Please use this manual in conjunction with your main manual to properly assemble your built-in grill. Refer to
the main manual for operating, cleaning, and maintenance instructions. This grill is designed for NON-COM-
BUSTIBLE enclosures only, and must be installed and serviced by a qualified installer to local codes.
BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping should be located as
shown in the built-in instructions. Do not use hose to connect the unit. It must be connected with either rigid pipe, copper tube or an
approved flexible metal connector. The installation must comply with CAN B149.1 Natural Gas and Propane installation code in
Canada, or to the National Fuel Gas code, ANSI Z223.1 in the United States. The minimum recommended piping size is NPS 1/2"
for rigid pipe, and 1/2" OD for copper tubing (based on a 20 ft run). Longer runs may require larger sizes to conform with local codes
or to conform with CAN B149.1. Propane Gas Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1 in the
United States. The gas supply must be connected to the 3/8” flare elbow fitting located under the right hand side of the control panel.
If installing a side burner, a separate line must be branched off to the side burner unit and enter the side burner opening at the
specified location. If the enclosure is to house a propane cylinder, the tank portion of the enclosure must be ventilated according to
local codes, and must not have communication with the cavity used to enclose the gas grill. A propane tank can not be stored below
the gas grill.
BUILT IN NATURAL GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping should be located as
shown in the built-in instructions. Do not use hose to connect the unit. It must be connected with either rigid pipe, copper tube or an
approved flexible metal connector. The installation must comply with CAN B149.1 Natural Gas and Propane Installation Code in
Canada, or to the National Fuel Gas Code, ANSI Z223.1 in the United States. The minimum recommended piping size is NPS 1/2"
for rigid pipe, and 5/8" OD for copper tubing (based on a 20 ft run). Longer runs may require larger sizes to conform with local codes
or to conform with CAN B149.1. Natural Gas Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1 in the
United States.
Built in units are supplied with a drip pan which holds only a minimal amount of grease. To prevent grease fires, the pan must
be cleaned after each use.
DANGER: READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING GRILL. FAILURE TO FOLLOW
THESE INSTRUCTIONS EXACTLY COULD RESULT IN A FIRE CAUSING SERIOUS INJURY OR DEATH.
N415-0175 / JAN 02/08
BUILT-IN UNIT OPENING DIMENSIONS
OUTDOOR GFI ELECTRICAL
OUTLET RECOMMENDED -
LOCATE ON LEFT SIDE OF
GRILL FOR ROTISSERIE
USE.
BIPT450 / BIPT600 / BIPT750
BUILT-IN GRILL HEADS
3” MIN.
BIU405 BUILT-IN
GRILL HEADS
6”
H
BUILT-IN
SIDEBURNER
W
H
D
1¾”
D
1¾”
2”
34”
RECOMMENDED
MINIMUM 10 SQ IN OF
VENTILATION REQUIRED
ON EACH END OF CABINET
D
H
W
GAS INLET
OPENING
4”
W
GAS INLET
OPENING
7”
GAS INLET
OPENING
NON-COMBUSTIBLE MATERIAL
MODELOPENING DIMENSIONS
W DH
BIPT450 29 1/2” 20 5/8” 8 7/8”
BIPT600 37 3/4” 20 5/8” 8 7/8”
BIPT75049 3/4” 20 5/8” 9 5/8”
BIU405271/2” 16 3/4” 12”
SIDE BURNER13 1/2” 17 1/2” 4”
CABINET FRAME AND CABINET MUST BE
MADE FROM NON-COMBUSTIBLE MATERIAL
NOTES
Access must be provided for drip tray removal and cleaning.
Opening of at least 5 sq in must be provided for combustion air for side burner.
BUILT-IN ACCESSORY OPENING DIMENSIONS
NOTE: ACCESSORY FRAMES OVERLAP
OPENING BY 1 ½” ON ALL 4 SIDES
D
H
W
Part #
N370-0069Flat vertical painted door
N370-0071
N370-0070
N370-0072
N370-0356SSCurved stainless steel door - 308 size
Flat vertical stainless steel door
Flat horizontal painted door
Flat horizontal stainless steel door
Description
Picture
OPENING DIMENSION
WH
13 ¼”
18 ¼”
D
13 ¼”18 ¼”
18 ¼”13 ¼”
18 ¼”13 ¼”
22 ½”19 ¾”
N370-0357SS
N370-0358SS
N370-0361PF style stainless steel door
N370-0359PF style stainless steel single drawer
N370-0360PF style stainless steel triple drawer
Curved stainless steel door - 450 size
Curved stainless steel double door - 600/750 size
27”19 ¾”
35 ¼”19”
17”
23 ¼”
17 ¼”6 ¾”
17 ¼”22 ¾”
23”
23”
1. BIPT450 BUILT-IN INSTRUCTIONS
N080-0213
N570-0026
N080-0213
N715-0080
N010-0568
This grill is designed for MASONRY, NON-COMBUSTIBLE enclosures only, and must be installed and serviced by a qualified installer
to local codes.
1. Attach side mounting brackets to each side of the grill using #14 x 1/2" screws (n570-0026).
2. Lay the rear trim piece across the back of the opening. To keep it in place, a dab of silicone may be applied to each wing of the
rear trim.
3. Lower the unit in place, and connect the gas supply line to the fitting at the end of the manifold.
4.The entire installation must be leak tested before operating the unit.
2. BIPT600 BUILT-IN INSTRUCTIONS
N080-0213
N715-0081
N380-0009
N051-0001
N080-0213
N010-0569
N570-0026
This grill is designed for MASONRY, NON-COMBUSTIBLE enclosures only, and must be installed and serviced by a qualified installer
to local codes.
1. Attach side mounting brackets to each side of the grill using #14 x 1/2" screws (n570-0026).
2. Lay the rear trim piece across the back of the opening. To keep it in place, a dab of silicone may be applied to each wing of the
rear trim.
3. Lower the unit in place, and connect the gas supply line to the fitting at the end of the manifold.
4.The entire installation must be leak tested before operating the unit.
3. BIPT750 BUILT-IN INSTRUCTIONS
N080-0213
N715-0082
N380-0009
N051-0001
N010-0570
N080-0213
N570-0026
This grill is designed for MASONRY, NON-COMBUSTIBLE enclosures only, and must be installed and serviced by a qualified installer
to local codes.
1. Attach side mounting brackets to each side of the grill using #14 x 1/2" screws (n570-0026).
2. Lay the rear trim piece across the back of the opening. To keep it in place, a dab of silicone may be applied to each wing of the
rear trim.
3. Lower the unit in place, and connect the gas supply line to the fitting at the end of the manifold.
4.The entire installation must be leak tested before operating the unit.