NATIONAL CONTROLS DNC-2101-020 User Manual

4-2
adjust
On Of
f
Fan Switch
Off
On
Load
Shaker
1.8 sec.- 3 min
fixed
2 minutes
New cycle
DUST COLLECTOR CONTROLS
Intermittent Use Collectors
Model T2101
FEATURES
Simple 4 wire installation
Replaces electromechanical timers
Completely solid state timing and
switching logic High quality locking bushing
potentiometers for timing adjustment
Very low power consumption
Conformally coated for protection against vibration, humidity, and con tamination
LED function lights on PC board
Function indicating lights on T2101-020
Mounts in standard NEMA 4/JIC
enclosures
LOGIC FUNCTION DIAGRAM
File #E65038
Operating Logic: The control is used on intermittent type dust collectors to auto matically activate the shaking mechanism 2 minutes after the fan motor is turned off. Upon removing power from the fan, a 2 minute fixed delay is initiated. At the end of the delay, the shaker output is activated for an adjustable period of 1.8 seconds to 3 minutes. Resetting the control occurs by turning the fan motor on again.
CAUTION: The control must be wired according to the schematic provided.
-
-
SPECIFICATIONS
TIMING
Delay Time: 120 sec. ±10% fixed Shake Time: Adjustable from 1.8 to 180 sec. Repeatability: ±3% over temperature and volt-
age range
INPUT
Operating Voltage: 105 to 135 VAC Power Consumption: 5.5 W plus shaker contac
tor coil power
Frequency: 50/60 Hz
OUTPUT
Type: Solid state switch, 1 A continuous at 1.5 V
below input voltage
TRANSIENT PROTECTION
Input: Transformer and large filter capacity Output: Solid state switch rated for 10 A at 400V
protected by metal oxide varistor; 3 A fuse pro­tects against external short circuit
ENVIRONMENTAL
Operating Temperature: -40°C to 65°C Storage Temperature: -40°C to 70°C
-
ORDERING INFORMATION
DESCRIPTION PART NUMBER
Control on Chassis DNC-T2101-010
Control in Hinged NEMA 4 Box with Functional Lights
NEMA 4 Box 6” x 8” x 4” BOX-A0606-CHNF
Pilot Lamp NEMA 4 Rated Red Light ASL-00RED-NEMA 4
On/Off Switch NEMA 4 Rated with Legend Plate MSW-0DPST-011
AMETEK NCC offers NEMA 4 type enclosures for mounting our controls. These enclosures are made of heavy gauge steel and have a con­tinuous hinge cover. All seams are continuously welded. The finish is gray hammer-tone enamel inside and out, over phosphatized surfaces.
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
DNC-T2101-020
Caution:
1. Do not mount controls in high vibration areas with out shock mounts.
2. Do not mount controls in areas of high dust or cor rosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power source.
4. Do not mount control in high transient voltage areas without an isolation transformer
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the con trols, as we employ some very sophisticated compo nents that could be further damaged. For service, call us directly: 800-323-2593
-
-
-
-
Control Power On
Load On
4.0
6.
0
1.
0
6.0
6.75
7.5
4.875
.75
.312 DIA. 4 HOLES
(4250-1 10/92)
sec. 1801.8
4.625
5.125
.25
5.625
6.125
.2
5
4 HOLES
.25 DIA.
.625
2.125 Max.
Metal Chassis
T2101
1
2
3
4
On
Off
L2
L1
F
S
Fan
Contactor
Coil
Fan Start/Stop Switch
Terminal
Block
N.O. Aux.
Shaker Contactor Coi
l
120 VAC
L1
L2
#6 screw typ.
Shake Time Adjust
1
2
3
4
3A
L1 L2
Model DNC-2101-010
DUST COLLECTOR CONTROLS
4-3
Model DNC-2101-020
Field Wiring Diagram
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com