Nascom N1178CTG-SW, N1178CTB-STHS, N1178CTW-SWHS, N1178CTW-SWFB, N1178CTW-SW Specsheet

...
N1178CT
3/4” RECESSED WIDE GAP STUBBY DOOR CONTACT SET
Nascom’s N1178C Series is a 3/4” recessed wide gap stubby door contact de­signed for residential, commercial and industrial steel and wood door applications.
The N1178C is the installer’s choice of contact conguration because the contact
set is designed to cut installation times and helps to prevent false alarms caused by shifting or warping doors.
The N1178C Series is designed for installation in every type of hinged door.
FEATURES
SNAP FIT ON STEEL - NO GLUE REQUIRED ENCAPSULATED HERMETICALLY SEALED CONTACTS
SCREW TERMINALS POLYPROPYLENE HOUSINGS
WIDE GAP - N35 NdFeB RARE EARTH MAGNET LISTED TO UL634 STANDARD
ORDERING INFORMATION
CONTACT RATING
PART
NUMBER
COLOR
OPERATE
GAP
(in inches)
(Max DC/Peak AC Resistive)
SWITCHING CARRY
V I V I
CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:
N1178CTB/ST N1178CTG/ST N1178CTT/ST N1178CTW/ST
OPEN LOOP, NORMALLY CLOSED, 1FB, SWITCH/MAGNET SET:
N1178CTB/STFB N1178CTG/STFB N1178CTT/STFB N1178CTW/STFB
HIGH SECURITY, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:
N1178CTB/STHS N1178CTG/STHS N1178CTT/STHS N1178CTW/STHS
BROWN GREY TAN WHITE
BROWN GREY TAN WHITE
BROWN GREY TAN WHITE
0.875 to 1.50 200 VDC 0.5 Amps 10vA 1.5 Amps 150 mOhms
0.75 to 1.25 30 VDC 0.2 Amps 3vA 0.5 Amps 150 mOhms
0.1875 to
0.5000
300 VDC
0.25
Amps
10vA
0.25
Amps
STATIC
CONTACT
RESISTANCE
(50mV, 100mA)
150 mOhms
initial
Royne Industries LLC, dba NASCOM
|
P: 800.843.5530
|
F: 800.727.4041
|
www.nascominc.com
DWG No. 120119-02 Rev. 2
1
.910
23.11
.730
18.54
.480
12.19
1.190
30.23
.805
20.45
.435
11.05
.060
1.52
FRONT VIEW
TOP VIEW
.660
16.76
.060
1.52
.435
11.05
.910
23.11
.730
18.54
.480
12.19
FRONT VIEW
TOP VIEW
WIRING SCHEMATIC
N1178CT
3/4” RECESSED WIDE GAP STUBBY DOOR CONTACT SET
CLOSED LOOP, NORMALLY OPEN CONTACT
DIMENSIONS - IN [mm]
SWITCH
SWITCH CONTACT
SWITCH CONTACT
OPEN LOOP, NORMALLY CLOSED CONTACT
MAGNET
INSTALLATION INSTRUCTIONS
Mark location for the switch on the door frame and mark the location for the magnet on the door.
Make sure switch and magnet hole locations are aligned.
Drill holes for the switch and magnet using a 3/4” Hole Saw for steel doors or a Forstner bit for wood doors.
Press the magnet into the hole in the door until seated rmly against the head. Silicone may be used to secure the magnet in wood doors.
Connect the switch terminals to the alarm circuit conductors. Insert wire leads into hole followed by the switch and press
the switch into the hole until the head is ush with the door frame.
Test switch for correct operation and make sure gap performance is acceptable.
Royne Industries LLC, dba NASCOM
|
P: 800.843.5530
|
F: 800.727.4041
|
www.nascominc.com
DWG No. 120119-02 Rev. 2
2