National Instruments GPIB-RS232, GPIB-RS485, GPIB-RS422 Installation Manual

INSTALLATION GUIDE
NI GPIB-Serial Converter
GPIB-RS232 and GPIB-RS485/RS422
This guide includes instructions for installing and configuring your GPIB-RS232 or GPIB-RS485/RS422 hardware and NI GPIB-Serial Converter software on Windows 2000/XP.
Check the Hardware Configuration
The GPIB-RS232/485/422 is shipped with a 100–240 VAC wall-mount or desktop power supply. If you plan to use a different power source to power your GPIB-RS232/485/422, verify that the voltage marked on that power supply matches the input voltage marked on your GPIB-RS232/485/422.
Caution Do not operate your GPIB-RS232/485/422 at any voltage other
than that labelled on the unit. Doing so could damage the unit.
September 2006 371952B-01
The GPIB-RS232/485/422 ships with the following factory default power-on settings:
•D Mode
8 data bits/character
1 stop bit/character
Parity disabled
Serial port configured to 9600 baud
Hardware flow control
GPIB primary address 5
GPIB secondary address disabled
SRQ enabled
In D Mode, the GPIB-RS232/485/422 can act only as a GPIB Talker or Listener. To change any default setting, you must install the NI GPIB-Serial Converter software. For more information about D Mode settings, refer to the NI GPIB-Serial Converter Help, available after installing the software.
Install the Software
To install the NI GPIB-Serial Converter software, complete the following steps:
1. Log on as Administrator or as a user with administrator privileges.
2. Insert the NI GPIB-Serial Converter software CD.
3. If the autorun application does not start, run onscreen instructions to complete installation.
4. Reboot when prompted at the end of software installation.