WARNING: For Outdoor Use Only.
FOR YOUR SAFETY
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. if odor continues ,immediately
FOR YOUR SAFETY
Do not store or use gasoline or
other flammable vapors or liquids
in the vicinity of this or any other
appliance.
WARNING: Improper installation,
adjustment, alteration, services or maintenance can cause injury, death or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
CAUTION: Retain the instructions
for future use.
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a camper, tent, car or home.
CERTIFIED
S
E
D
C
E
R
T
DANGER
I
G
N
D
E
I
F
I
Manual,Instructions & Parts List
TOOLS AND PARTS NEEDED FOR ASSEMBLYTOOLS AND PARTS NEEDED FOR ASSEMBLY
WARNING: For outdoor use only.
Cylinders to be used must be constructed and marked in accordance with US DOT specifications.
Storage indoors is permissible only if the cylinder is removed.
CAUTION:
The minimum inlet gas supply pressure for the purpose of input adjustment is 8 inches water column. The maximum inlet gas supply pressure is 13 inches water column. The gas manifold supply pressure must be regulated at 11 inches water column utilising an approved regulator.
Note: 1 Pound LPG Tank is not supplied
TOOLS NEEDED:
Adjustable Opening Wrench, 8 Long Philips Head Screwdriver Leak Detection Solution ( Instructions how to make solution are included in Step 5 )
Specification
Certification CSA
RatedHeatInput 10000BTU/HR
Fuel Propane-LP
Gas Supply 16.4ozOR 20 Lb.LP-Gas cylinder
Manifold Pressure 11.0 inches W.C
Injector Size(diameter) 0.91mm
Safety Features Flame failure device,Tilt switch&Oxygen Depletion Safety(ODS)pilot
Gas Supply Pressure Max 150PSI,Min5PSI
2
PARTS LISTPARTS LIST
11
22
33
44
55
66
77
88
7 8-32UNC
99
Screw L=8
88
77
7 8-32UNC
1010
Screw L=6
1111
3 HEX NUT
1212
6 WASHER
1 HOSE ASSY
1313
(not supplied)
1414
1 STRETCH LINE (not supplied)
The fasteners used comply with ANSI/BL.1
Save these instructions! Retain in a safe place for future reference.
3
NOTE: PLEASE READ THE FOLLOWING SAFETY RULES
PRECAUTIONSPRECAUTIONS
WARNING
This appliance must only be used outdoors. Using this product in an enclosed area may cause injury, death or property damage.
Read the instructions before use. This appliance must be installed in accordance with such regulations as are in force.
Do not use the heater in an explosive atmosphere. Keep the heater away from areas where gasoline or other flammable liquids or vapors are stored.
Prior to use, check for damaged parts such as hoses, regulators, pilot or burner.
The installation of fixed appliances shall only be carried out by competent persons and be in accordance with the relevant Codes of Practice. Warning: This appliance requires a gas hose and regulator, check with your gas supplier and or product supplier. Regularly check the gas hose and if necessary, replace the gas hose.
DISCONNECT LPG bottle before moving the heater.
Do not attempt to alter unit in any manner. EXAMPLE: using the heater without the top canopy reflector or radiant screen. Do not shorten the burner post assembly.
The appliance shall not be used in basements or below ground level. It must always be placed on a solid and level surface.
Always assure there is ample fresh air ventilation. For outdoor use ONLY.
Never replace or substitute the regulator with any regulator other than the factory suggested replacement.
¥At least once a year, the unit should be inspected for the presence of spiders, spider webs or other insects. Check the heater immediately if any of the following exist:
1. The smell of gas in conjunction with extreme yellow colored tips of the burner flames.
2. The heater does not reach temperature.
3. The burner makes popping noise during use (a slight popping noise is normal when the burner is extinguished after using).
The propane hose with regulator assembly shall be located out of pathways where people may trip over it or in areas where the hose will not be subject to accidental damage.
Children and adults should be aware of the hazards of high surface temperature and shall stay away to avoid clothing burn or ignition.
Young children should be carefully supervised when they are in the area of the heater.
Clothing or other flammable material should not be hung from the heater, or placed on or near the heater.
Any guard or other protective device removed for servicing the heater must be replaced prior to operating the heater.
Installation and repair should be done by a qualified service person. The heater should be inspected before use and cleaning may be required at least once a year, or as necessary. It is imperative that control compartment, burner and circulating air passageways of the heater be kept clean.
Do not clean the heater with cleaners that are combustible or corrosive.
Do not paint radiant screen, control panel or top canopy reflector.
All leak tests should be done with a soapy solution. NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS.
The LP gas cylinder should be turned off when the heater is not in use.
Keep the appliance area clear of combustible materials such as gasoline and other flammable vapors and liquids.
Do not obstruct the flow of combustion and ventilation air.
Keep the ventilation opening of the cylinder enclosure free and clear of debris.
4
NOTE: PLEASE READ THE FOLLOWING SAFETY RULES
WARNING:
The hose assembly should be properly located out of pathways where people may trip over it. The hose must be protected from contract with hot or sharp surfaces both during use and while in storage.
The hose assembly should be visually inspected prior to each use of the heater. The hose assembly should be visually inspected during use.
At least once a year, the entire hose assembly should be inspected.
If excessive abrasion or wear is evident, or the hose is cut, it must be replaced prior to operating the heater. The replacement hose assembly may be obtained
from the manufacturer.
DO NOT use any pressure regulator or hose assembly
other than those supplied with the appliance. Replacement pressure regulator and hose assembly must be those specified. Replacement parts may be obtained from the manufacturer or your local sales representative.
The valve outlet must be maintained in good condition. When the cylinder is not in use, be sure to cover it with dust cap.
All gas connection should be checked for leaks utilising a soap solution. Never use a flame for this purpose.
This heater is designed to operate with a standard 1 LBs propane cylinder with Approved Cylinder Connection.
The gas manifold supply pressure must be regulated at 11 inches water column utilising an approved regulator.
The minimum inlet gas supply pressure for the purpose of input adjustment is 8 inches water column. The maximum inlet gas supply pressure is 13 inches water column.
LP-gas supply cylinder is not provided with the appliance,statements that
(1)the cylinder must be provided with a shut off valve
terminating in an LP-gas supply cylinder valve outlet
specified,as applicable,for connection No.510 in the standard for compressed gas cylinder valve outlet and inlet connections,ANSI/CGA-V-I,or connection No.600
in the compressed gas association's limited standard cylinder valve outlet connection for propane-small valve series.
(2)the cylinder supply system must be arranged for
vapor withdrawal;
(3)the cylinder used must include a collar to protect
the cylinder valve.
if a connection No.600 is used a statement that only
cylinders marked "propane" must be used.
PRECAUTIONSPRECAUTIONS
A leak test should be performed with soapy water
whenever connecting a new cylinder. Never use a match to test for leaks.
If disassembly is required, a leak test should be performed with soapy water upon re-assembly.