RECESSED 3/4” ROLLERBALL STUBBY CONTACT
DESCRIPTION
Nascom’s N005 Series is stubby 3/4” recessed roller ball plunger, designed to
protect all nonferrous (e.g. wood, aluminum and vinyl) doors and windows, in
both residential and commercial settings.
The N005 is the installer’s choice of contact conguration where drill depth is
critical.
FEATURES
• 12” 22AWG WIRE LEADS • ENCAPSULATED HERMETICALLY SEALED CONTACTS
• LISTED TO UL634 STANDARD • ABS HOUSINGS
ORDERING INFORMATION
CONTACT RATING
PART
NUMBER
COLOR
(Max DC/Peak AC Resistive)
SWITCHING CARRY
V I V I
CLOSED LOOP, NORMALLY OPEN, 1FA, SWITCH/MAGNET SET:
N005B/ST
N005W/ST
BROWN
WHIITE
200 VDC 0.5 Amps 10vA 1.5 Amps 150 mOhms
STATIC
CONTACT
RESISTANCE
(50mV, 100mA)
N005
WIRING SCHEMATIC
SWITCH
CONTACT
CLOSED LOOP,
NORMALLY OPEN CONTACT
Royne Industries LLC, dba NASCOM
|
P: 800.843.5530
|
F: 800.727.4041
|
www.nascominc.com
DWG No. 131125-12 Rev. 1
1
1.175
29.85
.225[5.72]
X 65°, NEAR SIDE
.150[3.80] THRU ALL
1.525
38.74
.895
22.73
.750
19.05
.890
22.61
.065
1.65
12.00
304.80
1.190
30.23
1.225
31.12
1.175
29.85
.750
19.05
.135
3.43
1.525
38.74
.895
22.73
.095
2.41
SPACER
DIMENSIONS - IN [mm]
N005
RECESSED 3/4” ROLLERBALL STUBBY CONTACT
INSTALLATION INSTRUCTIONS
• On the hinge jamb of the door, measure out from the door stop half the thickness of the door and make a mark at the
height you want to install the switch.
• Drill a 3/4” hole at the marked location, through the jamb and deep enough to access the alarm circuit wiring.
• Test t the switch in the hole to make sure the switch will seat against the mounting ange. Close the door and measure
the space between the door and the hinge jamb. If the space is greater than 1/4”, you will need to install the enclosed
spacer under the mounting ange of the switch.
• Connect the switch leads to the alarm system circuit. Caution! Hold wire leads, not the switch housing while cutting and
stripping to prevent damage to switch.
• Mark the mounting screw locations and drill the mounting screw holes using a drill adequately sized for #6 Self-tapping
screws.
• Install screws and tighten to mount the switch on the door.
• Test the system for correct operation.
Royne Industries LLC, dba NASCOM
|
P: 800.843.5530
|
F: 800.727.4041
|
www.nascominc.com
DWG No. 131125-12 Rev. 1