NATIONAL CONTROLS NS210 User Manual

LIQUID LEVEL CONTROL SERIES
L2 L1
LOW
HEAT FILL
C
To Probes
and Tank
3.50
4.00
2.25
1.25
4.50
5.00
.25
.25
NS210
Input
Voltage
1.75 max.
LIGHT
(5) .14 Dia
Low
Light
Heat
L H
Mounting Holes
Fill
(3672-1)
(3672-2)
PROBES
FILL
HEAT
HEAT
FILL
Input
Voltage
To Probes and Tank
3.50
4.00
2.50
3.00
1.75
Max.
L H
To conductive
tank
High Probe Low Probe
Heating Element
To Level Control
L H
C
L1 L2
(4) .14 Dia
C
Mounting Holes
NS211
.25
.25
Resistance Sensors (Pump Up Logic with Heater Burn Out Protection)
Models NS210 and NS211
2-5
FEATURES
100% functionally tested
Solid state sensing circuitry
Isolated UL Class ll sensing voltage
Conformal coating to protect circuit
from harsh environments
File #E61377
Operating Logic: Assuming an empty tank, upon application of voltage to the system, the fill output is turned on and the heat er output is off. As the liquid fills the tank, and when it reaches the low probe (above heater), the heater output is turned on. The level will rise until it reaches the high probe causing the fill output to turn off. As liquid is removed from the tank, 2 to 4 seconds after it breaks contact with the high probe, the fill output is turned on and stays on until the liquid reaches the high probe. This time delay eliminates fill output chatter if the liq uid is splashing. If the tank is non-conductive, a third (common) probe must be installed at a level where it will always be submerged.
SPECIFICATIONS
CONTROL TYPE
On/Off Resistance Sensing:
On low probe: probe resistance below set point activates heater output On high probe: probe resistance above set point activates fill output after a 2 to 4 sec. delay
Sensing Voltage: 15 VAC, max. RMS Sensing Current: 2 mA, max. RMS Sensitivity Adjustment: Factory set at
50 K ohms ±10%
-
INPUT
Operating Voltage: 24, 120, 240 VAC, ±10% Power Consumption: 3.0 VA max. Frequency: 50/60 Hz
OUTPUT
Type: Relay contacts, switch loads to L1 Rating: 5 A resistive at 240 VAC Life:
Mechanical: 5,000,000 cycles Electrical: 100,000 min. at full load
PROTECTION
-
Isolation: 1500 VAC between probe and other terminals
MECHANICAL
Terminations: 1/4” x .032” male fast-ons Mounting: 4 - .141” dia. mounting holes
ENVIRONMENTAL
Operating Temperature: 0°C to 55°C
ORDERING INFORMATION
Pump Up 24 VAC LNC-NS210-024
Pump Up 120 VAC
Pump Up 240 VAC LNC-NS210-240
Pump Up 120 VAC
Probe Holder with Ground LLH-11383-010
Probe, 6” Long, 1/4” Dia., S.S.
Probe, 12” Long, 1/4” Dia., S.S.
Probe, 24” Long, 1/4” Dia., S.S.
Probe Assembly, Plastic Body LLP-001/2-011
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
LNC-NS210-120
LLP-06.00-OSS
LLP-12.00-OSS
LLP-24.00-OSS
LNC-NS211-120
LOGIC TYPE INPUT VOLTAGE PART NUMBER
ACCESSORY PART NUMBER