NATIONAL CONTROLS T1K-00001-461, T1 User Manual

1-6
Timing
On Off
On Off
Input Voltage
Relay Coil
Delay On Make Function
(3012-1)
1.75
2.40
.53
2.90
.85
7
8
1
2
3
4
5
6
Input
PIN CONFIGURATION
Voltage
Polarity Shown is
for D.C. Models
6
5
4
3
2
1
8
7
6
5
4
3
2
1 1
1
10
9
8
7
Voltage
Input
(by Cust.)
Timing Resistor
TIME DELAY RELAYS
Delay On Make
T1 Series
FEATURES
100% functionally tested
Digital timing circuit
±1% repeatability
Time calibrated dial
Superior transient protection
Internal components supported by heavy-duty chassis
Reinforced base locator pin
Flame-retardant polycarbonate housing
File #E59090
Operating Logic: Upon application of volt age to the input terminals, the time delay cycle starts. At the end of the preset time delay, the relay coil is energized and the contacts transfer. Reset is accomplished by the removal of input voltage.
Note: 1) Remote potentiometer leads should be shielded when running close to other wires; 2) The minimum time setting on external resistor-adjustable time delay relays is obtained by short ing together the external resistor terminals of the relay; 3) The maximum time setting within tolerance limits is obtained by using a 1 megohm resistor; 4) Timing values between the minimum and maximum limits are linear with resistance within 10%; 5) Recommend 1/4 W minimum resistor be used.
LOGIC FUNCTION DIAGRAM
SPECIFICATIONS
TIME DELAY
Adjustment: Knob or external resistor, factory
fixed on special order (min. order required)
Range: 50 ms to 1 hour in 8 ranges Repeatability: ±1% at constant temperature Accuracy: Maximum time -0%, +10%;
Minimum time +0%, -50%
Reset Time: 50 ms max. (25 ms typical)
INPUT
Operating Voltage: 24, 120, 240 VAC; 12, 24
VDC ±10% (DC models have reverse polarity pro­tection. Unfiltered input voltage to them must be full-wave rectified)
Power Consumption: 3 VA max. Frequency: 50/60 Hz
-
OUTPUT
Type: Relay contacts, DPDT (2 form C) Rating: 10 A max. resistive at 240 VAC; 100 mA
at 5 VDC min. load current
Life:
Mechanical: 10,000,000 operations Full Load: 500,000 operations
-
PROTECTION
Transient Voltage: 12, 24 V timers are protected
by an 8.8 joule metal oxide varistor; 120, 240 V timers are protected by a 30 joule metal oxide varistor
Dielectric Breakdown: 1500 VAC, RMS min. at 60 Hz between input and outputs and between outputs
MECHANICAL
Termination: 8-pin or 11-pin plug Mounting: Socket mount, 8-pin part number
MSO-0008P-012; Socket mount, 11-pin part number MSO-0011P-012
ENVIRONMENTAL
Storage Temperature: -23°C to 70°C Operating Temperature: -23°C to 55°C
ORDERING INFORMATION
TIME RANGE
.05 to 1 sec. T1K-00001-461
.1 to 10 sec.
.3 to 30 sec.
.6 to 60 sec.
1.8 to 180 sec.
3 to 300 sec.
6 to 600 sec.
36 to 3600 sec.
* Optional Potentiometer: Part Number ASY-0001M-450
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
12 VDC
KNOB ADJST.
8-PIN BASE
T1K-00010-466 T1K-00010-462 T1K-00010-467 T1K-00010-461 T1F-00010-461* T1K-00010-465
T1K-00030-466 T1K-00030-461
T1K-00060-466 T1K-00060-462 T1K-00060-467 T1K-00060-461 T1F-00060-461* T1K-00060-465
T1K-00180-461
T1K-00300-461
T1K-00600-461
T1K-03600-461
KNOB ADJST.
24 VDC
8-PIN BASE
24 VAC
KNOB ADJST.
8-PIN BASE
120 VAC
KNOB ADJST.
8-PIN BASE
120 VAC
REMOTE POT
11-PIN BASE
240 VAC
KNOB ADJST.
8-PIN BASE
External Resistance/Time Delay Relationship
1 megohm external resistance is required to obtain the maximum time for all ranges. To determine the actual resistance needed to obtain the required time delay, use the following formula:
Trequired - Tminimum
Rt=
Tmaximum - Tminimum
Note: Due to component tolerances, the actual time obtained will normally be within 5% of desired time.
Consult factory for any special requirements not listed in catalog (minimum order requirement may apply).
x 1,000,000 ohms
Loading...