National Instruments Installation Instructions Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
INSTALLATION INSTRUCTIONS
LFH200 Cable
Ρ΅νιϋΠȂུࢊβȜΐ܄ȃ
This guide describes how to use the National Instruments LFH200 cable to connect the
NI PXI-2569/2570/2571/2575 or SCXI-1169/1175 switch module to your system.
The LFH200 cable is available in three configurations:
•SH200LFH-4xDB50F-C—Recommended for use with the PXI-2569/2570/2571 or
SCXI-1169.
•SH200LFH-4xDB50F-S—Recommended for use with the PXI-2575 or SCXI-1175.
•SH200LFH-BARE WIRE—Recommended for termination other than 50-pin female
D-SUB.
CautionThe LFH200 cable has a maximum voltage rating of 60 VDC. When using
the LFH200 cable with switch modules, do not exceed 60 VDC.
»The » symbol leads you through nested menu items and dialog box
options to a final action. The sequence Options»Settings»General
directs you to pull down the Options menu, select the Settings item,
and select General from the last dialog box.
This icon denotes a note, which alerts you to important information.
This icon denotes a caution, which advises you of precautions to take
to avoid injury, data loss, or a system crash.
boldBold text denotes items that you must select or click in the software,
such as menu items and dialog box options. Bold text also denotes
parameter names.
italicItalic text denotes variables, emphasis, a cross-reference, or an
introduction to a key concept. Italic text also denotes text that is a
placeholder for a word or value that you must supply.
monospaceText in this font denotes text or characters that you should enter from
the keyboard, sections of code, programming examples, and syntax
examples. This font is also used for the proper names of disk drives,
paths, directories, programs, subprograms, subroutines, device names,
functions, operations, variables, filenames, and extensions.
Getting Started
The following items are necessary for connecting the LFH200 cable:
❑LFH200 cable
❑NI PXI-2569/2570/2571/2575 or SCXI-1169/1175 switch module and documentation
Connecting the LFH200 Cable
Complete the following steps to connect the LFH200 cable to your switch module and
application. Refer to Figures 1 and 2 for illustrations of the LFH200 cable.
1.Connect the LFH200 connector to the connector on the switch module.
2.Tighten the thumbscrews.
3.Complete either of the following steps, and refer to Tables 1 through 16 to determine how
to connect your signals.
•Connect the D-SUB connectors to your application.
•Connect the unterminated wires to your application.
LFH200 Cable Installation Instructions2ni.com
1LFH200 Connector
4
1
2
3
2Thumbscrews
Figure 1. SH200LFH-4xDB50F-C or SH200LFH-4xDB50F-S Cable
3Cable Leg Label
450-Pin Female D-SUB Connectors
124
3
1LFH200 Connector
2Thumbscrews
3Cable Leg Label
425 Unterminated, Tinned, and Stripped Wires
The cable in this kit connects an LFH200 connector to four, 50-pin female D-SUB connectors
marked P1–P4, or eight bundles, leg J0–J7, of unterminated, tinned, and stripped wires. The
LFH200 connector provides connection to the switch module. The 50-pin female D-SUB
connectors and unterminated wires provide connection to your application. Figures 3 and 4
show the pinouts for these connectors.
Pin 51
Pin 50
Pin 1
Pin 100
Pin 150
Pin 151
Pin 200
Pin 101
LFH200 Cable Installation Instructions4ni.com
Figure 3. LFH200 Connector
Figure 4. 50-Pin Female D-SUB Connector
Cable Configurations
COM0
COM2
COM4
COM6
COM8
150
151
149
152
148
153
147
154
146
155
51
50
52
49
53
48
54
47
55
46
CH0
CH2
CH4
CH6
CH8
CH1
CH3
CH5
CH7
CH9
COM1
COM3
COM5
COM7
COM9
The LFH200 cable is available in three configurations:
•SH200LFH-4xDB50F-C
•SH200LFH-4xDB50F-S
•SH200LFH-BARE WIRE
The following sections describe each of the LFH200 cable configurations.
SH200LFH-4xDB50F-C Cable
The SH200LFH-4xDB50F-C cable is recommended for connecting the PXI-2569/2570/2571 or
SCXI-1169 to your system. One end of the cable terminates with an LFH200 connector which
connects to the switch module. The other end of the cable terminates with four 50-pin female
D-SUB connectors.
When using the SH200LFH-4xDB50F-C cable with the PXI-2569 or SCXI-1169, each Channel
and its corresponding Common form a twisted pair. For example, CH0 is paired with COM0,
and CH1 is paired with COM1. Figure 5 illustrates how this pairing relates to the pins on the
PXI-2569 or SCXI-1169.
Figure 5. Twisted Pair Groupings for the PXI-2569 or SCXI-1169
When using the SH200LFH-4xDB50F-C cable with the PXI-2570, each Channel and its
corresponding NO (Normally Open) connection form a twisted pair. The NC (Normally Closed)
connection is twisted with NO CONNECT wires. For example, COM0 is twisted with NO0, and
NC0 is twisted with a NO CONNECT wire. Figure 6 illustrates how this pairing relates to the
pins on the PXI-2570.
When using the SH200LFH-4xDB50F-C cable with the PXI-2571 the twisted pairs vary
depending on the channel. For the first 50 Channels, each COM and its corresponding NO
connection form a twisted pair. However, for the remaining 16 channels, the three components
(NC, COM, and NO) are each twisted with a NC component from the first 50 Channels. For
example, COM0 is twisted with NO0, and NC0 is twisted with NC50. COM1 is twisted with
NO1, and NC1 is twisted with COM50. COM2 is twisted with NO2, and NC2 is twisted with
NO50. Figure 7 illustrates how this pairing relates to the pins on the PXI-2571.
Figure 7. Twisted Pair Groupings for the PXI-2571
Refer to the NI Switches Help for a complete listing of channel names and pinouts.
The following tables list the pin assignments for the SH200LFH-4xDB50F-C cable.