Napoleon Fireplaces BGNV42P, BGNV42N User Manual

Page 1
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.22, AND ANSI Z21.50 RESPECTIVELY FOR VENTED GAS FIREPLACES.
MILLIVOLT SYSTEM
1
INSTALLATION AND OPERATION INSTRUCTIONS FOR
VENTED GAS FIREPLACE
NATURAL GAS MODEL
PROPANE GAS MODEL
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS
BGNV42N
BGNV42P
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapours and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.
•If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
R-2000
W415-0377 / C / 09.23.05
Page 2
2
PG 2-4
INTR
ODUCTION
PG10OPTION
AL BL
O
WER INST
ALLA
TION
WARNING
TABLE of CONTENTS
Warranty General Instructions General Information Care of Glass & Plated Parts
5 VENTING
Vent Safety Switch Hi Limit Switch Venting Action Check
6-7 INSTALLATION
Gas Installation Framing Nailing Tab Installation Mantle Clearances
8-9 FINISHING
Louvre Bracket Installation Door Removal & Installation Louvre Installation Logo Placement Log Placement Charcoal & Glowing Embers
11 OPTIONAL FAN INSTALLATION
OPTIONAL THERMOSTATIC SENSOR
12-13 OPERATION / MAINTENANCE
Operating Instructions Maintenance
13 ADJUSTMENTS
Pilot Burner Adjustment Venturi Adjustment
14 REPLACEMENTS
Ordering Replacement Parts Replacement Parts Accessories
15-16 TROUBLE SHOOTING GUIDE
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
The product is a vented gas fireplace. Do not burn wood or other materials in this fireplace.
• Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the fireplace.
• Due to high temperatures, the fireplace should be located out of traffic and away from furniture and draperies.
• Clothing or other flammable material should not be placed on or near the fireplace.
• Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace.
• It is imperative that the control compartments, burners and circulating blower and its passageway in the fire­place and venting system are kept clean. The fireplace and its venting system should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The fireplace area must be kept clear and free from combustible materi­als, gasoline and other flammable vapours and liquids.
• Under no circumstances should this fireplace be modified.
• This fireplace must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.
• Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.
• Do not operate the fireplace with the glass door removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. Use only with a glass door certified with the fireplace.
• Do not strike or slam shut the fireplace glass door.
W415-0377 / C / 09.23.05
Page 3
NAPOLEON products are manufactured under the strict Standard of the world recognized
ISO 9001 : 2000 Quality Assurance Certificate.
NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you, the cus­tomer, receives the quality product that you expect from NAPOLEON.
NAPOLEON GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY
The following materials and workmanship in your new NAPOLEON gas fireplace are warranted against defects for as long as you own the fireplace. This covers: combustion chamber, heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled components and aluminum extrusion trims.
Electrical (110V and millivolt) components and wearable parts such as the blower, gas valve, thermal switch, switches, wiring, remote control, ignitor, gasketing, and pilot assembly are covered and NAPOLEON will provide replacement parts free of charge during the first year of the limited warranty.
Labour related to warranty repair is covered free of charge during the first year. Repair work, however, requires the prior approval of an authorized company official. Labour costs to the account of NAPOLEON are based on a predetermined rate schedule and any repair work must be done through an authorized NAPOLEON dealer.
3
CONDITIONS AND LIMITATIONS
NAPOLEON warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears on the warranty registration card filed with NAPOLEON -- provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following conditions and limitations:
This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.
The gas fireplace must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes.
This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel parts, mechanical breakage of PHAZER™ logs and embers, nor any venting components used in the installation of the fireplace.
NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During the first 10 years NAPO­LEON will replace or repair the defective parts at our option free of charge. From 10 years to life, NAPOLEON will provide replacement burners at 50% of the current retail price.
In the first year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions.
After the first year, with respect to this President's Limited Lifetime Warranty, NAPOLEON may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).
After the first year, NAPOLEON will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not covered by this warranty.
Notwithstanding any provisions contained in this President's Limited Lifetime Warranty, NAPOLEON’S responsibility under this warranty is defined as above and it shall not in any event extend to any incidental, consequential or indirect damages.
This warranty defines the obligations and liability of NAPOLEON with respect to the NAPOLEON gas fireplace and any other warranties expressed or implied with respect to this product, its components or accessories are excluded.
NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. NAPOLEON will not be responsible for: over-firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventila­tion, excessive venting configurations, insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
Any damages to fireplace, combustion chamber, heat exchanger, brass trim or other component due to water, weather damage, long periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON.
The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration card must be returned within fourteen days to register the warranty.
NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.
ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD.
W415-0377 / C / 09.23.05
Page 4
4
GENERAL INSTRUCTIONS
THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with
local codes. Installation practices vary from region to re­gion and it is important to know the specifics that apply to your area, for example: in Massachusetts State:
•The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert or gas log.
•The appliance off valve must be a “T” handle gas cock.
•The flexible connector must not be longer than 36 inches.
•The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion
product.
•WARNING: This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of
Massachusetts.
In absence of local codes, install the fireplace to the cur­rent National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes.
The fireplace and its individual shut off valve must be dis­connected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The fireplace must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
When the fireplace is installed directly on carpeting, vinyl tile or other combustible material other than wood flooring, the fireplace shall be installed on a metal or wood panel extending the full width and depth.
If the optional fan or blower is installed, the junction box must be electrically connected and grounded in accord­ance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
CARE OF GLASS, AND PLATED PARTS
Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. The fireplace is factory equipped with 3/16" thick tempered glass. Use only replace­ment glass available from your Napoleon dealer.
Do not substitute materials.
Clean the glass after the first 10 hours of operation with a recommended gas fireplace glass cleaner. Thereafter clean as required.
Do not clean glass when hot!
If the glass is not kept clean permanent discolouration and / or blemishes may result.
Use only accessories designed for and
listed with your specific fireplace.
Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for serv­icing and operating the fireplace. Never obstruct the front opening of the fireplace.
Objects placed in front of the fireplace must be kept a minimum of 48" away from the front face of the unit.
For safe and proper operation of the fireplace fol­low the venting & operating instructions exactly.
Provide a means for visually checking the vent con­nection to the fireplace after the fireplace is in­stalled.
In order to avoid the possibility of exposed insula­tion and vapour barrier coming into contact with the fireplace body, it is recommended that the walls of the fireplace enclosure be 'finished' (i.e.: drywall/ sheetrock) as you would finish any other wall of the home. This will ensure that clearance to combustibles is maintained within the cavity.
GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUAL­ITY! Maximum input for the fireplace is 28,500 BTU/h for
natural gas and propane. When the fireplace is installed at elevations above 4,500ft, and in the absence of specific recommendations from the local authority having jurisdic­tion, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft.
Minimum inlet gas supply pressure is 4.5 inches water col­umn for natural gas and 11 inches water column for pro­pane. Maximum inlet gas pressure is 7 inches water col­umn for natural gas and 13 inches water column for pro­pane. Manifold pressure under flow conditions is 3.5 inches water column for natural gas and 10 inches water column for propane.
This fireplace is approved for bedroom and bed-sitting room installation.
No external electricity (110 volts or 24 volts) is required
for the gas system operation. Expansion / contraction
noises during heating up and cooling down cycles are nor­mal and are to be expected.
W415-0377 / C / 09.23.05
FIGURE 1
Page 5
VENTING
5
This is a vented appliance and must be connected to a chimney in accordance with the current installation codes. In absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes. This model can be common-vented.
A minimum six inch diameter (6"ø) B-vent or class A vent is required. A minimum 10' vent height is required. Secure the B-vent to the exhaust collar on the stove top with 3 screws. In cold climates, the use of a B-vent and an insu-
VENT SAFETY SWITCH
lated chase is recommended. This thermally activated switch, located in front of the draft
hood, senses an increase in temperature and acts as a safety shut-off (See 'A' below). It shuts down the gas to the main burner in the event of a severe downdraft of air or a blocked or disconnected chimney flue. If the flue is blocked or has no "draw", the safety switch will automatically shut off the supply of gas to the main burner within 10 minutes.
This switch must be manually reset by depressing the plunger. Refer to Figure 2.
Tampering with the safety switch can result in car­bon monoxide poisoning and possible death.
HIGH LIMIT SWITCH
This thermally activated switch, located in front of the draft hood, senses an increase in temperature and acts as a safety shut-off (See 'A' below). It shuts down the gas to the main burner in the unlikely event of the unit overheating. The HI Limit switch will automatically reset after the unit
VENT SAFETY
has cooled down, resuming gas flow to the main burner.
SWITCH
THERMOSTAT OR WALL SWITCH
FIGURE 3
HIGH LIMIT SWITCH
VALVE
VENTING ACTION CHECK
A test for correct venting action must be made before the installed unit can be left with the customer.
Follow the procedure below:
1. Close all doors and windows in the room / start ex­haust fans in the home / turn the fireplace blower off (if so equipped).
2. Set controls to "high" and light the unit.
3. Wait 5 minutes. Light a match and hold to the front of the draft hood. FIGURES 4 & 5.
FIGURE 2
PLUNGER
A
TP
B
1 2
3
HI LIMIT SWITCH
FIGURE 4
Venting action is satisfactory, if smoke and flames are drawn into the draft hood.
FIGURE 5
Venting action is unsatisfactory, if the smoke spills back, and the flame splays outward. If venting action is unsatisfac­tory, turn off the unit, wait 10 minutes and try again. If the smoke is still not drawn into the draft hood, turn the unit off and check for vent blockage or restriction. If necessary, consult with a quali­fied inspector.
The Vent Safety or Hi Limit switches must not be adjusted or disabled.
In the event that either switch or any associated parts are exchanged, only original manufacturer's parts may be used.
W415-0377 / C / 09.23.05
Page 6
6
INSTALLATION
GAS INSTALLATION
Proceed once the vent installation is complete.
1. Move the fireplace into position and secure using the
nailing tabs and/or secure to the floor through the 1/4"ø holes located at either end of the base.
2. Route a 3/8" N.P.T. black iron gas line, 1/2" type-L
copper tubing or equivalent to the fireplace.
3. For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient lo­cation. Route 2-strand (solid core) millivolt wire through the electrical hole located at the bottom left side of the unit. The recommended maximum lead length depends on wire size:
WIRE SIZE MAX. LENGTH
14gauge 100 feet 16gauge 60 feet
18gauge 40 feet Attach the one lead to terminal 3 (located on the gas valve) and the other lead to the vent safety switch wire ( located loose in the valve compartment). See FIGURE 3.
Do not connect either the wall switch, thermostat or gas valve to electricity (110 volts).
FIGURE 6
1
2
3
L
O
F
I
H
P
I
L
O
T
O
F
N
O
P
L
T
I
O
FRAMING
It is best to frame your fireplace after it is positioned. Use 2x4's and frame to local building codes. FIGURE 7-9.
Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fireplace body, it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home. This will ensure theat clearance to combustibles is maintained within the cavity.
It is not necessary to install a hearth extension with this fireplace system.
When roughing in the fireplace, raise the fireplace to ac­commodate for the thickness of the finished floor materi­als, i.e. tile, carpeting, hard wood, which if not planned for will interfere with the opening of the lower access door and the installation of many decorative flashing accessories.
Objects placed in front of the fireplace should be kept a minimum of 4 feet away from the front face.
Minimum clearance to combustible con­struction from fireplace:
sides, back, bottom and top of the unit 0 inch recessed depth 22 inches
4. Install rigid black pipe, 1/2" type-L copper tubing or, if local codes permit, a 3/8" flex connector and shutoff valve to the gas line and the fireplace gas valve. Seal and tighten securely. An adapter fitting is required between the gas valve and the copper tubing or flex connector. DO NOT KINK
FLEXIBLE CONNECTOR. FIGURE 6.
5. Check for gas leaks by brushing on a soap and water solution.
Do not use open flame.
FIGURE 7
Purge all gas lines with the glass door of the fireplace removed. Assure that a continuous gas flow is at the burner before installing the door.
FIGURES 8
FIGURE 9
W415-0377 / C / 09.23.05
FIGURE 10
Page 7
7
NAILING TAB INSTALLATION
1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws sup­plied. Secure through the cen­tre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts.
NAILING TAB
If there are no existing holes, follow these instructions:
Position the nailing tab so that the front face is offset with the front edge of the corner post (approx. ½"). Centre the nailing tab vertically on the corner post.
Figure 12 a.
FIGURE11
Drill through the centre of the top and bottom slots in the nailing tab. Secure using the two sheet metal screws supplied. This allows the nailing tab to slide back and forth for desired framing. Figure 12 b.
2) To determine the final location of the nailing tab you must first determine the thickness of your finishing mate­rial (i.e. drywall). This will determine the dimension from the front edge of the corner post to the nailing tab. Once the nailing tab is in the desired location, drill through the centre hole of the nailing tab. Secure with a sheet metal screw*. Figure 12 c.
* Additional set screws may be installed.
MANTLE CLEARANCES
Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face­areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas.
Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clear­ance needed. Figures 11 a & b.
FIGURES 12a-c
A
FINISHING MATERIAL
CORNER
POST
NAILING
TAB
TOP SLOT
B
FIGURE 13a
FIGURE 13b
CENTRE
HOLE
C
W415-0377 / C / 09.23.05
Page 8
8
FINISHING
LOUVRE BRACKET INSTALLATION
1. Align the holes in the lou­vre brackets with the pre­drilled holes in the firebox, as shown.
2. Secure louvre brackets in place using screws.
FIGURE 14
DOOR INSTALLATION
The upper louvres must be removed to allow the door to be removed. Release the two door latches, located across the top of the door and lift off the lower door bracket.
GDL42 LOUVRE INSTALLATION
Insert the upper louvres into
UPPER LOUVRE
the slots on both brackets.
L42 LOUVRE INSTALLATION
FIGURE 17
A
B
UPPER LOUVRES
Insert the louvre tabs into the
SLOT
TAB
slots located at the top left and right corners of the unit.
15
DOOR LATCH
16
HINGE SCREEN
Attach each hinge on the lower louvre assembly to the lip of the fireplace base with 2 screws. Position the hinge screen into place and with the con­trol door open, secure to the fireplace using three screws.
A
B
HINGE
CLIP
LOGO PLACEMENT
Remove the backing of the logo supplied and place on the glass viewing door, as indicated.
SLOT
LOWER LOUVRES
Insert the hinge clips into the slots located at the bottom left and right corners of the unit.
To remove the louvres, pull the back tabs of the clips forward, while pushing the louvre assem­bly back. Lift the clip.
½"
LOGO
½"
FIGURE 18
W415-0377 / C / 09.23.05
Page 9
LOG PLACEMENT
PHAZERTM logs and glowing embers, exclusive to Napoleon
Fireplaces, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect. Log colours may vary. During the initial use of the fireplace, the colours will become more uniform as colour pigments burn in during the heat activated curing process.
FIGURES 19a-e
#1
1. Place the back log (#1) onto the log support tray and in front of the tabs. The tabs maintain an air space between the log and firebox back to facilitate combustion air flow. Ensure that the back of the log rests against the brackets on the back wall of the firebox.
9
#5
#4
4. Place the bottom of the left crossover log (#4) against the left outermost grate post and the top into the pocket provided on the back log. Position the notch located on the end of the center log (#5) against the middle grate post with the other end of the log resting in the pocket of the left crossover log.
#6
#2
2. Move the two small logs (#2 & #3) into position, lining
up the studs located on the
#3
GLOWING EMBERS
burner with the holes on the bottom of the logs.
3. Tear the glowing embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs (#2 & #3). Care should be taken to shred the embers into thin, small irregular pieces as only the ex­posed edges of the fibre hairs will glow. The ember material
will only glow when exposed to direct flame; however, care should be taken to not block the burner ports. Blocked burner
ports can cause an incorrect flame pattern, carbon deposits
5. Place the bottom of the right crossover log (#6) against the right outermost grate post and the top into the pocket provided on the center log (#5).
CHARCOAL EMBERS
Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner. Fine
dust found in the bottom of the bag should not be used.
VERMICULITE
Sprinkle vermiculite around the charcoal embers.
Note: Both charcoal embers and vermiculite are not to be placed on the burner.
CHARCOAL LUMPS
Place the lumps between the logs in a realistic manner taking care not to block any of the burner ports.
W415-0377 / C / 09.23.05
Page 10
10
OPTIONAL BLOWER INSTALLATION
INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER
and must be electrically connected and grounded in accord­ance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
black
red
white
FIGURE 20
ADJUSTMENT
The three slots allow ease of adjustment of the blower. For a quiet running blower, do not allow the assembly to sit on the firebox base.
FIGURE 21
Slide the vibration reducing pad (A) into the clip and onto the threaded stud (B) at the other end, piercing a hole into the pad. The blower must be able to be positioned entirely onto the pad.
Tilt the blower onto its side. Slide it past the controls and into the clip (C). Secure to the threaded stud using the lock washer and wing nut provided. Ensure that the blower does not touch the fireplace base or the firebox.
SLOTS
B
C
A
FIGURE 22 FIGURE 23
Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the secur­ing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the firebox wall.
THERMODISC
RECEPTACLE /
JUNCTION
GROUND SCREW
FIGURE 24
Attach the connectors from the black and red wires to the blower.
Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the receptacle.
FIGURE 25
BOX
The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained, preventing it from making contact with moving or hot objects.
Because the blower is thermally activated, when turned on, it will automatically start approximately 15 minutes after lighting the fireplace and will run for approximately 30-45 minutes after the fireplace has been turned off. Use of the fan increases the output of heat.
Drywall dust will penetrate into the blower bearings causing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage result­ing from this condition is not covered by the warranty policy.
W415-0377 / C / 09.23.05
Page 11
OPTIONAL FAN INSTALLATION
11
ELECTRICAL INSTALLATION TO BE DONE BY A QUALI­FIED INST ALLER and must be connected and grounded in
accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.
FIGURE 26
The wire harness provided in this kit is a universal har­ness. When installed, ensure that any excess wire is con­tained, preventing it from making contact with moving or hot objects.
Position the vibration reducing pad into the clip and onto the threaded stud at the other end, piercing a hole into the pad. The fan assembly must be able to be positioned en­tirely onto the pad.
OPEN ENDED SLOTS
OPTIONAL THERMOSTATIC
JUNCTION BOX
SENSOR
RECEPTACLE /
VARIABLE SPEED/
PIEZO IGNITOR
FIGURE 27
BRACKET
Slide the fan assembly past the controls and and into the clip. Secure using the lock washer and nut provided.
Plug the harness cord connectors onto the connections of the fan as illustrated. Plug the power cord into the recepta­cle.
THERMOSTATIC SENSOR CONTROL
This optional kit is meant to be used only in conjunction with the GD65 Fan Kit, shown above, which may be ordered from your Wolf Steel / Napoleon dealer.
With the thermostatic sensor option, the fan, when turned on, becomes thermally activated, and will automatically run approximately 10 minutes after the fireplace has been lit and for approximately 30-45 minutes after the fireplace has been turned off.
Use of the fan increases the output of heat. Unplug the power cord from the receptacle. Connect all
wires as shown.
FIGURE 28
Attach and secure the sensor assembly bracket to the se­curing stud located next to the receptacle/junction box at the bottom left of the unit using the lock washer and wing nut. Ensure that the thermodisc touches the firebox wall.
Plug the power cord back into the receptacle. When installed, ensure that any excess wire is contained,
preventing it from making contact with moving or hot ob­jects.
THERMODISC
SENSOR ASSEMBLY
RECEPTACLE /
JUNCTION BOX
BRACKET
FIGURE 29
W415-0377 / C / 09.23.05
Page 12
12
KNOB
OPERATION / MAINTENANCE
OPERATING INSTRUCTIONS
When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condi­tion caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again.
After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. In both cases, open a window to sufficiently ventilate the room.
Purge all gas lines with the glass door of the fireplace removed. Assure that a continuous gas flow is at the burner before installing the door.
FOR YOUR SAFETY READ BEFORE LIGHTING:
A. T his fireplace is equipped with a pilot which must be lit
by hand while following these instructions exactly.
B. Before operating smell all around the fireplace area for
gas and next to the floor because some gas is heavier than air and will settle on the floor.
C. Use only your hand to turn the gas control knob. Never
use tools. If the knob will not turn by hand, do not try to repair it. Call a qualified service technician. Force or at­tempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under wa-
ter. Immediately call a qualified service technician to in­spect the fireplace and replace any part of the control sys­tem and any gas control which has been under water.
LIGHTING INSTRUCTIONS
WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermocou­ple has cooled. Allow approximately 60 seconds for the thermocouple to cool.
When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed slightly.
1. Stop! Read the above safety information on this label.
2. Turn off all electric power to the fireplace.
3. Turn the gas knob clockwise to off.
4. Wait five (5) minutes to clear out any gas. If you smell
gas including near the floor. Stop! Follow "B" in the above safety information on this label. If you don't smell gas go the next step.
TO TURN OFF GAS
1. Turn off all electric power to the fireplace if service is to be performed.
WHAT TO DO IF YOU SMELL GAS
• Turn off all gas to the fireplace.
• Open windows.
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
GAS KNOB
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire de­partment.
FLAME
P
I
L
O
T
ADJUSTMENT
KNOB
L
O
F
O
I
H
F
N
O
P
T
L
I
O
PILOT
ON/OFF
5. Turn gas knob counter-clockwise to pilot.
6. Depress slightly and hold gas knob while lighting the
pilot with the push button ignitor. Keep knob depressed for one minute, then release. If pilot does not continue to burn, repeat steps 3 through 5.
7. With pilot lit, depress and turn gas knob counter-clock­wise to on.
8. If equipped with remote on-off switch/thermostat, main burner may not come on when you turn valve to on. Remote switch must be in the on position to ignite burner.
9. Turn on all electric power to the fireplace.
2. Push in gas control knob slightly and turn clock-
wise to off. Do not force.
W415-0377 / C / 09.23.05
Page 13
PILOT SCREW
MAINTENANCE
Turn off the gas and electrical power before servicing the fireplace.
CAUTION: Label all wires prior to disconnection when serv­icing controls. Wiring errors can cause improper and dan­gerous operation. Verify proper operation after servicing. This fireplace and its venting system should be inspected before use and at least annually by a qualified service per­son. The fireplace area must be kept clear and free of com­bustible materials, gasoline or other flammable vapours and liquids. The flow of combustion and ventilation air must not be obstructed.
1. In order to properly clean the burner and pilot assembly, remove the logs to expose both assemblies.
2. Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacu­uming or brushing, at least once a year.
ADJUSTMENTS
PILOT BURNER ADJUSTMENT
Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow.
13
3. Check to see that all burner ports are burning. Clean out
any of the ports which may not be burning or are not burn­ing properly.
4. Check to see that the pilot flame is large enough to engulf the thermocouple and thermopile and reaches to­ward the burner with the third jet.
5. Replace the cleaned logs.
6. Check to see that the main burner ignites completely on
all openings when the gas knob for the burner is turned on. A 5 to 10 second total light-up period is satisfactory. If igni­tion takes longer, consult your Napoleon dealer / distribu­tor.
7. Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if necessary.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE
BY A QUALIFIED GAS INSTALLER!
L
O
I
H
P
I
L
O
T
F
O
F
N
O
P
L
T
I
O
FIGURE 28
FIGURE 29
VENTURI ADJUSTMENT
FIGURE 30
MODEL BGNV42
NG LP
Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be estab­lished.
1/8"
5/16"
FIGURE 30
Air shutter is accessed beside gas valve
VENTURI
FIGURE 31 (not exactly as shown)
W415-0377 / C / 09.23.05
Page 14
14
REPLACEMENTS
Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor.
When ordering replacement parts always give the follow­ing information:
1. MODEL & SERIAL NUMBER OF FIREPLACE
2. INSTALLATION DATE OF FIREPLACE
3. PART NUMBER
4. DESCRIPTION OF PART
5. FINISH
FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE
ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.
REPLACEMENT PARTS
# PART NO. DESCRIPTION
1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE 4 W010-0800 NATURAL GAS PILOT ASSEMBLY - SIT 4 W010-0801 PROPANE GAS PILOT ASSEMBLY - SIT 5* W660-0005 ON/OFF TOGGLE SWITCH 6 W455-0069 NATURAL GAS PILOT INJECTOR 6 W455-0068 PROPANE GAS PILOT INJECTOR 7 W725-0035 NATURAL GAS VALVE 7 W725-0034 PROPANE VALVE 8* W385-0245 NAPOLEON LOGO 9* W660-0005 STANDARD WALL SWITCH 10* W750-0051 20FT OF WIRE 11 W010-0877 PAN BURNER 12 GL-641 LOG SET 13* W361-0016 GLOWING EMBERS 14* W550-0001 CHARCOAL EMBERS 15* W550-0002 CHARCOAL LUMPS 16 W135-0198 BACK LOG (#1) 17 W135-0201 LEFT CROSSOVER LOG (#4) 18 W135-0202 CENTER LOG (#5) 19 W135-0203 RIGHT CROSSOVER LOG (#6) 20 W135-0199 SMALL LEFT LOG (#2) 21 W135-0200 SMALL RIGHT LOG (#3) 22 W010-0770 BLACK DOOR C/W GLASS 23 W455-0072 #39 NATURAL GAS ORIFICE 23 W455-0059 #53 PROPANE GAS ORIFICE 24* W361-0014 VERMICULITE
* IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR
FURTHER INFORMATION, CONTACT YOUR NAPOLEON
DEALER.
ACCESSORIES
# PART No. DESCRIPTION
25 GDL42K LOUVRE KIT - UPPER & LOWER - BLACK 25 GDL42PB LOUVRE KIT - UPPER & LOWER - POLISHED BRASS 25 GDL42SS LOUVRE KIT - UPPER & LOWER - BRUSHED STAINLESS STEEL 26 L42K LOUVRE KIT - UPPER & LOWER - BLACK 26 L42PB LOUVRE KIT - UPPER & LOWER - POLISHED BRASS 26 L42SS LOUVRE KIT - UPPER & LOWER - BRUSHED STAINLESS STEEL 27 GDOI42BG ORNAMENTAL INSET - BRUSHED GOLD 27 GDOI42K ORNAMENTAL INSET - BLACK 27 GDOI42G ORNAMENTAL INSET - GOLD 27 GDOI42SS ORNAMENTAL INSET - STAINLESS STEEL 28* W690-0001 MILLIVOLT THERMOSTAT 29* W660-0010B REMOTE CONTROL - ADVANTAGE 29* W660-0011B REMOTE CONTROL - ADVANTAGE PLUS 30* W660-0013 MODULATING THERMOSTATIC HAND HELD REMOTE 31* GD825N MODULATING VAL VE REGULATOR FOR W660-0013 - NG 31* GD825P MODULATING VALVE REGULATOR FOR W660-0013 - P 32 GZ550-1KT BLOWER KIT 33* GD65 FAN KIT 34* GD36 35* W500-0033 VARIABLE SPEED SWITCH WALL MOUNTING PLATE 36 GA-566 HOT AIR DISTRIBUTION KIT 37* W690-0005 THERMOSTA T - 110V FOR USE WITH GA-566 ONLY 38* GA-70 EXTENSION KIT - 5 FT 39 GA-72 HOT AIR EXHAUST KIT
THERMOSTATIC SENSOR CONTROL KIT
FOR USE WITH GD
65
ONLY
W415-0377 / C / 09.23.05
Page 15
TROUBLE SHOOTING GUIDE
B
EFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED
SYMPTOM PROBLEM TEST SOLUTION
15
.
Main burner goes out; pilot stays on.
Main burner goes out; pilot goes out.
Pilot goes out when the gas knob is re­leased.
The gas valve has an interlock de­vice which will not allow the pilot burner to be lit until the thermo­couple has cooled. Allow ap­proximately 60 seconds for the thermocouple to cool.
Pilot burning; no gas to main burner; gas knob is on 'HI'; wall switch / ther­mostat is on.
Pilot will not light. - check if pilot can be lit by a match
Pilot flame is not large enough or not engulfing the thermopile
Thermopile shorting - clean thermopile connection to the valve. Reconnect.
Remote wall switch wire is too long; too much resist­ance in the system.
Faulty thermostat or switch. - replace. Vent safety switch has
opened. (Tripped) Hi Limit switch has opened.
(Tripped)
Refer to "MAIN BURNER GOES OUT; PILOT STAYS ON"
Faulty thermocouple. - replace. System is not correctly
purged. Out of propane gas. - fill the tank. Pilot flame is not large
enough Pilot flame is not engulfing
the thermocouple. Thermocouple shorting /
faulty.
Faulty valve.
Themostat or switch is de­fective.
Wall switch wiring is defec­tive.
Main burner orifice is plugged. - remove stoppage in orifice.
Faulty valve. Vent safety switch has opened.
(Tripped) Hi Limit switch has opened. (Tripped)
No spark at pilot burner
Spark gap is incorrect - spark gap should be 0.150" to 0.175" (5/32" to 11/64" approx.) from
No gas at the pilot burner
- turn up pilot flame.
- replace pilot assembly.
- replace thermopile / valve.
- shorten wire to correct length or wire gauge.
- Vent has become blocked or disconnected. Correct. See Figure 2.
- Unit has overheated. See Figure 2
- purge the gas line with the glass door open.
- turn up the pilot flame.
- gently twist the pilot head to improve the flame pattern around the thermocouple.
- loosen and tighten thermocouple.
- clean thermocouple and valve connection.
- replace thermocouple.
- replace.
- connect a jumper wire across the wall switch terminals; if main burner lights, replace switch / thermostat.
- disconnect switch wires & connect a jumper wire across terminals 1 & 3; if the main burner lights, check the wires for defects and / or replace wires.
- replace.
- Vent has become blocked or disconnected. Correct. See Figure 2.
- Unit has overheated. See Figure 2
- check that the wire is connected to the push button ignitor.
- check if the push button ignitor needs tightening.
- replace the wire if the wire insulation is broken or frayed.
- replace the electrode if the ceramic insulator is cracked or broken.
- replace the push button ignitor.
- fill the tank.Out of propane gas
the electrode tip and the pilot burner. To ensure proper electrode location, tighten securing nut (finger tight plus 1/4 turn).
- check that the manual valve is turned on.
- check the pilot orifice for blockage.
- replace the valve.
- call the gas distributor.
W415-0377 / C / 09.23.05
Page 16
16
SYMPTOM PROBLEM TEST SOLUTION
Pilot goes out while standing; Main burner is in 'OFF' position.
Flames are con­sistently too large or too small. Carboning occurs.
P
I
L
O
T
Carbon is being deposited on glass, logs or combustion chamber surfaces.
Gas piping is undersized. - turn on all gas appliances and see if pilot flame flutters, diminishes
or extinguishes, especially when main burner ignites. Monitor appli­ance supply working pressure.
- check if supply piping size is to code. Correct all undersized piping.
Unit is over-fired or under­fired.
- check pressure readings: Inlet pressure can be checked by turning screw (A) counter-clock­wise 2 or 3 turns and then placing pressure gauge tubing over the
A
B
test point. Gauge should read 7" (minimum 4.5") water column for natural gas or 13" (11" minimum) water column for propane. Check that main burner is operating on "HI".
L
O
F
I
H
O
F
N
O
P
L
T
I
O
Outlet pressure can be checked the same as above using screw (B). Gauge should read 3.5" water column for natural gas or 10" water column for propane. Check that main burner is operating on "HI". AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVERTORQUE. Leak test with a soap and water solution.
Air shutter has become
- ensure air shutter opening is free of lint or other obstructions.
blocked
Flame is impinging on the logs or combustion cham­ber.
- check that the logs are correctly positioned.
- open air shutter to increase the primary air.
- check the input rate: check the manifold pressure and orifice size as specified by the rating plate values.
- check to ensure proper venting action
White / grey film forms.
Exhaust fumes smelled in room, headaches.
Main burner flame is a blue, lazy, transparent flame.
Remote wall switch is in "OFF" position; main burner comes on when gas knob is turned to "ON" position.
Sulphur from fuel is being deposited on glass, logs or combustion chamber sur­faces.
- clean the glass with a recommended gas fireplace glass cleaner. DO NOT CLEAN GLASS WHEN HOT.
If deposits are not cleaned off regularly, the glass may become per­manently marked.
Fireplace is spilling. - check for chimney blockage
- check that chimney is installed to building code.
- room is in negative pressure; increase fresh air supply.
Not enough combustion air - room is in negative pressure; increase fresh air supply
Wall switch is mounted up-
- reverse.
side down
- replace.Remote wall switch is
grounding.
- check for ground (short); repair ground or replace wire.Remote wall switch wire is
grounding. Faulty valve.
- replace.