DUST COLLECTOR CONTROLS
Pulse Jet Dust Collector Control with Extended Cycle
DNC-T2110 Series
FEATURES
Digital Timing Circuitry: allows for sta-
●
ble timing from -40°C to 65°C tempera
ture range
Pulse Time: line synchronized to elimi
●
nate 8 millisecond triac turn off variation
10 A-400/600V Output Triacs: for maxi
●
mum protection against output shorts;
200 VA load rating
Conformally coated for protection
●
against vibration, humidity, and con
tamination
2 Modes of Operation: can be operated
●
Continuously or On Demand via external
pressure switch
●
Extended cycle capability for added
pulses after pressure switch opens
●
Field Selectable: for numbers of outputs
required
●
LED Indicators: for compartment being
cleaned indication
●
Rugged Timing Adjustments: large sta
ble potentiometers are used for ON and
OFF time adjustments
Metal Chassis Provided: for mounting
●
directly into NEMA 4 box
●
Timer Functionally Tested: to eliminate
field failures
●
Input Protection: 30 joule metal oxide
varistor
One Year Warranty: warranted to be free
●
from defects in materials or workmanship
for one year from date of manufacture
Operating Logic: The DNC-T2110-A10/
B10 are ten output sequencer, cycle tim
ers with adjustable ON-TIME, OFF-TIME
-
and DELAY times. When voltage is applied
to L1 and L2 and the pressure switch is
-
closed, the OFF-TIME is started, At the
end of the preset OFF-TIME the control
-
will cycle through the outputs until the
-
pressure switch opens. The ENABLE/
DISABLE switch on the control can enable
the OFF-DELAY. When the pressure switch
-
opens and the OFF-DELAY is enabled, then
the OFF-DELAY time is started and the
OFF-TIME, ON-TIME cycles will continue
until the end of the OFF DELAY time. If the
OFF-DELAY times out during the ON-TIME,
the control will allow the ON-TIME to time
out. Upon closing of the pressure switch
the control will commence the OFF-TIME,
ON-TIME sequence on the next output and
the OFF-DELAY time will reset. If the pres
sure switch is closed during the OFF-DELAY
time, the control will reset the OFF-DELAY.
-
The ENABLE/DISABLE switch on the con
trol can disable the OFF-DELAY. When the
OFF-DELAY is disabled and the pressure
switch opens, during the ON-TIME, the
control will allow the ON-TIME to time out.
Upon closing of the pressure switch the
control will commence the OFF-TIME, ONTIME sequence on the next output.
LOGIC FUNCTION DIAGRAM
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
3 AMP
Do not use Slow Blow
or larger size. Failure
the Warranty
to comply will void
L2
LINE
L1
ON
POWER
OUTPUTS
(200 VA/OUTPUT MAX)
Line Voltage:105to135 VAC,50-60Hz
3 41 2
COM
line to L2.
105 to 135 volts.In
grounded systems
connect neutral of
Line voltage must be
Corporation
National Controls
SOL.
6 75 8
PROGRAM CONTROL
PRESSURE
SWITCH
sec.
8.5
100
75
150
OFF TIME
180
125
850
4
100
250
ON TIME
sec.
.5 1 5
OFF DELA
Y
1000
400
2
3
550
700
LAST
TO
L1
L2
PRESSURE SWITCH
(SUPPLIED BY CUST.)
PROGRAM WIRE
8.250
8.750
.250
.625
MAX
2.0 MAX
.250 DIA
(4 HOLES)
ENABLE
DISABL
E
2
3
4
5 6
7
8
OUTPUT USED
ATTACH
sec.
9 10
9
10
6.875
6.250
.312
SPECIFICATIONS
TIME DELAY
OFF-Delay Time: Adjustable from 100 sec. +0%,
-50% to 1000 sec. +10%, -0%. OFF Delay Time
can be disabled
ON-Time: Adjustable from 50 to 500 ms
OFF-Time:
Range A: adjustable from 1.5 to 30 seconds
Range B: adjustable from 8.5 to 180 seconds
Repeatability: ±3% over temperature and voltage ranges
INPUT
Operating Voltage: 105 to 135 VAC
Frequency: 50/60 Hz
Power Consumption: 5 VA max.
OUTPUT
Type: Solid state switch (triac)
Switch Rating: 200 VA max. per output, 1.8 VAC
RMS max.; ON state voltage drop 4 mA max.;
OFF state leakage current at 120 VAC
PROTECTION
Transient Voltage: 30 joule metal oxide varistor
Short Circuit Protection: 3 A fuse
ENVIRONMENTAL
Operating Temperature: -40°C to 65°C
Storage Temperature: -40°C to 85°C
DUST COLLECTOR CONTROLS
4-9
ORDERING INFORMATION
PROGRAMMABLE NO.
OF OUTPUTS
1 to 3
ACCESSORY DIMENSIONS PART NUMBER
NEMA 4 Box 10” x 8” x 4” BOX-A1008-CHNF
Pilot Lamp NEMA 4 Rated Red Light ASL-00RED-NEMA 4
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
On/Off Switch NEMA 4 Rated with Legend Plate MSW-0DPST-011
AMETEK NCC offers NEMA 4 type enclosures for mounting our controls. These enclosures are made of heavy gauge steel and have a continuous hinge cover. All seams are continuously welded. The finish is gray hammer-tone enamel inside and out, over phosphatized surfaces.
OFF TIME PART NUMBER
1.5 to 30 sec.
8.5 to 180 sec.
DNC-T2003-A10
DNC-T2003-B10
Caution:
1. Do not mount controls in high vibration areas with
out shock mounts.
2. Do not mount controls in areas of high dust or cor
rosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the con
trols, as we employ some very sophisticated compo
nents that could be further damaged. For service, call
us directly: 800-323-2593.
-
-
-
-