Napoleon Grills GD33NR User Manual

GD33NR Direct Vent Gas Fireplace Specifications

Specifications GD33NR
Fuel
Natural Gas Propane
BTU Input Natural Gas Propane
22,000 22,000
BTU Output Natural Gas Propane
17,000 17,400
Maximum Heating Efficiency (Steady State)
Natural Gas Propane
77.2% 79 %
Maximum Heating Efficiency (AFUE)
Natural Gas Propane
63% 63%
Additional Information
No chimney required ... vents through the wall or roof
4" & 7" rear venting
Overall depth of 12" makes for endless installation possibilities with a
minimum of space
No hearth extension required saving you space in smaller rooms
Ground level and above installations
Basement installations even below grade using a Periscope (#GD201)
Approved for installation in bathrooms, bedrooms and bed-sitting rooms
Suitable for mobile home installations
Hot air distribution kit optional
Approved with Simpson Dura-Vent Direct Vent Pipe
Rear vent
Dimensions
Venting Flexibility
TESTED TO ANSI Z21.86, Z21.88
CSA 2.32 and CSA 2.33
Line dimensions are to be used as a guide only. Please consult your installation manual
for updated and precise measurements before proceeding to install or frame your Napoleon Fireplaces.
Check all Local and National Building Codes and Gas Regulations
http://www.napoleonfireplaces.com/Webshare/gas/gas%20fireplaces/Specs_gd33nr.html7/12/2007 12:45:10 PM