This document lists the specifications for the NI PXI/PCI-5124 (NI 5124)
high-speed digitizer. Unless otherwise noted, these specifications are valid
for the following conditions:
•All filter settings
•All impedance selections
•Sample clock set to 200 MS/s using onboard clock
Typical values are representative of an average unit operating at room
temperature. Specifications are subject to change without notice. For the
most recent NI 5124 specifications, visit
To access the NI 5124 documentation, including the NI High-Speed Digitizers Getting Started Guide, which contains functional descriptions
of the NI 5124 signals, navigate to Start»All Programs»National Instruments»NI-SCOPE»Documentation.
Hot Surface If the NI 5124 has been in use, it may exceed safe handling temperatures and
cause burns. Allow the NI 5124 to cool before removing it from the PXI chassis or PC.
Refer to the Environment section for operating temperatures of this device.
National Instruments TClk synchronization method and the NI-TClk driver
are used to align the sample clocks on any number of SMC-based modules
in a chassis. For more information about TClk synchronization, refer to the
NI-TClk Synchronization Help, which is located within the NI High-Speed
Digitizers Help.
•Specifications are valid for any number of modules installed in one
NI PXI-1042 chassis.
•All parameters set to identical values for each SMC-based module.
•Sample Clock set to200 MS/s and all filters are disabled.
•For other configurations, including multichassis systems, contact
NI Technical Support at
Note Although you can use NI-TClk to synchronize nonidentical modules, these
specifications apply only to synchronizing identical modules.
SpecificationVa lu eComments
Intermodule SMC Synchronization Using NI-TClk for Identical Modules (Typical)
manual adjustment, refer to
the Synchronization Repeatability Optimization
topic in the NI-TClk Synchronization Help.
For additional help with the
adjustment process, contact
NI Technical Support at
ni.com/support.
≤5ps—
Waveform Specifications
SpecificationVal ueComments
Onboard
Memory Size
8 MB per channel standard
(4 megasamples per channel)
32 MB per channel option
(16 megasamples per channel)
256 MB per channel option
(128 megasamples per channel)
*
NI PXI-5124 only
Minimum
Record Length
Number of
Pretrigger
Samples
Number of
Posttrigger
Samples
Maximum
Number of
Records in
Onboard
Memory
Allocated
Onboard
Memory per
Record
512 MB per channel option
(256 megasamples per channel)
*
1 Sample—
Zero up to full Record LengthSingle-record mode
and multiple-record
mode
Zero up to full Record LengthSingle-record mode
and multiple-record
mode
8 MB/channel 21,845
32 MB/channel 87,381
256 MB/channel 100,000†
*
NI PXI-5124 only
†
It is possible
to exceed these
numbers if you fetch
records while
512 MB/channel
*
100,000†
acquiring data.
For more
information, refer to
the NI High-Speed Digitizers Help.
(Record Length× 2 bytes/S) + 200 bytes, rounded up to
—
next multiple of 128 bytes
or
384 bytes, whichever is greater
NI PXI/PCI-5124 Specifications22ni.com
Calibration
SpecificationVal ueComments
Self-CalibrationSelf-calibration is done on software command.
The calibration corrects for gain, offset, frequency
response, triggering, and timing adjustment errors
for all input ranges.
External Calibration
(Factory Calibration)
Interval for External
Calibration
Warm-Up Time15 minutes—
The external calibration calibrates the VCXO and the
voltage reference. Appropriate constants are stored
in nonvolatile memory.
NI-SCOPE is an IVI-compliant driver that allows you to
configure, control, and calibrate the NI 5124. NI-SCOPE
provides application programming interfaces for many
development environments.
NI-SCOPE provides programming interfaces,
documentation, and examples for the following
application development environments:
•LabVIEW
™
• LabWindows
• Measurement Studio
• Microsoft Visual C/C++
• Microsoft Visual Basic
The Scope Soft Front Panel supports interactive control of
the NI 5124. The Scope Soft Front Panel is included on the
NI-SCOPE CD.
National Instruments Measurement & Automation Explorer
(MAX) also provides interactive configuration and test tools
for the NI 5124. MAX is included on the NI-SCOPE CD.
/CVI
™
—
—
—
NI PXI/PCI-5124 Specifications24ni.com
Environment
NI PXI-5124
Note To ensure that the NI PXI-5124 cools effectively, follow the guidelines in the
Maintain Forced Air Cooling Note to Users included in the NI PXI-5124 kit. The
NI PXI-5124 is intended for indoor use only.
SpecificationVa lu eComments
Operating
Temperature
Storage
Temperature
Operating Relative
Humidity
Storage Relative
Humidity
Operating Shock30 g, half-sine, 11 ms pulse
Storage Shock50 g, half-sine, 11 ms pulse
Operating Vibration5 Hz to 500 Hz, 0.31 g
Storage Vibration5 Hz to 500 Hz, 2.46 g
0 ºC to +55 ºC in all NI PXI chassis except the following:
0 ºC to +45 ºC when installed in an NI PXI-1000/B or
PXI-101x chassis
Meets IEC-60068-2-1 and IEC-60068-2-2
–40 ºC to +71 ºC
Meets IEC-60068-2-1 and IEC-60068-2-2
10% to 90%, noncondensing
Meets IEC-60068-2-56
5% to 95%, noncondensing
Meets IEC-60068-2-56
Meets IEC-60068-2-27
Test profile developed in accordance with
MIL-PRF-28800F
Meets IEC-60068-2-27
Test profile developed in accordance with
MIL-PRF-28800F
rms
Meets IEC-60068-2-64
rms
Meets IEC-60068-2-64
Test profile exceeds requirements of MIL-PRF-28800F,
Class B
—
—
—
—
—
—
—
—
Altitude2,000 m maximum (at 25 °C ambient temperature)—
Note To ensure that the NI PCI-5124 cools effectively, make sure that the chassis in which
it is used has active cooling that provides at least some airflow across the PCI card cage.
To maximize airflow and extend the life of the device, leave any adjacent PCI slots empty.
Refer to the Maintain Forced Air Cooling Note to Users included in the NI PCI-5124 kit
for important cooling information. The NI PCI-5124 is intended for indoor use only.
SpecificationVa lu eComments
Operating
Temperature
Storage
Temperature
Operating Relative
Humidity
Storage Relative
Humidity
Storage Shock50 g, half-sine, 11 ms pulse
0 ºC to +45 ºC
Meets IEC-60068-2-1 and IEC-60068-2-2
–40 ºC to +71 ºC
Meets IEC-60068-2-1 and IEC-60068-2-2
10% to 90%, noncondensing
Meets IEC-60068-2-56
5% to 95%, noncondensing
Meets IEC-60068-2-56
—
—
—
—
—
Meets IEC-60068-2-27
Test profile developed in accordance with
MIL-PRF-28800F
Storage Vibration5 Hz to 500 Hz, 2.46 g
rms
—
Meets IEC-60068-2-64
Test profile exceeds requirements of MIL-PRF-28800F,
Class B
Altitude2,000 m maximum (at 25 °C ambient temperature)—
Pollution Degree2—
NI PXI/PCI-5124 Specifications26ni.com
Safety, Electromagnetic Compatibility,
and CE Compliance
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control, and
laboratory use:
•IEC 61010-1, EN 61010-1
•UL 61010-1, CSA 61010-1
Note For UL and other safety certifications, refer to the product label or visit ni.com/
certification
in the Certification column.
Electromagnetic Compatibility
, search by model number or product line, and click the appropriate link
This product is designed to meet the requirements of the following
standards of EMC for electrical equipment for measurement, control,
and laboratory use:
•EN 61326 EMC requirements; Minimum Immunity
•EN 55011 Emissions; Group 1, Class A
•CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
Note For EMC compliance, operate this device with RG223/U or equivalent shielded
cable. Operate according to product documentation
CE Compliance
This product meets the essential requirements of applicable European
Directives, as amended for CE marking, as follows:
, search by model number or product line, and click the appropriate link
ni.com/
Environmental Management
⬉ᄤֵᙃѻક∵ᶧࠊㅵ⧚ࡲ⊩ ˄Ё
˅
Ёᅶ᠋
National Instruments is committed to designing and manufacturing
products in an environmentally responsible manner. NI recognizes that
eliminating certain hazardous substances from our products is beneficial
not only to the environment but also to NI customers.
For additional environmental information, refer to the NI and the Environment Web page at
environmental regulations and directives with which NI complies, as well
as any other environmental information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling
center. For more information about WEEE recycling centers and National Instruments
WEEE initiatives, visit
National Instruments
݇Ѣ
National InstrumentsЁRoHS
(For information about China RoHS compliance, go to
ni.com/environment/weee.htm.
Physical
ni.com/environment. This page contains the
RoHS
ヺড়Ё⬉ᄤֵᙃѻકЁ䰤ࠊՓ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ
ড়㾘ᗻֵᙃˈ䇋ⱏᔩ
ni.com/environment/rohs_china
ni.com/environment/rohs_china
(RoHS)
DŽ
DŽ
.)
Front Panel Connectors
LabelFunctionConnector Type
CH 0Analog InputBNC female
CH 1Analog InputBNC female
TRIGExternal TriggerBNC female
CLK INSample Clock Input and Reference
Clock Input
CLK OUTSample Clock Output and
Reference Clock Output
AUX I/OPFI 0, PFI 19-pin mini-circular DIN
NI PXI/PCI-5124 Specifications28ni.com
SMB jack
SMB jack
NI PXI-5124 Front Panel Indicators
LabelFunctionFor more
ACCESS The ACCESS LED indicates the status of the PCI bus and the
interface from the NI PXI-5124 to the controller.
ACTIVEThe ACTIVE LED indicates the status of the onboard
The National Instruments Web site is your complete resource for technical
support. At
troubleshooting and application development self-help resources to email
and phone assistance from NI Application Engineers.
A Declaration of Conformity (DoC) is our claim of compliance with the
Council of the European Communities using the manufacturer’s
declaration of conformity. This system affords the user protection for
electronic compatibility (EMC) and product safety. You can obtain the DoC
for your product by visiting
supports calibration, you can obtain the calibration certificate for your
product at
National Instruments corporate headquarters is located at
11500 North Mopac Expressway, Austin, Texas, 78759-3504.
National Instruments also has offices located around the world to help
address your support needs. For telephone support in the United States,
create your service request at
instructions or dial 512 795 8248. For telephone support outside the United
States, contact your local branch office:
Australia 1800 300 800, Austria 43 662 457990-0,
Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599,
Canada 800 433 3488, China 86 21 5050 9800,
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00,
Finland 358 (0) 9 725 72511, France 01 57 66 24 24,
Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737,
Italy 39 02 413091, Japan 81 3 5472 2970, Korea 82 02 3451 3400,
Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710,
Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466,
New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60,
Poland 48 22 3390150 , Portugal 351 210 311 210, Russia 7 495 783 6851,
Singapore 1800 226 5886, Slovenia 386 3 425 42 00,
South Africa 27 0 11 805 8197, Spain 34 91 640 0085,
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151,
Taiwan 886 02 2377 2222, Thailand 662 278 6777,
Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation.
Refer to the Terms of Use section on ni.com/legal for more information about National
Instruments trademarks. Other product and company names mentioned herein are trademarks or trad e
names of their respective companies. For patents covering National Instruments products, refer to the
appropriate location: Help»Patents in your software, the patents.txt file on your CD, or
ni.com/patents.