NARDA PMM 6000N User Manual

NARDA Safety Test Solutions
Sales & Support:
Via Leonardo da Vinci, 21/23 20090 Segrate (MI) -
ITALY
Tel.: +39 02 2699871 Fax: +39 02 26998700
Manufacturing Plant:
Via Benessea, 29/B
17035 Cisano sul Neva (SV)
Tel.: +39 0182 58641 Fax: +39 0182 586400
http://www.narda-sts.it
SERIAL NUMBER OF THE INSTRUMENT
You can find the Series Number on the rear panel of the instrument. Series Number is in the form: 0000X00000. The first four digits and the letter are the Series Number prefix, the last five digits are the Series Number suffix. The prefix is the same for identical instruments, it changes only when a configuration change is made to the instrument. The suffix is different for each instrument.
Document 6000NEN-90404 – Copyright © NARDA 2007
User’s Manual
PMM 6000N
WIDEBAND RF POWER
AMPLIFIER
9 kHz - 230 MHz / 10 Watts
II Note and symbols
NOTE:
If the instrument is used in any other way than as described in this Users Manual, it may become unsafe Before using this product, the related documentation must be read with great care and fully understood to
familiarize with all the safety prescriptions. To ensure the correct use and the maximum safety level, the User shall know all the instructions and
recommendations contained in this document. This product is a Safety Class I and Installation Category II instrument according to IEC classification
and has been designed to meet the requirements of EN61010-1 (Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use).
This product has a Pollution Degree II normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected.
The information contained in this document is subject to change without notice.
KEY TO THE ELECTRIC AND SAFETY SYMBOLS:
You now own a high-quality instrument that will give you many years of reliable service. Nevertheless, even this product will eventually become obsolete. When that time comes, please remember that electronic equipment must be disposed of in accordance with local regulations. This product conforms to the WEEE Directive of the European Union (2002/96/EC) and belongs to Category 9 (Monitoring and Control Instruments). You can return the instrument to us free of charge for proper environment friendly disposal. You can obtain further information from your local Narda Sales Partner or by visiting our website at www.narda-sts.it .
Warning, danger of electric shock
Earth
Read carefully the Operating Manual and its instructions, pay attention to the safety symbols.
Unit Earth Connection
Earth Protection
Equipotential
KEY TO THE SYMBOLS USED IN THIS DOCUMENT:
DANGER
The DANGER sign draws attention to a potential risk to a person’s safety. All the precautions must be fully understood and applied before proceeding.
WARNING
The WARNING sign draws attention to a potential risk of damage to the apparatus or loss of data. All the precautions must be fully understood and applied before proceeding.
CAUTION
The CAUTION sign draws attention against unsafe practices for the apparatus functionality.
NOTE:
The NOTE draw attention to important information.
Contents III
Contents
General safety considerations and instructions.........
EC Conformity Certificate………………………………... 1 General information
1.1 Documentation.....................................…...............…
1.2 Introduction ……………….....................................….
1.3 Instrument items..............................…................……
1.4 Optional accessories.....…...........………………...….
1.5 Main specifications............................…...............…..
1.6 Typical Performances………………………………….
1.7 Front panel.............……………........….......….....……
1.8 Rear panel………….........................….......….....……
Page
V VI
Page
1-1 1-1 1-1 1-1 1-2 1-3 1-6 1-6
2 Installation
2.1 Introduction.......................................…..................…
2.2 Initial inspection.................................….................…
2.3 Packing and unpacking....................…..................…
2.4 Preparation for use.........................….....................…
2.5 Installation check list......................….....................…
2.6 Line voltage selection.....................….....................…
2.7 Fuse selection..................................…......................
2.8 Power cable........................................…....................
2.9 Environment.....................................…......................
2.10 Return for service..........................…...................….
2.11 Equipment cleaning.......................…....................…
2.12 Hardware installation...................….....................….
Page
2-1 2-1 2-1 2-1 2-1 2-1 2-2 2-2 2-2 2-2 2-2 2-2
3 Operating Instruction
3.1 Cooling.................................................…..................
3.2 Damage precautions.............................….................
3.3 Connection to power source................…..................
3.4 Front panel indicators..........................…..................
3.5 Placing equipment in service.....................…............
Page
3-1 3-1 3-1 3-1 3-1
IV Contents
Figures
Figure
1-1 1-2
Front Panel.......................................….....…...
Rear Panel........................................…...........
Page
1-6 1-6
Tables
Table
1-1
Technical Specifications...................…...........
Page 1-2
Safety consideration V
SAFETY RECOMMENDATIONS AND INSTRUCTIONS
This product has been designed, produced and tested in Italy, and it left the factory in conditions fully complying with the current safety standards. To maintain it in safe conditions and ensure correct use, these general instructions must be fully understood and applied before the product is used.
When the device must be connected permanently, first provide effective grounding;
If the device must be connected to other equipment or accessories, make sure they are all safely
grounded;
In case of devices permanently connected to the power supply, and lacking any fuses or other devices of mains protection, the power line must be equipped with adequate protection commensurate to the consumption of all the devices connected to it;
In case of connection of the device to the power mains, make sure before connection that the voltage selected on the voltage switch and the fuses are adequate for the voltage of the actual mains;
Devices in Safety Class I, equipped with connection to the power mains by means of cord and plug, can only be plugged into a socket equipped with a ground wire;
Any interruption or loosening of the ground wire or of a connecting power cable, inside or outside the device, will cause a potential risk for the safety of the personnel;
Ground connections must not be interrupted intentionally;
To prevent the possible danger of electrocution, do not remove any covers, panels or guards
installed on the device, and refer only to NARDA Service Centers if maintenance should be necessary;
To maintain adequate protection from fire hazards, replace fuses only with others of the same type and rating;
Follow the safety regulations and any additional instructions in this manual to prevent accidents and damages.
VI EC Conformity
EC Conformity Certificate
(in accordance with the directives: EMC 89/336/EEC and low voltage 73/23/EEC)
This is to certify that the product: PMM 6000N Wideband RF Power Amplifier Produced by: NARDA S.r.l.
Safety Test Solution Via Benessea 29/B 17035 Cisano sul Neva (SV) - ITALY
complies with the following European Standards: Safety: CEI EN 61010-1 (2001) EMC: EN 61326-1 (2007)
This product complies with the requirements of the Low Voltage Directive 2006/95/CE and the EMC Directive 2004/108/CE.
The PMM 6000N Wideband RF Power Amplifier MUST BE USED IN THE CONFINES OF A SHIELDED ROOM, in order to comply with the requirements of the referenced EMC Directive.
NARDA S.r.l.
Loading...
+ 12 hidden pages