NATIONAL CONTROLS TNC-TM166, TM166 User Manual

Ordering Information:
The TM165 and TM166 panel mount digital thermometers are available in two distinct sizes. When ordering the thermometers, be sure to select the following depending on your specific application (refer to actual dimensions on back):
Panel Mount Digital Thermometer
MOUNTING CONFIGURATION PART NUMBER
Customer Panel Cutout TNC-TM165-010
Surface Mount Enclosure, Single TNC-TM165-KTA
1
Surface Mount Enclosure, Dual TNC-TM165-KT2A
1
1
Single and dual enclosures for TM165 version only
Optional Accessories
DESCRIPTION PART NUMBER
Six (6) foot refrigerator/freezer probe ASP-TM165-011
Transformer
(UL Class II Secondary) B10-N0120-011
Stainless steel enclosures for TNC-TM165-010 only
Single enclosure BOX-TM100-010
Dual enclosure BOX-TM100-020
National Controls Corporation
1725 Western Drive • West Chicago, Illinois 60185
Toll Free: 1-800-323-2593 • Direct: 630-231-5900 • Fax: 630-231-1377
E-mail: ncc@nationalcontrols.com • Web site:
www.nationalcontrols.com
© 2004, by AMETEK, Inc. All rights reserved. 1M1104CW (240009)
Product Description
National Controls' panel mount thermometer allows the constant monitoring of temperature in critical environments and equipment, enabling a higher degree of operating efficiency.
The high temperature alarm alerts personnel to a high temperature condition, protecting temperature sensitive equipment and operations. When the temperature rises to the setpoint temperature, the display flashes and an audible alarm sounds. When the temperature falls below the setpoint temperature, the alarm condition ceases. If during the alarm condition, it is desired to turn off the alarm, depressing the front panel push-button will interrupt the audible alarm for approximately 2-1/2 hours, but the display will continue to flash.
The heavy-duty stainless steel front plate protects the unit from mechanical shock and abuse, and is designed to blend visually with other stainless steel equipment.
The thermometer can be mounted directly on the equipment it is monitoring, or on a remote panel up to 250 feet away.
The thermometer is powered from low voltage AC or DC, thus eliminating the high costs of installation to NEC or other high voltage electrical standard wiring.
The control can also detect an open or shorted temperature probe. If the probe is open or shorted the display will show "Prb", the alarm will sound and the relay contacts will close. The alarm will continue to sound until the probe error condition is corrected. In addition, the output relay's contacts will close during a high temperature ALARM condition.
Setting the High Temperature Alarm:
On the front of the TM165 and TM166 there are up and down arrow buttons for changing the set point temperature. The set point can be adjusted to any temperature within the specified range of that particular model.
Setting ºF or ºC Operation:
Using the front panel buttons the display can be adjusted
to
display temperature in ºF or ºC.
Model TNC-TM165/TM166 Features
Heavy-duty stainless steel front plate and all metal case for rugged environments
Easy-to-read digital display
Temperature sensing range of -25ºF to 99ºF (-32ºC to 38ºC)
Front panel selectable ºF to ºC operation
Alarm temperature setting; programmable via front panel buttons
Alarm relay
Low voltage AC or DC operation
TM166 fits in a standard electrical box
Panel Mount
Panel Mount
Digital Thermometer
Digital Thermometer
Food Refrigeration Equipment
Food Refrigeration Equipment
TM165
TM166
National Controls Corporation
1725 Western Drive • West Chicago, Illinois 60185
Toll Free: 1-800-323-2593 • Direct: 630-231-5900 • Fax: 630-231-1377 • E-mail: ncc@nationalcontrols.com • Web site:
www.nationalcontrols.com
© 2004, by AMETEK, Inc. All rights reserved. 1M1104CW (240009)
Panel Mount
Panel Mount
Digital Thermometer
Digital Thermometer
Operating Specifications
Temperature Sensing Range: -25ºF to 99ºF (-32ºC to 38ºC)
Temperature Reading Accuracy: ±3ºF (2ºC)
Resolution: ±1ºF or ºC
Setpoint Range: -15ºF to 50ºF (-26ºC to 10ºC)
Input Voltage: 10.5 to 28 VAC, 50/60 Hz or 12 to 28 VDC
Power Consumption: 5VA max @ 28 VAC
WARRANTY
National Controls Corporation warrants its products for a period of one (1) year from date of receipt by user, but in no event more than eighteen (18) months from date of manufacture, against defective material or workmanship, but not against damage caused by accident, abuse, faulty installation, or improper application or operation. During this period, National Controls will, at its option, repair or replace defective products returned, transportation charges prepaid, to its factory. National Controls shall not be liable for any indirect or consequential damages. To the extent permitted by law, this warranty is given in lieu of all other warranties expressed or implied, and National Controls neither assumes nor authorizes any person to assume for it any liability beyond that stated herein.
Food Refrigeration Equipment
Food Refrigeration Equipment
Operating Temperature Range: 0ºC to 65ºC
Output Relay: Form A relay contact, 1 amp max @ 30 VAC
or DC
Temperature Probe: NTC thermistor, 3000 ohms @ 25ºC, J-Curve
TM165
TM166
3.120 [79.2]
.218 [5.54]
DIAMETER
(2 PLACES)
C
oaNitnoClna Csrlotorpora noit
L
1.560 [39.6]
POLYESTER
GRAPHIC OVERLAY
.170
[4.32]
5.000 [127]
.380 [9.7]
4.250 [108]
CLEARANCE HOLE
1.075
[27.31]
MAX.
ORANGE ORANGE
BLACK
RED
ALL 22 GA. WIRE
INCHES
[mm]
SEE NOTE 2
16.500
[419.10]
±.500
[12.70]
0.250 [6.35]
STRIP
±.062 [1.57]
10.5-28 VAC or
12-28 VDC
WIRING DIAGRAM
ALARM
OUTPUT
ORANGE
ORANGE
BLACKRED
2.87
[72.9]
±.06
1.44
[1.5]
[36.6]
.136 DIA. #8-32 TAP (2 PLACES)
SUGGESTED PANEL CUTOUT
3.87
[98.3]
±.06 [1.5]
.187
[4.75]
4.25
[108]
.170
[4.32]
82º
82º
1.075
[27.31]
MAX.
ORANGE ORANGE
BLACK
RED
ALL 22 GA. WIRE
INCHES
SEE NOTE 2
16.500
[419.10]
±.500
[12.70]
[mm]
2.750
[69.86]
C
L
1.375
[34.93]
2.250
[57.15]
3.281
[83.34]
C
4.500
[114.30]
L
1.641
[41.68]
.187
[4.75]
DIA. CLEARANCE HOLE
(2 PLACES)
NOTES:
1. IF KNOCK-OUTS ARE OFFSET INSIDE THE BOX, THE MINIMUM DIMENSION IS TAKEN BETWEEN THE INSIDE EDGES OF THE KNOCK-OUTS.
2. DIMENSION SHOWN IS TAKEN FROM THE SURFACE OF THE PRINTED CIRCUIT BOARD TO THE TIP OF THE WIRE.
N rlolanoitaCnot nitaroprCso o
POLYESTER
GRAPHIC OVERLAY
0.250 [6.35]
STRIP
±.062 [1.57]
PROBE
10.5-28 VAC or
12-28 VDC
WIRING DIAGRAM
ALARM
OUTPUT
ORANGE
ORANGE
PROBE
BLACKRED
SEE NOTE 1
1.89 MIN. [48.0]
2.85 MIN. [72.4]
MINIMUM INTERIOR DIMENSIONS
FOR INSTALLATION INTO A STANDARD UTILITY BOX
1.50 MIN.
[38.1]
Loading...