NatComm LCU1, LCU2, LCU3 User Manual

Model LCU-1 and LCU-2
Lock Control Units
LCU1
LCU2 and LCU3
LCU
Lock Control Unit
For Technical Assistance
Page 2 National Communications
TABLE OF CONTENTS
Product Description LCU1 and LCU2 Pages 3 - 4 Product Description LCU3 Page 5 Installation Procedure Page 6 Programming Notes Page 7 Programming Options AL L Page 8 Programming Options LCU3 only Page 9 Programming LCU1 Page 10 - 11 Programming LCU2 Page 12 - 13 Programming LCU3 Page 14 - 15 Specifications Pages 16 Warranty Information Pages 16
LCU1
LCU2 and LCU3
National Communications Page 3
PRODUCT DESCRIPTION
Our intelligent and programmable Lock Control unit (LCU) is designed to provide for Telephone Line based DTMF controlled switching of 1 or 2 internal Dry Relay Contacts, which can be used to control 1 or more external devices.
They are ideal for applications such as Basic Access Control, Lift Control or the Powering ON, OFF or RESET of One or More Electrical devices.
Model LCU1 - provides for control of 1 Dry Relay contact Model LCU2 - provides for independent control of 2 Dry Relay contacts Model LCU3 - provides Auto Answer operation with 2 Dry Relay contacts
The Relay Contacts are rated for 12volts, 1amp. Our LCU units connect (in Parallel) to ANY Telephone Line and listen and
respond to programmed DTMF Touch Tone commands. Each LCU has One (LCU1) or Two (LCU2) Dry Relay contacts that can be
independently controlled by DTMF Touch Tone commands from an Incoming Telephone Call OR they can respond to Any Parallel telephone device connected to the same line.
Model LCU3 also has Two Dry Relay contacts and this Model can be set to Answer Incoming calls after a User Programmable number of rings (See page 5 for more details on LCU3).
One or More LCU units can be fitted to the same telephone line to provide a simple and flexible Access Control or Power Control solution.
Each LCU Relay can be programmed with its own unique DTMF code (from 1-4 digits) and whenever the correct code is entered from Any telephone on that line, or from an Incoming Telephone Call, the appropriate Relay will close for a User Programmable period of time (programmable from 1-99 seconds).
LCU units connect to ANY telephone socket on a telephone line. Multiple units can connect to the same socket, or they can be connected to different sockets on the same line.
LCU is supplied with a 12VAC power adaptor. 12VDC can alternatively be used to power LCU if required (min of 200mA).
Page 4 National Communications
PRODUCT DESCRIPTION
LCU is designed to connect in PARALLEL to a telephone line. It has a single RJ11 (6 pin) Telephone Line input port.
Model LCU1 provides One 4 pin RJ port to connect to the internal relay. Models LCU2 and LCU3 provides Two 4 pin RJ ports to connect to the internal
relays. Connection Box(s) are supplied with short leads for easy connection to LCU. Each Connection Box has 2 Screw Terminals to provide for connection of
your electrical equipment to the Internal Relays of LCU. Once installed, LCU will automatically respond to any 1,2,3 or 4 digit DTMF
code that is programmed by the user. LCU responds to all DTMF commands, ie: 0-9,*,#,A,B,C &D.
The closure time of the relay can also be set by the user for periods of 01 to 99 seconds. If a setting of 00 is entered, LCU will provide latching of the relay on a toggle basis, so that equipment (such as a 12V light, Video equipment etc) can be switched ON or OFF as required.
LCU can also be set to respond to DMTF commands from Incoming calls only, or Incoming and Outgoing calls (default setting).
LCU's can also be programmed to respond to a set code within a dialed sequence.
For example, a Door Phone could call a specific business within a Multi Tenanted Office Building. The operator after answering could then Dial 123456 and then hang up.
One LCU relay set to respond to 12 could open the front door for 15 seconds. A second LCU relay set to respond to 34 could alert the Elevators to allow access to Floor 3. A third LCU relay set to respond to 56 could release the Door Strike which allows access to offices on Floor 3.
LCU is provided with a Two Year Factory Warranty.
National Communications Page 5
PRODUCT DESCRIPTION LCU3
LCU3 provides all of the features described on pages 3-4. Please read these pages first.
Model LCU3 has the additional ability of being able to Answer an Incoming call on a telephone line, after a user selectable number of rings (0-20 rings).
Setting 0 Rings, disable the Auto Answer facility. The Default setting is that LCU3 will Answer incoming calls after 2 rings. After Answering a telephone call, LCU3 will ‘listen’ for DTMF Commands. If
a programmed command is detected, LCU3 will close one or both of its Internal relays, depending on User Programming, exactly the same as LCU1 and LCU2.
Our LCU1 and LCU2 models do not answer calls. They respond to DTMF commands made during an outgoing call, or an incoming call answered by another device on the line, such as LCU3, Answering Machine or other suitable answering device.
Multiple LCU1 and LCU2 units can be used with LCU3 to provide for Basic Access Control, Lift Control or the Powering ON, OFF or RESET of One or More Electrical devices.
ADDITIONAL LCU3 PROGRAMMING FEATURES
1. LCU3 can be programmed by simply calling in to it. When it answers, press ### to enter programming mode. Note it cannot be programmed if the Auto Answer facility is disabled.
2. LCU3 can have all of its program setting returned to default, by dialling into it, entering ### (to enter program mode) and after hearing the confirmation ‘beep’, pressing 13579.
3.LCU3 has an additional MAXIMUM CALL TIME Programming feature which must be set during the programming procedure.This is the amount of time that LCU3 will hold a call waiting for commands after answering. The default setting is 20 seconds, which is the minimum setting. This can be increased up to 99 seconds if required. See pages 14-15 for full programming details.
Page 6 National Communications
INSTALLATION PROCEDURE
1. LCU must be connected in P ARALLEL on the telephone line on which it is to be used.
2. Your telephone line should connect to the LINE IN port of LCU.
3. Connect the supplied Connection Box(s), using the short cables provided, to the RELA Y 1 port of LCU1 and also to the RELAY 2 port of LCU2 and LCU3.
These Connection Boxes provide for convenient screw terminal access to the Internal Relay(s).
RELAY 1 - Connect your Electrical Device (that requires relay control) to the RED and GREEN terminals of the supplied Junction Box. This relay is rated at 12V/1A.
RELAY 2 - Connect your Electrical Device (that requires relay control) to the RED and GREEN terminals of the other supplied Junction Box. This relay is rated at 12V/1A.
4. Connect the supplied 12VAC Power Adaptor and installation is complete.
5. Program your LCU unit to meet your requirements
(see following pages)
For technical assistance, please contact National Communications on (07) 55965128, 9AM to 5PM Monday - Friday (QLD TIME).
National Communications Page 7
PROGRAMMING NOTES
LCU is programmed via DTMF commands entered from any telephone connected to the same line.
Y ou can only program LCU by entering ### during the first 30 seconds after power is connected to the unit.
The following notes provide important information about the programming procedure :
1) To enter PROGRAMMING MODE you must turn OFF POWER to your unit and then switch POWER ON AGAIN.
2) Using ANY TELEPHONE connected to the TELEPHONE LINE, PRESS ### within 30 SECONDS.
3) You will hear 3 short ‘beeps’ to confirm you are in programming mode.
4) Individual Parameter Programming Entries are carried out by pressing further keys on the attached telephone.
5) Your unit will generate 1 short ‘beep’ to confirm acceptance of command.
6) Your unit will generate 1 long ‘beep’ to advise of an entry error.
7) If 1 long ‘beep’ is detected, your command should be repeated.
8) You can Program Lock 1 or Lock 2 (model LCU2 and LCU3 only) individually by pressing :
Press #1 for setting Lock 1 parameters Press #2 for setting Lock 2 parameters
LCU3 PROGRAMMING
LCU3 is programmed by calling in to it. When it answers, press ### to enter programming mode. Note it cannot be programmed if the Auto Answer facility is disabled.
Page 8 National Communications
PROGRAMMING OPTIONS ALL
LCU has internal flash memory which will retain your settings even if power is disconnected. The following settings are provided :
1. SETTING DTMF RELA Y CONTROL CODE
A 1 to 4 digit DTMF CONTROL CODE can be set to trigger the LCU relay response. Model LCU2 and LCU3 provides for 2 relay output. Each relay must use a separate Control Code.
Allowable Range : 1,2,3 or 4 digits Default Setting Lock 1 is : *3 Default Setting Lock 2 is : *4
2. RELA Y CLOSURE TIME
Upon detection of the correct DTMF Relay Control Code, LCU can close for a period up to 99 seconds.
Allowable Range : 01 – 99 seconds Default Setting is : 5 seconds
Model LCU2 and LCU3 provides for 2 relay output. Each relay can have different closure times, or the same closure time.
3. INCOMING CALL and OUTGOING CALL operation
LCU is set by default to respond to DTMF commands from both incoming calls and outgoing calls. You can also restrict it to respond to incoming calls only.
Respond to : Incoming calls only OR Incoming and Outgoing calls
Default Setting is : Respond to Incoming and Outgoing calls
4. RESPOND TO PROGRAMMED DIGITS IN A SEQUENCE
LCU will normally only respond to the set DTMF Control Code providing there are no other DTMF digits before or after it, within 3 seconds. It can however be set to respond to the exact set number when there are other DTMF digits before or after it.
Default Setting is : Respond only when there are no digits
before or after the set code.
PROGRAMMING OPTIONS LCU3
LCU3 has the following additional Program capability :
LCU3 can ALSO be programmed by simply calling in to it OR it can also be programmed in exactly the same manner as LCU1 and LCU2 with a telephone connected in parallel on the same line.
LCU3 has the following additional Program settings :
5. SETTING MAXIMUM AUTO ANSWER CALL TIME
This is the amount of time that LCU3 will hold a call waiting for commands after answering. The default setting is 20 seconds, which is the minimum setting. This can be increased up to 99 seconds if required.
Allowable Range : 20 – 99 seconds Default Setting is : 20 seconds
6. SETTING NUMBER OF RINGS TO ANSWER
This is the number of rings LCU3 must detect before it will answer a call. The Default settings is 2 rings. If you wish to Turn OFF the Automatic Answer facility set the number of rings to 00.
Allowable Range : 00-20 rings Default Setting is : 02 rings
7. RESET FACTOR Y DEFAULTS
LCU3 can have all of its program setting returned to default, by dialling into it, entering ### (to enter program mode) and after hearing the confirmation ‘beep’, pressing 13579.
National Communications Page 9
PROGRAMMING LCU1
1. TURN OFF POWER TO YOUR UNIT FOR MINIMUM of 5
SECONDS
2. SWITCH ON POWER AND PRESS ### (WITHIN 30 SECONDS)
You must use a telephone connected to the TELEPHONE LINE that LCU is connected to.
3. YOUR UNIT WILL OUTPUT 3 SHORT ‘BEEPS’
Do not proceed until you have heard 3 short beeps. If you do not hear 3 beeps, return to the start (1).
4. PRESS #1 to program Relay 1
You should hear 1short beep If you do not hear 1 beep, return to the start (1).
5. a) Enter 1, 2, 3 or 4 (this is number of DTMF digits in PIN)
then b) Enter your 1, 2, 3 or 4 digit PIN
eg; If your PIN is 3579, you should enter 4 then 3579 eg; If your PIN is #7, you should enter 2 then #7
You should hear 1short beep If you do not hear 1 beep, return to the start (1).
6. ENTER REQUIRED RELAY CLOSURE TIME
Enter 2 digits only (01 to 99) seconds You should hear 3 short beeps If you do not hear 3 beeps, return to the start (1).
You can now :
a) Program LCU to respond to INCOMING calls only b) Program LCU to respond to YOUR CODE within a group of
digits.
Go to page 1 1 O R
c) Hang Up if your programming is complete
Page 10 National Communications
PROGRAMMING LCU1
7. DO YOU REQUIRE LCU1 TO RESPOND TO INCOMING CALLS ONLY
PRESS #3x x = 0 To respond to Incoming calls only x = 1 To respond to Incoming and Outgoing calls (DEFAULT)
8. DO YOU REQUIRE LCU1 TO RESPOND TO PIN within a Sequence
PRESS #4x x = 0 To respond to exact code only (DEFAULT) x = 1 To respond to exact code within a group of digits
9. PROGRAMMING COMPLETE - HANG UP
National Communications Page 11
PROGRAMMING LCU2
1. TURN OFF POWER TO YOUR UNIT FOR MINIMUM of 5
SECONDS
2. SWITCH ON POWER AND PRESS ### (WITHIN 30 SECONDS)
You must use a telephone connected to the TELEPHONE LINE that LCU is connected to.
3. YOUR UNIT WILL OUTPUT 3 SHORT ‘BEEPS’
Do not proceed until you have heard 3 short beeps. If you do not hear 3 beeps, return to the start (1).
4. PRESS #1 to program Relay 1
You should hear 1short beep If you do not hear 1 beep, return to the start (1).
5. a) Enter 1, 2, 3 or 4 (this is number of DTMF digits in PIN)
then b) Enter your 1, 2, 3 or 4 digit PIN
eg; If your PIN is 3579, you should enter 4 then 3579 eg; If your PIN is #7, you should enter 2 then #7
You should hear 1short beep If you do not hear 1 beep, return to the start (1).
6. ENTER REQUIRED RELA Y CLOSURE TIME
Enter 2 digits only (01 to 99) seconds You should hear 3 short beeps If you do not hear 3 beeps, return to the start (1).
If you do not intend to use Relay 2, proceed to step 10
7. PRESS #2 to program Relay 2
If you do not hear 1 beep, return to the start (1).
8. a) Enter 1, 2, 3 or 4 (this is the number of DTMF digits in PIN)
then b) Enter your 1, 2, 3 or 4 digit PIN
eg; If your PIN is 9, you should enter 1 then 9 eg; If your PIN is 123, you should enter 3 then 123
You should hear 1short beep If you do not hear 1 beep, return to the start (1).
Page 12 National Communications
PROGRAMMING LCU2
9. ENTER REQUIRED RELA Y CLOSURE TIME
Enter 2 digits only (01 to 99) seconds You should hear 3 short beeps If you do not hear 3 beeps, return to the start (1).
You can now :
a) Program LCU to respond to INCOMING calls only b) Program LCU to respond to YOUR CODE within a group of
digits.
Proceed Below OR
c) Hang Up if your programming is complete
If you do not need to make any further changes, proceed to step 12
10. DO YOU REQUIRE LCU2 TO RESPOND TO INCOMING CALLS ONL Y
PRESS #3x x = 0 To respond for Incoming calls only x = 1 To respond to Incoming and Outgoing calls (DEFAULT)
11. DO YOU REQUIRE LCU2 TO RESPOND TO PIN within a Sequence
PRESS #4x x = 0 To respond to exact code only (DEFAULT) x = 1 To respond to exact code within a group of digits
12. PROGRAMMING COMPLETE - HANG UP
National Communications Page 13
DIAL IN PROGRAMMING LCU3
LCU3 can be programmed by simply calling in to it OR it can also be programmed in exactly the same manner as LCU1 and LCU2 with a telephone connected in parallel on the same line.
1A. DIAL INTO LCU3. Press ### after it answers.
OR
1B) TURN LCU3’s POWER OFF for a minimum of 5 seconds and
then Turn power ON again. Then press ### within 30 seconds to enter programnming mode.You must use a telephone connected to the Telephone LIne that LCU3 is connected to.
2. YOUR UNIT WILL OUTPUT 3 SHORT ‘BEEPS’
Do not proceed until you have heard 3 short beeps. If you do not hear 3 beeps, return to the start (1).
3. PRESS #1 to program Relay 1
You should hear 1short beep If you do not hear 1 beep, return to the start (1).
4. a) Enter 1, 2, 3 or 4 (this is number of DTMF digits in PIN)
then b) Enter your 1, 2, 3 or 4 digit PIN
eg; If your PIN is 3579, you should enter 4 then 3579 eg; If your PIN is #7, you should enter 2 then #7 You should hear 1short beep If you do not hear 1 beep, return to the start (1).
5. ENTER REQUIRED RELA Y CLOSURE TIME
Enter 2 digits only (01 to 99) seconds You should hear 3 short beeps If you do not hear 3 beeps, return to the start (1).
If you do not intend to use Relay 2, proceed to step 9
6. PRESS #2 to program Relay 2
If you do not hear 1 beep, return to the start (1).
7. a) Enter 1, 2, 3 or 4 (this is the number of DTMF digits in PIN)
then b) Enter your 1, 2, 3 or 4 digit PIN
eg; If your PIN is 9, you should enter 1 then 9 eg; If your PIN is 123, you should enter 3 then 123 You should hear 1short beep If you do not hear 1 beep, return to the start (1).
Page 14 National Communications
8. ENTER REQUIRED RELA Y CLOSURE TIME
Enter 2 digits only (01 to 99) seconds You should hear 3 short beeps If you do not hear 3 beeps, return to the start (1).
9. ENTER MAXIMUM AUTO ANSWER CALL TIME
This is the amount of time that LCU3 will hold a call waiting for commands after answering. The default setting is 20 seconds, which is the minimum setting. This can be increased up to 99 seconds if required.
PRESS #6 to program Maximum Call Time
If you do not hear 1 beep, return to the start (1). Enter 2 digits only (20 to 99) seconds
You should hear 3 short beeps If you do not hear 3 beeps, return to the start (1).
You can now :
a) Program LCU to respond to INCOMING calls only b) Program LCU to respond to YOUR CODE within a group of
digits. Proceed Below OR
c) Hang Up if your programming is complete
10. DO YOU REQUIRE LCU3 TO RESPOND TO INCOMING CALLS ONL Y
PRESS #3x x = 0 To respond for Incoming calls only x = 1 To respond to Incoming and Outgoing calls (DEFAULT)
11. DO YOU REQUIRE LCU3 TO RESPOND TO PIN within a Sequence
PRESS #4x x = 0 To respond to exact code only (DEFAULT) x = 1 To respond to exact code within a group of digits
12. DO YOU WANT T O CHANGE THE NUMBER OF RINGS TO ANSWER OR
DISABLE AUTOANSWER PRESS #0xx xx = 00-20 Rings
To change Autoanswer to 5 rings, enter 05 To change Autoanswer to 15 rings, enter 15 To Disable Autoanswer, enter 00
13. PROGRAMMING COMPLETE - HANG UP
National Communications Page 15
Page 16 National Communications
SPECIFICATIONS
Dimensions(all i n m m ) : 106 (W) x 106 (D) x 43 (H) Weight : 225g Power Supply : 12VAC/500mA Power Consumption : Idle - 0.5 Watts Power Consumption : Call - 0.75 Watts Ringer Equivalence : 0.3 REN Line In Connector : RJ 1 1 6 pin (2 centre) RELAY 1 Connector : RJ 11 4 pin (2 centre) RELAY 2 Connector : RJ 11 4 pin (2 centre) Power Connector : 2.5mm barrel connector ACMA COMPLIANT : Supplier Number N 782
WARRANTY
This device is guaranteed against defects from workmanship for a period of two years (24 months) from the date of purchase. In the event of failure, you should return the product, along with proof of purchase date, and a written statement about the nature of the problem.
This Warranty shall not apply to any unit which has been subject to alteration, modification, abuse, negligence, accident, external voltage/ lightning surge or used in any manner contrary to these instructions.
The obligation is solely to repair or replace the product. The warrantor is not liable for any incidental or consequential damages due to such defects.
The user is responsible for freight costs to the repair point. The warrantor will be responsible for freight costs in returning this unit back to the user.
Damage caused to this device or attached equipment, by lightning strikes or over voltage surge is not covered under this warranty .
CASE SEALED AT FACTORY
OPENING THE CASE VOIDS THE WARRANTY