INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPL ACE HEATERS
GAS - DIRECT VENT MILLIVOLT SYSTEM
INSTALLATION AND OPERATION INSTRUCTIONS FOR
LISTED DIRECT VENTED GAS-FIRED WALL FURNACE
1
NATURAL GAS MODEL
PROPANE GAS MODEL
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS
GD45-NGD45-P
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapours and liquids in the vicin-
ity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your build
ing.
•Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
•If you cannot reach your gas supplier,
call the fire department.
Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
www.napoleonfireplaces.com • ask@napoleon.on.ca
W415-0100 / D / 01.13.04
Page 2
2
TABLE of CONTENTS
PG2-5INTRODUCTION
Warranty
General Instructions
General Information
Care of Glass & Plated Parts
5-8VENTING
Vent Lengths
Venting Options
Air Terminal Locations
9-13 INSTALLATION / FRAMING
Horizontal Venting Installation
Vertical Venting Installation
Restricting Vertical Vents
Fireplace Vent Connection
Installation
Framing
Mantle Clearances and Enclosures
Mobile Home Installation
14
GAS INSTALLATION
14-16
FINISHING
Brick Panel Installation
Log Placement
Door Opening, Trim & Louvres
17OPTIONAL BLOWER INSTALLATION
18
OPTIONAL FAN INSTALLATION
OPTIONAL THERMOSTATIC SENSOR
19-20
OPERATION / MAINTENANCE
Operating Instructions
Maintenance
20ADJUSTMENTS
Pilot Burner Adjustment
Venturi Adjustments
21-22
REPLACEMENTS
Ordering Replacement Parts
Replacement Parts
Terminal Kits
Vent Kits
Accessories
23-24 TROUBLE SHOOTING GUIDE
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
WARNING
• Do not burn wood or other materials in this fireplace.
• Adults and especially children should be alerted to the hazards of high surface temperatures and should stay
away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the
fireplace.
• Due to high temperatures, the fireplace should be located out of traffic and away from furniture and draperies.
• Clothing or other flammable material should not be placed on or near the fireplace.
• Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace.
• It is imperative that the control compartments, burners and circulating blower and its passageway in the fireplace and venting system are kept clean. The fireplace and its venting system should be inspected before use
and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint
from carpeting, bedding material, etc. The fireplace area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids.
• Under no circumstances should this fireplace be modified.
• This fireplace must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.
• Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to
inspect the fireplace and to replace any part of the control system and any gas control which has been under
water.
• Do not operate the fireplace with the glass door removed, cracked or broken. Replacement of the glass should
be done by a licensed or qualified service person.
• Do not strike or slam shut the fireplace glass door.
• This fireplace uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple
supplied by Wolf Steel Ltd.
NOTE: CHANGES, OTHER THAN EDITORIAL, ARE DENOTED BY A VERTICAL LINE IN THE MARGIN.
W415-0100 / D / 01.13.04
Page 3
NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized
ISO 9001 : 2000 Quality Assurance Certificate.
NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen
who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test
station. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that
you, the customer, receives the quality product that you expect from NAPOLEON.
NAPOLEON GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY
The following materials and workmanship in your new napoleon gas fireplace are warrantedThe following materials and workmanship in your new napoleon gas fireplace are warranted
The following materials and workmanship in your new napoleon gas fireplace are warranted
The following materials and workmanship in your new napoleon gas fireplace are warrantedThe following materials and workmanship in your new napoleon gas fireplace are warranted
against defects for as long as you own the fireplace. This covers: combustion chamber, heatagainst defects for as long as you own the fireplace. This covers: combustion chamber, heat
against defects for as long as you own the fireplace. This covers: combustion chamber, heat
against defects for as long as you own the fireplace. This covers: combustion chamber, heatagainst defects for as long as you own the fireplace. This covers: combustion chamber, heat
exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakageexchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage
exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakageexchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage
only), gold plated parts against tarnishing, porcelainized enamelled components and aluminumonly), gold plated parts against tarnishing, porcelainized enamelled components and aluminum
only), gold plated parts against tarnishing, porcelainized enamelled components and aluminum
only), gold plated parts against tarnishing, porcelainized enamelled components and aluminumonly), gold plated parts against tarnishing, porcelainized enamelled components and aluminum
extrusion trims.extrusion trims.
extrusion trims.
extrusion trims.extrusion trims.
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,
thermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly arethermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are
thermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are
thermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly arethermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are
covered and covered and
covered and
covered and covered and
the limited warranty.the limited warranty.
the limited warranty.
the limited warranty.the limited warranty.
Labour related to warranty repair is covered free of charge during the first year. Repair work,Labour related to warranty repair is covered free of charge during the first year. Repair work,
Labour related to warranty repair is covered free of charge during the first year. Repair work,
Labour related to warranty repair is covered free of charge during the first year. Repair work,Labour related to warranty repair is covered free of charge during the first year. Repair work,
however, requires the prior approval of an authorized company official. Labour costs to thehowever, requires the prior approval of an authorized company official. Labour costs to the
however, requires the prior approval of an authorized company official. Labour costs to the
however, requires the prior approval of an authorized company official. Labour costs to thehowever, requires the prior approval of an authorized company official. Labour costs to the
account of account of
account of
account of account of
be done through an authorized be done through an authorized
be done through an authorized
be done through an authorized be done through an authorized
NAPOLEONNAPOLEON
NAPOLEON
NAPOLEONNAPOLEON
NAPOLEONNAPOLEON
NAPOLEON
NAPOLEONNAPOLEON
will provide replacement parts free of charge during the first year ofwill provide replacement parts free of charge during the first year of
will provide replacement parts free of charge during the first year of
will provide replacement parts free of charge during the first year ofwill provide replacement parts free of charge during the first year of
are based on a predetermined rate schedule and any repair work must are based on a predetermined rate schedule and any repair work must
are based on a predetermined rate schedule and any repair work must
are based on a predetermined rate schedule and any repair work must are based on a predetermined rate schedule and any repair work must
NAPOLEONNAPOLEON
NAPOLEON
NAPOLEONNAPOLEON
dealer. dealer.
dealer.
dealer. dealer.
3
CONDITIONS AND LIMITATIONS
NAPOLEON warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears on the
warranty registration card filed with NAPOLEON -- provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following conditions and limitations:
This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.
The gas fireplace must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the
product and all local and national building and fire codes.
This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify
this warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel
parts, mechanical breakage of PHAZER™ logs and embers, nor any venting components used in the installation of the fireplace.
NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During the first 10 years NAPOLEON will replace
or repair the defective parts at our option free of charge. From 10 years to life, NAPOLEON will provide replacement burners at 50% of the current retail price.
In the first year only, this warranty extends to the repair or replacement of warranted part s which are defective in material or workmanship provided that the product has been operated
in accordance with the operation instructions and under normal conditions.
After the first year, with respect to this President's Limited Lifetime W arranty, NAPOLEON may , at it s discretion, fully discharge all obligations with respect to this warranty by refunding
to the original warranted purchaser the wholesale price of any warranted but defective part(s).
After the first year, NAPOLEON will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not
covered by this warranty.
Notwithstanding any provisions contained in this President's Limited Lifetime Warranty , NAPOLEON’S responsibility under this warranty is defined as above and it shall not in any event
extend to any incidental, consequential or indirect damages.
This warranty defines the obligations and liability of NAPOLEON with respect to the NAPOLEON gas fireplace and any other warranties expressed or implied with respect to this product,
its components or accessories are excluded.
NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. NAPOLEON will not be responsible
for: over-firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting
configurations, insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
Any damages to fireplace, combustion chamber, heat exchanger, brass trim or other component due to water, weather damage, long periods of dampness, condensation, damaging
chemicals or cleaners will not be the responsibility of NAPOLEON.
The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration
card must be returned within fourteen days to register the warranty.
NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.
This gas fireplace should be installed and serviced by a
qualified installer to conform with local codes. Installation
practices vary from region to region and it is important to
know the specifics that apply to your area,
for example: in Massachusetts State:
• The fireplace damper must be removed or welded in the open
position prior to installation of a fireplace insert or gas log.
• The appliance off valve must be a “T” handle gas cock.
• The flexible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bedroom or
bathroom unless the unit is a direct vent sealed combustion
product.
• WARNING: This product must be installed by a licensed plumber
or gas fitter when installed within the commonwealth of
Massachusetts.
In absence of local codes, install to the current CAN/CGA B149 Installation Code in Canada or to the National Fuel
Gas Code, ANSI Z223.1, and NFPA 54 in the United States.
Suitable for mobile home installation if installed in
accordance with the current standard CAN/CSA Z240MH
Series, for gas equipped mobile homes, in Canada or ANSI
Z223.1 and NFPA 54 in the United States.
The fireplace and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2
psig (3.5 kPa). The fireplace must be isolated from the gas
supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than
1/2 psig (3.5 kPa).
When the fireplace is installed directly on carpeting, vinyl tile
or other combustible material other than wood flooring, the
fireplace shall be installed on a metal or wood panel extending the full width and depth.
The optional heat circulating blower is supplied with a cord. If
installed, the junction box must be electrically connected and
grounded in accordance with local codes. In the absence of
local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL
ELECTRICAL CODE in the United States.
Mobile home installation must conform with local codes. In
the absence of local codes, install to the current standard
for gas equipped mobile housing CAN/CSA Z240 MH Series in Canada or the manufactured home construction
and safety standard, Title 24 CFR, part 3280, or the Fire
Safety Criteria for manufactured home installations, Sites
and Community Standard ANSI/NFPA 5OIA in the United
States.
FOR YOUR SA TISF ACTION, THIS FIREPLACE HAS BEEN
TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! Maximum input is 45,000 BTU/hr for natural gas and
40,000BTU/hr for propane. When the fireplace is installed
at elevations above 4,500ft, and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced
at the rate of 4% for each additional 1,000ft. Maximum output for natural gas is 36,900 BTU/hr at an efficiency of 82%
with the fan on, 78.4% with the fan off; and 33,200 BTU/hr
for propane at an efficiency of 83% with the fan on, 80%
with the fan off. Minimum A.F.U.E. (Annual Fuel Utilization
Efficiency) rating is 64%.
Minimum inlet gas supply pressure is 4.5 inches water
column for natural gas and 11 inches water column for
propane. Maximum inlet gas pressure is 7 inches water
column for natural gas and 13 inches water column for
propane. Manifold pressure under flow conditions is 3.5
inches water column for natural gas and 10 inches water
column for propane.
This fireplace is approved for bathroom, bedroom and bedsitting room installations and is suitable for mobile home
installation.
No external electricity (110 volts or 24 volts) is required
for the gas system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected. Change
in flame appearance from "HI" to "LO" is more evident in
natural gas than in propane.
CARE OF GLASS, AND PLATED PARTS
Do not use abrasive cleaners to clean plated parts. Buff lightly
with a clean dry cloth. The glass is 3/16" ceramic glass available from your Napoleon / Wolf Steel Ltd. dealer. DO NOT
SUBSTITUTE MATERIALS. Clean the glass after the first 10
hours of operation with a recommended gas fireplace glass
cleaner. Thereaf ter clean as required. DO NOT CLEAN GLASS
WHEN HOT! If the glass is not kept clean permanent discolouration and / or blemishes may result.
Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and
operating the fireplace.
Never obstruct the front opening of the fireplace.
Objects placed in front of the fireplace must be kept a
minimum of 48" away from the front face of the unit.
W415-0100 / D / 01.13.04
FIGURE 1
Page 5
Minimum clearance to combustible construction from fireplace and vent surfaces:
sides, back, bottom, and top0 inches
vent pipe1 inch
recessed depth22 inches
5
• Under extreme vent configurations, allow several minutes (5-15) for the flame to stabilize after ignition.
• Eight (8") inches is the minimum bend radius allowed for
the 7" diameter flexible air liner.
VENTING
VENTING LENGTHS
Use only Napoleon or Simpson Dura-Vent Model DV-GS
venting components. Minimum and maximum vent lengths,
for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual
and must be adhered to.
When using Napoleon venting components, use only the
following vent kits: WALL TERMINAL KIT GD-222R, or 1/12
TO 7/12 PITCH ROOF TERMINAL KIT GD-110, 8/12 TO 12/
12 ROOF TERMINAL KIT GD-1 1 1, FLA T ROOF TERMINAL
KIT GD-112 or PERISCOPE KIT GD-201 (for wall penetration below grade) in conjunction with the various terminations, use either the 5 foot vent kit GD-220 or the 10 foot
vent kit GD-330 For Simpson Dura-Vent, follow the inst allation procedure provided with the venting components.
These vent kits allow for either horizontal or vertical venting
of the fireplace. The maximum number of 4" flexible connections is four (excluding the fireplace and the air terminal connections).
For optimum flame appearance and fireplace performance,
keep the vent length and number of elbows to a minimum.
The air terminal must remain unobstructed at all times.
Examine the air terminal at least once a year to verify that it
is unobstructed and undamaged.
• All horizontal runs must have a
cases using Napoleon flexible venting components.
• Horizontal runs can have a 0 inch rise per foot using
Simpson Dura-Vent or Napoleon rigid venting components.
For optimum performance, it is recommended that all horizontal runs have a minimum ¼ inch rise per foot using
rigid venting.
• Provide a means for visually checking the vent connection to the fireplace after the fireplace is installed.
• Do not allow the inside liner to bunch up on horizontal or
vertical runs and elbows. Keep it pulled tight. A 1¼" air
gap between the inner and outer liner all around is required for safe operation.
• Use a firestop when penetrating interior walls, floor or
ceiling.
• For safe and proper operation of the fireplace follow the
venting instruction exactly.
• Deviation from the minimum vertical vent length can create difficulty in burner start-up and/or carboning.
• Vent lengths that pass through unheated spaces (attics,
garages, crawl space) should be insulated with the insulation wrapped in a protective sleeve to minimize condensation.
• Purge all gas lines with the glass door of the fireplace
open. Assure that a continuous gas flow is at the burner
before closing the door.
1 inch rise per foot in all
When terminating vertically, the
vertical rise is a minimum 36
inches and a maximum 40 feet
above the fireplace.
FIGURE 2
Do not radius vertical vent
rises.
FIGURE 3
FIGURES 4a
When venting, the immediate horizontal run must be kept
minimum of 10 inches or a maximum of 3 feet.
to a
FIGURES 4b
W415-0100 / D / 01.13.04
Page 6
6
Use the venting option charts to calculate vertical rises for horizontal runs between 3 and 20 feet.
When calculating maximum run lengths, include 10 feet for each 90° elbow or 5 feet for each 45° elbow. (DO NOT
INCLUDE THE FIRST ELBOW DIRECTLY OFF THE UNIT .)
VENTING OPTION #1
Use this chart to calculate vertical rise for horizontal run between 1 foot (maximum
length when the vertical rise is at its minimum of 1 foot) and 8 feet.
FIGURES 5
VERTICAL
RISE in feet
8 FT MAX
(1 FT MAX)
HORIZONT AL VENT RUN
in feet
40 FT MAX
1 FT MIN
VENTING OPTION #2
Use this chart to calculate vertical rise for horizontal run between 3 feet (maximum length when the vertical rise is at its
minimum of 1 foot) and 20 feet.
VERTICAL
RISE in feet
W415-0100 / D / 01.13.04
HORIZONT AL VENT RUN
in feet
20 FT MAX
(3 FT MAX)
FIGURES 6
20 FT MAX
1 FT MIN
When venting, the horizontal run must be kept to a
minimum of 10 inches or a maximum of 20 feet.
Page 7
VENTING OPTION #3
Use this chart to calculate the vertical rise when using a total of 2 horizontal runs. When the vertical rise is at its minimum
of 1 foot, the first horizontal run can be a maximum of 2 feet and 1 foot maximum for the second run. When the vertical rise
is at its maximum of 20 feet, the first horizontal run can be a maximum of 8 feet and 10 feet maximum for the second run.
10 FT MAX
(1 FT MAX)
FIGURES 7
20 FT MAX
VERTICAL
RISE in feet
8 FT MAX
(2 FT MAX)
COMBINED HORIZON-
TA L VENT RUN in feet
1 FT MIN
7
VENTING OPTION #4
Use this chart to calculate the total vertical rise required when the horizontal run is between 18 feet maximum or
3 feet maximum length when the initial vertical rise is at its minimum of 1 foot.
34 FT MAX
(1 FT MAX)
COMBINED
VERTICAL
RISE in feet
FIGURES 8
HORIZONT AL VENT RUN
in feet
18 FT MAX
(3 FT MAX)
6 FT MAX
1 FT MIN
W415-0100 / D / 01.13.04
Page 8
8
i
AIR TERMINAL INSTALLATIONS
FIGURE 9
INSTALLATIONS
CANADIANU.S.A.
A
12 INCHES
12 INCHES
Clearance above grade, veranda porch, deck or balcony.
B
C
12 INCHES
12 INCHES*
9 INCHES
12 INCHES*
Clearance to windows or doors that open.
Clearance to permanently closed windows.
Vertical clearance to ventilated soffit located above the terminal within
D
18 INCHES**
12 INCHES**
E
F
0 INCHES
0 INCHES***
G
2 INCHES***
H
I
J
K
L
M
N
O
**
*Recommended to prevent condensation on windows and thermal breakage
**
****
**It is recommended to use a heat shield and to maximize the distance to vinyl clad soffits.
****
******
***The periscope GD-201 requires a minimum 18 inches clearance from an inside corner.
******
********
**** This is a recommended distance. For additional requirements check local codes.
********
††
†Three feet above if within 10 feet horizontally.
††
‡‡
‡A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single fam
‡‡
††††
††Permitted only if the veranda, porch, or deck is fully open on a minimum of two sides beneath the floor.
††††
†*†*
†*Recommenced to prevent recirculation of exhaust products. For additional requirements check local codes.
†*†*
W415-0100 / D / 01.13.04
3 FEET
3 FEET
12 INCHES
6 FEET
7 FEET‡
12 INCHES††
16 INCHES
2 FEET†*
dwellings and serves both dwellings.
18 INCHES**
12 INCHES**
0 INCHES
0 INCHES***
2 INCHES***
3 FEET****
3 FEET****
9 INCHES
3 FEET†
7 FEET****
12 INCHES****
16 INCHES
2 FEET†*
a horizontal distance of 2 feet from the centerline of the terminal.
Clearance to unventilated soffit.
Clearance to an outside corner wall.
Clearance to an inside non-combustible corner wall or protruding
non-combustible obstructions (chimney, etc.).
Clearance to an inside combustible corner wall or protruding combustible obstructions ( vent chase, etc.).
Clearance to each side of the centerline extended above the meter
/ regulator assembly to a maximum vertical distance of 15ft.
Clearance to a service regulator vent outlet.
Clearance to a non-mechanical air supply inlet to the building or a
combustion air inlet to any other appliance.
Clearance to a mechanical air supply inlet.
Clearance above a paved sidewalk or paved driveway located on
public property unless fitted with a heat shield kit GD-301.
Clearance under a veranda, porch, deck or balcony.
Clearance above the roof.
Clearance from an adjacent wall including neighbouring buildings.
Page 9
INSTALLATION
WALL AND CEILING PROTECTION
For optimum performance, it is recommended that all horizontal runs have a minimum ¼ inch rise per foot using
For safe and proper operation of the stove, follow the venting instructions exactly.
HORIZONTAL INSTALLATIONVERTICAL INSTALLATION
This application occurs when venting through an exterior wall.
Having determined the air terminal location, cut and frame a hole
in an exterior wall with a minimum
square or round opening of 9".
(As an alternative to framing, a vent
pipe shield may be installed, ensuring a 1" clearance to
combustibles.)
1. Mark and cut the vent pipe
shield to the determined depth of the
combustible wall. Apply a bead of caulking (not supplied) to the framework or to the
shield plate (in the case of a finished wall) and secure the
shield through the opening to the interior wall. The final
location of the vent pipe shield should maintain the required clearance to the 7" vent pipe. Do not fill this cavity
with any type of material. Apply a bead of caulking all around
and place a firestop spacer over the vent shield to restrict
cold air from being drawn into the room or around the stove.
Ensure that both spacer and shield maintain the required
clearance to combustibles. Once the vent pipe is installed
in its final position, apply sealant between the pipe and the
firestop spacer.
FIGURE 10
OR
FIGURE 11
rigid venting.
This application occurs when venting through a roof. Installation kits for various roof pitches are available from
your Napoleon dealer. See Accessories to order the specific kit required.
1. Determine the air terminal location and
move the stove into position. Cut and frame 9
inch openings in the
ceiling and the roof to
provide the minimum 1
inch clearance between
the stove pipe and any
combustible material.
FIGURE 13
DO NOT FILL THIS SP ACE WITH ANY TYPE OF MA TERIAL.
A vent pipe shield will prevent any materials such as insu-
lation, from filling up the 1" air space around the pipe. Nail
headers between the joist for extra support.
2. Apply a bead of caulking (not supplied) to the framework or to the Wolf Steel vent pipe shield plate or equivalent (in the case of a finished ceiling), and secure over the
opening in the ceiling. A firestop must be placed on the
bottom of each framed opening in a roof or ceiling that the
venting system passes through. Apply a bead of caulking
all around and place a firestop spacer over the vent shield
to restrict cold air from being drawn into the room or around
the stove. Ensure that both spacer and shield maintain the
required clearance to combustibles. Once the vent pipe is
installed in its final position, apply sealant between the
pipe and the firestop spacer.
3. In the attic, after the pipe
has been installed, slide the
vent pipe collar down to cover
up the open end of the shield
and tighten. This will prevent
any materials, such as insulation, from filling up the 1" air
space around the pipe.
FIGURE 12
Try to centre the exhaust pipe location
midway between two
joist to prevent having to cut them. Use
a plumb bob to line
up the centre of the
openings.
FIGURE 14
9
W415-0100 / D / 01.13.04
Page 10
10
USING FLEXIBLE VENT COMPONENTS
Use only approved aluminum flexible liner kits marked:
"Wolf Steel Approved Venting" as
identified by the stamp only on the 7”
outer liner.
For safe and proper operation of the fireplace, follow
the venting instructions exactly.
* The vent system must be supported every 3 feet, for
both vertical and horizontal runs. Use Wolf Steel support
W010-0370 or equivalent non-combustible strapping to
maintain the 1" clearance from combustibles as well as to
prevent sagging.
HORIZONTAL AIR TERMINAL INSTALLATION
1. Stretch the 4" diameter aluminium flexible liner to the
required length taking into account the additional length
needed for the finished wall surface. Apply a heavy bead of
the high temperature sealant, supplied with the unit, to the
inside of the 4" liner approximately 1" from the end. Slip the
liner a minimum of 2" over the fireplace vent collar and
secure with 3 #8 screws.
2. Using the 7" diameter flexible aluminium liner, apply
sealant, slide a minimum of 2 " over the fireplace combustion air collar and secure with 3 #8 screws.
3. Insert the liners through the firestop. Position and
secure the fireplace using the nailing tabs (2 per side)
and/or secure to the floor using #10 hex head screws (not
supplied). The liners should be flush with the exterior wall.
The air terminal may be recessed into the exterior wall
or siding by ½", the depth of the return flange.
4. From outside, apply a bead of the high temperature
sealant to the inside of both liners, approximately 1" from
the end of each liner.
5. Holding the air terminal (lettering in an upright, readable position), insert into both liners with a twisting motion
to ensure that both the terminal sleeves engage into the
liners / sealant. Secure the terminal to the exterior wall and
make weather tight by sealing with caulking (not supplied).
FIGURE 15
6. If more than one length of liner needs to be used to
reach the fireplace, couple them together as illustrated.
Seal the joints using the same procedure as described in
points 2 and 3. The vent system must be supported every 3
feet, for both vertical and horizontal runs. Use Napoleon
support W010-0370 or equivalent noncombustible strapping to maintain the 1" clearance from combustibles as
well as to prevent sagging.
FIGURE 16
VERTICAL AIR TERMINAL INSTALLATION
1. Fasten the roof support
to the roof using the screws
provided. The roof support is
optional. The venting is to be
adequately supported using
either an alternate method
suitable to the authority having jurisdiction or the optional
roof support.
2. Stretch the 4" diameter aluminium flexible liner to the
required length. Slip the liner a minimum of 2" over the
inner sleeve of the air terminal and secure with 3 #8 screws.
Seal using a heavy bead of the high temperature sealant.
3. Repeat using the 7" diameter aluminium flexible liner.
4. Thread the air terminal pipe
assembly down through the roof.
The air terminal must be located
vertically and plumb. Attach the
air terminal assembly to the roof
support, ensuring that a
minimum 16" of air terminal will
penetrate the roof when
fastened.
DO NOT CLAMP THE FLEXIBLE ALUMINIUM LINER.
5. Remove nails from the shingles, above and to the
sides of the chimney. Place the flashing over the air terminal and slide it underneath the sides and upper edge of
the shingles. Ensure that the air terminal is properly centred within the flashing, giving a 3/4" margin all around.
Fasten to the roof. Do not nail through the lower portion of
the flashing. Make weather-tight by sealing with caulking.
FIGURE 17
FIGURE 18
* All horizontal runs must have a 1 inch rise per foot.
W415-0100 / D / 01.13.04
Page 11
Where possible, cover the sides and top edges of the flashing with roofing material.
6. Apply a heavy bead of
weatherproof caulking
2 inches above the flashing.
Slide the storm collar around
the air terminal and down to
the caulking. Tighten to ensure that a weather-tight seal
between the air terminal and
the collar is achieved.
Attach the other storm collar centred between the air intake
and the air exhaust slots onto the air terminal. Tighten
securely. Attach the vertical rain cap.
Spacers are attached to the 4" inner flex liner at predetermined intervals to maintain a 1-1/4" air gap to the 7"
outer liner. These sp acers must not be removed.
7. If more liner needs to be used to reach the fireplace,
follow the same procedure as found in HORIZONTAL AIRTERMINAL INST ALLA TION. The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel support ring assembly
W010-0370 or equivalent noncombustible strapping to
maintain the minimum 1" clearance to combustibles as
well as to prevent sagging.
FIGURE 19
11
RESTRICTING VERTICAL VENTS
Vertical installations running longer than 10 feet may display a very active flame. If this appearance is not desirable,
remove the brick baffle from the firebox, exposing the flue
gas outlet openings. Bend the restrictor plates up (from
their normal opening of 45°) into the flue openings. Replace the brick baffle. This reduces the velocity of the exhaust gases, slowing down the flame pattern and creating
a more traditional gentle appearance. Specific instructions
are shown in "Trouble Shooting".
FIGURE 20
FIREPLACE VENT CONNECTION
1. Install the 4 inch diameter aluminium flexible liner to
the fireplace. Secure with 3 screws and flat washers. Seal
the joint and screw holes using the high temperature sealant provided.
2. Install the 7 inch diameter aluminium flexible liner to
the fireplace. Attach and seal the joints.
FIGURE 21
W415-0100 / D / 01.13.04
Page 12
12
USING RIGID VENT COMPONENTS
For safe and proper operation of the fireplace, follow the venting instructions exactly.
For optimum performance, it is recommended that all horizontal runs have a minimum ¼ inch rise per foot
The vent system must be supported approximately every 3
feet for both vertical and horizontal runs. Use Wolf Steel
vent spacers W615-0033 every 3 feet and either side of
each elbow to maintain the minimum 1¼" clearance between the outer and inner vent pipes. Use Wolf Steel support ring assembly W010-0370 or equivalent noncombustible strapping to maintain the minimum 1" clearance to
combustibles for both vertical and horizontal runs.
HORIZONTAL AIR TERMINAL INSTALLATION
1. Move the fireplace into position. Measure the vent length
required between terminal and fireplace taking into account
the additional length needed for the finished wall surface
and any 1¼" overlaps between venting components.
2. Apply high temperature sealant to the outer edge of
the 4" inner collar of the fireplace. Attach the first vent
component and secure using 3 self tapping screws. Repeat using 7" piping.
3. Holding the air terminal (lettering in an upright, readable position), insert into both vent pipes with a twisting
motion to ensure that both the terminal sleeves engage into
the vent pipes and sealant. Secure the terminal to the exterior wall and make weather tight by sealing with caulking
(not supplied).
The air terminal may be recessed into the exterior
wall or siding by 1½", the depth of the return flange.
FIGURE 22
VERTICAL VENTING INSTALLATION
1. Attach 4" and 7" elbows to the stove. Apply high temperature sealant and secure the joints with 3 screws.
2. Move the fireplace into position.
3. Fasten the roof support to the roof using the screws
provided. The roof support is optional. The venting is to be
adequately supported using either an alternate method
suitable to the authority having jurisdiction or the optional
roof support.
4. Apply high temperature sealant to the outer edge of
the inner sleeve of the air terminal. Slip a 4" diameter coupler over the sleeve and secure using 3 screws.
using rigid venting.
5. Apply high temperature sealant to the outer edge of
the outside sleeve of the air terminal. Slip a 7" diameter
coupler over the sleeve and secure as before. Trim the 7"
coupler even with the 4" coupler end.
7. Remove nails from the shingles, above and to the
sides of the chimney. Place the flashing over the air terminal and slide it underneath the sides and upper edge of
the shingles. Ensure that the air terminal is properly centred within the flashing, giving a 3/4" margin all around.
Fasten to the roof. Do NOT nail through the lower portion of
the flashing. Make weather-tight by sealing with caulking.
Where possible, cover the sides and top edges of the flashing with roofing material.
8. Apply a heavy bead of waterproof caulking 2 inches
above the flashing. Slide the storm collar around the air
terminal and down to the caulking. Tighten to ensure that a
weather-tight seal between the air terminal and the collar
is achieved. Attach the other storm collar centred between
the air intake and air exhaust slots onto the air terminal.
Tighten securely. Attach the rain cap.
9. Continue adding rigid venting sections, sealing and
securing as above. Attach a 4" collapsed telescopic pipe to
the last section of rigid piping. Secure with screws and
seal. Repeat using a 7" telescopic pipe.
10. Run a bead of high temperature sealant around the
outside of the 4" elbow. Pull the adjustable pipe a minimum 2" onto the elbow. Secure with 3 screws. Repeat with
the 7" telescopic pipe.
11. In the attic, slide the vent pipe collar down to cover up
the open end of the shield and tighten. This will prevent
any materials, such as insulation, from filling up the 1" air
space around the pipe.
FIGURE 23
6. Thread the air terminal pipe
assembly down through the roof
support and attach, ensuring that
a minimum 16" of air terminal will
penetrate the roof when fastened. If the attic space is tight,
we recommend threading the
Wolf Steel vent pipe collar or
equivalent
terminal assembly as it is
passed through the attic. The air
terminal must be located
vertically and plumb.
loosely onto the air
W415-0100 / D / 01.13.04
Page 13
INSTALLATION / FRAMING
INSTALLATION
Proceed once the vent installation is complete.
Move the fireplace into position and secure using the nailing tabs (2 per side) and/or secure to the floor using #10
screws (not supplied).
FRAMING
It is best to frame your fireplace after it is positioned and the
vent system is installed. Use 2x4's and frame to local building codes. To install the fireplace face flush with the finished wall, position the framework to accommodate the
thickness of the finished wall. Pull out the four nailing tabs,
attached on either side of the fireplace and secure to the 2x4
framing to facilitate drywall installation.
FIGURE 24
13
Combustible materials may be installed flush with the front
of the fireplace but must not cover any of the black faceareas of the fireplace. Noncombustible material (brick,
stone or ceramic tile) may protrude in these areas.
It is not necessary to install a hearth extension with this
fireplace system.
When roughing in the fireplace, raise the fireplace to accommodate for the thickness of the finished floor materials, i.e. tile, carpeting, hard wood, which if not planned for
will interfere with the opening of the lower access door
and the installation of many decorative flashing accessories.
Objects placed in front of the fireplace should be kept a
minimum of 48" away from the front face.
MANTLE CLEARANCES & ENCLOSURES
Combustible mantle clearance
can vary according to the mantle depth. Use the graph to help
evaluate the clearance needed.
FIGURE 25
= 22" IF VENTING IS HORIZONTAL
A
= 27½" IF VENTING IS VERTICAL
FIGURE 26
Note: In order to avoid the possibility of exposed insulation
or vapour barrier coming in contact with the fireplace body, it
is recommended that the walls of the fireplace enclosure be
“finished” (ie: drywall/sheetrock), as you would finish any
other outside wall of a home. This will ensure that clearance
to combustibles is maintained within the cavity.
FIGURE 27
FIGURES 28
1" clearance to combustibles from the vent pipe
must be maintained .
The U-channel may be removed if framing is faced with a
noncombustible material (cement board) (not supplied).
These same mantle clearance requirements apply to
any combustibles protruding on either side of the
fireplace.
MOBILE HOME INSTALLATION
The fireplace is equipped with two 1/4" diameter holes
located in the front left and right corners of the base. For
mobile home installations, the fireplace must be fastened
in place. Use #10 screws, inserted through the holes in
the base to secure. It is recommended that the fireplace
be secured in all installations.
In Canada, mobile home installation may be vented horizontally or vertically. In the United States, it may only be
installed vertically. See "Vertical Venting" or "Horizontal Air
Terminal Installation" for installation.
W415-0100 / D / 01.13.04
Page 14
14
GAS INSTALLATION
1. Route a 3/8" N.P.T. black iron gas line, 1/2" type-L
copper tubing or equivalent to the fireplace.
2. For ease of accessibility, an optional remote wall
switch or millivolt thermostat may be installed in a convenient location. Route double strand solid core millivolt wire
through the electrical hole located at the bottom left side of
the unit. The recommended maximum lead length depends on wire size:
3. Attach the two leads to terminals 1 and 3 located on
the gas valve.
Do not connect either the wall switch, thermostat or gas
valve to electricity (110 volts).
FIGURE 29
4. Install rigid black pipe, 1/2" type-L copper tubing or, if
local codes permit, a 3/8" flex connector and shutoff valve
to the gas line and the fireplace gas valve. Seal and tighten
securely. An adapter fitting is required between the gas
valve and the copper tubing or flex connector.
Do not kDo not k
Do not k
Do not kDo not k
FIGURE 30
Purge all gas lines with the glass door of the fireplace
open. Assure that a continuous gas flow is at the burner
before closing the door.
5. Check for gas leaks by brushing on a soap and water
solution.
Do not use open flame.
ink fink f
ink f
ink fink f
lele
le
lele
x connectorx connector
x connector
x connectorx connector
..
.
..
FINISHING
BRICK PANEL INSTALLATION
1. Remove the two brick retainers located on either of the
firebox sides as illustrated.
2. Remove the protective plastic wrap from all four panels. Centre the rear brick panel against the back of the
firebox.
3. Tilt and insert the left brick panel against the left side
of the firebox, ensuring that it butts up to the rear panel.
Excess material may be trimmed with a utility knife. Secure
in place using a retainer bracket and 2 of the screws. Repeat for the right side.
4. Slide the upper brick baffle into place over the side
brick panels.
When shipped, the brick panels range in colour from
white to varying shades of brown. During initial use,
the panels will darken temporarily and emit a slight
odour for a few hours. This is a normal condition that
will not occur again. Simply open a window to sufficiently ventilate the room. The appearance of the panels will permanently lighten in colour with use.
FIGURE 31
W415-0100 / D / 01.13.04
Page 15
LOG PLACEMENT
PHAZERTM logs, exclusive to Napoleon Fireplaces, pro-
vide a unique and realistic glowing effect that is different in
every installation. Use only certified PHAZERTM logs available from your Napoleon / Wolf Steel Ltd. dealer.
POSITIONING THE LOGS IMPROP-
ERLY WILL CAUSE FLAME IMPINGE-
MENT AND CARBONING.
Position the logs as shown. All logs are numbered.
FIGURE 32a
15
FIGURE 32c
Log (#6) has a leg that fits into an indentation on the top of
log (#3).
FIGURE 32d
The rear log should be centred on the log support.
FIGURE 32b
Logs (#2) and (#3) have one leg on each underside that fits
into the rectangular cutouts on the burner securing plate.
Logs (#5) and (#7) fit onto the indentations of the lower
logs.
W415-0100 / D / 01.13.04
Page 16
16
L45 LOUVRE INSTALLATION
FIGURE 34a-c
A
B
FIGURE 33
DOOR OPENING
(To open the door, the trim must be removed.) When
opening the fire viewing door, a simple procedure must be
followed in order to not damage the door. First open the
valve control door. Next remove the louvres
located above the door. The door is secured by two latches at the top and an-
other two at the bottom. Pull the latch handles towards you and release each catch. The door may
now be safely opened.
To close the door, repeat in reverse order.
DOOR REMOVAL
To remove the door, fully open to 90°, lift up and off.
TRIM INSTALLATION
The 2 vertical trim pieces are each held on with two magnets. Attach the trim to the magnets.
GDL45 LOUVRE INSTALLATION
The louvre assemblies are installed as illustrated in figure
33. In addition, the louvre hood, located above the upper
louvres, is held in place with 4 clips. Slide the short leg of
the louvre hood into the clips, as shown.
C
A
CLIPS
HOOD
Attach the hood by pressing
the top flange into the clips
along the top of the louvre
FLANGE
opening. Secure using two
screws located through the
SLOT
slots.
UPPER LOUVRES
SLOT
Insert the louvre tabs into the
slots located at the top left
and right corners of the unit.
TAB
B
W415-0100 / D / 01.13.04
C
HINGE
CLIP
SLOT
LOWER LOUVRES
Insert the hinge clips into the
slots located at the bottom left
and right corners of the unit.
To remove the louvres, pull
the back tabs of the clips
forward, while pushing the
louvre assembly back. Lift the
clip.
Page 17
OPTIONAL BLOWER INSTALLATION
INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grounded
in accordance with local codes. In the absence of local
codes, use the current CSA C22.1 CANADIANELECTRICALCODE
in Canada or the ANSI/NFPA 70 NATIONALELECTRICALCODE in the
United States.
FIGURE 35
The three slots on the
blower mounting
bracket allow ease of
adjustment when
attaching the blower.
For a quiet running
blower, do not allow the
assembly to sit on the
firebox base.
Slide the vibration reducing pad
(A) into the clip (C) and up against
the threaded stud (B) at the other
end. The blower must be able to
be positioned entirely onto the
pad.
Tilt the blower onto its
side. Slide it past the
controls and into the
clip (C). Secure to the
threaded stud using
the lock washer and
wing nut provided. Ensure that the blower
does not touch the fireplace base or the firebox.
FIGURE 36
B
A
FIGURE 37
C
FIGURE 38
17
Attach the connectors from the black and white wires to the
thermodisc and secure the thermodisc bracket to the securing stud at the bottom left of the unit using a lock washer
and wing nut. Ensure that the thermodisc touches the firebox wall.
Attach the connectors from the black and red wires to the
blower.
Attach and secure the variable speed switch using the nut
provided. Plug the harness cord into the receptacle.
FIGURE 39
FIGURE 40
The wire harness provided in this kit is a universal
harness. When installed, ensure that any excess
wire is contained, preventing it from making contact with moving or hot objects.
Because the blower is thermally activated, when
turned on, it will automatically start approximately
10 minutes after lighting the fireplace and will run
for approximately 30-45 minutes after the fireplace
has been turned off. Use of the fan increases the
output of heat.
Drywall dust will penetrate into the blower bearings causing irreparable damage and must be prevented from coming into contact with the blower
or its compartment. Any damage resulting from
this condition is not covered by the warranty
policy.
W415-0100 / D / 01.13.04
Page 18
18
OPTIONAL FAN INSTALLATION
ELECTRICAL INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be connected and grounded
in accordance with local codes. In the absence of local
codes, use the current CSA C22.1 CANADIANELECTRICALCODE
in Canada or the ANSI/NFP A 70 NATIONALELECTRICALCODE in
the United States.
To safely install the fan, turn off the electricity first.
FIGURE 41
If the fireplace was not previously equipped with a fan:
route a grounded 2-wire, 60hz power cable to the junction
box. At this point, it must be strain relieved and insulated.
The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained, preventing it from making contact with moving or
hot objects.
To ease installation of the fan, remove the hinge screen
and valve control door (lower louvres) from the base of the
fireplace.
Position the vibration reducing pad into the clip and onto
the threaded stud at the other end, piercing a hole into the
pad. The fan assembly must be able to be positioned entirely onto the pad.
Slide the fan assembly past the controls and into the clip.
Secure using the lock washer and nut provided.
Plug the harness cord into the receptacle.
GD36 THERMOSTATIC SENSOR CONTROL
This optional kit is meant to be used only in conjunction
with the GD65 Fan Kit, shown above, which may be ordered from your Wolf Steel / Napoleon dealer.
With the thermostatic sensor option, the fan, when turned
on, becomes thermally activated, and will automatically
run approximately 15-30 minutes after the fireplace has
been lit and for approximately 30-45 minutes after the fireplace has been turned off.
FIGURE 42
Use of the fan increases the output of heat.
Unplug the power cord from the receptacle. Connect all
wires as shown.
Attach and secure the sensor assembly bracket to the se-
curing stud located next to the receptacle/junction box at
the bottom left of the unit using the lock washer and wing
nut. Ensure that the thermodisc touches the firebox wall.
Plug the power cord back into the receptacle.
When installed, ensure that any excess wire is contained,
preventing it from making contact with moving or hot objects.
FIGURE 43
W415-0100 / D / 01.13.04
Page 19
OPERATION / MAINTENANCE
19
OPERATING INSTRUCTIONS
When lit for the first time, the fireplace will emit a slight
odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of
internal paints and lubricants used in the manufacturing
process and will not occur again. Simply open a window to
sufficiently ventilate the room.
FOR YOUR SAFETY READ BEFORE LIGHTING:
A. This fireplace is equipped with a pilot which must be lit by
hand while following these instructions exactly.
B. Before operating smell all around the fireplace area for
gas and next to the floor because some gas is heavier
than air and will settle on the floor.
C. Use only your hand to turn the gas control knob. Never
use tools. If the knob will not turn by hand, do not try to
repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under water .
Immediately call a qualified service technician to inspect
the fireplace and replace any part of the control system
and any gas control which has been under water.
After extended periods of non-operation such as following
a vacation or a warm weather season, the fireplace may
emit a slight odour for a few hours. This is caused by dust
particles in the heat exchanger burning off. Open a window
to sufficiently ventilate the room.
Purge the gas line with the glass door open. assure that
a continuous gas flow is at the burner before closing
the door. Allow several minutes (5-15) for the flame to
stabilize after ignition.
WHAT TO DO IF YOU SMELL GAS
• Turn off all gas to the fireplace.
• Open windows.
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
GAS KNOB
LIGHTING INSTRUCTIONS
WARNING: The gas valve has an interlock device which
will not allow the pilot burner to be lit until the thermocouple has cooled. Allow approximately 60 seconds for the
thermocouple to cool.
When lighting and relighting, the gas knob cannot be turned
from pilot to off unless the knob is depressed slightly.
1. Stop! Read the above safety information on this label.
2. Turn off all electric power to the fireplace.
3. Turn the gas knob clockwise to off.
4. Wait five (5) minutes to clear out any gas. If you smell
gas including near the floor. S top! Follow "B" in the above
safety information on this label. If you don't smell gas go
the next step.
TO TURN OFF GAS
1. Turn off all electric power to the fireplace if service is to
be performed.
2. For a complete shutdown procedure: push in gas control knob slightly and turn clockwise to off. Do not force.
5. Turn gas knob counter-clockwise to pilot.
6. Depress slightly and hold gas knob while lighting the
pilot with the push button igniter. Keep knob depressed
for one minute, then release. If pilot does not continue to
burn, repeat steps 3 through 5.
7. With pilot lit, depress and turn gas knob counter-clockwise to on.
8. If equipped with remote on-off switch/thermostat, main
burner may not come on when you turn valve to on.
Remote switch must be in the on position to ignite burner.
9. Turn on all electric power to the fireplace.
3. For a temporary showdown procedure: set thermostat
to lowest setting or remote switch to off. Press and turn
the gas knob clockwise to pilot.
W415-0100 / D / 01.13.04
Page 20
20
Turn off the gas and electrical power before servicing
the fireplace.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
This fireplace and its venting system should be inspected
before use and at least annually by a qualified service person. The fireplace area must be kept clear and free of
combustible materials, gasoline or other flammable vapours and liquids. The flow of combustion and ventilation
air must not be obstructed.
1. In order to properly clean the burner and pilot assembly , remove the logs to expose both assemblies.
2. Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by
vacuuming or brushing, at least once a year.
MAINTENANCE
3. Check to see that all burner ports are burning. Clean
out any of the ports which may not be burning or are not
burning properly .
4. Check to see that the pilot flame is large enough to
engulf the thermocouple and thermopile and reaches
toward the burner with the third jet.
5. Replace the cleaned logs.
6. Check to see that the main burner ignites completely
on all openings when the gas knob for the burner is
turned on. A 5 to 10 second total light-up period is satisfactory . If ignition takes longer , consult your Napoleon
dealer / distributor.
7. Check that the gasketing on the door is not broken or
missing. Replace if necessary .
ADJUSTMENTS
PILOT BURNER ADJUSTMENTVENTURI ADJUSTMENT
Adjust the pilot screw to provide properly sized flame. Turn
in a clockwise direction to reduce the gas flow.
FIGURE 44
FIGURE 45
Natural gas models have air shutters set at ¼ (.250") inch
open. Propane gas models have air shutters set at 3/8
(.375) inch open. Closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air
shutter will cause a more blue flame, but can cause flame
lifting from the burner ports. The flame may not appear
yellow immediately; allow 15 to 30 minutes for the final
flame colour to be established.
FIGURE 46
AIR SHUTTER ADJUSTMENT MUST ONL Y BE DONE BY A
QUALIFIED GAS INST ALLER!
W415-0100 / D / 01.13.04
Page 21
REPLACEMENTS
Contact your dealer for questions concerning prices and
availability of replacement parts. Normally all parts can be
ordered through your Napoleon dealer or distributor.
When ordering replacement parts always give the following information:
ODEL & SERIAL NUMBEROFFIREPLACE
1. M
2. INSTALLATIONDATEOFFIREPLACE
3. PART NUMBER
4. DESCRIPTIONOFPART
5. FINISH
21
FORFOR
WARRANTYWARRANTY
FOR
WARRANTY
FORFOR
WARRANTYWARRANTY
ORIGINALORIGINAL
ORIGINAL
ORIGINALORIGINAL
INVOICEINVOICE
INVOICE
INVOICEINVOICE
REPLREPL
REPL
REPLREPL
WILLWILL
WILL
WILLWILL
AA
CEMENTCEMENT
A
CEMENT
AA
CEMENTCEMENT
BEBE
BE
BEBE
PP
ARAR
P
AR
PP
ARAR
REQUIREDREQUIRED
REQUIRED
REQUIREDREQUIRED
TSTS
TS
TSTS
, ,
,
, ,
TOTO
TO
TOTO
AA
A
AA
PHOPHO
TT
OCOPYOCOPY
PHO
T
OCOPY
PHOPHO
TT
OCOPYOCOPY
HONOURHONOUR
HONOUR
HONOURHONOUR
THETHE
THE
THETHE
OFOF
OF
OFOF
REPLACEMENT PARTS
#PART NO. DESCRIPTION
1GL-618LOG SET COMPLETE
2W135-0097EMBER/FRONT BRICK (#8L)
3W135-0098EMBER/FRONT BRICK (#8R)
4W135-0030LOG # 1
5W135-0031LOG # 2
6W135-0032LOG # 3
7W135-0033LOG # 4
8W135-0034LOG # 5
9W135-0035LOG # 6
10W135-0036LOG # 7
11* W390-0001LATCH
12* W715-0196TRIM
13W010-0933DOOR c/w GLASS
14W010-0464GLASS c/w GASKET
15* W562-0024DOOR GASKET (120")
16* W225-0050BLACK DOOR FRAME
17GD-784KTBRICK PANEL KIT
18W475-0168REAR BRICK PANEL
19W475-0166RIGHT SIDE BRICK PANEL
20W475-0167LEFT SIDE BRICK PANEL
21W475-0165BRICK BAFFLE
22* W160-0032LOUVRE HOOD CLIP
23* W573-0008HIGH TEMPERATURE SEALANT - 3 OZ
24* W430-0001CERAMIC MAGNET
25* W385-0245NAPOLEON LOGO
26W725-0025NATURAL GAS V ALVE
26W725-0026PROPANE GAS V AL VE
27W100-0050BURNER
28W455-0067#30 BURNER ORIFICE - NG
28W455-0041#49 BURNER ORIFICE - LP
29* W660-0042BURNER ON/OFF SWITCH
30W357-0001PIEZO IGNITER
31W455-0067NATURAL GAS PILOT INJECTOR
31W455-0069PROPANE GAS PILOT INJECTOR
32W010-0794NATURAL GAS PILOT ASSEMBL Y
32W010-0795PROPANE GAS PILOT ASSEMBLY
33W680-0005THERMOCOUPLE
34W680-0004THERMOPILE
ROOF TERMINAL KITS
35* 1/12 TO 7/12 PITCH-GD-110
36* 8/12 TO 12/12 PITCH-GD-111
37* FLAT ROOF-GD-112
38W010-0569AIR TERMINAL
39W120-0036VERTICAL CAP
40W170-0063STORM COLLAR
41W010-0567ROOF SUPPORT
42W263-0054 / W263-0055 / W263-0056ROOF FLASHING
50W500-0096FIRE STOP - FLEXIBLE VENTING
50W500-0136FIRE STOP - RIGID VENTING
51* W010-0370WALL SUPPORT ASSEMBL Y
52* W175-00137" COUPLER
53* W175-00014" COUPLER
54* W573-0008HI-TEMP SEALANT 3 OZ
55* W660-0013MODULATING REMOTE
56* GD825NMODULATING VALVE REGULAT OR FOR W660-0013 - NG
56* GD825PMODULA TING VALVE REGULAT OR FOR W660-0013 - P
57* W660-0011BREMOTE CONTROL - ADVANTAGEPLUS
58KB35VARIABLE SPEED SWITCH
59* W500-0033V.S.S. MOUNTING PLATE for wall switch
60* W690-0001MILLIVOLT THERMOSTA T
61GZ550-1KTBLOWER KIT
62* GD65FAN KIT
63* GD36
64GDL45KBLACK LOUVRE KIT
64GDL45PBPOLISHED BRASS LOUVRE KIT
64GDL45SSSTAINLESS STEEL LOUVRE KIT
65L45KBLACK LOUVRE KIT
65L45PBPOLISHED BRASS LOUVRE KIT
65L45SSSTAINLESS STEEL LOUVRE KIT
66GA-566HOT AIR DISTRIBUTION KIT
67* W690-0005THERMOSTAT 110V FORUSEWITH GA-566
68GA - 72HOT AIR EXHAUST KIT
69GA-70EXTENSION KIT 5 FT
70* W175-0053DURA-VENT ZERO CLEARANCE ADAPTOR
71W585-0072VENT PIPE SHIELD
72W585-0071VENT PIPE COLLAR
73* W175-0069CONVERSION KIT - NG - LP
73* W175-0068CONVERSION KIT - LP - NG
THERMOSTATIC SENSOR CONTROL KIT
FOR USE WITH GD
65
ONLY
W415-0100 / D / 01.13.04
Page 22
22
W415-0100 / D / 01.13.04
* WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with
a fast acting thermocouple supplied by Wolf Steel Ltd.
Page 23
TROUBLE SHOOTING GUIDE
B
EFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED
SYMPTOMPROBLEMTEST SOLUTION
23
.
Pilot goes out when
the gas knob is released.
The gas valve has an
interlock device
which will not allow
the pilot burner to be
lit until the thermocouple has cooled.
Allow approximately
60 seconds for the
thermocouple to cool.
Pilot will not light.- check if pilot can be lit by a match
Pilot burning; no gas
to main burner; gas
knob is on 'HI'; wall
switch / thermostat is
on.
Pilot goes out while
standing; Main burner
is in 'OFF' position.
Main burner goes out;
pilot stays on.
System is not correctly purged.
Out of propane gas.- fill the tank.
Pilot flame is not large enough- turn up the pilot flame.
Pilot flame is not engulfing the
thermocouple.
Thermocouple shorting / faulty.- loosen and tighten thermocouple.
Faulty valve.
No spark at pilot burner
Spark gap is incorrect- spark gap should be 0.150" to 0.175" (5/32" to 11/64"
No gas at the pilot burner
Themostat or switch is defective.
Wall switch wiring is defective.
Main burner orifice is plugged.- remove stoppage in orifice.
Faulty valve.
Gas piping is undersized.- turn on all gas appliances and see if pilot flame flutters,
Pilot flame is not large enough or
not engulfing the thermopile
Thermopile shorting
Remote wall switch wire is too
long; too much resistance in the
system.
Faulty thermostat or switch.
- purge the gas line with the glass door open.
- gently twist the pilot head to improve the flame pattern
around the thermocouple.
- clean thermocouple and valve connection.
- replace thermocouple.
- replace valve.
- replace.
- check that the wire is connected to the push button ignitor.
- check if the push button ignitor needs tightening.
- replace the wire if the wire insulation is broken or frayed.
- replace electrode if ceramic insulator is cracked or broken.
- replace the push button ignitor.
- fill the tank.Out of propane gas
approx.) from the electrode tip and the pilot burner. To ensure proper electrode location, tighten securing nut (finger
tight plus 1/4 turn).
- check that the manual valve is turned on.
- check the pilot orifice for blockage.
- replace the valve.
- call the gas distributor.
- connect a jumper wire across the wall switch terminals; if
main burner lights, replace switch / thermostat.
- disconnect the switch wires & connect a jumper wire across
terminals 1 & 3; if the main burner lights, check the wires for
defects and / or replace wires.
- replace.
diminishes or extinguishes, especially when main burner
ignites. Monitor appliance supply working pressure.
- check if supply piping size is to code. Correct all undersized piping.
- turn up pilot flame.
- replace pilot assembly.
- clean thermopile connection to the valve. Reconnect.
- replace thermopile / valve.
- shorten wire to correct length or wire gauge.
- replace.
W415-0100 / D / 01.13.04
Page 24
24
SYMPTOMPROBLEMTEST SOLUTION
Main burner goes
out; pilot goes out.
Main burner
flame is a blue,
lazy, transparent
flame.
Flames are very
active.
Flames are consistently too large
or too small.
Carboning occurs.
Carbon is being
deposited on
glass, logs or
combustion
chamber surfaces.
White / grey film
forms.
Exhaust fumes
smelled in room,
headaches.
Remote wall
switch is in "OFF"
position; main
burner comes on
when gas knob is
turned to "ON" position.
W415-0100 / D / 01.13.04
Refer to "MAIN BURNER GOES OUT ; PILOT ST A YS ON"
Vent is blocked
Vent is re-circulating
4" flexible vent has become
disconnected from fireplace.
Blockage in vent.- remove blockage. In really cold conditions, ice buildup may occur
Incorrect installation.
Aggressive venting action due
to vent height.
Unit is over-fired or under-fired.
Air shutter has become
blocked
Flame is impinging on the
logs or combustion chamber.
Sulphur from fuel is being deposited on glass, logs or combustion chamber surfaces.
Fireplace is spilling.
Wall switch is mounted upside
down
Remote wall switch is grounding.
Remote wall switch wire is
grounding.
Faulty valve.
- check for vent blockage.
- check joint seals and installation.
- re-attach to fireplace.
on the terminal and should be removed as required.
- refer to Figure 16 to ensure correct location of storm collars.
- Restrict vent exit. See "RESTICTING VERTICAL VENTS".
- VENT HEIGHT LESS THAN 10 FEET: close air shutter slightly to
reduce primary air.
- VENT HEIGHT 10 TO 20 FEET: close restrictor plate by 2/3 (to 30°
open) from the normal factory setting.
- VENT HEIGHT MORE THAN 20 FEET: close restrictor plate completely from normal factory setting.
- check pressure readings:
Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the
test point. Gauge should read 7" (minimum 4.5") water column for
natural gas or 13" (11" minimum) water column for propane. Check
that main burner is operating on "HI".
Outlet pressure can be checked the same as above using screw
(B). Gauge should read 3.5" water column for natural gas or 10"
water column for propane. Check that main burner is operating on
"HI".
AFTER TAKING PRESSURE READINGS, BE SURE TO TURN
SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT
OVERTORQUE.
Leak test with a soap and water solution.
- ensure air shutter opening is free of lint or other obstructions.
- check that the logs are correctly positioned.
- open air shutter to increase the primary air.
- check the input rate: check the manifold pressure and orifice size
as specified by the rating plate values.
- check that the door gasketing is not broken or missing and that
the seal is tight.
- check that both 4" and 7" vent liners are free of holes and well
sealed at all joints.
- check that minimum rise per foor has been adhered to for any
horizontal venting.
- clean the glass with a recommended gas fireplace glass cleaner.
DO NOT CLEAN GLASS WHEN HOT.
If deposits are not cleaned off regularly, the glass may become
permanently marked.
- check door seal and relief flap seal.
- check for chimney blockage
- check that chimney is installed to building code.
- room is in negative pressure; increase fresh air supply.
- reverse.
- replace.
- check for ground (short); repair ground or replace wire.
- replace.