BUILT-IN UNIT INSTRUCTION GUIDE
Please use this manual in conjuction with your main manual to properly assemble your built-in grill. Refer to the
main manual for operating, cleaning, and maintenance instructions. This grill is designed for non-combustible
enclosures only , and must be installed and serviced by a qualified installer to local codes.
BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping should be located as
shown in the built-in instructions. Do not use hose to connect the unit. It must be connected with either rigid pipe, copper tube or an
approved flexible metal connector. The installation must comply with CAN B149.1 Natural Gas and Propane installation code in
Canada, or to the National Fuel Gas code, ANSI Z223.1 in the United States. The minimum recommended piping size is NPS 1/2"
for rigid pipe, and 1/2" OD for copper tubing (based on a 20 ft run). Longer runs may require larger sizes to conform with CAN
B149.1. Propane Gas Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1 in the United States. The gas
supply must be connected to the 3/8” flare elbow fitting located under the right hand side of the control panel. If installing a side
burner, a separate line must be branched off to the side burner unit and enter the side burner opening at the specified location. If the
enclosure is to house a propane cylinder, the tank portion of the enclosure must be ventilated according to local codes, and must not
have communication with the cavity used to enclose the gas grill. The tank can not be stored below the gas grill.
BUILT IN NATURAL GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping should be located as
shown in the built-in instructions. Do not use hose to connect the unit. It must be connected with either rigid pipe, copper tube or an
approved flexible metal connector. The installation must comply with CAN B149.1 Natural Gas and Propane Installation Code in
Canada, or to the National Fuel Gas Code, ANSI Z223.1 in the United States. The minimum recommended piping size is NPS 1/2"
for rigid pipe, and 5/8" OD for copper tubing (based on a 20 ft run). Longer runs may require larger sizes to conform with CAN
B149.1. Natural Gas Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1 in the United States.
Built in units are supplied with a drip pan which holds only a minimal amount of grease. T oprevent grease fires, the panmust
be cleaned after each use.
N415-0107/APR28/06
BUILT-IN UNITOPENING DIMENSIONS
OUTDOOR GFIOUTLET
RECOMMENDED -LOCATE
ON LEFT SIDE OF GRILL
FOR ROTISSERIE USE.
BIPT450 / BIPT600 / BIPT750
BUILT-INGRILLHEADS
3”MIN.
BIU405 BUILT-IN
GRILL HEADS
6”
H
BUILT-IN
SIDEBURNER
W
H
D
1¾”
D
1¾”
2”
34”
RECOMMENDED
MINIMUM10SQINOF
VENTILATIONREQUIRED
ON EACH END OF CABINET
D
H
W
GASINLET
OPENING
4”
W
GASINLET
OPENING
WIDE 1 ¼”
OVERHANG NOTCHREQUIREDIF
USING SUPPLIEDTRIMKIT.
7”
DEPTH OF
COUNTERTOP
OVERHANG
GASINLET
OPENING
MODEL OPENINGDIMENSIONS
WDH
BIPT450 29 ½”20e”8f”
BIPT600 37 ¾”20e”8f”
BIPT750 49 ¾”20e”9e”
BIU405 27 ½”16¾” 12”
SIDEBURNER 13 ½”17½”4”
NOTES
Access must be provided for drip tray removal and cleaning.
Opening of at least 5 sq in must be provided for combustion air for side burner.
BUILT-INACCESSORYOPENING DIMENSIONS
NOTE:ACCESSORYFRAMES OVERLAP
OPENINGBY 1½” ONALL4SIDES
D
H
W
Part #
N370-0069 Flat vertical painted door
N370-0071
N370-0070
N370-0072
N370-0356SS Curved stainless steel door - 308 size
Flat vertical stainless steel door
Flat horizontal painted door
Flat horizontal stainless steel door
Description
Picture
OPENINGDIMENSION
WH
13¼”
18¼”
D
13¼” 18¼”
18¼” 13 ¼”
18¼” 13 ¼”
22½” 19 ¾”
N370-0357SS
N370-0358SS
N370-0361 PF style stainless steel door
N370-0359 PF style stainless steel single drawer
N370-0360 PF style stainless steel triple drawer
Curved stainless steel door - 450 size
Curved stainless steel double door - 600/750 size
27” 19 ¾”
35¼” 19”
17”
23¼”
17¼” 6 ¾”
17¼” 22 ¾”
23”
23”