The SCXI-1190, SCXI-1191, and SCXI-1192 are warranted against defects in materials and workmanship for a period of one year from the
date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that
proves to be defective during the warranty period. This warranty includes parts and labor.
The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects
in materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National
Instruments will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives
notice of such defects during the warranty period. National Instruments does not warrant that the operation of the software shall be
uninterrupted or error free.
A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before
any equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are
covered by warranty.
National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical
accuracy. In the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent
editions of this document without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected.
In no event shall National Instruments be liable for any damages arising out of or related to this document or the information contained in it.
XCEPT AS SPECIFIED HEREIN,NATIONAL INSTRUMENTS MAKES NO WARRANTIES, EXPRESS OR IMPLIED, AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF
E
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
NATIONAL INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER.NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR
DAMAGES RESULTING FROM LOSS OF DATA
. This limitation of the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including
THEREOF
negligence. Any action against National Instruments must be brought within one year after the cause of action accrues. National Instruments
shall not be liable for any delay in performance due to causes beyond its reasonable control. The warranty provided herein does not cover
damages, defects, malfunctions, or service failures caused by owner’s failure to follow the National Instruments installation, operation, or
maintenance instructions; owner’s modification of the product; owner’s abuse, misuse, or negligent acts; and power failure or surges, fire,
flood, accident, actions of third parties, or other events outside reasonable control.
, PROFITS, USE OF PRODUCTS, OR INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE POSSIBILITY
Copyright
Under the copyright laws, this publication may not be reproduced ortransmitted in any form, electronic or mechanical, including photocopying,
recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National
Instruments Corporation.
Trademarks
CVI™,LabVIEW™, National Instruments™,ni.com™, NI-DAQ™,PXI™,SCXI™, and VirtualBench™are trademarks of National Instruments
Corporation.
Product and company names mentioned herein are trademarks or trade names of their respective companies.
WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS
(1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF
RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN
ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT
INJURY TO A HUMAN.
(2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE
IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY,
COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS
AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND
HARDWARE COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL
DEVICES, TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR
MISUSES, OR ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE
HEREAFTER COLLECTIVELY TERMED “SYSTEM FAILURES”). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD
CREATE A RISK OF HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD
NOT BE RELIANT SOLELY UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID
DAMAGE, INJURY, OR DEATH, THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO
PROTECT AGAINST SYSTEM FAILURES, INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS.
BECAUSE EACH END-USER SYSTEM IS CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING
PLATFORMS AND BECAUSE A USER OR APPLICATION DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN
COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT EVALUATED OR CONTEMPLATED BY NATIONAL
INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY RESPONSIBLE FOR VERIFYING AND VALIDATING
THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER NATIONAL INSTRUMENTS PRODUCTS ARE
INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT LIMITATION, THE APPROPRIATE DESIGN,
PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.
.CUSTOMER’S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF
Compliance
FCC/Canada Radio Frequency Interference Compliance*
Determining FCC Class
The Federal Communications Commission (FCC) has rules to protect wireless communications from interference. The FCC
places digital electronics into two classes. These classes are known as Class A (for use in industrial-commercial locations only)
or Class B (for use in residential or commercial locations). Depending on where it is operated, this product could be subject to
restrictions in the FCC rules. (In Canada, the Department of Communications (DOC), of Industry Canada, regulates wireless
interference in much the same way.)
Digital electronics emit weak signals during normal operation that can affect radio, television, or other wireless products. By
examining the product you purchased, you can determine the FCC Class and therefore which of the two FCC/DOC Warnings
apply in the following sections. (Some products may not be labeled at all for FCC; if so, the reader should then assume these are
Class A devices.)
FCC Class A products only display a simple warning statement of one paragraph in length regarding interference and undesired
operation. Most of our products are FCC Class A. The FCC rules have restrictions regarding the locations where FCC Class A
products can be operated.
FCC Class B products display either a FCC ID code, starting with the letters EXN,
or the FCC Class B compliance mark that appears as shown here on the right.
Consult the FCC web site
http://www.fcc.gov
FCC/DOC Warnings
This equipment generates and uses radio frequency energyand, if not installed and used in strict accordance with theinstructions
in this manual and the CE Mark Declaration of Conformity**, may cause interference to radio and television reception.
Classification requirements are the same for the Federal Communications Commission (FCC) and the Canadian Department
of Communications (DOC).
Changes or modifications not expressly approved by National Instruments could void the user’s authority to operate the
equipment under the FCC Rules.
for more information.
Class A
Federal Communications Commission
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
Canadian Department of Communications
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Class B
Federal Communications Commission
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Canadian Department of Communications
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
European Union - Compliance to EEC Directives
Readers in the EU/EEC/EEA must refer to the Manufacturer's Declaration of Conformity (DoC) for information** pertaining
to the CE Mark compliance scheme. The Manufacturer includes a DoC for most every hardware productexcept for those bought
for OEMs, if also available from an original manufacturer that also markets in the EU, or where compliance is not required as
for electrically benign apparatus or cables.
* Certain exemptions may apply in the USA, see FCC Rules §15.103 Exempted devices,and§15.105(c). Also available in
sections of CFR 47.
** The CE Mark Declaration of Conformity will contain important supplementary information and instructions for the user or
installer.
Conventions
The following conventions are used in this manual:
»The » symbol leads you through nested menu items and dialog box options
to a final action. The sequence File»Page Setup»Options directs you to
pull down the File menu, select the Page Setup item, and select Options
from the last dialog box.
This icon denotes a note, which alerts you to important information.
This icon denotes a caution, which advises you of precautions to take to
avoid injury, data loss, or a system crash.
This icon denotes a warning, which advises you of precautions to take to
avoid being electrically shocked.
boldBold text denotes items that you must select or click on in the software,
such as menu items and dialog box options. Bold text also denotes
parameter names.
italicItalic text denotes variables, emphasis, a cross reference, or an introduction
to a key concept. This font also denotes text that is a placeholder for a word
or value that you must supply.
monospace
monospace bold
SCXI-119XRefers to the SCXI-1190 module, the SCXI-1191 module, and the
Text in this font denotes text or characters that you should enter from the
keyboard, sections of code, programming examples, and syntax examples.
This font is also used for the proper names of disk drives, paths, directories,
programs, subprograms, subroutines, device names, functions, operations,
variables, filenames and extensions, and code excerpts.
Bold text in this font denotes the messages and responses that the computer
automatically prints to the screen. This font also emphasizes lines of code
that are different from the other examples.
SCXI-1192 module.
Contents
Chapter 1
Installing and Configuring the SCXI-119X
About the SCXI-119X....................................................................................................1-1
Installing the Software ...................................................................................................1-2
This manual describes the electrical and mechanical characteristics of the
SCXI-1190 (quad 1 × 4, 50 Ω, 1.3 GHz bandwidth) and SCXI-1191 (quad
1 × 4,50Ω, 4 GHz bandwidth) multiplexer modules, and the SCXI-1192 (8-channel, SPDT, 50 Ω, 18 GHz bandwidth) relay module for the SCXI
bus. It also contains information concerning their installation, operation,
and safety instructions.
About the SCXI-119X
This section summarizes the features and operation of the SCXI-119X
switch modules. In addition, refer to Appendix A, Specifications,
for detailed specifications of the switch modules.
The SCXI-1190/1191 modules are general-purpose, quad 4-channel,
high-bandwidth multiplexing switches. The SCXI-1192 module is a
The SCXI-119X modules use single-pole double-throw, high-bandwidth
relays capable of switching signals from DC to 1.3 GHz bandwidth
(SCXI-1190), from DC to 4 GHz bandwidth (SCXI-1191), and from DC to
18 GHz bandwidth (SCXI-1192). The characteristic impedance of the
channels is 50 Ω.
For the SCXI-1190, the maximum rated voltage of the switch is 24 V,
and the maximum rated current is 1 A at 24 V. For the SCXI-1191, the
maximum rated voltage of the switch is 30 V, and the maximum rated
current is 0.33 A at 30 V. For the SCXI-1192, the maximum rated voltage
of the switch is 30 V, and the maximum rated current is 2 A
See Appendix A, Specifications, for full specifications.
You can control the SCXI-119X programmatically in an application
development environment (ADE) using NI-SWITCH. The supported
ADEs include LabVIEW, LabWindows/CVI, Visual Basic, and C or C++
environments. To install software for the SCXI-119X, complete the
following:
1.Insert your NI-SWITCH software CD into your CD-ROM drive.
The installation window should appear automatically.
Note
If the installation window does not appear, double-click the My Computer icon on
your PC desktop. Find the CD drive, and double-click it. In the CD directory, double-click
setup.exe
.
The NI-SWITCH and NI-DMM installation window offers three
choices:
•Install NI-DMM—Choose this selection if you want to install
only the DMM software.
•Install NI-SWITCH—Choose this selection if you want to install
only the switches software.
•Install NI-SWITCH and NI-DMM—Choose this selection if
you want to install both the DMM and switches software.
2.Click the Install NI-SWITCH option.
3.To install the instrument driver, VirtualBench, and application
development examples, choose Programmatic and InteractiveSupport. To install only the instrument driver files for VirtualBench,
choose Interactive Support Only.
Note
Choosing Interactive Support Only does not allow you to program the instrument
with any programming languages.
4.When installing NI-SWITCH, look at the DevelopmentEnvironments panel.
•If you click the Advanced button on this panel, you can custom
install National Instruments drivers such as NI-DAQ, NI-IVI, and
NI-VISA.
•If you do not want to install certain drivers, click Advanced and
uncheck the driver(s) you do not want installed.
If a driver is already unchecked, your computer has the same driver or
a newer version of the driver already installed.
SCXI-1190/1191/1192 User Manual1-2ni.com
Note
If a newer version of a driver is present on your PC, the installer will not overwrite
the driver.
Safety Instructions
Chapter 1Installing and Configuring the SCXI-119X
Cautions
instrument can become impaired if the instrument becomes damaged in any way. If the
instrument is damaged, do not use it until service-trained personnel can check its safety.
If necessary, return the instrument to National Instruments for service and repair to ensure
that its safety is not compromised.
Do not operate this instrument in a manner that contradicts the information specified in this
document. Misuse of this instrument could result in a shock hazard.
Do not substitute parts or modify equipment. Because of the danger of introducing
additional hazards, do not install unauthorized parts or modify the instrument. Return the
instrument to National Instruments for service and repair to ensure that its safety is not
compromised.
Connections that exceed any of the maximum signal ratings on the SCXI-119X can create
a shock or fire hazard or can damage any or all of the devices connected to the SCXI-119X.
National Instruments is not liable for any damages or injuries resulting from incorrect
signal connections.
Clean the instrument and accessories by brushing off light dust with a soft, nonmetallic
brush. Remove other contaminants with a stiff nonmetallic brush. The unit must be
completely dry and free from contaminants before returning to service.
Do not operate damaged equipment. The safety protection features built into this
Installing the Hardware
The following section describes how to unpack, install, and connect your
SCXI-119X for use with an SCXI chassis.
Make sure you read and understand all the safety information in this manual
Chapter 1Installing and Configuring the SCXI-119X
Unpacking
Your SCXI-119X module is shipped in an antistatic package to prevent
electrostatic damage to the module. Electrostatic discharge can damage
several components on the module. To avoid such damage in handling the
module, take the following precautions:
•Ground yourself using a grounding strap or by holding a grounded
object.
•Touch the antistatic package to a metal part of your computer chassis
before removing the module from the package.
Caution
Never touch the exposed pins of connectors.
Remove the module from the package and inspect the module for loose
components or any sign of damage. Notify National Instruments if the
module appears damaged in any way. Do not install a damaged module into
your computer.
Store your SCXI-119X module in the antistatic envelope when not in use.
Installing the SCXI-119X Module into an SCXI Chassis
You need the following items to complete the installation:
•SCXI-119X module
•SCXI chassis
SCXI-1190/1191/1192 User Manual1-4ni.com
Chapter 1Installing and Configuring the SCXI-119X
Follow these steps to install your SCXI-119X module into an SCXI chassis
while referring to Figure 1-1 and your chassis documentation:
5
1Slot1
2Slot2
3Slot3
4Slot4
6
7
S
C
M
A
I
N
F
R
8
1
3
Figure 1-1. Installing the SCXI-119X into an SCXI Chassis
1.Turn off the computer that contains the DAQ device or computer-based
instrument, or disconnect the computer from your SCXI chassis.
2.Turn off the SCXI chassis.
Caution
Do not insert the SCXI-119X module into a chassis that is powered on because
3.Remove the protective plastic caps from the thumbscrews of the
module so that the module will insert correctly.
4.Insert the SCXI-119X module into slot 1. Gently guide the module into
the module guides and push it to the back of the slot until the
connectors make good contact. The module must be firmly engaged;
however, do not force the module into place. If the module is not
sliding easily into the chassis, check for correct insertion into the
module guides.
When installing the SCXI-119X moduleinanSCXIchassis,fillslot1first,thenfill
slot 2 with the next SCXI-119X.
5.Insert any other SCXI modules into the remaining slots in the same
manner as described in step 4.
6.Secure all the SCXI-119X modules to the SCXI chassis by tightening
both module thumbscrews.
Connecting the SCXI-119X to a DAQ Device or Computer-Based
Instrument
You need the following items:
•SCXI chassis with the SCXI modules installed (Refer to the Installing
the SCXI-119X Module into an SCXI Chassis section for more
information.)
•SCXI cable assembly, which consists of a cable adapter and a cable
•An installed National Instruments DAQ device or computer-based
instrument, such as the NI 4060, that is able to control the SCXI
chassis
•1/4 in. flathead screwdriver
Consult your SCXI chassis documentation, other SCXI module
documentation, and DAQ device or computer-based instrument
documentation for additional instructions and warnings. Your SCXI-119X
module and any other SCXI modules should already be installed in the
chassis according to their installation instructions.
You must select one of the modules in the chassis as the cabled
module—the module to which the SCXI cable assembly connects. If the
chassis contains at least one SCXI-1140 module, select an SCXI-1140 as
the cabled module; otherwise, select one of the remaining modules.
Note
The SCXI-119X modules operate only in multiplexed mode.
SCXI-1190/1191/1192 User Manual1-6ni.com
Chapter 1Installing and Configuring the SCXI-119X
To connect the chassis to a DAQ device, complete the following steps while
referring to Figure 1-2:
1
4
®
1 SCXI Chassis Power Switch
2 Cable Adapter
1.Power off both the SCXI chassis and the computer that contains the
2.Insert the cable adapter into the back of the SCXI chassis aligned with
3.Connect the cable to the back of the cable adapter, ensuring that the
4.Connect the other end of the cable to the DAQ device or
3
2
3 Cable
4 DAQ Device or Computer-Based Instrument
Figure 1-2. ConnectinganSCXIChassistoaDAQDevice
or Computer-Based Instrument
DAQ device or computer-based instrument.
the module that is to be connected to the DAQ device or
computer-based instrument. See your cable assembly installation
guide for more specific information.
cable fits securely.
computer-based instrument that you will use to control the SCXI
system.
5.Check the cable installation, making sure the connectors are securely
fastened at both ends.
6.Power on the SCXI chassis.
7.Power on the computer.
8.If you have already installed the appropriate software, you are ready to
configure the SCXI-119X. If you have not installed the appropriate
software, refer to the Installing the Software section.
Connecting the SCXI-119X to a DAQ Device in a PXI
Combination Chassis
To connect the SCXI-119X to a DAQ device in a PXI combination chassis,
such as the PXI-1010 or PXI-1011, you need the following items:
•PXI combination chassis with the SCXI modules installed
•National Instruments PXI MIO DAQ device, or a computer-based
instrument that is capable of controlling SCXI, installed in the right
most slot of the PXI section of the combination chassis
A PXI combination chassis can use both SCXI and PXI modules at the
same time. Because the connection between the SCXI backplane and the
PXI backplane is made through a local bus interface to a PXI multifunction
I/O module installed in the right most slot, no external cabling is needed to
connect one PXI multifunction I/O module to the SCXI bus.
You should have already installed your SCXI-119X module and any other
SCXI modules in the chassis according to their installation instructions.
To use the SCXI-119X module with a DAQ device or computer-based
instrument in a PXI combination chassis, turn on the SCXI chassis.
Consult your PXI chassis documentation, other SCXI module
documentation, and DAQ device or computer-based instrument
documentation for additional instructions and warnings.
If you have already installed the appropriate software, you are ready to
configure the SCXI-119X. If you have not installed the appropriate
software, refer to the Installing the Software section.
SCXI-1190/1191/1192 User Manual1-8ni.com
Chapter 1Installing and Configuring the SCXI-119X
Configuring and Self-Testing the SCXI-119X
Run Measurement & Automation Explorer (MAX) to configure and test
your SCXI-119X. If you need help during the configuration process, open
the Measurement & Automation Help file by selecting Help»Help Topics.
1.Double-click the Measurement & Automation Explorer icon on
your desktop.
2.To add a new chassis, right-click Devices and Interfaces and select
Create New.
3.Select the appropriate chassis from the list box and click Finish.
4.To configure the chassis, select the Chassis ID. The chassis ID is an
arbitrary number that you choose for use by the software to uniquely
specify the chassis.
5.Select the Chassis Address (refer to your SCXI Chassis User Manual
for further information).
For the SCXI-2000, you also need to select the Baud Rate and
COM Port.
You now have the choice of auto-detecting your modules or manually
adding them depending on your application.
Auto-Detecting Modules
If you selected auto-detect and the chassis is not an SCXI-2000 remote
chassis, you must have your chassis connected to your National
Instruments device.
Note
Make sure you have your chassis powered on.
1.Click Next.
2.Select your communication path, except in the case of the SCXI-2000,
and click Next.
3.Select the module cabled to your communication path, except in the
case of the SCXI-2000 or if your module supports Auto Cable Detect,
and click Finish.