NatComm Multiple Input Unit User Manual

MULTIPLE INPUT UNIT
Accessory for the T alking Display Unit
Multiple Input Unit
User Guide
For Technical Assist ance
Please Phone: (07) 5596 5128
DESCRIPTION
Our MULTIPLE INPUT UNIT (MIU) accessory has been designed to allow up to 12 separate switches or sensors to be connected to the one Talking Display Unit (TDU).
The Talking Display Unit (TDU) can then play one of up to 12 separate messages, held in its memory, depending on which MULTIPLE INPUT UNIT sensor has been triggered.
This means that :
Sensor 1 when triggered will cause Message 1 to play Sensor 2 when triggered will cause Message 2 to play Sensor 3 when triggered will cause Message 3 to play Sensor 4 when triggered will cause Message 4 to play Sensor 5 when triggered will cause Message 5 to play Sensor 6 when triggered will cause Message 6 to play Sensor 7 when triggered will cause Message 7 to play Sensor 8 when triggered will cause Message 8 to play Sensor 9 when triggered will cause Message 9 to play Sensor 10 when triggered will cause Message 10 to play Sensor 1 1 when triggered will cause Message 11 to play Sensor 12 when triggered will cause Message 12 to play
Each Sensor Trigger will cause the appropriate message to play, as indicated above.
The TDU can only play one message at one time. While the TDU is playing a message, the default settings of MIU allow
it to detect further triggering by the attached sensors and it will hold in buffer up to 10 separate further triggers.
Then when each message is complete, the MIU will instruct the TDU to play the message corresponding to the next triggering action.
MIU is provided with a TWO YEAR FACTOR Y W ARRANTY.
National Communications Page 3
DESCRIPTION Cont.
During Message play MIU can be configured to handle further sensor triggerring in 3 separate modes :
MODE 1 (Default Mode) MIU will STORE up to 10 further triggers and then instruct TDU to play these Messages in trigger order. This is the default mode.
MODE 2 - MIU will IGNORE any further triggering while playing a Message. Triggering will only take place when a Message is NOT PLAYING.
MODE 3 - MIU will INTERRUPT an existing Message. In this situation a trigger during Message Play will cause the existing Message to STOP and the NEW MESSAGE WILL PLAY.
The appropriate MIU Triggering Mode is set by REMOVING JUMPER CONNECTORS which are linking PINS that are accessed through a small hole located on the underside of MIU (see below).
Note : Jumpers are not in order
To Set MODE 1 - Leave all 3 JUMPERS in place.
To Set MODE 2 - Remove JUMPER 1.
To Set MODE 3 - Remove JUMPERs 1 and 2.
Jumper 1 Jumper 3 Jumper 2
MODEL TABLE
The MUL TIPLE INPUT UNIT (MIU) accessory is available in 6 separate configurations :
MIU-4 - Provides input capability for up to 4 (N.O. sensors) MIU-4a - Provides input capability for up to 4 (N.C. sensors)
MIU-8 - Provides input capability for up to 8 (N.O. sensors) MIU-8a - Provides input capability for up to 8 (N.C. sensors)
MIU-12 - Provides input capability for up to 12 (N.O. sensors) MIU-12a - Provides input capability for up to 12 (N.C sensors)
N.O. = For use with Normally Open switches (standard version). N.C. = For use with Normally Closed switches (alternative version).
National Communications Page 5
INSTALLATION
Switches or Sensors connect to the MULTIPLE INPUT UNIT via a female DB25 connector.
A separate male DB25 connector, with exposed terminals is supplied with this unit to allow direct solder connection of cables leading to each sensor.
Each sensor has been allocated two specific pin positions and should be connected to the DB25 connector as per the diagram and table on page 7.
Sensors can be located up to 100m from the MIU unit, or greater than 100m from the MIU if low resistance wiring is used.
Communication: Between the MULTIPLE INPUT UNIT and the TALK­ING DISPLAY UNIT is achieved via a standard 3 pair telephone cable. A short 3 pair telephone cable is supplied with the MIU. This can be substituted if necessary with any 3 pair cable with a length up to 100m.
Power: for the MIU is supplied from the TALKING DISPLAY UNIT via the same 3 pair cable. Note: a separate power adaptor jack has been fitted to the MULTIPLE INPUT UNIT to allow for direct connection of an optional 12VAC or 12VDC input (minimum 300mA, polarity independent).
This additional power input will only be required under the following circumstances :
1) To provide power for the attached sensors, where additional accessory units such as the SPEAKER SWITCHING UNIT or AUDIO SWITCHING UNIT are also used in the same application.
2) Where PIR’s are used with the MULTIPLE INPUT UNIT AND the complete system is to be run direct from a 12V battery source. In this situation, the 12V battery source should be fed to the TDU and the
MIU.
The use of the optional 12VAC or 12VDC input will prevent possibility of ‘Brown Out’ of one or more of the accessories or sensors.
SENSOR DETAILS
Switches for use with the MIU can be Normally Open (standard model) or Normally Closed (alternative model). See models on page 4.
1. NORMALLY OPEN SWITCHES do not need any modification.
2. NORMALLY CLOSED SWITCHES SWITCHES for use with the MIU Alternative Version need to be “normally
closed” and also need to be modified with a current limiting resistor, as per the diagram below :
PIR SENSORS need to have 1k resistors fitted as per the diagram below :
National Communications Page 7
DB25 PIN OUT TABLE
1niP desUtoN 2niP -1hctiwS 41niP +1hctiwS 3niP -2hctiwS 51niP +2hctiwS 4niP -3hctiwS 61niP +3hctiwS 5niP -4hctiwS 71niP +4hctiwS 6niP -5hctiwS 81niP +5hctiwS 7niP -6hctiwS 91niP +6hctiwS 8niP -7hctiwS 02niP +7hctiwS 9niP -8hctiwS 12niP +8hctiwS
01niP -9hctiwS 22niP +9hctiwS 11niP -01hctiwS 32niP +01hctiwS 21niP -11hctiwS 42niP +11hctiwS 31niP -21hctiwS 52niP +21hctiwS
Page 8 National Communications
SPECIFICATIONS
Dimensions (all in mm) : 106 (W) x 106 (D) x 43 (H) Weight : 220g Optional Power Supply : 240V AC to 12VAC or 12VDC Power Connector : 2.5mm barrel connector Power Consumption : Idle - 0.5 Watts Communications Port : RJ 11 6 pin Multiple Sensor Input Port : DB25 Female C-Tick Compliance : Supplier Number N782
WARRANTY
This device is guaranteed against defects from workmanship for a period of two years (24 months) from the date of purchase.
In the event of failure, you should return the product, along with proof of purchase date, and a written statement about the nature of the problem.
The obligation is solely to repair or replace the product. The warrantor is not liable for any incidental or consequential damages due to such defects.
This Warranty shall not apply to any unit which has been subject to alteration, modification, abuse, negligence, accident, external voltage/ lightning surge or used in any manner contrary to these instructions.
The user is responsible for freight costs to the repair point. The warrantor will be responsible for freight costs in returning this unit back to the user.