NATIONAL CONTROLS Q1D-01024-31M, Q1D User Manual

Delay on Make (Series Load)
Timing
On Off
On Off
Input V
oltage
Load
Delay On Make Function
.170
DIA.
.885
1.25 MAX
.250 X .032 MALE
SPADE TERMINAL
(2 PL.
)
7865/7/97
C L
C
L
2.00 SQ.
1248163264
128
256
512
ON
OFF
10 POSITION SWITCH
VOLTAGE
INPUT
LOAD
TIME DELAY SELECT
Q1D Series
TIME DELAY RELAYS
1-11
FEATURES
100% functionally tested
Time delay from 1 to 1023 seconds in 1
second increments Universal input voltage 24 to 240
VAC/DC Solid state digital timing
Low cost
Compact size
Superior transient protection
Flame-retardant and solvent-resistant polyester thermoplastic housing
Allows user to accurately set delay times up to 1023 seconds without time consuming trial and error adjustments.
Operating Logic: Upon application of input voltage, the delay starts. At the end of the time delay, the load is energized. Reset is accomplished by removing input voltage. Set the delay time by switching the appro priate combination of time values to the ON position.
Note: The load may be located on either side of the line
LOGIC FUNCTION DIAGRAM
File #E65038
-
SPECIFICATIONS
TIME DELAY
Adjustment: 10 position DIP switch Range: 1 to 1023 seconds in one second incre-
ments. Zero time setting is undefined. Repeatability: ±0.5% (0.25% typical) at constant
temperature
Accuracy: ±10% of set time +0.25 second
INPUT
Operating Voltage: 24 to 240 VAC/DC ±10% (on
voltage must be full-wave rectified)
Frequency: 50/60 Hz
OUTPUT
Type: Solid state, normally open series load Rating: 1 A steady state max. Life: 100,000,000 operations
PROTECTION
Transient Voltage: 30 joule metal oxide varistor Dielectric Breakdown: 3000 VAC, RMS, termi
nals to mounting Insulation Resistance: 100 megohms min.
between terminals and case
MECHANICAL
Termination: .25” x .032” male fast-on terminals Mounting: Surface mount with one #8 screw
ENVIRONMENTAL
Storage Temperature: -40°C to 85°C Operating Temperature: -40°C to 65°C Humidity: 95% relative
-
ORDERING INFORMATION
Reset time, during timing 125 ms
Reset time, after timeout 10 ms
Min. load 10mA or 1 VA, whichever is greater
Max. leakage current 2 mA
Voltage drop at 1 A 3.3 V max.
Power consumption, during timing 0.25 VA max.
Power consumption, after timeout 3.3 VA max.
Peak 1 cycle surge 20 A
Protection 30j. MOV
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
TIME RANGE 24 to 240 VAC/DC +10%
1 to 1023 sec. Q1D-01024-31M