Napoleon Grills WF9ST, WF 18, WF 9, WF 6 User Manual

SERIAL / SÉRIE#______________________
DECORATIVE INDOOR WATERF ALLS
THAT PURIFYAND HUMIDIFY THE AIR
WF 6/9/18
WF9ST
MANUFACTURED BY / MANUFACTURE PAR:NAPOLEON APPLIANCE CORP.,
214 BAYVIEW DR., BARRIE, ONTARIO, CANADA L4N 4Y8 PHONE: (705)726-4278
RETAIN THIS MANUALFOR FUTURE REFERENCE
GARDER CE LIVRE POUR RÉFÉRENCES FUTURES
N415-0128 / NOV16/06
NAPOLEON waterfalls are manufactured under the strict Standard of the world recognized
ISO 9001-2000 Quality Assurance Certificate.
NAPOLEON products are designed with superior components and materials, and are assembled
by trained craftsmen who take great pride in their work. Every component is thoroughly in-
spected by a qualified technician before packaging and shipping to ensure that you, the
customer, receive the quality product you expect from NAPOLEON.
NAPOLEON WATERFALL PRESIDENT'S WARRANTY
NAPOLEON warrants the materials and workmanship in your new NAPOLEON Waterfall against
defects for a period of one year. This excludes filters, light bulbs, and UV light bulbs.
NAPOLEON shall not be liable for any transportation charges, labour costs, installation or removal
costs, water damage or export duties.
CONDITIONSAND LIMITATIONS
"NAPOLEON warrants its products against manufacturing defects to the original purchaser only (ie., the individual or legal entity (registered customer) whose name appears on the warranty registration card filed with NAPOLEON), provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following conditions and limitations:"
This factory warranty is non-transferable and may not be extended what-so-ever by any of our representatives.
The waterfall must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the product and all local and national building codes.
This limited warranty does not cover damages caused by misuse, lack of maintenance, hostile environments, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this warranty.
This limited warranty further does not cover any scratches, dents, rust, painted finishes, abrasive and chemical cleaners, nor chipping on porcelain enamel parts, nor any components used in the installation of the waterfall.
Should deterioration of parts occur to the degree of non-performance within the duration of the warranted coverage, a replacement part will be provided.
In the first year only, this warranty extends to the replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions.
NAPOLEON will not be responsible for the installation, labour or any other costs or expenses related to the re-installation of a warranted part, and such expenses are not covered by this warranty.
Notwithstanding any provision contained in this President's Warranty NAPOLEON's responsiblity under this warranty is defined as above and it shall not in any event extend to any incidental, consequential, or indirect damages.
This warranty defines the obligation and liability of NAPOLEON with respect to the NAPOLEON waterfall and any other warranties expressed or implied with respect to this product, its components or accessories are excluded.
NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product.
Any damages to the waterfall due to weather damage, hail, rough handling, damaging chemicals or cleaners will not be the responsibility of NAPOLEON.
The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from NAPOLEON. The warranty registration card must be returned within fourteen days to register the warranty or you can register on-line at www.napoleongrills.com.
NAPOLEON reserves the right to have its representative inspect any product or part prior to honouring any warranty claim.
NAPOLEON shall not be liable for any transportation charges, labour costs, installation or removal cost, water damage or export duties.
2
indoor air quality
Yournew NAPOLEON waterfallwill dramatically improvethe indoor airquality in your home. The waterfall isa natural humidifier
which helps alleviate dryskin and allergies. This is extremelybeneficial in dryclimates and alsocold climates whereforced air furnaces dry theair. The waterfall alsocleans the airby attracting contaminants. Moving water attractsairborne particles, suchas dust, pet dander, pollen andother pollutants. The waterfalldraws these particlesinto the water,whichis thenfiltered through a 5 micron filter beforebeing recirculated. The result iscleaner,fresher,humidifiedair. Waterfalls also generatenegative ions. These odourless tasteless invisible moleculesare created innature as airmolecules break apartdue to sunlight,radiation, and movingair and water. Researchers nowbelieve that negativeions aid inalleviating depression, reducingstress and boostingenergy.
installation Tools and materials required
Before you beginhooking upthe fountain ensurethat youhave access to the followingmaterials andtools. Tools:
-utility knife
- adjustable w rench
- 3/8” nut driver
-pliers
- flat screwdriver
Materials:
- saddle valveand 1/4”tubing (ice makerplumbing kit)(required if unit is beingconnected to house watersupply)
- teflon tape
- possible additional 1/2” i.d. tubing and 3/4” i.d. tubing depending on location of unit.
- liquid TSP (TrisodiumPhosphate) or TSP Substitutecleaner
appropriate location
There are severalthings to considerwhen choosing theappropriate location toinstall your waterfall. The waterfall isdesigned to beinstalled into a2” x 4”interior wall. The waterfallshould not beinstalled in a load bearingwall,
unless it can be framed in withproper supportsand headers as required by your local building codes. Check with your local building authority forspecifications. Installing thewaterfall in anexterior wall isnot recommended, asit cannot beproperly insulated. If there areno suitable alternativelocations, then thewaterfall can beinstalled in a2” x 6”wall using rigidfoam insulation between the exterior of the houseand theback ofthe fountain. The waterfallcannot beinstalled in a 2” x 4” exteriorwall.
The see-thru waterfall only has water running down one side of the glass, so thoughtshould begiven asto whichdirection the
unit is mounted. The side with themanifold isthe side with the water flow. The see-thru waterfall is not designed to beair tightlike a window and cannot be placed on an exterior wall. If being placed between rooms where privacy may bea concern,a cloudedor patternedglass can beused. Some noise will also travelbetween the tworooms that sharethe waterfall.
The lights, pump andoptional UV-light require power. Make sureyou choose alocation that hasthe available power within reachof
the supplied electricalcords. The receptaclemust be GFI(ground fault interrupt)protected. Electrical work mustbe done bya qualifiedelectrician. Checkwith your localbuilding authority forspecificationsfor your area. Do not runextensioncords behind walls.
An area to locate the pump module is also required. It should be located as close to the fountain as possible and in a location
that is easilyaccessible for servicingand maintaining themodule. For every 1foot thatthe pump moduleis located awayfrom the fountain unit, 1 inch of drop is required from the fountain basin drain outlet to thepump moduledrain inlet.
The waterfall isdesigned to beconnected to a watersource, to automatically refill thebasin as waterevaporates, and to a drain,
in case of accidental overflow. The unitcan beoperated without the water source connection, but is not recommended. The water will evaporate naturallyand will requireadditional water to ensure properflow and pumpoperation. Damage to thepump incurred by running dry is not covered by warranty. The waterfall must be hooked-up to a drain whichwill allowthe tankto bepurged for routine cleaning, andwill prevent theunit from overflowingif the floatvalve malfunctions.
Waterdamage to surrounding objectsin your home isnot coveredin yourNAPOLEON warranty. The waterfall is designed to not
splash, however ifit is notproperly installed ormaintained,some splashing mayoccur. Protect delicatenearby surfaces thatcould be damaged by splashing. Donot trim with materials that can be damaged by moisture such as particle board or MDF. It isbest to install the unitin stone, marble,glass, tile etc.
Although your NAPOLEONWaterfallwill bebeneficial to theair quality of your home,excess moisture can lead tothe formation of
mold and mildew. It is recommended that allhomes have some form ofhumidity controland air exchange system toprevent such an occurence.
3
water
Wateris perhaps the mostcritical component in the waterfall. Dirty or contaminatedwater will quicklycause operational problems
with your waterfall. House water must be softened andfiltered if the unit is to beconnected tothe watersupply. RO (Reverse Osmosis) water willgive thebest results, andrequire the least amount ofmaintenance. If the unit is notbeing connectedto the house supply,distilled bottled wateris recommended. The provided filterand optionalUV-lightcannotprevent hard waterdeposits from forming onthe surfaces of your waterfall. Hard water will alsocause plugged passagesand manifoldports, reducing theflow effect on the waterfall surface. The life-spanof thepump will also be adversely affected dueto theuse of hard water. Use ofRO or distilled water isby far thebest way ofensuring years ofcarefree enjoyment fromyour waterfall.
The provided sedimentfilter will helpprevent clogging ofthe manifoldports that dispersethe water downthe face ofthe waterfall.
The water that flows downthe facewill attract dust, debris particlesand mouldspores that are floating in the airin yourhome. This will help tonaturally filter theair you breatheand keepyour home cleaner. However thefilter will become contaminated and the water flow willbe reduced overtime. We recommend thatthe filter bereplaced whenever the waterfall iscleaned, every 3-4months or sooner as deemed necessaryby poorwater flow. The filters can bepurchased throughyour authorized NAPOLEON dealer.
The optional ultraviolet-lightwill help destroyany green algae,bacteria, mould ormildew found inthe water. Flowing water isfairly
resistant to thiskind ofgrowth, but in time the water willbecome contaminatedand the systemwill haveto be flushed and thor­oughly cleaned. Notonly unsightly but mould and bacteria growth will plug the manifold ports, reducing the flow of water and can damage the waterpump over time. The optional UV-lightwill helpto keep your waterfall relativelymaintenance free bykeeping the water cleaner for a longerperiod oftime. The UV-bulb must be replaced every year to ensure properoperation. The UV-bulbs are availablefrom yourauthorizedNAPOLEON dealer.
The waterfall isdesigned to beconnected directly to a watersource. Waterfallsare natural humidifiersfor the environment. The
amount of waterthe waterfallconsumes daily is dependant uponhow dry the air is,and howlarge the waterfall surface is. There is a float valvethat will openas the waterlevel drops, allowing water toenter the system. This willensure that thewater level iskept at the height required for proper operationof thewater pump. The pump shouldnever beallowed to run dry and damage resulting from that willnot becovered by warranty. If there is nota suitablewater source tobe had nearby,thewaterfall canbe installed asa stand-alonesystem, but thewater level willhave to bemonitored frequentlyand supplemented asneeded.
WATER PUMPS
The water pumpsupplied with yourwaterfall has beenselected for itshigh flow volume,efficiency,quiet operationand reliability.
The pump is suitable for pushing water to a height of 12 feet, however the flow is reduced greatly atthat height. This must be kept in mind when finding a location for the pumpand water basin, so the pump module must be located on the same floor as the fountain. The minimum spacerequired for the pump module for the waterfall is18” x 18” x 15” high. The systemhas a flow control valve after the filter that canbe adjusted toprovide the desiredflow rateon the waterfallsurface.
The pump must be kept submersed in water at alltimes whilein operation. The water acts as a cooling agent for the pump,
preventing the pumpfrom overheating. Low water levels, frequentlyturning the pump on and off andimpurities in the water from poor waterfall maintenancewill shorten thelife of thepump. If maintained properly, the pumpwill provide yearsof reliable service.
If you hear excessive noise coming from your pump, check first to see that you have enough water in the basin to keep the pump
fully submerged below 1-2” of water. The pump should not be vibrating against thetub, butif itis, itcan beisolated byplacing a small piece of sponge between the pump and the basin. Be sure to not block or restrictin anyway thepump’s water inlet.
ELECTRICAL REQUIREMENTS
The waterfall willrequire 2 separate110voltelectrical receptacles, one for thelightsand onefor the waterpump. GFIrecepta-
cles must be used, becauseof theuse of water and possibility of contact.
It is notrequired that the receptacles be wired on theirown circuit, asthe pump,lights and optionalUV-lightdraw very little
current. If thereis already a heavy loadelsewhere on thatcircuit or youhave trouble withbreakers tripping,a separate circuit will need to beinstalled. Any circuitwiring or GFI installation mustbe doneby a qualified electrician. If you would liketo be able to turn the fountain onand off,the receptacles should be wired to awall switch. Twowall switchedreceptacles are recommended, one for the pump and UV-light (optional) and one for the lights. This willallow youto turnthe lightson andoff independently of the fountain.
4
INSTALLATION
The framing dimensionsare included inthe framing specificationsdrawing. The unit is designedto be installedafterdrywalling.
For added protectionwater resistant drywall (green board)or cement board are recommendedin thevicinity of the fountain. The fountainis designed to be attachedto the studsover thedrywall along bothvertical sides of the fountainusing drywall screws. This will leave abasically flush surfaceto trim over. Leaktest thewaterfall before fullyenclosing. All trim usedon the fountainshould be made of real wood (notMDF), orany othermaterial that is not damaged by moisture, with severalcoats of a water proof coating (paint or urethane) depending on the desired look. The bottom piece of trim can only be nailedat theends, becauseit is mounted in front ofthe stainless basin. It shouldbe siliconed tothe stainless basinfor additional support.
After installing thefountain, connect the piping as shownin thepiping diagrams. The tubing to connect the unit overflow to the
house drain is not supplied. If theunit isbeing connectedto thewater supply, use an ice maker plumbing kit (not supplied) to connect the water supply to the floatvalve. When theunit isoperational, adjustthe floatvalve so that it turns the water off whenthe top of the pump is submerged below 1-2”of water. Ensure thatthe wing nut on the side of the float valve is properly tightened. Connect the lightwire to the terminals onthe transformer.
WATERFALL SURFACE MATERIALS
The waterfall models WF6, WF9, and WF18 are supplied witha stainlesssteel panel for the water to flow over. The surface of
the stainless steel mustbe cleaned to remove anygrease or oilymaterials left behindfrom the manufacturingprocess. The protec­tive coating willalso leave aresidue behind. Anyresidue left on thesurface, or oily residue fromyour hands, willrepel the water and prevent asheet of water from formingover thepanel. This will give youthin streams of water with large dryspots in between. Cleaning the panelwith liquid TSP(orTSP Substitute) willremove any residueor filmthat is impedingthe progress of the water. Clean the panelthoroughly two orthree times before the firstuse.
The See-Thru waterfallmodel isnot supplied with any surfacepanel. The glass panelcan be ordered from anyglass andwindow
dealer in yourlocal area. There isno specific typeof recommended glass, but theglass should be1/4” thick. Clear glassdisplays the water flowpattern the best, but ifprivacy between the adjoining roomsis desiredsome type of smoked oropaqued glass will work as well.
Before starting the waterfall, the entirepanel surface shouldbe wet down,either byspray bottle, orwet cloth. This willhelp the
water to spreadevenly across thepanel. The waveeffect of waterflowing downthe panel, willbe attained afterthepanel is covered in water. The wave pattern canbe adjustedby increasing or restricting the flow of water withthe valveat the side of the filter. Adjust the valve toachieve the effectthat is mostpleasing to your eye. It isimportantto remember thattoo littlewater flow cancause dry spotsto reappearon the surfaceof thewaterfall. Youcan increase theflow ofwater slightly untilthey disappear. Lightly rubbing a wet cloth orScotchbrite pad(careful not toscratch thestainlesssteel surface),across the panel may beenough to remove any dry spots.
TO FOUNTAIN
TO FOUNTAIN
FROMBASIN
TO DRAIN TO DRAIN
VALVE
FULL OPEN
GROOVED LUXIDIO PANEL: An optional grooved LUXIDIO panel which enhances the ripple effect can be purchased at your
authorized NAPOLEON dealer. This panel must be cleaned with liquidTSP (or TSPSubstitute) before being placed in the unit, to prevent dust and debris from the manufacturing process from entering thewater. Use caution when cleaning the grooves on the panelas the machinededges can be very sharp. The stainless steelpanel must beremoved before installingtheLUXIDIO panel. Turnoffthe water before switching thepanels. Toremovethe stainless steelpanel, slide itupwards slightly,then swing thebottom of the paneltowards you, clearing the panelretaining brackets. Slide thepanel downwards and out ofthe fountain. Install the LUXIDIOpanel in the reverse order. The LUXIDIO panelwill require more water toachieve the samewave effect asthe stainless panel,as the grooves will filland retain water. Again any dryspotscan beremoved by rubbinghorizontally with aScotchbrite pad.
FROMBASIN
VALVE
PARTIALOPEN
5
BACKBOARD
WF6
BACKBOARD
WF9 WF18
BACKBOARD
MORTAR
TILES
23.625”
CUSTOM SURFACE PANEL:Panels can also be made using materials such asmirror,
glass, slate, marbleor ceramic tilefor display inyour waterfall. If tiling,use waterproof cement board as a backer, available atany buildingcentre. Cut thecement boardto the size of your existing stainless steelpanel. Ensure thatthe tiles canbe used in a wetenvironment. Porce­lain tiles arerecommended. Tile the surface,using thinsetmortar, as youwould a ceramictile floor or bathroom wall. It is not necessary to leave a gap or grout line in your tile. Ensure that the bottom edge of thetiles are flush with the bottom edge of the cement board. Youcan choose any colour or pattern thatyou like,to match the room or surroundings. The waterwill flowover the tiles, just as it doeson thestainless steel panel,but besure tokeep the edges of the tiles fairly flush toeach otherto prevent the water from splashing off. Surfaces less than 3/8” thick, suchas glass or mirror,can beinstalledin front of the stainlesspanel. The stainlesspanelmust be removed for allpanels thicker than 3/8” upto a maximum of 3/4”. Donot useglue to attach thetiles to the back panel, as some types of glue orepoxy will leach out into the water,causing the filter and manifold to plug.
35.250”
MORTAR
TILES
35.50”
35.250”
70.50”
MORTAR
TILES
35.50”
CLEANING AND MAINTENANCE
The waterfall shouldbe drained and cleaned every3-4 months, possibly more dependingon thequality of thewater. The water-
fall surface can be cleanedusing awarm soap and water mixture. Do not use harsh abrasive cleaners onthe surfaceof the stainlesssteel panel or it willpermanently scratch the surface. Any wiping motion shouldbe done in the directionof thegrain. If small scratches do occur, theycan beblended outby gentle rubbing in the direction of the grain with a Scotchbrite pad.
The water shouldbe completely flushedand drained from the system- switch thevalve to
the purge setting, and run the pumpto pump the water out. Refill the tank, run the water through the fountain for 3 minutes and purge again. If calcium or hard water deposits are forming on thepanel or anywhereelse in the system, cycleCLR solution through the system until the depositsareremoved thenpurge the systema few timeswith water.
If there are spotson thepanel thatdry out, check that there are noblocked portsin the
manifold tube. Remove the three nuts that secure the tube cover,and removethe cover. Re­move the tube by flexing itout inthe centre. This will allow the endsto pullout. Poke the holes out with an opened paper clip, and then flush the tube with water. Clean the angled surface that the manifold sprays ontowith liquid TSP (orTSPsubstitute). It iscritical that thissurface is extremely clean. Installthe tubeback into the unit, withthe portsaiming straight downand refillwith water. Installthe tubecover and testthe unit.
MANIFOLDTUBE
TUBE COVER
FROMBASIN
TO FOUNTAIN
TO DRAIN
VALVE
PURGEPOSITION
The sediment filter should bereplaced every3-4 months. To replace, unplug the pump. Lay a towel under the filter housing,as
water will drain out of the housing when opening. Unscrew the housing, and remove the filter. Replace witha newfilter (part #N252-0001) available throughyour authorized NAPOLEONdealer. Push thenew sediment filterfirmly onto the collar inthe bottom of the housing. Screwthe housing back onto the unit. This mustbe screwed on very tightly, or it will leak.
6
TROUBLESHOOTING
Problem Possible Causes Solution
Waternot flowing. Pump not plugged in.
Insufficientwaterlevel. Add waterto recommended level. Pump must be submerged by1-2” atall
Waterflowcontrolvalve turnedoff.
Sedimentfilter plugged. Pumpis “vapour-locked”. The pump mayhave an air bubble init, preventing itfrom pushingwater
Pump burned out. Replacepump.
Dryspots on waterfall surface.
Lights not working. Lights not plugged in. Pluglights into nearest electricalreceptacle.
(optional)
Improperstart-up procedure.
Insufficientflow. Increaseflow by openingwater flow valve. Surfacenot cleaned
properly. Pluggedports in manifold. Turnoff water andremove manifold tube. Inspect and clean. See cleaning
Burrs on edges of LUXIDIO panel.
Bulb(s)are broken. Replace lightbulb(s). UV-lightnot plugged in. PlugUV-lightintonearest electrical receptacle.UV-lightnotworking.
Bulb no longer good. ReplaceUV-lightbulb.
Plugpump into nearestGFI protected receptacle.
times. Turnvalveto on position.
Replacefilter.
through. Unplug the pump, andplug it back in severaltimes, ormomentarily turnthe valve tothe purge setting.
Ensuresurface of waterfallis wet beforestartingby spraying withwater or washingwith wet cloth.
Cleanwith liquid TSP (orTSPSubstitute) to removeoilyresidue.
instructions. Turnoff the water. Remove theburr onthe edge of the groove with a utility
knife.
Waterleaking on floor.
Drainis gurgling. Insufficientdrop from
Waterdripping from lip oftop retainer.
Waterfallappearsto berusting.
Leakingconnection. Check all connectionsand ensure theyare tight. If leaking, re-tighten. Waterleveltoo high. Check that the basin drainis hooked-upproperly andnot blocked,
Weldleaking in waterfall housing.
Waterleaking out sidesof waterfall.
fountainto basin. P-trapcreated in drainline. Ensurethat there isa consistent slopefrom the fountainoutlet to basininlet
Certaindrain configurations mayhave a tendencyto gurgle.
Decorativepanel is not touchingfront lip ofretainer.
High concentration of iron in water.
preventing water fromescaping. Ensure thatthere is adequatedrop from the fountain to thebasin. Also checkthat the floatvalve is workingproperly andnot overfilling thebasin.
Inspectwaterfall thoughly andascertainexactly where theleak is coming from. Drain all water, and drythoroughly. Apply a beadof clearsilicone to the inside surfaceof the weld. Let stand24 hours beforere-filling with water.
Wipe the sidesof the waterfallframe with an oiled(WD40) ragto repel water.
Ensure there is at least1” perfoot drop from the fountain outlet to the basin inlet.
without a dipthat wouldtrap water. Reduce the flowthrough the flow control valve,or loosen thewhite fittingin
the left handdrain (loosen a couple of turns ata time,and then test).
Removethe panel andflexout the paneltension springs. Ensure positive tensionon panel. Replace the decorativepanel.
Thewaterfall and componentsaremade entirely ofstainlesssteel and cannot rust. Use CLR remover toclean the iron deposits offthe affected areasand refill thewaterfallwith the recommendeddistilled water.
7
ORDERING REPLACEMENT PARTS
Before contacting the customerservice department, checkthe NAC website for moreextensive cleaning,maintenance, trouble-
shooting and partreplacement instructions atwww.napoleongrills.com. Contact the factorydirectly for replacementparts and warranty claims. The customer servicedepartment is availablebetween 9 AM and5 PM (Easternstandard time) at1-866-820-8686 or fax at 1-705-727-4282. Inorder to process a claim, we must be provided with the following information:
1. Model and serial number of the unit.
2. Part numberand description.
3.Aconcise description ofthe problem('broken' isnot sufficient).
4. Proof of purchase (photocopy ofthe invoice).
In some casesthe customer servicerepresentativemay requestto have thepartsreturned to thefactory forinspection, before
providing replacement parts. The parts must beshipped prepaid tothe attention of the customerservice department withthe above information.
Before contacting customerservice, kindly notethat the followingitems are notcovered by the warranty:
-costsfor transportation, brokerageor export duties
-labour costs forremovaland reinstallation
-costsfor service callsto diagnose problems
-discolorationof stainless steelparts
-partfailure dueto lack ofcleaning andmaintenance, or useof impropercleaners.
NOTES
Therestofthis page has been intentionally left blank.
8
FRAMING SPECIFICATIONS
2x6 HEADER PANEL RECOMMENDED
CHECK WITH LOCAL CODES
HEIGHT
Ø1.50”
24”
RECOMMENDED*
CHECK WITH YOUR LOCAL BUILDING AUTHORITY FOR COMPLETE FRAMING GUIDELINES. THE CHART
BELOW WILL GIVE YOU THE OPENING SIZE REQUIRED FOR EACH MODEL. EACH WATERFALL IS IN-
TENDED TO BE MOUNTED ON TOP OF THE DRYWALL (NOT SHOWN). THE DRYWALL BELOW THE UNIT
SHOULD CONTINUE UP TO THE BOTTOM OF THE WATERFALL BASIN.
WF6
WF9 / WF9ST
4.00” CENTERS
WIDTH
49.00”
49.00”
CONTINUE DRYWALL
UP TO THIS EDGE
WIDTHHEIGHTMODEL
26.750”
38.625”
WF18
*Additional height may be required to ensure adequate drop to the pump module.
The minimum space required for the pump module for the waterfall is 18” x 18” x 15” high.
84.25”
38.625”
9
PIPING DIAGRAM WITHOUT UV LIGHT
6X N570-0043 (8-32 X 3/4")
1
TO
ELECTRICAL
OUTLET
2
FROMTHREE
WAY VALVE TO
WATERFALL
A
FROM BASIN TO
WATERFALLDRAIN
INSTALLTHE SUPPLIED
HOSE CLAMPS ONEITHER
SIDE OF THE BASIN
CUT THE SHORT PIECE OF BLACK
TUBING TO 14”
OVERFLOW
PROTECTION
FROM WATERFALL
DRAIN TO BASIN
B
B
A
SEDIMENT
FILTER
FROM THREE WAY
VALVE TO WATERFALL
FROM WATER
SOURCE TO
FLOATVALVE
SADDLEVALVE
(NOTINCLUDED)
FLOW CONTROL
VALVE / PURGE
VALVE
TO DRAIN
PURGE LINE
Removecomponentsfrom basin and assembleasshown. The fittings requiredarealreadyattachedto the filter andbasin. Measure
andcut the linestothe length necessary,push onto the barbedfittings and securewiththe supplied hoseclamps. Leaktest the waterfall beforefullyenclosing.
10
PIPING DIAGRAM WITH UV-LIGHT
9X N570-0043 (8-32 X 3/4")
TO
ELECTRICAL
OUTLET
1
3
2
4
FROMTHREE WAY
VALVE TO
WATERFALL
WATERFALLDRAIN
INST ALLTHE SUPPLIED
HOSECLAMPSON EITHER
SIDEOFTHE BASIN
OVERFLOW
PROTECTION
TODRAIN
FROMWATERF ALL
A
FROMBASINTO
B
PURGELINE
DRAINTOBASIN
B
UV
LIGHT
A
SEDIMENT
FILTER
FROMTHREE WAY
VALVETO WATERFALL
FROMWA TER
SOURCETO
FLOAT VALVE
SADDLE VALVE
FLOWCONTROL
VALVE/ PURGE
VALVE
Remove components from basin and assemble as shown. The fittings required are already attached to the filter and basin.
When using the optional UV light, the barbed elbow fitting on the “IN” sideof thefilter willneed tobe removedand threadedinto the elbow at the bottom of the UV light. Thenconnect the UV light directly to the sediment filter. Use teflon tape toseal these connec­tions. Ensure that the supplied ground wire isconnected from the grounding terminal on the UV lightto either grounded copper plumbing, or the groundin yourelectrical system. Use thesupplied short piece of black tubing to run fromthe pump to the UV light. Measure and cut the linesto thelength necessary,push ontothe barbedfittings and secure with the supplied hose clamps. Leak testthe waterfall beforefully enclosing.
11
b
WATERFALL SURFACE INSTALLATION
The stainless steel panelprovided with WF6,WF9, and WF18 is installedsimply by slidingthe top ofthe panel underthe retaining
bracket at the top ofthe waterfall,and pushingit highenough to slip over the bottom support brackets. The weldedbrackets that protrudeat an anglefrom the waterfallhousing, merely providepressure to thepanelto prevent itfrom bowing. The optional acrylic panelcan be placed in frontof the stainlesssteelpanel in thesame manner. If building yourown ceramic tileor slatebackground, you mustremove the stainlesssteel panel, because ofthe thickness ofthe tile and cementboard backing.
The glass panelfor WF9ST isinstalledfrom the manifold side bysliding the topof the glass into thegap between theretaining
bracket and the rear panel support, and pushing it high enoughto slipover thelip onthe bottomsupport brackets. The glass should fit tight at the top and not rattle. Ifso itcan beremoved andthe frontretaining bracketcan bepushed in,closing up the gap so the glassfitstight.
PARTS LIST
ITE M # WF6 PART# WF9 PART# WF9ST P ART# WF18 PART# PARTS DESCR IP TI ON
1 n010-0446 n010-0447 n010-0490 n010-0448 main housing x 2 n010-0449 n010-0450 n010-0450 n010-0451 w ater supply line assembly x 3 n432-0014 n432-0015 n432-0015 n432-0015 manifold x 4 n105-0008 n105-0008 n105-0008 n105-0008 rubber grom met x 5 n080-0169 n080-0170 n080-0170 n080-0170 water pinch bracket x 6 n450-0009 n450-0009 n450-0009 n450-0009 10-24 nut x 7 n402-0006 n402-0006 n402-0006 n402-0006 lighting track WF6 - 20" long WF9/18 - 32" long x 8 n402-0004 n402-0004 n402-0004 n402-0004 lighting track end cap x
9 n402-0005 n402-0005 n402-0005 n402-0005 lighting track pow er connection x 10 n402-0007 n402-0007 n402-0007 n402-0007 light socket x 11 n402-0003 n402-0003 n402-0003 n402-0003 light bulb x 12 n200-0071 n200-0072 n200-0072 n200-0072 light cover x
n707-0002 n707-0002 n707-0002 n707-0002 12volt transformer x 13 n255-0033 n255-0033 n255-0033 n255-0033 1/2" female pipe to 1/2" barb adapte r fitting x 14 n160-0012 n160-0012 n160-0012 n160-0012 5/8" hose clamp x 15 n160-0013 n160-0013 n160-0013 n160-0013 1" hose clamp x 16 n255-0034 n255-0034 n255-0034 n255-0034 3/4" bulkhead fitting x 17 n255-0037 n255-0037 n255-0037 n255-0037 3/4" malepipeto 3/4" barb elbow fitting x 18 n475-0149 n475-0150 - n475-0151 waterfall panel - stainless steel x
n475-0152 n475-0153 - n475-0154 waterfallpanel- black grooved LUXIDIO ac 19 n335-0037 n335-0037 n335-0037 n335-0037 water basin lid x 20 n185-0002c n185-0002c n185-0002c n185-0002c w ater basin x 21 n255-0035 n255-0035 n255-0035 n255-0035 1/4" female pipe to 1/2" barb adapte r fitting x 22 n517-0001 n517-0001 n517-0001 n517-0001 water pump x 23 n725-0023 n725-0023 n725-0023 n725-0023 float valve x 24 n010-0443 n010-0443 n010-0443 n010-0443 w ater basin housing x 25 n725-0022 n725-0022 n725-0022 n725-0022 3-way valve x 26 n255-0041 n255-0041 n255-0041 n255-0041 3/4" malepipeto 1/2" barb adapter fitting x 27 n350-0052 n350-0052 n350-0052 n350-0052 sedim ent filter housing x 28 n252-0001 n252-0001 n252-0001 n252-0001 replacement sedimentfilter (5 micron) ac 29 n080-0177 n080-0177 n080-0177 n080-0177 filter mounting bracket x 30 n570-0043 n570-0043 n570-0043 n570-0043 8-32 x 3/4" stainless steel screw x 31 n402-0002 n402-0002 n402-0002 n402-0002 ultra violetligh t ac 32 n402-0008 n402-0008 n402-0008 n402-0008 ultra violetreplacement bulb ac 33 n080-0171 n080-0171 n080-0171 n080-0171 ultra violetlight moun ting bracket ac 34 n255-0042 n255-0042 n255-0042 n255-0042 fitting, plastic 1/2" malepipe- 1/2" barb elbow x
12
35 n255-0039 n255-0039 n255-0039 n255-0039 fitting, plastic 1/2" femal epipe- 1/2" female pipe el 36 n255-0040 n255-0040 n255-0040 n255-0040 3/4" malepipe x 1/2" femalepipebushing x
x- standard x -compris ac - accessory ac- accessoires
ac
PARTS DIAGRAM
13
Loading...