer to the instructions for your particular kernel. The PXI-8214 uses the LSI53C895A PCI-to-Ultra2 SCSI controller.
After verifying that your operating system recognizes the PXI-8214 properly, power down your system and connect your devices according to the Device Connection Guide section.
Device Connection Guide
readme.txt file included with the driver for
Each device on the SCSI bus must have a unique device number. The PXI-8214 has device number 7. Other devices on the bus must have their own unique number. For most devices, the user sets this device number with onboard switches. The device numbers do not need to be in any particular order, but they do need to be unique.
NI PXI-8214 User Manual 2-4 ni.com
Page 14
Chapter 2 Installation
Both ends of the SCSI bus must be terminated. The PXI-8214 default configuration terminates one end of the SCSI bus. (To change this configuration, refer to the Termination Configuration section.) The other end of your SCSI bus must be terminated also. Many SCSI devices have onboard termination that can be enabled, or you can add an external terminator to the end of the bus. Improper termination can cause unpredictable bus operation.
Cautions The PXI 8214 is a 16-bit SCSI interface using active termination that fully
terminates one end of the 16-bit SCSI bus. The user must provide termination for the other bus end.
You can use 8-bit devices (such as most SCSI CD-ROMs), but you must be careful when cabling and terminating these devices. If only 8-bit devices reside on the SCSI bus, you can use the 8-bit termination on those devices as the end termination.
However, if both 8-bit and 16-bit devices are used, end termination must be from either a 16-bit device at the end of the bus or an external 16-bit terminator. Terminating a 16-bit SCSI bus with an 8-bit device can result in unpredictable bus operation.
Each device must have at least 0.1 m (3.93 in.) of cabling between them. When connecting more than one device, you must use a daisy-chain configuration. A star configuration is not allowed.
PXI 8214 Terminated Device ID 7
Each cable is at least 100 cm
Termination of SCSI Bus
Figure 2-2. Single SCSI Device with Independent Termination
SCSI CD-ROM Device ID 4
© National Instruments Corporation 2-5 NI PXI-8214 User Manual
Page 15
Chapter 2 Installation
PXI 8214 Terminated Device ID 7
Each cable is at least 100 cm
SCSI CD-ROM Device ID 6
SCSI Hard Drive Device ID 9 Set up for Termination of SCSI Bus
Figure 2-3. Multiple SCSI Devices with Termination Handled by
Termination Configuration
In the default configuration shown in Figure 2-4, the PXI-8214 switches SW1-1 and SW1-2 are both set to ON to terminate the SCSI bus. In most applications, you should use the default configuration. To disable termination on the PXI-8214, you must set both the SW1-1 and SW1-2 switches to the OFF position. In all setups, both switches should be either ON or OFF. If the switches are mismatched, the board will function incorrectly.
the Last SCSI Device on the Bus
SW1
1234
On
Off
NI PXI-8214 User Manual 2-6 ni.com
Figure 2-4. SW1 Default Configuration
Page 16
Specifications
This appendix lists the electrical, mechanical, environmental, safety, and compliance specifications of the PXI-8214.
Electrical
A
Current
Physical
Voltage (V)
+3.3 225 mA 300 mA
+5 150 mA 500 mA
Board dimensions................................... 10.0 by 16.0 cm
Slot requirements ................................... One peripheral slot
Weight.................................................... 0.13 kg (0.28 lb)
Temperature ........................................... 0 to 50 °C, operating
Relative humidity................................... 10 to 90% noncondensing,
Typi cal Maximum
(3.9 by 6.3 in.)
–20 to 70 °C, storage
operating 5 to 95% noncondensing, storage
Functional shock .................................... 30 g peak, half-sine, 11 ms pulse
Random vibration................................... 5 to 500 Hz, 0.3 g
© National Instruments Corporation A-1 NI PXI-8214 User Manual
5 to 500 Hz, 2.4 g nonoperating
, operating
rms
,
rms
Page 17
Appendix A Specifications
Safety
This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use:
IEC 61010-1, EN 61010-1
UL 3121-1
CAN/CSA C22.2 No. 1010.1
Note For UL and other safety certifications, refer to the product label or ni.com.
Electromagnetic Compatibility
EMC/EMI ...............................................CE, C-Tick, and FCC Part 15
Electromagnetic emissions .....................EN 55011 Class A at 10 meters
(Class A) Compliant
FCC Part 15A above 1 GHz
Note For EMC compliance, operate this device with shielded cabling.
CE Compliance
Note See the Declaration of Conformity (DoC) for this product at ni.com for any
additional regulatory compliance information. You can find the DoC using the search utility and product model number.
Electromagnetic immunity .....................Evaluated to EN 61326:1997/
A1:1998, Table 1
This product meets the essential requirements of applicable European Directives, as amended for CE Marking, as follows:
Low-Voltage Directive (safety): 73/23/EEC
Electromagnetic Compatibility Directive (EMC): 89/336/EEC
NI PXI-8214 User Manual A-2 ni.com
Page 18
Technical Support and Professional Services
Visit the following sections of the National Instruments Web site at
ni.com for technical support and professional services:
SupportOnline technical support resources include the following:
Self-Help ResourcesFor immediate answers and solutions,
visit our extensive library of technical support resources available in English, Japanese, and Spanish at resources are available for most products at no cost to registered users and include software drivers and updates, a KnowledgeBase, product manuals, step-by-step troubleshooting wizards, hardware schematics and conformity documentation, example code, tutorials and application notes, instrument drivers, discussion forums, a measurement glossary, and so on.
B
ni.com/support. These
Assisted Support OptionsContact NI engineers and other
measurement and automation professionals by visiting
ni.com/ask. Our online system helps you define your question
and connects you to the experts by phone, discussion forum, or email.
TrainingVisit
interactive CDs. You also can register for instructor-led, hands-on courses at locations around the world.
System IntegrationIf you have time constraints, limited in-house
technical resources, or other project challenges, NI Alliance Program members can help. To learn more, call your local NI office or visit
ni.com/alliance.
If you searched your local office or NI corporate headquarters. Phone numbers for our worldwide offices are listed at the front of this manual. You also can visit the Worldwide Offices section of office Web sites, which provide up-to-date contact information, support phone numbers, email addresses, and current events.
ni.com/custed for self-paced tutorials, videos, and
ni.com and could not find the answers you need, contact
ni.com/niglobal to access the branch
© National Instruments Corporation B-1 NI PXI-8214 User Manual
Loading...