NATIONAL CONTROLS NS127, NS128, NS143 User Manual

2-4
2.12
3.00
1.50
L1N.O.
L H
To probes and tank
3.62
4.00
Isolated relay
Input
(4) .14 Dia
Mounting holes
C
COM
output
Voltage
(3672-6)
NS127, NS128
N.C. L2
.19
.44
L1L2N.O.
L H C
2.12
2.50
1.56
3.12
2.00
Input
Voltage
To Probes and Tank
L
To conductive tank
High Probe
.
Low Probe
Typical Probe Connection
To Level Control
NS143
Mounting holes
C
(3672-3)
LOAD
.19
PROBES
(2) .187 Dia.
H
LIQUID LEVEL CONTROL SERIES
Resistance Sensors (Dual Probe)
Models NS127, NS128 and NS143
FEATURES
100% functionally tested
Isolated UL Class ll sensing voltage
1/4” male fast-ons for circuit connection
from harsh environments
and NS128 only
Operating Logic: In the Model NS127 Pump Down) the output relay is de-ener­gized until the liquid reaches the high probe. When liquid touches the high probe, the output relay is activated until the level drops below the low probe. In Models NS128 and NS143 (Pump Up) the output relay is energized until the liq uid reaches the high probe. When the liquid touches the high probe, the output relay is deactivated until the level drops below the low probe. If the tank is non-conductive, a third (common) probe must be installed at a level where it will always be submerged.
File #E61377 Model NS127
-
SPECIFICATIONS
CONTROL TYPE
On/Off Resistance Sensing:
NS127: Probe resistance below set point acti­vates relay NS128 and NS143: Probe resistance above set point activates relay
Sensing Voltage: 15 VAC, max. RMS Sensing Current: 2 mA, max. RMS Sensitivity Adjustment:
NS127 and NS128: Factory set at 100k ohms ±10% NS143: Factory set at 50 K ohms ±10%
OUTPUT
Type:
NS127 and NS128: Isolated relay contacts, SPDT (1 Form C) NS143: Relay contact SPST-NO switches L1 to normally open terminals
Rating:
NS127 and NS128: 10 A resistive at 120 VAC, 5 A resistive at 240 VAC NS143: 5 A resistive at 120, 240 VAC, 100 mA at 5 VDC minimum load current
Life: Mechanical: NS143: 5,000,000 cycles NS127, NS128: 10,000,000 Electrical: 100,000 min. at full load
INPUT
Operating Voltage: 120, 240 VAC, ±10% Power Consumption: 3.0 VA max. Frequency: 50/60 Hz
PROTECTION
Isolation: 1500 VAC between probe and other
terminals
MECHANICAL
Terminations: 1/4” x .032” male fast-ons Mounting:
NS127 and NS128: 4 -.141” dia. mounting holes NS143: 2 -.187” dia. mounting holes
ENVIRONMENTAL
Operating Temperature: -20°C to 55°C
ORDERING INFORMATION
LOGIC TYPE INPUT VOLTAGE PART NUMBER
Pump Down 120 VAC LNC-NS127-120
Pump Down 240 VAC LNC-NS127-240
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
Pump Up 120 VAC
Pump Up 240 VAC
Pump Up 120 VAC LNC-NS143-120
Pump Up 240 VAC
Probe Holder with Ground LLH-11383-010
Probe, 6” Long, 1/4” Dia., S.S.
Probe, 12” Long, 1/4” Dia., S.S.
Probe, 24” Long, 1/4” Dia., S.S.
Probe Assembly, Plastic Body LLP-001/2-011
LNC-NS128-120
LNC-NS128-240
LNC-NS143-240
ACCESSORY PART NUMBER
LLP-06.00-OSS
LLP-12.00-OSS
LLP-24.00-OSS