Mantle Height Locations
Log Placement
Logo Placement
Louvre Installation
Door & Louvre Installation
End Door Installation
26OPTIONAL BLOWER INSTALLATION
27OPERATION / MAINTENANCE
Operating Instructions
Maintenance
28ADJUSTMENTS
Pilot Burner Adjustment
Venturi Adjustments
Restricting Vertical Vents
29-30 REPLACEMENTS
Ordering Replacement Parts
Replacement Parts
Vent Kits
Terminal Kits
31ACCESSORIES
32-33 TROUBLE SHOOTING GUIDE
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
WARNING
• Do not burn wood or other materials in this fireplace.
• Adults and especially children should be alerted to the hazards of high surface temperatures and should stay
away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the
fireplace.
• Due to high temperatures, the fireplace should be located out of traffic and away from furniture and draperies.
• Clothing or other flammable material should not be placed on or near the fireplace.
• Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace.
• It is imperative that the control compartments, burners and circulating blower and its passageway in the fireplace
and venting system are kept clean. The fireplace and its venting system should be inspected before use and at
least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from
carpeting, bedding material, etc. The fireplace area must be kept clear and free from combustible materials,
gasoline and other flammable vapours and liquids.
• Under no circumstances should this fireplace be modified.
• This fireplace must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.
• Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect
the fireplace and to replace any part of the control system and any gas control which has been under water.
• Do not operate the fireplace with the glass door removed, cracked or broken. Replacement of the glass should be
done by a licensed or qualified service person.
• Do not strike or slam shut the fireplace glass door.
• This fireplace uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
W415-0299 / C / 03.12.03
NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized
ISO 9001 : 2000 Quality Assurance Certificate.
NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen
who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test
station. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that
you, the customer, receives the quality product that you expect from NAPOLEON.
NAPOLEON GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY
3
The following materials and workmanship in your new The following materials and workmanship in your new
The following materials and workmanship in your new
The following materials and workmanship in your new The following materials and workmanship in your new
ranted against defects for as long as you own the fireplace. This covers: combustion chamber,ranted against defects for as long as you own the fireplace. This covers: combustion chamber,
ranted against defects for as long as you own the fireplace. This covers: combustion chamber,
ranted against defects for as long as you own the fireplace. This covers: combustion chamber,ranted against defects for as long as you own the fireplace. This covers: combustion chamber,
heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakageheat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage
heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakageheat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage
only), gold plated parts against tarnishing, porcelainized enamelled components and aluminumonly), gold plated parts against tarnishing, porcelainized enamelled components and aluminum
only), gold plated parts against tarnishing, porcelainized enamelled components and aluminum
only), gold plated parts against tarnishing, porcelainized enamelled components and aluminumonly), gold plated parts against tarnishing, porcelainized enamelled components and aluminum
extrusion trims.extrusion trims.
extrusion trims.
extrusion trims.extrusion trims.
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,
thermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly arethermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are
thermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are
thermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly arethermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are
covered and covered and
covered and
covered and covered and
the limited warranty.the limited warranty.
the limited warranty.
the limited warranty.the limited warranty.
Labour related to warranty repair is covered free of charge during the first year. Repair work,Labour related to warranty repair is covered free of charge during the first year. Repair work,
Labour related to warranty repair is covered free of charge during the first year. Repair work,
Labour related to warranty repair is covered free of charge during the first year. Repair work,Labour related to warranty repair is covered free of charge during the first year. Repair work,
however, requires the prior approval of an authorized company official. Labour costs to thehowever, requires the prior approval of an authorized company official. Labour costs to the
however, requires the prior approval of an authorized company official. Labour costs to the
however, requires the prior approval of an authorized company official. Labour costs to thehowever, requires the prior approval of an authorized company official. Labour costs to the
account of account of
account of
account of account of
be done through an authorized be done through an authorized
be done through an authorized
be done through an authorized be done through an authorized
NAPOLEONNAPOLEON
NAPOLEON
NAPOLEONNAPOLEON
NAPOLEONNAPOLEON
NAPOLEON
NAPOLEONNAPOLEON
will provide replacement parts free of charge during the first year ofwill provide replacement parts free of charge during the first year of
will provide replacement parts free of charge during the first year of
will provide replacement parts free of charge during the first year ofwill provide replacement parts free of charge during the first year of
are based on a predetermined rate schedule and any repair work must are based on a predetermined rate schedule and any repair work must
are based on a predetermined rate schedule and any repair work must
are based on a predetermined rate schedule and any repair work must are based on a predetermined rate schedule and any repair work must
NAPOLEONNAPOLEON
NAPOLEON
NAPOLEONNAPOLEON
dealer. dealer.
dealer.
dealer. dealer.
NAPOLEONNAPOLEON
NAPOLEON
NAPOLEONNAPOLEON
gas fireplace are war- gas fireplace are war-
gas fireplace are war-
gas fireplace are war- gas fireplace are war-
CONDITIONS AND LIMITATIONS
NAPOLEON warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears on the
warranty registration card filed with NAPOLEON -- provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following conditions and limitations:
This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives.
The gas fireplace must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the
product and all local and national building and fire codes.
This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this
warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel
parts, mechanical breakage of PHAZER™ logs and embers, nor any venting components used in the installation of the fireplace.
NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During the first 10 years NAPOLEON will replace
or repair the defective parts at our option free of charge. From 10 years to life, NAPOLEON will provide replacement burners at 50% of the current retail price.
In the first year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in
accordance with the operation instructions and under normal conditions.
After the first year, with respect to this President's Limited Lifetime Warranty, NAPOLEON may, at its discretion, fully discharge all obligations with respect to this warranty by refunding
to the original warranted purchaser the wholesale price of any warranted but defective part(s).
After the first year, NAPOLEON will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not
covered by this warranty.
Notwithstanding any provisions contained in this President's Limited Lifetime Warranty, NAPOLEON’S responsibility under this warranty is defined as above and it shall not in any event
extend to any incidental, consequential or indirect damages.
This warranty defines the obligations and liability of NAPOLEON with respect to the NAPOLEON gas fireplace and any other warranties expressed or implied with respect to this product,
its components or accessories are excluded.
NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. NAPOLEON will not be responsible for:
over-firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting configurations, insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
Any damages to fireplace, combustion chamber, heat exchanger, brass trim or other component due to water, weather damage, long periods of dampness, condensation, damaging
chemicals or cleaners will not be the responsibility of NAPOLEON.
The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration card
must be returned within fourteen days to register the warranty.
NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.
THIS GAS FIREPLACE SHOULD BE INSTALLED AND
SERVICED BY A QUALIFIED INSTALLER to conform with
local codes. Installation practices vary from region to region and it is important to know the specifics that apply to
your area,
for example: in Massachusetts State:
• The fireplace damper must be removed or welded in the open
position prior to installation of a fireplace insert or gas log.
• The appliance off valve must be a “T” handle gas cock.
• The flexible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bedroom or
bathroom unless the unit is a direct vent sealed combustion
product.
• WARNING: This product must be installed by a licensed plumber
or gas fitter when installed within the commonwealth of
Massachusetts.
In absence of local codes, install to the current CAN/CGA B149 Installation Code in Canada or to the National Fuel
Gas Code, ANSI Z223.1, and NFPA 54 in the United States.
Mobile home installation must conform with local codes.
In the absence of local codes, install to the current standard for gas equipped mobile housing CAN/CSA Z240 MH
Series in Canada or the manufactured home construction
and safety standard, Title 24 CFR, part 3280, or the Fire
Safety Criteria for manufactured home installations, Sites
and Community Standard ANSI/NFPA 5OIA in the United
States.
Purge all gas lines with the glass door of the fireplace
open. Assure that a continuous gas flow is at the burner
before closing the door.
Under extreme vent configurations, allow several minutes (5-15) for the flame to stabilize after ignition.
The fireplace and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The fireplace must be isolated
from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the
gas supply piping system at test pressures equal to or
less than 1/2 psig (3.5 kPa).
When the fireplace is installed directly on carpeting, vinyl
tile or other combustible material other than wood flooring,
the fireplace shall be installed on a metal or wood panel
extending the full width and depth.
If the optional heat circulating blower is installed, the blower
must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use
the current CSA C22.1 CANADIAN ELECTRICAL CODE in
Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL
CODE in the United States.
Minimum clearance to combustible construction from fireplace and vent surfaces:
sides, back, bottom, and top0 inches
vent pipe1 inch
recessed depth (corner installation)
W415-0299 / C / 03.12.03
25¼25¼
25¼ inches
25¼25¼
FOR YOUR SATISFACTION, ALL BURNER ASSEMBLIES
HAVE BEEN TEST-FIRED TO ASSURE THEIR OPERATIONS AND QUALITY! Maximum input is 30,000 BTU/h
for natural gas and propane. When the fireplace is installed
at elevations above 4,500ft, and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced
at the rate of 4% for each additional 1,000ft. Maximum output for natural gas is 20,400 BTU/hr at an efficiency of 68%
with the fan on.
Minimum inlet gas supply pressure is 4.5 inches water
column for natural gas and 11 inches water column for
propane. Maximum inlet gas pressure is 7 inches water
column for natural gas and 13 inches water column for
propane. Manifold pressure under flow conditions is 3.5
inches water column for natural gas and 10 inches water
column for propane.
This fireplace is approved for bathroom, bedroom and bedsitting room installations and is suitable for mobile home
installation
NO EXTERNAL ELECTRICITY (110 VOLTS OR 24 VOLTS) IS
REQUIRED FOR THE GAS SYSTEM OPERATION. Expan-
sion / contraction noises during heating up and cooling
down cycles are normal and are to be expected.
If utilizing one of Wolf Steel's trim or surround kits, follow
the framing instructions on page 14 and the finishing instructions on page 23, for removal of the top extension.
CARE OF GLASS, AND PLATED PARTS
Do not use abrasive cleaners to clean these parts. Buff
lightly with a clean dry cloth. The glass is 3/16" tempered
glass available from your Napoleon / Wolf Steel Ltd. dealer.
Do not substitute materials.
If the door glass should crack or break, do not operate the
fireplace. Replace only with a door assembly certified with
the fireplace. See DOOR, LOUVRE AND TRIM INSTALLA-TION for removal and replacement details. Clean the glass
after the first 10 hours of operation with a recommended
gas fireplace glass cleaner. Thereafter clean as required.
Do not clean glass when hot!
If the glass is not kept clean permanent discolouration
and / or blemishes may result.
Provide adequate ventilation air. Provide adequate
accessibility clearance for servicing and operating
the fireplace. Never obstruct the front opening of
the fireplace.
For safe and proper operation of the fireplace follow
the venting instruction exactly.
Deviation from the minimum vertical vent length can
create difficulty in burner start-up and/or carboning.
Provide a means for visually checking the vent connection to the fireplace after the fireplace is installed.
In order to avoid the possibility of exposed
insulation or vapour barrier coming in contact
with the fireplace body, it is recommended that
the walls of the fireplace enclosure be “finished”
(ie: drywall/sheetrock), as you would finish any
other outside wall of a home. This will ensure
that clearance to combustibles is maintained
within the cavity.
5
Vent lengths that pass through unheated spaces (attics, garages, crawl spaces) should be insulated
with the insulation wrapped in a protective sleeve
to minimize condensation.
DIMENSIONS
PENINSULA
FIGURE 1a
OPEN-END
FIGURE 1b
Objects placed in front of the fireplace must be kept
a minimum of 48" away from the glass front faces of
the unit.
FIGURE 1c
SEE-THRU
W415-0299 / C / 03.12.03
6
VENTING
VENTING LENGTHS
Use only Wolf Steel or Simpson Dura-Vent Model DV-GS
venting components. Minimum and maximum vent lengths,
for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual
and must be adhered to. For Simpson Dura-Vent, follow
the installation procedure provided with the venting components.
When using Wolf Steel venting components, use only approved Wolf Steel rigid / flexible components with the following termination kits: WALL TERMINAL KIT GD422, or
1/12 TO 7/12 PITCH ROOF TERMINAL KIT GD410, 8/12 TO
12/12 ROOF TERMINAL KIT GD411, FLAT ROOF TERMI-
NAL KIT GD412 or PERISCOPE KIT GD401 (for wall pen-
etration below grade). With flexible venting, in conjunction
with the various terminations, use either the 5 foot vent kit
GD420 or the 10 foot vent kit GD430.
Wolf Steel rigid and flexible venting systems must not
be combined.
Wolf Steel and Simpson Dura-Vent venting systems
must not be combined.
These vent kits allow for either horizontal or vertical venting
of the fireplace. The maximum allowable horizontal run is
20 feet. The maximum allowable vertical vent length is 40
feet. The maximum number of 5" vent connections is two
horizontally or three vertically (excluding the fireplace and
the air terminal connections) when using aluminum flexible venting.
For optimum flame appearance and fireplace performance, keep the vent length and number of elbows to a
minimum.
The air terminal must remain unobstructed at all times.
Examine the air terminal at least once a year to verify
that it is unobstructed and undamaged.
Purge all gas lines with the glass door of the fireplace
open. Assure that a continuous gas flow is at the burner
before closing the door.
Under extreme vent configurations, allow several minutes
(5-15) for the flame to stabilize after ignition.
Nine (9") inches is the minimum bend radius allowed
for the 8" diameter flexible liner.
For optimum performance it is recommended that all
horizontal runs have a 1 inch rise per foot when using
Napoleon flexible vent components.
A terminal shall not terminate directly above a sidewalk
or paved driveway which is located between two single family dwellings and serves both dwellings. Local
codes or regulations may require different clearances.
Do not allow the inside liner to bunch up on horizontal or
vertical runs and elbows. Keep it pulled tight. A 1¼" air
gap all around between the inner liner and outer liner is
required for safe operation. Use a firestop when penetrating interior walls, floor or ceiling.
Horizontal runs may have a 0 inch rise per foot in all
cases using SIMPSON DURA-VENT or NAPOLEON
RIGID OR FLEXIBLE venting components when venting.
A clearance to combustibles of 1" all around the vent
pipe is required.
W415-0299 / C / 03.12.03
AIR TERMINAL INSTALLATIONS
a
s
FIGURE 2
INSTALLATIONS
CANADIANU. S.A.
A
12 INCHES
12 INCHES
Clearance above grade, veranda porch, deck or balcony.
7
B
C
12 INCHES
12 INCHES*
9 INCHES
12 INCHES*
Clearance to windows or doors that open.
Clearance to permanently closed windows.
Vertical clearance to ventilated soffit located above the terminal within
D
18 INCHES**
12 INCHES**
E
F
0 INCHES
0 INCHES***
G
2 INCHES***
H
I
J
K
L
M
N
O
*
*Re commended to prevent condensation on windows and thermal breakage
*
****
**It is recommended to use a heat shield and to maximize the distance to vinyl clad soffits.
****
** *** *
** *The periscope GD-201 requires a min imu m 18 inches clearance from an inside corner.
** *** *
** **** **
** ** This is a reco mmended distance. For additional requirements check loca l codes.
** **** **
††
†Th ree feet abo ve if within 10 feet horizontally.
††
‡‡
‡A vent shall not terminate dir ectly above a sid ewalk or paved driveway that is located between two single f
‡‡
† †† †
† †Pe rmitted only if the veranda, porch, or deck is ful ly open on a minimum of two sides beneath the floor.
† †† †
† *† *
† *Recomme nce d to prevent recirculation of exhaust pro ducts. For add iti onal requirements check local cod e
† *† *
3 FEET
3 FEET
12 INCHES
6 FEET
7 FEET‡
12 INCHES††
16 INCHES
2 FEET†*
dwe llings and serves both dwellings.
18 INCHES**
12 INCHES**
0 INCHES
0 INCHES***
2 INCHES***
3 FEET****
3 FEET****
9 INCHES
3 FEET†
7 FEET****
12 INCHES****
16 INCHES
2 FEET†*
a horizontal distance of 2 feet from the centerline of the terminal.
Clearance to unventilated soffit.
Clearance to an outside corner wall.
Clearance to an inside non-combustible corner wall or protruding
non-combustible obstructions (chimney, etc.).
Clearance to an inside combustible corner wall or protruding combustible obstructions ( vent chase, etc.).
Clearance to each side of the centerline extended above the meter
/ regulator assembly to a maximum vertical distance of 15ft.
Clearance to a service regulator vent outlet.
Clearance to a non-mechanical air supply inlet to the building or a
combustion air inlet to any other appliance.
Clearance to a mechanical air supply inlet.
Clearance above a paved sidewalk or paved driveway located on
public property unless fitted with a heat shield kit GD-301.
Clearance under a veranda, porch, deck or balcony.
Clearance above the roof.
Clearance from an adjacent wall including neighbouring buildings.
W415-0299 / C / 03.12.03
8
VENTING APPLICATION FLOWCHART
VERVER
TICALTICAL
VER
TICAL
VERVER
HORIZONTHORIZONT
HORIZONT
HORIZONTHORIZONT
TERMINTERMIN
TERMIN
TERMINTERMIN
vertical risevertical rise
vertical rise
vertical risevertical rise
is equal tois equal to
is equal to
is equal tois equal to
or greateror greater
or greater
or greateror greater
than thethan the
than the
than thethan the
horizontalhorizontal
horizontal
horizontalhorizontal
runrun
run
runrun
ALAL
AL
ALAL
AA
TIONTION
A
TION
AA
TIONTION
vertical risevertical rise
vertical rise
vertical risevertical rise
is less thanis less than
is less than
is less thanis less than
horizontalhorizontal
horizontal
horizontalhorizontal
runrun
run
runrun
TERMINTERMIN
TERMIN
TERMINTERMIN
vertical risevertical rise
vertical rise
vertical risevertical rise
is equal tois equal to
is equal to
is equal tois equal to
or greateror greater
or greater
or greateror greater
than thethan the
than the
than thethan the
horizontalhorizontal
horizontal
horizontalhorizontal
runrun
run
runrun
TICALTICAL
AA
TIONTION
A
TION
AA
TIONTION
verticalvertical
vertical
verticalvertical
rise is lessrise is less
rise is less
rise is lessrise is less
than hori-than hori-
than hori-
than hori-than horizontal runzontal run
zontal run
zontal runzontal run
horizontalhorizontal
horizontal
horizontalhorizontal
run + verti-run + verti-
run + verti-
run + verti-run + vertical rise tocal rise to
cal rise to
cal rise tocal rise to
maximummaximum
maximum
maximummaximum
of 40 feetof 40 feet
of 40 feet
of 40 feetof 40 feet
horizontalhorizontal
horizontal
horizontalhorizontal
run + verti-run + verti-
run + verti-
run + verti-run + vertical rise tocal rise to
cal rise to
cal rise tocal rise to
maximum ofmaximum of
maximum of
maximum ofmaximum of
24.75 feet24.75 feet
24.75 feet
24.75 feet24.75 feet
4.2 times4.2 times
4.2 times
4.2 times4.2 times
the verticalthe vertical
the vertical
the verticalthe vertical
rise equal torise equal to
rise equal to
rise equal torise equal to
or greateror greater
or greater
or greateror greater
than thethan the
than the
than thethan the
horizontalhorizontal
horizontal
horizontalhorizontal
runrun
run
runrun
horizontalhorizontal
horizontal
horizontalhorizontal
run + verti-run + verti-
run + verti-
run + verti-run + vertical rise tocal rise to
cal rise to
cal rise tocal rise to
maximummaximum
maximum
maximummaximum
of 40 feetof 40 feet
of 40 feet
of 40 feetof 40 feet
horizontalhorizontal
horizontal
horizontalhorizontal
run + verti-run + verti-
run + verti-
run + verti-run + vertical rise tocal rise to
cal rise to
cal rise tocal rise to
maximummaximum
maximum
maximummaximum
of 40 feetof 40 feet
of 40 feet
of 40 feetof 40 feet
3 times the3 times the
3 times the
3 times the3 times the
vertical risevertical rise
vertical rise
vertical risevertical rise
equal to orequal to or
equal to or
equal to orequal to or
greatergreater
greater
greatergreater
than thethan the
than the
than thethan the
horizontalhorizontal
horizontal
horizontalhorizontal
runrun
run
runrun
W415-0299 / C / 03.12.03
TYPICAL VENT INSTALLATIONS
FIGURE 3a
When venting, the horizontal run must be kept to a minimum of 10 inches or a maximum of 20 feet. If a 20 foot
horizontal run is required, the fireplace must have a minimum vertical rise immediately off the fireplace of 57 inches.
FIGURE 3a.
9
When terminating
vertically, the vertical
rise is a minimum 34
inches and a maximum 40 feet above
the fireplace. FIGURE
3b.
FIGURE 3b
SPECIAL VENT INSTALLATIONS
PERISCOPE TERMINATION
Use the GD401 periscope kit to locate the air termination
above grade. The periscope must be installed so that when
final grading is completed, the bottom air slot is located a
minimum of 12 inches above grade. The maximum allowable vent length depends on the model of fireplace, as
illustrated.
FIGURE 4
W415-0299 / C / 03.12.03
10
DEFINITIONS
for the following symbols used in the venting calculations and examples are:
> - greater than
> - equal to or greater than
< - less than
< - equal to or less than
HT- total of both horizontal vent lengths (HR) and offsets (HO) in feet
HR- combined horizontal vent lengths in feet
HO- offset factor: .03(total degrees of offset - 135°
feet
VT- combined vertical vent lengths in feet
**
*) in
**
HORIZONTAL TERMINATION
when (HT) < (VT)
Simple venting configuration (only one 45º and 90° elbow)
90°
FIGURE 5
ELBOW VENT LENGTH VALUES
feetinches
1°0.030.5
15°0.456.0
30°0.911.0
**
45°
*1.3516.0
**
**
90°
*2.732.0
**
* *
* the first 45º and 90° offset has a zero value and is
* *
shown in the formula as -45° and -90º respectively or
-135º when combined.
For vent configurations requiring more than one 45º and
90° elbow, the following formulas apply:
Formula 1: HT < V
T
Formula 2: HT + VT < 40 feet
Example 1:
H
2
90°
45º
HT- total of both horizontal vent lengths (HR) and offsets
(HO) in feet
REQUIRED
VERTICAL
RISE IN FEET
(VT)
CALCULATED HORIZONTAL VENT RUN
PLUS OFFSETS IN FEET (HT)
The shaded area within the lines represents acceptable
values for HT and V
.
T
FIGURE 6
45º
V1=8 ft
VT=
H1= 2.5 ft
H2=2 ft
HR= H1 + H2 = 2.5 + 2 = 4.5 ft
HO=.
=0.3(225-135º) = 2.7ft
HT= HR + HO = 4.5 + 2.7 = 7.2 ft
H
Formula 1:H
Formula 2:HT + VT < 40 feet
V1 = 8 ft
03(one 45º elbow + two 90º elbows - 135º)
+ VT = 7.2 +8 =15.2ft
T
< V
T
7.2 < 8
15.2 < 40
T
H
V
1
90°
1
W415-0299 / C / 03.12.03
Since both formulas are met, this vent configuration is acceptable.
HORIZONTAL TERMINATION
11
when (HT) > (VT)
Simple venting configuration (only one 45º and 90° elbow)
FIGURE 7
See graph to determine the required vertical rise VT for the required
horizontal run HT.
REQUIRED
VERTICAL
RISE IN
INCHES (VT)
Example 2:
FIGURE 8
45°
H
V
1
V
T
H
1
H
2
H
3
H
4
H
R
H
O
H
T
HT + VT= 10.9 + 4 = 14.9 ft
=4 ft
= V
= 4 ft
1
=2 ft
=1 ft
=1 ft
= 1.5 ft
= H1 + H2 + H3 + H4 = 2 + 1 + 1 + 1. 5 = 5.5 ft
= .03(one 45º elbow + three 90º elbow -135º)
=.03(315-135)=5.4ft
= HR + HO = 5.5 +5.4 = 10.9 ft
90°
H
V
4
1
90°
H
3
H
2
1
90°
HORIZONTAL VENT RUN PLUS OFFSETS IN FEET (HT)
The shaded area within the lines represents acceptable
values for HT and V
.
T
For vent configurations requiring more than one 45º and
90° elbow the following formulas apply:
Formula 1: HT < 4.2 V
T
Formula 2: HT + VT < 24.75 feet
Formula 1: HT < 4.2 V
T
4.2 VT = 4.2 x 4 = 16.8 ft
10.9 < 16.8
Formula 2: HT + VT < 24.75 feet
14.9 < 24.75
Since both formulas are met, this vent configuration is acceptable.
W415-0299 / C / 03.12.03
Loading...