NATIONAL CONTROLS NS141 User Manual

2-8
240V120VCOM
LNC-NS141-*10
240 V COM120 V
LOAD
HI
LO
COM
3.50
4.00
1.40
2.80
.187 X .020 MALE
FAST-ON (3 PL)
.250 X .032 MALE FAST-ON (6 PL)
.10
.312
MAX
1.70
.250
R
R
E61377
A B
IDLE
(RED LED)
LOAD
120 V
COM 240V120V
240 V
COM
COM HI
LO
075
120 VAC
240 VAC
INPUT VOLTAGE
LOAD
NOTE: MUST USE COM TO 120 V
OUTPUT WHEN 120V INPUT IS USED
MUST USE COM TO 240 V OUTPU
T
WHEN 240 V INPUT IS USED
4
8
12
16
0
68 (20) 104 (40) 140 (60) 176 (80)
AMBIENT TEMPERATURE F ( C)
MAXIMUM LOAD VS. AMBIENT
LOAD CURRENT (AMPS RMS)
075
075
075
075
075
075
075
075
12" X 12" HEATSINK
10" X 10" HEATSINK
6" X 6" HEATSINK
NO HEATSINK
4608/12/94
LIQUID LEVEL CONTROL SERIES
Resistance Sensors (Dual Probe, Dual Voltage) 1hp Solid State Output
Model NS141
FEATURES
100% functionally tested
16 A 1 hp solid state output rating
120/240, 100/200 VAC operation
Isolated UL Class ll sensing voltage
Adjustable sensitivity by Trimpot
1/4” male fast-ons for circuit connection
Conformal coating to protect circuit from harsh environments
Operating Logic: In Model NS141-A10 (Pump Down) the load is de-energized until the liquid reaches the high probe. When liq uid touches the high probe, the load is acti vated until the level drops below the low probe. Model NS141-B10 (Pump Up): The load is energized until the liquid reaches the high probe. When liquid touches the high probe, the load is deactivated until the level drops below the low probe. On both models a red light is activated when the load is off. If the tank is non-con ductive, a third (common) probe must be installed at a level where it will always be submerged.
SPECIFICATIONS
CONTROL TYPE
On/Off Resistance Sensing:
NS141-A10/A100: Probe resistance below set point activates relay NS141-B10/B100: Probe resistance above set point activates relay
Sensing Voltage: 30 VAC, max. RMS Sensing Current: 1 mA, max. RMS Sensitivity Adjustment: Factory set at
50 K ohms, ±20%
ORDERING INFORMATION
Pump Down 120/240 VAC LNC-NS141-A10
Pump Up 120/240 VAC
Pump Down 100/200 VAC
Pump Up 100/200 VAC LNC-NS141-B100
Probe Holder with Ground LLH-11383-010
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
File #E61377
LOGIC TYPE INPUT VOLTAGE PART NUMBER
ACCESSORY PART NUMBER
OUTPUT
Type: Single-pole solid state switch Rating: 16 A 1 hp at 120, 240 VAC Life:
Electrical: 1,000,000 min. at full load
INPUT
Operating Voltage:
NS141-A10: 120 VAC, ±10%, between COM and 120 terminals NS141-B10: 240 VAC, ±10%, between COM and 240 terminals NS141-A100: 100 VAC, ±10%, between COM and 120 terminals NS141-B100: 200 VAC, ±10%, between COM and 240 terminals
Power Consumption:
NS141-A10/B10: 3.0 VA max. NS141-A100/B100: 4.0 VA max.
Frequency: 50/60 Hz
-
-
PROTECTION
Isolation: 1500 VAC between probe and other
terminals Transient Voltage: Protected by a 30 joule metal
oxide varistor
MECHANICAL
Terminations: 1/4” x .032” male fast-ons for
input voltage and load, .187” x .020” fast-ons for probes
Mounting: 2 - 3/16” slots on 3.5” center in alumi-
-
num chassis
ENVIRONMENTAL
Operating Temperature: 0°C to 65°C
LNC-NS141-B10
LNC-NS141-A100