NATIONAL CONTROLS DNC-T2300-I-O User Manual

4-20
L1
L2
FAILURE TO COMPLY WILL VOID ANY
WARRANTY
DO NOT USE SLOW-BLOW OR LARGER SIZE
Model DNC-T2310-010
SOL COM
L1
L2
3AMP
1
2
3 4
OUTPUTS
5 6
7 8
10
9
HI SIDE
CONNECTIONS:
PRESSURE
LOW SIDE
1725 Western Dr.
S/N:
INTELLIGENT DUST CONTROL
West Chicago, IL. 60185
INPUT VOLTAGE:120 VAC, 10VA
MODEL NO.: DNC-T2310-010
Date Code:
BYPASS
INPUT
ALARM
OUTPUT
ALARM
INPUT
INCHES OF WATER
DIFFERENTIAL PRESSURE ( P)
National Controls Corporation
D
OUTPUT
STEP
CANCEL
ALARM
CONNECTOR
RS232
ITEM VALUE
National Controls Corporation
RS-232 Null Modem Cable
T2310 & I/O Board Wiring Diagram
DNC-T2310-010
DNC-T2300-I/O
Network Connection
to DSP-T2300-010
DUST COLLECTOR CONTROLS
Intelligent Dust Collector Controller Remote Input/Output Module
Model DNC-T2300-I/O
FEATURES
Enhances T2310 and T2320 timer oper-
Monitors three switched inputs
Monitors one type J thermocouple
Operating temperature range from
-40°C to 65°C Communicates via RS232 port to intel
ligent controller Communicates via 2 wire network to
remote sites Interconnectable for overall system
management Large storage capacity for historical
trending of system data Aids in system diagnostics
Increases overall system efficiency
Conformally coated for protection against vibration, humidity, and con tamination
Metal chassis provided: for mounting
directly into Timer functionally tested to eliminate
field failures
One Year Warranty:
free from defects in materials or work manship for one year from date of manufacture
NEMA 4 box
warranted to be
File #E65038
non-volatile memory for the storage of up to one year of input trending data. The I/O board requires either a T2310 or T2320 Timer to program and operate the board and a T2300 Display Panel to access data trending reports. The I/O board offers significant versatil
controller’s 8 character display and output via the two wire Enhanced Timer Network to the DNC-T2300-
-
DSP remote display panel. ity to the Intelligent Dust Collector Controller system. It can monitor, display, alert, and store dust collector system parameters from
-
pressure sensors, emission monitors, ple num air flow sensors, broken bag detectors, fan motor current sensors and any other device which has a 4-20 mA current output or contact closure output. The unit works in conjunction with the T2310 and T2320 Timers and also with the DNC-T2300-DSP Display Panel.
Inputs: There are three gener-
al purpose 4-20mA current loop
-
inputs which are configured by the
Timer. Depending on how the par
ticular 4-20 mA inputs are config
ured, the messages that appear
on the Timer’s display would either
show a generic range of 0-100%
based on the 4-20 mA input or
data units specific to three pre-pro
-
-
-
grammed sensing devices would Operating Logic: Upon application of power to the unit, communication will be
-
established with the T2310 or T2320 Timer via the RS232 port. The I/O board can then be configured for the inputs provided to it by using the keypad on the controller. Alarm setpoints and 4-20 mA scaling can be pro grammed for different types of inputs to be displayed in a meaningful fashion on the
be displayed.
There are two general purpose
switched inputs which will moni
tor and report up to two contact
closures as alarm conditions to
the Timer, and one contact clo
-
sure input which allows the user to
place the Enhanced Timer system
in standby mode.
-
-
-
The Model DNC-T2300-I/O module provides several functions. It communicates with a T2310 or T2320 Dust Collector Timer via the RS232 port to form an Enhanced Timer sys tem, and it communicates pertinent system data to remote control/display devices via the 2 wire Enhanced Timer Network. It also incorporates three 4-20 mA current loop inputs, three contact closure type inputs, and one type J thermocouple input. In addi tion, the I/O board provides 16K bytes of
ORDERING INFORMATION
INPUT VOLTAGE PART NUMBER
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
105 to 135 VAC DNC-T2310-A10
210 to 270 VAC
ACCESSORY DIMENSIONS PART NUMBER
Enclosure 10” x 8” x 4” BOX-A1008-CHNF
DNC-T2310-A220
-
-
DUST COLLECTOR CONTROLS
.06 THICK ALUMINUM
MOUNTING PLATE
2 POS. SCREW
TERMINAL
(8 PL.)
2.50 MAX.
RS-232 9 CIRCUIT
MALE CONNECTOR
TO NETWORK
CONNECTION
.25 DIA. MOUNTIN
G
HOLE
(4 PL.)
4-20mA
Inputs
"J" THERMOCOUPLE
Input
CURRENT LOOP SINK
OR SOURCE SWITCH
(SWITCH SHOWN IN
SINK POSITION)
Input Voltage
50/60Hz
4.250
5.000
Switched
Inputs
6.75
6.25
GROUND
RECEIVE DATA
TRANSMIT DATA
6197 8
32 4 5
GROUND
61978
32 4 5
61978
32 4 5
RS-232 Null Modem Cable
Wiring Diagram
RS232 CONNECTORS (TOP VIEW)
9-PIN RS232 D-SUB (PLUG) CONNECTOR
MOUNTED ON CONTROLLER
MATES WITH 9 PIN (RECEPTACLE)
CONNECTOR AMP #747150-1 OR EQUIV.
The I/O board also has the capacity to monitor the temperature of a type J thermo couple in °F, with a range of 40°F to 700°F.
History Trending: The I/O board has the capability to store data generated by the Timer connected to its RS232 port as well as data generated by the various sensing devices connected to its inputs. Data histo ry is subdivided into three categories: Short Term History, Long Term History, and Alarm History. Short Term History is a time and date stamped recording of the hourly averages of the 4-20mA inputs, the Differential Pressure from the Timer, the highest temperature recorded, and the number of outputs that were pulsed in that hour. This Short Term History period is two weeks, after which time the oldest 24 hours of recorded data is averaged along with the highest recorded temperature and the number of outputs that were pulsed for that period and is stored in Long term history. The Long Term History period is one year, after which time the oldest recorded data is discarded to make room for new data. Alarm History is event driven, if any alarm conditions occur, a time and date stamped “snapshot” of all the system parameters is recorded in a First-In-First­Out circular data buffer. This FIFO buffer can store up to 212 alarm events and is not time dependent. In order to generate the Data History Reports, a DNC-T2300-DSP Remote Display Panel and a terminal device capable of communicating standard ASCII via an RS232 connection are required.
SPECIFICATIONS
INPUTS
Voltages: 105-135 VAC, 50/60 Hz; 210-270 VAC,
50/60 Hz
4-20 mA Current Loops:
Input Impedance: 401.5 ohms +20 ohms Accuracy: +1% of applied signal.
#1: Emissions/Aux1 (Sink Capability Only)
User Selectable Functions:
Emissions: Output is percent of full scale input Generic: Output is percent of full scale input
#2: Air Flow/Aux2 (Sink Capability Only)
User Selectable Functions: Air Flow: Pitot Tube sensing device required, output range 0 to 6.5 mega SCFM Generic: Output is percent of full scale input
#3: Manifold/Aux3 (Source or Sink Capability) Source Voltage: +24v
User Selectable Functions:
Manifold pressure: Output range: 0 to 999 psi Generic: Output is Percent of full scale input.
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
+2v
-
-
Switched Inputs:
Alarm Input Open Circuit Voltage: 40 VDC Alarm Input Short Circuit Current: 4.5 mA
#1: Airlock Fault/Aux4 Alarm: Input will be labled and recorded as either Air Flow or Aux4 depending on user selection.
#2: High Hopper/Aux5 Alarm: Input will be labled and recorded as either High Hopper or Aux5 depending on user selection.
#3: Standby Function: Dedicated as a Remote Standby Switch Input.
Thermocouple Input:
Thermocouple: Type J Temp. Measurement Range: -40°F to 700°F Temp. Measurement Accuracy: +4°F
SERIAL COMMUNICATIONS
Null modem type connection required between controller and I/O board.
Type: RS232 Mode: 4800 baud, 8-data bits 1-start bit 1-stop
bit, X ON - X OFF, no parity Function: Dedicated for communication with a
T2300 Series Dust Collector Controller. Connector: 9-pin male IBM-compatible D-SUB
connector. Null modem type connection required between controller and I/O board.
Network Connection:
Type: 2 wire twisted pair Termination: 52.3 ohm, 1%, 1/8 W resistor Network Connection Device: FTT-10A Transceiver
ENVIRONMENTAL
Operating Temperature Range: -40° to 65°C Humidity: 90% non-condensing Environmental Protection: RTV conformal coat
ing for humidity and vibration
Contact factory for additional information
Caution:
1. Do not mount controls in high vibration areas with out shock mounts.
2. Do not mount controls in areas of high dust or cor rosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power source.
4. Do not mount control in high transient voltage areas without an isolation transformer.
-
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the con trols, as we employ some very sophisticated compo nents that could be further damaged. For service, call us directly: 800-323-2593.
4-21
-
-
-
-