National Instruments PXI-7830R, PXI-7831R, 783R, PXI-7833R, PCI-7831R Getting Started

...
Getting Started with the NI 783x R
This document explains how to install and configure the National Instruments 783xR.
Introduction
The NI 783xR devices are R Series Reconfigurable I/O (RIO) devices with 16-bit analog input (AI) channels, 16-bit analog output (AO) channels, and digital I/O (DIO) lines.
The NI PXI-7830R and NI PCI-7830R have four independent AI channels, four independent AO channels, and 56 DIO lines.
The NI PXI-7831R/7833R and NI PCI-7831R/7833R have eight independent AI channels, eight independent AO channels, and 96 DIO lines.
Traditional I/O devices have a fixed functionality provided by an application-specific integrated circuit (ASIC), but the NI 783xR has a field-programmable gate array (FPGA) that allows you to define device functionality and timing.
You can use the LabVIEW FPGA Module to graphically design the NI 783xR timing and functionality without having to learn a low-level programming language or a hardware description language (HDL) traditionally used for FPGA design. With the LabVIEW FPGA Module, you create or download a custom virtual instrument (VI) to the FPGA. You can reconfigure the NI 783xR with a new VI at any time.
You can use the LabVIEW Real-Time Module to communicate with and control the NI 783xR while performing additional tasks, such as real-time floating-point processing and data logging.
Note If you are using LabVIEW but not the LabVIEW FPGA Module, you can create VIs
that run in LabVIEW to control existing FPGA VIs, but you cannot create new FPGA VIs.
The NI 783xR has Flash memory that you can use to store a startup VI. You can configure the VI to load to the FPGA and to run when the device powers up.
Required Components
This section lists the items necessary for using the NI 783xR with Windows 2000/XP and the LabVIEW Real-Time Module.
Documentation
The NI 783xR User Manual describes the electrical and mechanical aspects of the NI 783xR and contains information about device operation and programming. This document is included on the NI-RIO CD and is also available at
LabVIEW Help is available in LabVIEW by selecting Help»VI, Function, & How-To Help.
Hardware and Software
PXI-783x R with Windows 2000/XP
The following items are necessary to set up and use the PXI-783xR on a computer running Windows 2000/XP:
ni.com/manuals.
NI PXI-783xR.
The following software packages:
LabVIEW 7.1 or later.
LabVIEW FPGA Module 1.1 or later—required to develop
custom FPGA VIs.
NI-RIO 1.3 or later—included with the PXI-783xR.
Note The PXI-7831R supports LabVIEW 7.0 or later, LabVIEW FPGA Module 1.0 or
later, and NI-RIO 1.0 or later.
PXI/CompactPCI chassis and PXI/CompactPCI embedded controller
running Windows 2000/XP, or a computer running Windows 2000/XP and a MXI-3 link to a PXI/CompactPCI chassis.
At least one cable and device for connecting signals to the PXI-783xR.
Getting Started with the NI 783xR 2 ni.com
PXI-783x R with the LabVIEW Real-Time Module (ETS)
The following items are necessary to set up and use the PXI-783xR with the LabVIEW Real-Time Module for ETS:
NI PXI-783xR.
The following software packages:
LabVIEW 7.1 or later.
LabVIEW FPGA Module 1.1 or later—required to develop
custom FPGA VIs.
LabVIEW Real-Time Module 7.1 or later.
NI-RIO 1.3 or later—included with the PXI-783xR.
Ardence (formerly Venturcom) Phar Lap Embedded Tool Suite
(ETS).
Note The PXI-7831R supports LabVIEW 7.0 or later, LabVIEW FPGA Module 1.0 or
later, and NI-RIO 1.0 or later.
Host computer running Windows 2000/XP for developing your
application.
PXI/CompactPCI chassis and real-time embedded controller running
the Phar Lap ETS real-time operating system.
CAT 5 Ethernet crossover cable if the real-time PXI system is not
configured on a network. To connect the PXI system to a network port, use a standard CAT 5 10/100Base-T Ethernet cable.
At least one cable and device for connecting signals to the PXI-783xR.
PXI-783x R with the LabVIEW Real-Time Module (RTX)
The following items are necessary to set up and use the PXI-783xR with the LabVIEW Real-Time Module for RTX:
NI PXI-783xR.
The following software packages:
© National Instruments Corporation 3 Getting Started with the NI 783xR
LabVIEW 7.1 or later.
LabVIEW FPGA Module 1.1 or later—required to develop
custom FPGA VIs.
LabVIEW Real-Time Module 7.1 or later.
NI-RIO 1.3 or later—included with the PXI-783xR.
Ardence (formerly Venturcom) RTX 5.5 or later.
Note The PXI-7831R supports NI-RIO 1.1 or later.
PXI/CompactPCI chassis and real-time embedded controller running
Windows 2000/XP and RTX.
CAT 5 Ethernet crossover cable if the real-time PXI system is not
configured on a network. To connect the PXI system to a network port, use a standard CAT 5 10/100Base-T Ethernet cable.
At least one cable and device for connecting signals to the PXI-783xR.
PCI-783x R with Windows 2000/XP
The following items are necessary to set up and use the PCI-783xR on a computer running Windows 2000/XP:
PCI-783xR.
The following software packages:
LabVIEW 7.1 or later.
LabVIEW FPGA Module 1.1 or later—required to develop
custom FPGA VIs.
NI-RIO 1.3 or later—included with the PCI-783xR.
Note The PCI-7831R supports NI-RIO 1.1 or later.
Development computer running Windows 2000/XP.
At least one cable and device for connecting signals to the PCI-783xR.
Getting Started with the NI 783xR 4 ni.com
PCI-783x R with the LabVIEW Real-Time Module (ETS)
The following items are necessary to set up and use the PCI-783xR with the LabVIEW Real-Time Module for ETS:
PCI-783xR.
The following software packages:
LabVIEW 7.1 or later.
LabVIEW FPGA Module 1.1 or later—required to develop
custom FPGA VIs.
LabVIEW Real-Time Module for ETS 7.1 or later.
NI-RIO 1.3 or later—included with the PCI-783xR.
Ardence (formerly Venturcom) Phar Lap Embedded Tool Suite
(ETS).
Note The PCI-7831R supports NI-RIO 1.1 or later.
Host computer running Windows 2000/XP for developing your
application.
Target computer running the Phar Lap ETS real-time operating
system.
At least one cable and device for connecting signals to the PCI-783xR.
PCI-783x R with the LabVIEW Real-Time Module (RTX)
The following items are necessary to set up and use the PCI-783xR with the LabVIEW Real-Time Module for RTX:
PCI-783xR.
The following software packages:
LabVIEW 7.1 or later.
LabVIEW FPGA Module 1.1 or later—required to develop
custom FPGA VIs.
© National Instruments Corporation 5 Getting Started with the NI 783xR
LabVIEW Real-Time Module for RTX 7.1 or later.
NI-RIO 1.3 or later—included with the PCI-783xR.
Ardence (formerly Venturcom) RTX 5.5 or later.
Note The PCI-7831R supports NI-RIO 1.1 or later.
Computer running Windows 2000/XP and RTX.
Note RTX 5.5 does not support Hyper-Threading enabled processors. Refer to the RTX
documentation for information about disabling multiprocessor access.
At least one cable and device for connecting signals to the PCI-783xR.
Installing Software
Complete the following sets of steps in the order listed to successfully install LabVIEW, the LabVIEW Real-Time Module, the LabVIEW FPGA Module, and the NI-RIO device drivers.
If you are using NI-RIO without LabVIEW, skip these steps and proceed to the NI-RIO Device Drivers Installation section.
LabVIEW Installation
Complete the following steps to install LabVIEW. Refer to the LabVIEW Release Notes for additional information about installing LabVIEW.
1. Insert the LabVIEW CD into the CD-ROM drive to display the LabVIEW installation screen.
2. Click Install LabVIEW.
3. Follow the installer prompts through the rest of the installation.
LabVIEW Real-Time Module Installation
Complete the following steps to install the LabVIEW Real-Time Module. Refer to the LabVIEW Real-Time Module Release Notes for additional information about installing the LabVIEW Real-Time Module.
Note If you are using the NI 783xR with Windows 2000/XP only, it is not necessary to
install the LabVIEW Real-Time Module.
1. Insert the LabVIEW Real-Time Module CD into the CD-ROM drive to display the LabVIEW Real-Time Module installation screen.
2. Click Install LabVIEW Real-Time Module.
3. Follow the installer prompts through the rest of the installation.
Getting Started with the NI 783xR 6 ni.com
LabVIEW FPGA Module Installation
Complete the following steps to install the LabVIEW FPGA Module. Refer to the LabVIEW FPGA Module Release Notes for additional information about installing the LabVIEW FPGA Module.
1. Insert the LabVIEW FPGA Module CD into the CD-ROM drive to display the LabVIEW FPGA Module installation screen.
2. Click Install LabVIEW FPGA Module.
3. Follow the installer prompts through the rest of the installation.
NI-RIO Device Drivers Installation
Complete the following steps to install the NI-RIO device drivers that are included with the NI 783xR device.
Note You must install LabVIEW and the LabVIEW modules you will use before you
install the NI-RIO device drivers.
1. Run
2. Follow the on-screen instructions until the Feature Tree window
3. In the Feature Tree window, select the components to install. You must
4. Follow the on-screen instructions to complete the driver installation.
5. Restart the computer.
setup.exe from the NI-RIO CD and follow the setup
instructions.
appears.
install NI-VISA, NI-RIO, and NI Measurement & Automation Explorer (MAX).
© National Instruments Corporation 7 Getting Started with the NI 783xR
Installing Hardware
This section describes how to unpack and install the PXI-783xR and PCI-783xR devices.
Note You must install the NI-RIO device drivers before installing the NI 783xR.
Unpacking
The NI 783xR is shipped in an antistatic package to prevent electrostatic discharge from damaging device components. To prevent such damage when handling the device, take the following precautions:
Ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis.
Touch the antistatic package to a metal part of the computer chassis before removing the device from the package.
Caution Never touch the exposed pins of connectors.
Remove the device from the package and inspect the devices for loose components or any other sign of damage. Notify NI if the device appears damaged in any way. Do not install a damaged device into the computer.
Store the NI 783xR in the antistatic envelope when not in use.
PXI-783x R Installation
You can install the PXI-783xR in any available peripheral slot in the PXI or CompactPCI chassis. Complete the following instructions to install the PXI-783xR:
Note You must install the software before installing the hardware. For software
installation instructions, refer to the Installing Software section.
1. Power off and unplug the PXI or CompactPCI chassis.
2. Make sure there are no lit LEDs on the chassis. Wait for any lit LEDs
3. Remove the filler panel for the peripheral slot.
4. Ground yourself using a grounding strap or by touching a grounded
5. Insert the PXI-783xR into the slot. Use the injector/ejector handle to
to go out before continuing the installation.
object, such as the PXI or CompactPCI chassis.
fully inject the PXI-783xR into place.
Getting Started with the NI 783xR 8 ni.com
6. Screw the front panel of the PXI-783xR to the front panel mounting
7. Visually verify the installation. Make sure the PXI-783xR is not
8. Plug in and power on the PXI or CompactPCI chassis.
PCI-783x R Installation
You can install the PCI-783xR in any available PCI expansion slot in the computer. To achieve the best noise performance, leave as much room as possible between the PCI-783xR and other boards.
Complete the following instructions to install the PCI-783xR:
Note You must install the software before installing the hardware. For software
installation instructions, refer to the Installing Software section.
1. Power off and unplug the computer.
rails of the chassis.
touching other devices or components and that the PXI-783xR is fully inserted into the slot.
Caution To protect both yourself and the computer from electrical hazards, the computer
must remain off and unplugged until the PCI-783xR is completely installed.
2. Remove the computer cover. Make sure there are no lit LEDs on the motherboard. Wait for any lit LEDs to go out before continuing the installation.
3. Touch the metal part of the power supply case inside the computer to discharge any static electricity that might be on your clothes or body.
4. Locate the metal bracket that covers the cut-out in the back panel of the chassis for the slot you have selected. Remove and save the bracket-retaining screw and the bracket cover.
5. Align the PCI-783xR card-edge connector with the expansion slot receptacle. Using slow, evenly distributed pressure, press the PCI-783xR straight down until it seats in the expansion slot.
6. Reinstall the bracket-retaining screw to secure the PCI-783xR to the back panel rail.
7. Visually verify the installation.
8. Replace the computer cover, and plug the computer in.
© National Instruments Corporation 9 Getting Started with the NI 783xR
Using the NI 783x R with the LabVIEW Real-Time Module for RTX
You can use the LabVIEW Real-Time Module for RTX with the NI 783xR. After you have installed RTX, the LabVIEW Real-Time Module for RTX, and RTX support from the NI-RIO Driver CD, complete the following steps:
Note The NI-RIO device drivers and NI 783xR must be installed before adding RTX
support for the R Series device.
1. If necessary, close all NI software.
2. Select Start»Program Files»Ardence RTX»RTX»RTX Properties.
3. On the Plug and Play tab, right-click the name of your device and select Add RTX INF Support.
4. Click the Apply button. RTX Properties returns a Warning dialog box. Click OK.
5. In the RTX Properties window, click OK.
6. Right-click My Computer and select Properties.
7. Select the Hardware tab and click Device Manager.
8. For Windows XP, expand NI-RIO Devices, right-click the name of your device and select Update Driver. In the Hardware Update Wizard window, select Install the software automatically and click Next. When the wizard finishes installing the software, click Finish.
For Windows 2000, expand NI-RIO Devices, right-click the name of your device, and select Properties. On the Driver tab, click Update Driver. In the Upgrade Device Driver Wizard window, click Next. Select Search for a suitable driver for my device and click Next three times. When Windows finishes installing the software, click Finish.
9. In the Device Manager window, select View»Resources by connection.
10. In the Device Manager window, expand Interrupt Request (IRQ). Make sure that the NI 783xR is not sharing an IRQ with any other devices. Refer to the RTX Runtime Help for information about modifying a device.
11. Reboot your computer.
12. Select Start»Run. In the Run window, enter
Getting Started with the NI 783xR 10 ni.com
net start nirtrtx
and click OK.
The NI 783xR now supports RTX. When you launch LabVIEW, the NI 783xR appears in the LabVIEW Execution Target menu as FPGA Device [device name] visa://localhost::RTRTX::0/RIO0::INSTR.
Removing RTX Support
Complete the following steps to remove RTX support from the NI 7831R.
1. Close all NI software.
2. Select Start»Program Files»Ardence RTX»RTX»RTX Properties.
3. On the Plug and Play tab, right-click the name of your device and
4. Click Apply. RTX Properties returns a Warning dialog box. Click OK.
5. In the RTX Properties window, click OK.
6. Right-click My Computer and select Properties.
7. Select the Hardware tab and click Device Manager.
8. For Windows XP, expand RTX Drivers, right-click [device name]
select Remove RTX INF Support.
RTX Supported and select Update Driver.
You have removed RTX support for the NI 783xR.
© National Instruments Corporation 11 Getting Started with the NI 783xR
Connecting Signals
Figure 1 shows the I/O connector locations for the NI PXI-783xR and the NI PCI-783xR. The NI PXI-7830R and NI PCI-7830R do not have Connector 2 (DIO).
CONNECTOR 0 (MIO)
CONNECTOR 0 (MIO)
CONNECTOR 1 (DIO)
CONNECTOR 2 (DIO)
CONNECTOR 1 (DIO)
CONNECTOR 2 (DIO)
Figure 1. NI 783x R Connector Locations
Getting Started with the NI 783xR 12 ni.com
Figure 2 shows the I/O connector pin assignments for the I/O connectors on the NI 783xR. The DIO connector pin assignment applies to connector 1 on the NI 7830R and connectors <1..2> on the NI 7831R/7833R.
DIO39
DIO37
DIO35
DIO33
DIO31
DIO29
DIO27
DIO26
DIO25 DIO24 DIO23
DIO22
DIO21
DIO20
DIO19
DIO18
DIO17
DIO16
DIO15 DIO14
DIO13
DIO12
DIO11
DIO10
DIO9
DIO8
DIO7
DIO6
DIO5 DIO4
DIO3
DIO2
DIO1
DIO0
68 34
67 33
66 32
65 31
64 30
63 29
62 28
61 27
60 26
59 25
58 24
57 23
56 22
55 21
54 20
53 19
52 18
51 17
50 16
49 15
48 14
47 13
46 12
45 11
44 10
43 9
42 8
41 7
40 6
39 5
38 4
37 3
36 2
35 1
DIO38 DIO36
DIO34
DIO32
DIO30
DIO28
+5V
+5V
DGND DGND
DGND
DGND
DGND DGND DGND
DGND
DGND
DGND
DGND DGND
DGND
DGND
DGND
DGND
DGND
DGND DGND
DGND
DGND
DGND DGND
DGND
DGND
DGND
AI0+
AIGND0
AI1+
AI2+
AIGND2
AI3+
No Connect
AIGND4
No Connect No Connect
AIGND6
No Connect
AISENSE
AO0
AO1
AO2
AO3
No Connect
No Connect No Connect
No Connect
DIO15
DIO13
DIO11
DIO9
DIO7
DIO6
DIO5
DIO4 DIO3
DIO2
DIO1
DIO0
+5V
68 34
67 33
66 32
65 31
64 30
63 29
62 28
61 27
60 26
59 25
58 24
57 23
56 22
55 21
54 20
53 19
52 18
51 17
50 16
49 15
48 14
47 13
46 12
45 11
44 10
43 9
42 8
41 7
40 6
39 5
38 4
37 3
36 2
35 1
AI0–
AIGND1
AI1
AI2
AIGND3 AI3
No Connect
AIGND5
No Connect No Connect
AIGND7
No Connect
No Connect AOGND0 AOGND1
AOGND2
AOGND3
AOGND4
AOGND5 AOGND6
AOGND7
DIO14
DIO12
DIO10
DIO8
DGND DGND
DGND
DGND
DGND DGND
DGND
DGND
+5V
AI0+
AIGND0
AI1+
AI2+
AIGND2
AI3+
AI4+
AIGND4
AI5+ AI6+
AIGND6
AI7+
AISENSE
AO0
AO1
AO2
AO3
AO4
AO5 AO6
AO7
DIO15
DIO13
DIO11
DIO9
DIO7
DIO6
DIO5
DIO4 DIO3
DIO2
DIO1
DIO0
+5V
68 34
67 33
66 32
65 31
64 30
63 29
62 28
61 27
60 26
59 25
58 24
57 23
56 22
55 21
54 20
53 19
52 18
51 17
50 16
49 15
48 14
47 13
46 12
45 11
44 10
43 9
42 8
41 7
40 6
39 5
38 4
37 3
36 2
35 1
AI0–
AIGND1
AI1
AI2
AIGND3 AI3
AI4
AIGND5
AI5 AI6
AIGND7
AI7
No Connect AOGND0 AOGND1
AOGND2
AOGND3
AOGND4
AOGND5 AOGND6
AOGND7
DIO14
DIO12
DIO10
DIO8
DGND DGND
DGND
DGND
DGND DGND
DGND
DGND
+5V
NI 783xR DIO
Connector Pin Assignment
Caution
Connections that exceed any of the maximum ratings of input or output signals on the NI 783xR can damage the NI 783xR and the computer. NI is not liable for any damage resulting from such signal connections. Refer to the NI 783xR User Manual for the maximum input ratings for each signal.
For detailed information about connecting I/O signals, refer to the NI 783xR User Manual.
© National Instruments Corporation 13 Getting Started with the NI 783xR
NI 7830R MIO
Connector Pin Assignment
NI 7831R/7833R MIO
Connector Pin Assignment
Figure 2. NI 783x R I/O Connector Pin Assignments
Cabling Options
Accessing the signals on the I/O connectors requires at least one cable and one signal accessory. Table 1 summarizes the National Instruments cables available for use with the NI 783xR device.
Table 1. Cabling Options
Cable Connector Description
SH68-C68-S MIO/DIO For connecting signals from the MIO or DIO
connector to the NI SCB-68 terminal block.
SHC68-68-RMIO MIO For connecting signals from the MIO connector to
the SCB-68 terminal block.
Improves signal integrity and noise immunity. Provides shielding on all AI channels and an overall analog shield to reduce digital-to-analog crosstalk.
NSC68-262650 MIO For direct connection of the NI 783xR to 5B and
SSR analog and digital signal conditioning backplanes.
Routes signals to connectors that attach directly to 5B backplanes (for analog signals) and SSR backplanes (for digital signals).
NSC68-5050 DIO For direct connection of the NI 783xR and
SSR backplanes.
Routes signals to connectors that attach directly to SSR backplanes.
Related Documentation
Refer to the following documentation for information about the LabVIEW FPGA Module, R Series hardware, and VIs necessary for your application.
LabVIEW FPGA Module Release Notes— describes the software installation and other known software issues.
LabVIEW FPGA Module User Manual— describes the LabVIEW FPGA Module software and techniques for building applications in LabVIEW with the LabVIEW FPGA Module.
NI 783xR User Manual— describes the electrical and mechanical
Getting Started with the NI 783xR 14 ni.com
aspects of the NI 783xR and contains information about its operation and programming.
LabVIEW Help— describes the VIs and function reference information.
CompactRIO R Series Expansion System Installation Instructions— describes how to install the CompactRIO R Series Expansion chassis and CompactRIO I/O modules.
Where to Go from Here
Refer to the LabVIEW FPGA Module Release Notes for information about getting started with LabVIEW FPGA VIs and host VIs. This document also provides examples for verifying that your software and hardware are properly installed. To access this document, select Start»Programs» National Instruments»LabVIEW»Module Documents.
© National Instruments Corporation 15 Getting Started with the NI 783xR
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or ni.com/patents.
© 2003–2005 National Instruments Corporation. All rights reserved.
373256C-01 May05
Loading...