4-4
L1 L2 1 2 3 4 5 6 7 8 9 10
C
Pressure
switch
TIMER #1
voltage
Input
120V
Last
Solenoid
S
S
Solenoid
Last
TIMER #2
C
10987654321L2
L1
Pressure switch
3867-1
11
4
8
13
9
COM
coil
Reset
12
coil
Set
N.C.
COM
1
N.C.
N.O.
N.O.
5
10
14
Alternate action
dual coil latching
relay. Contacts
shown with reset
coil energized last.
DUST COLLECTOR CONTROLS
AC Input, Pulse Cleaning of
Bag House Dust Collectors
Models DNC-T2003 through DNC-T2032
FEATURES
Digital Timing Circuitry: allows for sta-
●
ble timing from -40°C to 65°C tempera
ture range
Pulse Time: line synchronized to elimi
●
nate 8 millisecond triac turn off variation
10 A-400/600V Output Triacs: for maxi
●
mum protection against output shorts.
200 VA load rating
Conformally coated for protection
●
against vibration, humidity, and con
tamination
2 Modes of Operation: can be operated
●
Continuously or On Demand via external
pressure switch
●
Field Selectable: for numbers of outputs
required
●
LED Indicators: for compartment being
cleaned indication
●
Rugged Timing Adjustments: large sta
ble potentiometers are used for ON and
OFF time adjustments
Metal Chassis Provided: for mounting
●
directly into NEMA 4 box
●
Timer Functionally Tested for 24
Hours: to eliminate field failures
Input Protection: 30 joule metal oxide
●
varistor
One Year Warranty: warranted to be free
●
from defects in materials or workmanship
for one year from date of manufacture
●
File #E65038
Program wire allows the user to select the
maximum number of outputs to be acti
vated.
-
Note: Controls are shipped with jumper across pressure switch
terminals
-
-
SPECIFICATIONS
-
TIME DELAY
ON-Time: Adjustable from 50 to 500 ms
OFF-Time:
-
Range A: adjustable from 1.5 to 30 seconds
Range B: adjustable from 8.5 to 180 seconds
Note: Range S designates customer specified time range. Consult
factory for parameters
Repeatability: ±3% over temperature and voltage ranges
INPUT
Operating Voltage: 120 ±10%, 220 ±10% VAC
Frequency: 50/60 Hz
Power Consumption: 2 VA max.
OUTPUT
-
Type: Solid state switch (triac)
Switch Rating: 200 VA maximum per output
PROTECTION
Transient Voltage: 30 joule metal oxide varistor
Short Circuit Protection: 3 A fuse
ENVIRONMENTAL
Operating Temperature: -40°C to 65°C
Storage Temperature: -40°C to 70°C
Operating Logic: The control can function
in 2 modes.
In Continuous Mode, the pressure switch
terminals are shorted. Upon application of
input voltage, the control activates output
#1 after the preset off time. It will continue
to activate outputs sequentially until input
voltage is removed.
In On Demand Mode, the pressure switch
terminals are connected to an isolated set
of contacts of a differential pressure switch.
The control will activate the outputs sequen
tially whenever the pressure switch contacts
are closed. When the pressure switch con
tacts open, the output sequencing stops.
Re-closing of the contacts will cause the
control to resume activating the outputs.
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
-
-

C
A
D
B
.25
.31
.25 Dia. Hole
(4 Pl.)
L1
L2
AC
Voltage
Input
C 1 2
Solenoid Valve
OFF & ON Time
Adjustments
Program Wire-
Determines number
of outputs to be
activated
(4250-2 10/92)
.625
2.0 Max.
.050 Aluminum
Chassis
OFF
ON
3 AMP
# 6 screw typ.
NOTE: Not all components
odel to model.
Pressure Switch InputFor on demand cleaning.
(Controls are shipped
with inputs shorted out)
ORDERING INFORMATION
DUST COLLECTOR CONTROLS
4-5
OUTPUTS
DNC-T2003 THROUGH DNC-T2032 120 VAC INPUT VOLTAGE
DNC-T2006 THROUGH DNC-T2032 220 VAC INPUT VOLTAGE
Note: Special time ranges are available with the following maximum to minimum time ratio restrictions: ON Time–10:1; OFF Time–20:1
Enclosure for DNC-T2003 8” x 6” x 3.5” BOX-A0806-CHNF
Enclosure for DNC-T2006 10” x 8” x 4”
Enclosure for DNC-T2010 10” x 8” x 4”
Enclosure for DNC-T2020 12” x 10” x 5” BOX-A1210-CHNF
Enclosure for DNC-T2032 14” x 12” x 6”
Pilot Lamp NEMA 4 Rated Red Light ASL-00RED-NEMA-4
On/Off Switch NEMA 4 Rated with Legend Plate MSW-0DPST-001
Alternate Action Dual Coil Latch Relay
Socket For Latch Relay
AMETEK NCC offers NEMA 4 type enclosures for mounting our controls. These enclosures are made of heavy gauge steel and have a continuous hinge cover. All seams are continuously welded. The finish is gray hammer-tone enamel inside and out, over phosphatized surfaces.
MAX.
NO. OF
DIMENSIONS
A B C D
SIZE OF
NEMA 4 ENCLS.
REQUIRED
PROGRAMMABLE NO.
OF OUTPUTS
3 6.75 4.875 6.25 4.25 8” x 6” x 3.5” 1-3
6 8.75 6.875 8.25 6.25 10” x 8” x 4” 2-6
10 8.75 6.875 8.25 6.25 10” x 8” x 4” 3-10
20
10.75 8.875 10.25 8.25
12” x 10” x 5”
32 12.75 10.875 12.25 10.25 14” x 12” x 6” 17-32
6 8.75 6.875 8.25 6.25 10” x 8” x 4” 2-6
10 8.75 6.875 8.25 6.25 10” x 8” x 4” 3-10
20
10.75 8.875 10.25 8.25
12” x 10” x 5”
32 12.75 10.875 12.25 10.25 14” x 12” x 6” 17-32
ACCESSORY DIMENSIONS PART NUMBER
ACCESSORY DIMENSIONS PART NUMBER
— KDD-LATCH-120AC
— MSO-0D11P-012
11-20
11-20
OFF TIME PART NUMBER
1.5 to 30 sec.
8.5 to 180 sec.
1.5 to 30 sec.
8.5 to 180 sec.
1.5 to 30 sec.
8.5 to 180 sec.
1.5 to 30 sec.
8.5 to 180 sec.
1.5 to 30 sec.
8.5 to 180 sec.
1.5 to 30 sec.
8.5 to 180 sec.
1.5 to 30 sec.
8.5 to 180 sec.
1.5 to 30 sec.
8.5 to 180 sec.
1.5 to 30 sec.
8.5 to 180 sec.
BOX-A1008-CHNF
DNC-T2003-A10
DNC-T2003-B10
DNC-T2006-A10
DNC-T2006-B10
DNC-T2010-A10
DNC-T2010-B10
DNC-T2020-A10
DNC-T2020-B10
DNC-T2032-A10
DNC-T2032-B10
DNC-T2006-A220
DNC-T2006-B220
DNC-T2010-A220
DNC-T2010-B220
DNC-T2020-A220
DNC-T2020-B220
DNC-T2032-A220
DNC-T2032-B220
BOX-A1008-CHNF
BOX-A1412-CHNF
Caution:
1. Do not mount controls in high vibration areas with
out shock mounts.
2. Do not mount controls in areas of high dust or cor
rosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer.
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the con
trols, as we employ some very sophisticated compo
nents that could be further damaged. For service, call
us directly: 800-323-2593.
-
-
-
-
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com