Napoleon Fireplaces GDS26N, GDS26P User Manual

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
INSTALLATION AND
OPERATION INSTRUCTIONS
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: ANSI Z21.88 • CSA 2.33 FOR VENTED GAS FIREPLACE HEATERS.
NATURAL GAS
GDS26P
1
PROPANE
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS.
SAFETY INFORMATION
!
WARNING
WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS: Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the supplier.
$10.00
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
www.napoleonfireplaces.com • ask@napoleon.on.ca
W415-0607 / A / 01.18.08
2
TABLE of CONTENTS
PG 3-5 INTRODUCTION
Warranty
General Instructions General Information Care of Glass and Plated Parts Dimensions
5-15 VENTING
Venting Lengths and Air Terminal Locations
Vent Installations Typical Vent Installations Special Vent Installations Minimum Air Terminal Location Clearances Venting Application Flow Chart Venting Specifi cations Vertical Through Existing Chimney Rear Exit Conversion
16-20 INSTALLATION
Wall and Ceiling Protection
Horizontal Installation Vertical Installation Stove Vent Connection Horizontal Venting Installation Vertical Venting Installation Mobile Home Installation Gas Installation Minimum Clearances to Combustibles Minimum Mantel, Shelf or Ceiling Clearances
21 BLOWER INSTALLATION 21 NIGHT LIGHTTM REPLACEMENT 22-23 FINISHING
Glass Door Installation and Removal
Logo Placement Glass Door Replacement Switch Functions Log Placement
24 WIRING DIAGRAM 25 OPERATION / MAINTENANCE Operating Instructions
Maintenance
26 ADJUSTMENTS Pilot Injector and Ori ce Replacement
Flame Adjustment and Characteristics Venturi Adjustment
27-28 REPLACEMENTS Ordering Replacement Parts
Replacement Parts Terminal Kits Accessories
29-30 TROUBLE SHOOTING GUIDE 31 SERVICE HISTORY 32 NOTES
RETAIN THIS MANUAL FOR FUTURE REFERENCE
!
WARNING
• Do not burn wood or other materials in this stove.
• Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the stove.
• Clothing or other fl ammable material should not be placed on or near the stove.
• Due to high temperatures, the stove should be located out of traffi c and away from furniture and draperies.
• Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot surfaces.
• Even after the stove is out, the glass and/or screen will remain hot for an extended period of time.
• Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces. These screens and guards must be fastened to the fl oor.
• Any safety screen or guard removed for servicing must be replaced prior to operating the stove.
• It is imperative that the control compartments, burners and circulating blower and its passageway in the stove and venting system are kept clean. The stove and its venting system should be inspected before use and at least annually by a qualifi ed service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The stove area must be kept clear and free from combustible materials, gasoline and other fl ammable vapours and liquids.
• Under no circumstances should this stove be modifi ed.
• This stove must not be connected to a chimney fl ue pipe serving a separate solid fuel burning appliance.
• Do not use this stove if any part has been under water. Immediately call a qualifi ed service technician to inspect the stove and to replace any part of the control system and any gas control which has been under water.
• Do not operate the stove with the glass door removed, cracked or broken. Replacement of the glass should be done by a licensed or qualifi ed service person.
• Do not strike or slam shut the stove glass door.
• This stove uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
• Pressure relief doors must be kept closed while the stove is operating to prevent exhaust fumes containing carbon monoxide, from entering into the home. Temperatures of the exhaust escaping through these openings can also cause the surrounding combustible materials to overheat and catch fi re.
• Only doors / optional fronts certifi ed with the unit are to be installed on the appliance.
W415-0607 / A / 01.18.08
NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.
NAPOLEON® products are manufactured under the strict Standard of the world recognized
ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi red at a quality test station. The complete stove is test-fi red and thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON®
.
NAPOLEON® GAS STOVE PRESIDENT'S LIFETIME LIMITED WARRANTY
The following materials and workmanship in your new NAPOLEON® gas stove are warranted against defects for as long as you own the stove. This covers: combustion chamber, heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled components and aluminium extrusion trims.
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves, thermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are covered and NAPOLEON® will provide replacement parts free of charge during the fi rst year of the limited warranty. Light bulbs are not covered by this warranty.
Labour related to warranty repair is covered free of charge during the fi rst year. Repair work however, requires the prior approval of an authorized company offi cial. Labour costs to the account of Napoleon® are based on a predetermined rate schedule and any repair work must be done through an authorized Napoleon® dealer.
3
CONDITIONS AND LIMITATIONS
NAPOLEON® warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity
(registered customer) whose name appears on the warranty registration card fi led with NAPOLEON® -- provided that the purchase was made through an authorized NAPOLEON® dealer and is subject to the following conditions and limitations:
This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives. The gas stove must be installed by a licensed, authorized service technician or contractor. Installation must be done in accordance
with the installation instructions included with the product and all local and national building and fi re codes.
This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and
parts installed from other manufacturers will nullify this warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and
chemical cleaners nor chipping on porcelain enamel parts, mechanical breakage of PHAZER™ logs and embers, nor any venting components used in the installation of the stove.
NAPOLEON® warrants its stainless steel burners against defects in workmanship and material for life, subject to the following
conditions: During the fi rst 10 years NAPOLEON® will replace or repair the defective parts at our option free of charge. From 10 years to life, NAPOLEON® will provide replacement burners at 50% of the current retail price.
In the fi rst year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship
provided that the product has been operated in accordance with the operation instructions and under normal conditions.
After the fi rst year, with respect to this President's Limited Lifetime Warranty, NAPOLEON® may, at its discretion, fully discharge
all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).
After the fi rst year, NAPOLEON® will not be responsible for installation, labour or any other costs or expenses related to the reinstallation
of a warranted part, and such expenses are not covered by this warranty.
Notwithstanding any provisions contained in this President's Limited Lifetime Warranty, NAPOLEON®’S responsibility under this warranty
is defi ned as above and it shall not in any event extend to any incidental, consequential or indirect damages.
This warranty defi nes the obligations and liability of NAPOLEON® with respect to the NAPOLEON® gas stove and any other warranties
expressed or implied with respect to this product, its components or accessories are excluded.
NAPOLEON® neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this
product. NAPOLEON® will not be responsible for: over-fi ring, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting confi gurations, insuffi cient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
Any damages to stove, combustion chamber, heat exchanger, brass trim or other component due to water, weather damage, long
periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON®.
The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your
authorized dealer. The warranty registration card must be returned within fourteen days to register the warranty.
ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGIS­TERED TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD. THIS PRODUCT HAS AN INDUSTRIAL DESIGN REGISTRATION
W415-0607 / A / 01.18.08
4
GENERAL INSTRUCTIONS GENERAL INFORMATION
THIS GAS STOVE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes.
Installation practices vary from region to region and it is important to know the specifi cs that apply to your area, for example: in Massachusetts State:
• The stove damper must be removed or welded in the open position prior to installation of a stove insert or gas log.
A carbon monoxide detector is required in all rooms containing
gas fi red appliances.
• The appliance off valve must be a “T” handle gas cock.
• The fl exible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.
• WARNING: This product must be installed by a licensed plumber or gas fi tter when installed within the commonwealth of Massachusetts.
In absence of local codes, install to the current CAN1-B149 Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1, and NFPA 54 in the United States. Mobile home installation must conform with local codes. In the absence of local codes, install to the current standard for gas equipped mobile housing CAN/CSA Z240 MH Series in Canada or the manufactured home construction and safety standard, Title 24 CFR, part 3280, or the Fire Safety Criteria for manufactured home installations, Sites and Community
Standard ANSI/NFPA 501A in the United States.
Objects placed in front of the stove must be kept a minimum of 48" away from the front face of the unit.
The stove and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psig (3.5 kPa). The stove must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.5 kPa).
FOR YOUR SATISFACTION, THIS STOVE HAS BEEN TEST­FIRED TO ASSURE ITS OPERATION AND QUALITY!
Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. When the valve is set to "HI", the manifold pressure under fl ow conditions is 3.5 inches water column for natural gas and 10 inches water column for propane. When the stove is installed at elevations above 4,500ft, and in the absence of specifi c recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft. Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used.
Maximum input is 25,000 BTU/hr for natural gas and propane. Maximum output is 20,500 BTU/hr at an effi ciency of 82%.
Provide adequate accessibility clearance for servicing and operating the stove.
Never obstruct the front opening of the stove. Provided that the clearance to combustibles are achieved, the most desirable and benefi cial location for a Napoleon® stove is in the centre of a building, thereby allowing the most effi cient use of the heat created. The location of windows, doors and the traffi c fl ow in the room where the stove is to be located should be considered. If possible, you should choose a location where the vent will pass through the house without cutting a fl oor or roof joist.
Rating Label Location: The rating label is located behind the control door and is chained to the stove.
DO NOT REMOVE.
The stove, when installed with a blower, must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/ NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
W415-0607 / A / 01.18.08
CARE OF GLASS AND PLATED PARTS
Do not use abrasive cleaners to clean these parts. Buff lightly with a clean dry cloth. The glass is 3/16" ceramic glass available from your Napoleon® / Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE MATERIALS. Clean the glass after the fi rst 10 hours of operation with a recommended gas stove glass cleaner. Thereafter clean as required. DO NOT CLEAN GLASS WHEN HOT! If the glass is not kept clean permanent discolouration and / or blemishes may result.
FIGURE 1a
DIMENSIONS
FIGURE 1b FIGURE 1c
1
29
351/2
/8”
37”
GAS LINE ACCESS
4” DIA.
23
5
/8”
5
7” DIA.
181/8”
VENTING
VENTING LENGTHS AND AIR TERMINAL LOCATIONS
Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp or American Metal Amerivent venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-Vent, Selkirk Direct Temp and American Metal Amerivent, follow the installation procedure provided with the venting components. All outer pipe joints of these venting systems must be sealed using Red RTV High Temperature Sealant. The connection between the adaptor for these systems and the stove fl ue collar must be sealed using the black high temperature sealant Mill Pac (not supplied). A starter adaptor must be used with the following vent systems and may be purchased from the corresponding supplier:
PART 4"/7" SUPPLIER
Duravent GDS924N Wolf Steel Amerivent 4DSCB-N1 American Metal Direct Temp 4DT-AAN Selkirk
For Simpson Dura-Vent, Selkirk Direct Temp and American Metal Amerivent, follow the installation procedure found on the website for your venting supplier:
VENTING SUPPLIER WEBSITE ADDRESS
Simpson Dura-Vent www.duravent.com Selkirk Direct Temp www.selkirkcorp.com
American Metal Amerivent www.americanmetalproducts.com
For vent systems that provide seals on the inner exhaust ue, only the outer air intake joints must be sealed using a red high temperature silicone (RTV). This same sealant
ELECTRICAL
ACCESS
may be used on both the inner exhaust and the outer intake vent pipe joints of all other approved vent systems except for the exhaust vent pipe connection to the stove fl ue collar which must be sealed using the black high temperature sealant Mill Pac. When using Wolf Steel venting components, use only approved Wolf Steel rigid / fl exible components with the following termination kits:Wall Terminal Kit GD222, or 1/12 to 7/12 Pitch Roof Terminal Kit GD110, 8/12 to 12/12 Roof Terminal Kit GD111, Flat Roof Terminal Kit GD112 or Periscope Kit GD201 (for wall penetration below grade). Also approved for use with Duravent's co-axial to co-linear adaptor for installations using an existing chimney.
The maximum allowable vertical vent length is 40 feet, the minimum allowable vertical vent length is 3 feet.
For optimum fl ame appearance and stove performance, keep the vent length and number of elbows to a minimum. The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged. Horizontal runs may have a 0" rise per foot in all cases using Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent rigid venting components or Wolf Steel fl exible venting components. For optimum performance, it is recommended that horizontal runs have a minimum 1" rise per foot when using Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Wolf Steel rigid / fl exible vent components. Wolf Steel, Simpson Dura-vent, Selkirk Direct Temp, and American Metal Amerivent venting systems must not be combined.
VENT INSTALLATIONS
For safe and proper operation of the stove follow the venting instruction exactly. Deviation from the minimum or the maximum vertical vent length can create diffi culty in burner start-up and/or carboning. Under extreme vent confi gurations, allow several minutes (5-15) for the fl ame to stabilize after ignition. Vent lengths that pass through unheated spaces (attics, garages, crawl spaces) should be insulated with the insulation wrapped in a protective sleeve to minimize condensation. Use a fi restop, vent pipe shield or attic insulation shield when penetrating interior walls, fl oor or ceiling.
FOR SPECIFIC VENTING PARAMETERS, REFER TO PAGES 9-13.
W415-0607 / A / 01.18.08
6
6” RISE
HORIZONTAL VENT SECTIONS: A minimum clearance of 1" at the bottom and sides and 2" at the top of the vent pipe in all horizontal runs to combustibles is required. Use fi restop spacer W010-1313 and shield W585-0240 (supplied).
TYPICAL VENT INSTALLATIONS
REAR EXIT TOP EXIT
FIGURE 2a
40 FT MAXIMUM
3 FT MINIMUM
FIGURE 2b
16”
MINIMUM
20" MAXIMUM
VERTICAL VENT SECTIONS: A minimum of 1" all around the vent pipe on all vertical runs to combustibles is required. Use fi restop spacer W010- 1313 (supplied).
FIGURE 3a
40 FT MAXIMUM
3 FT MINIMUM
FIGURE 3b
16”
MINIMUM
24" MAXIMUM
1
/2"
35
1
/8" MINIMUM
29
PLUS RISE*
* Refer to "Venting" Section
SPECIAL VENT INSTALLATIONS
PERISCOPE TERMINATION
Use the GD201 periscope kit to locate the air termination above grade. The periscope must be installed so that when nal grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allowable vent length is 10 ft.
FIGURE 4a
12” MINIMUM
FIGURE 4b
12” MINIMUM
10"
MINIMUM
1
/2" MINIMUM
45
PLUS RISE*
1
35
/2"
CORNER TERMINATION
The maximum vent length for a corner installation is 20" of horizontal run, in addition to the 45° offset. In this case zero rise is acceptable. See FIGURE 5a. It is recommended to maintain a 6" rise. See FIGURE 5b.
FIGURE 5a
20” MAXIMUM
FIGURE 5b
MINIMUM
24”
MINIMUM
W415-0607 / A / 01.18.08
MAXIMUM 10FT VENT LENGTH
MINIMUM
24”
MINIMUM AIR TERMINAL LOCATION CLEARANCES
FIGURE 6
7
W415-0607 / A / 01.18.08
8
TOP EXIT
Vertical rise
Vertical Termination
Vertical rise
is less than
horizontal
run
Vertical rise
is equal to
or greater
than the
is less than
horizontal
run
Horizontal
run + verti-
cal rise to
maximum
of 40 feet
horizontal
run
Horizontal
run + verti-
cal rise to
Horizontal
run + verti-
cal rise to
maximum of
maximum
of 40 feet
24.75 feet
3 times the
vertical rise
equal to or
greater than
the horizon-
4.2 times the
vertical rise
equal to or
greater than
the horizon-
tal run
tal run
VENTING APPLICATION FLOW CHART
STOVE VENT EXIT
REAR EXIT
Horizontal Termination
Vertical rise
Vertical rise
Vertical Termination
Vertical rise
Vertical rise
is equal to
or greater
than the
horizontal
run
is less than
horizontal
run
is equal to
or greater
than the
horizontal
run
is less than
horizontal
run
Horizontal
run + verti-
cal rise to
Horizontal
run + verti-
cal rise to
Horizontal
run + verti-
cal rise to
Horizontal
run + verti-
cal rise to
maximum of
maximum
of 40 feet
maximum
of 40 feet
maximum
of 40 feet
24.75 feet
3 times the
vertical rise
equal to or
greater than
the horizon-
3.5 times the
vertical rise
equal to or
greater than
the horizon-
tal run
tal run
W415-0607 / A / 01.18.08
Horizontal Termination
Vertical rise
is equal to
or greater
than the
horizontal
run
Horizontal
run + verti-
cal rise to
maximum
of 40 feet
9
DEFINITIONS
for the following symbols used in the venting calculations and examples are:
> - greater than > - equal to or greater than < - less than < - equal to or less than HT - total of both horizontal vent lengths (HR) and offsets (HO) in feet HR - combined horizontal vent lengths in feet HO - offset factor: .03(total degrees of offset - 90°*) in
feet
VT - combined vertical vent lengths in feet
TOP EXIT / HORIZONTAL TERMINATION
(HT) < (VT)
Simple venting confi guration (only one 90° elbow)
FIGURE 7
ELBOW VENT LENGTH VALUES
feet inches 0.03 0.5 15° 0.45 6.0 30° 0.9 11.0 45° 1.35 16.0 90°* 2.7 32.0
* the fi rst 90° offset has a zero value and is shown in the formula as -90°
For vent confi gurations requiring more than one 90° elbow, the following formulas apply:
Formula 1: HT < V
T
Formula 2: HT + VT < 40 feet
90°
H
2
See graph to determine the required vertical rise VT for the required horizontal run HT.
39
VERTICAL RISE IN FEET
V
T
HORIZONTAL VENT RUN PLUS OFFSET IN FEET
The shaded area within the lines represents acceptable values for HT and V
40
30
20
10
0
2.5 5 7.5 10 12.5 15
.
T
17.5 20
H
T
V
2
FIGURE 8
90°
V
H
1
1
90°
Example 1:
V1 = 3 ft V2 = 8 ft VT = H1 = 2.5 ft H2 = 2 ft HR = H1 + H2 = 2.5 + 2 = 4.5 ft HO = . HT = HR + HO = 4.5 + 5.4 = 9.9 ft
HT + VT = 9.9 + 11 = 20.9 ft
Formula 1: H
Formula 2: HT + VT < 40 feet
20.9 < 40 Since both formulas are met, this vent confi guration is acceptable.
V1 +
V2 =
3 + 8 = 11 ft
03(three 90° elbows - 90°) = .03(270° - 90°) = 5.4 ft
< V
T
T
9.9 < 11
W415-0607 / A / 01.18.08
10
TOP EXIT / HORIZONTAL TERMINATION
(HT) > (VT)
Simple venting confi guration (only one 90° elbow)
See graph to determine the required vertical rise VT for the required horizontal run HT.
150
REQUIRED VERTICAL RISE IN INCHES
V
T
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0 5 10 15
HORIZONTAL VENT RUN PLUS OFFSET IN FEET H
The shaded area within the lines represents acceptable values for H
and V
T
.
T
For vent confi gurations requiring more than one 90° elbow the following formulas apply:
Formula 1: HT < 4.2 V
T
Formula 2: HT + VT < 24.75 feet
FIGURE 9
20
T
90°
Example 2:
V H1 = 3 ft H2 = 5 ft HR = H1 + H2 = 3 + 5 = 8 ft HO = .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft HT = HR + HO = 8 + 2.7 = 10.7 ft HT + VT =
Formula 1: HT < 4.2 V
4.2 V
= VT = 6 ft
1
10.7 + 6 =16.7
T
= 4.2 x 6 = 25.2 ft
T
10.7 < 25.2
Formula 2: HT + VT < 24.75 feet
16.7 < 24.75
Since both formulas are met, this vent confi guration is ac- ceptable.
Example 3:
H
3
90°
H
4
V
2
H
V
V
1
V
2
VT = V1 + V2 = 4 + 1.5 = 5.5 ft
1
1
= 4 ft = 1.5 ft
H1 = 2 ft H2 = 1 ft H3 = 1 ft H4 = 1.5 ft HR = H1 + H2 + H3 + H4 = 2 + 1 + 1 + 1. 5 = 5.5 ft HO = .03(four 90° elbows - 90°) = .03(360° - 90°) = 8.1 ft HT = HR + HO = 5.5 + 8.1 = 13.6 ft HT + VT = 13.6 + 5.5 = 19.1 ft
Formula 1: HT < 4.2 V
4.2 V
13.6 < 23.1
Formula 2: HT + VT < 24.75 feet
19.1 < 24.75
H
2
FIGURE 11
T
= 4.2 x 5.5 = 23.1 ft
T
V
1
W415-0607 / A / 01.18.08
H
H
1
2
Since both formulas are met, this vent confi guration is acceptable.
FIGURE10