Nascom N1175UM123787WP-ST, N1175UM123787TP-ST, N1175UM123787GP-ST, N1175UM123787BP-ST Specsheet

Page 1
N1175 UM 123787P
3/8” RECESSED ULTRA MINI CONTACT WITH OVERMOLDED NdFeB BAR MAGNET
Nascom’s N1175 UM 123787P Series, ultra-mini 3/8” recessed contact with NdFeB bar manget, protects all nonferrous (e.g. wood, aluminum and vinyl) doors and windows, in both residential and commercial settings.
The N1175 UM 123787P, our shortest 3/8” press t switch, is the installer’s choice of contact conguration where drill depth is critical and excellent air
and side-to-side gaps are required to prevent false alarms caused by shifting or warping doors and windows.
FEATURES
• PRESS FIT SWITCH - NO GLUE REQUIRED • ENCAPSULATED HERMETICALLY SEALED CONTACTS
• 12” 22AWG WIRE LEADS • POLYPROPYLENE SWITCH HOUSING
• ABS OVERMOLDED MAGNET • LISTED TO UL634 STANDARD
• WIDE GAP - N35 NdFeB RARE EARTH MAGNET
ORDERING INFORMATION
CONTACT RATING
PART
NUMBER
COLOR
OPERATE
GAP
(in inches)
(Max DC/Peak AC Resistive)
SWITCHING CARRY
V I V I
CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:
N1175UM123787BP/ST N1175UM123787GP/ST N1175UM123787WP/ST
HIGH SECURITY, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:
N1175UM123787BP/STHS N1175UM123787GP/STHS N1175UM123787WP/STHS
BROWN GREY WHIITE
BROWN GREY WHIITE
0.40 to 0.75 200 VDC 0.5 Amps 10vA 1.5 Amps 150 mOhms
0.1875 to 0.50 300 VDC
0.25
Amps
WIRING SCHEMATIC - IN [mm]
SWITCH CONTACT
CLOSED LOOP, NORMALLY OPEN CONTACT
10vA
0.25
Amps
STATIC
CONTACT
RESISTANCE
(50mV, 100mA)
150 mOhms
initial
Royne Industries LLC, dba NASCOM
|
P: 800.843.5530
|
F: 800.727.4041
|
www.nascominc.com
DWG No. 140117-01- Rev. 1
1
Page 2
.540
13.72
.030
0.76
.355
9.02
.455
11.56
TOP VIEW
FRONT VIEW
.015
0.38
.195
4.95
3M VHB TAPE
1.000
25.40
.500
12.70
END VIEW
TOP VIEW
DIMENSIONS - IN [mm]
N1175 UM 123787
3/8” RECESSED ULTRA MINI CONTACT WITH NdFeB BAR MAGNET
SWITCH
MAGNET
INSTALLATION INSTRUCTIONS
• Mark location for the switch on the door frame and mark the location for the magnet on the top edge of the door.
• Using a square, transfer the marks on to the top edge of the door and the opposing door frame.
• Using a tape measure or graduations on the square, locate the center of the door edge and place an intersecting line with
the rst mark. Remove the release liner for the VHB tape on the back of the magnet and position the end of the magnet
at the intersecting line.
• Repeat the above step to locate the hole position for the switch in the door frame. Drill a 3/8” hole in the door frame.
• Align the end fo the magnet to the switch body.
• Connect the switch leads to the alarm system. Caution! Hold wire leads, not the switch housing while cutting and
stripping to prevent damage to switch.
• Insert wire leads into hole followed by the switch and press the switch into the hole until the head is ush with the door
frame
• Test switch for correct operation and make sure gap performance is acceptable.
Royne Industries LLC, dba NASCOM
|
P: 800.843.5530
|
F: 800.727.4041
|
www.nascominc.com
DWG No. 140117-01 Rev. 1
2
Page 3
PART NUMBERING SYSTEM
N1175 UM 123787
3/8” RECESSED ULTRA MINI CONTACT WITH NdFeB BAR MAGNET
COLOR:
• W = WHITE
• B = BROWN
• G = GREY
CIRCUIT (0 or 2 digits):
• Blank = CLOSED LOOP
• HS = HIGH SECURITY
N1175UM123787
X ST XX/ XXXX X
P
WIRE TYPE (0 or 1 digit):
• Blank = UL1061 | 22AWG | 7/30
• Z = Zipcord ZIP NEC (UL) TYPE CL2
LEAD LENGTH (zero, 3 or 4 digits):
• Blank - 12 Inches
• All other lengths specied in Inches with 3 digits (e.g. 036 = 36 Inches)
Royne Industries LLC, dba NASCOM
|
P: 800.843.5530
|
F: 800.727.4041
|
www.nascominc.com
DWG No. 140117-01 Rev. 1