Napoleon XIR4-1N, XIR4-1P Installation And Operating Instructions Manual

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
EN
INSTALLATION AND
OPERATING INSTRUCTIONS
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
!
WARNING
If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life.
- Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used.
!
XIR4-1N
NATURAL GAS
XIR4-1P
PROPANE
WARNING
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
FR PG 37
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
$10.00
1.36B
CERTIFIED
W415-1194 / 03.04.13
2
TABLE OF CONTENTS
EN
1.0 INSTALLATION OVERVIEW 3
2.0 INTRODUCTION 4
2.1 DIMENSIONS 5
2.2 MINIMUM CLEARANCE TO COMBUSTIBLES 5
2.3 GENERAL INSTRUCTIONS 5
2.4 GENERAL INFORMATION 6
2.5 RATING PLATE INFORMATION 7
3.0 INSTALLATION 8
3.1 LEVELLING THE APPLIANCE 8
3.2 CHIMNEY CONNECTION 9
3.3 GAS INSTALLATION 10
4.0 FINISHING 11
4.1 MINIMUM MANTEL CLEARANCES 11
4.2 DOOR REMOVAL AND INSTALLATION 12
4.3 LOG PLACEMENT 13
4.4 BATTERY INSTALLATION 14
4.5 OPTIONAL ROCK PLACEMENT 15
4.6 GLOWING EMBERS 15
4.7 LOGO PLACEMENT 15
5.0 ELECTRICAL INFORMATION 16
5.1 WIRING DIAGRAM 16
6.0 OPERATION 17
6.1 OPERATING AND LIGHTING INSTRUCTIONS 17
6.2 GENERAL TRANSMITTER LAYOUT 18
6.3 APPLIANCE OPERATION 18
6.4 HAND HELD REMOTE OPERATIONS 18
6.5 TEMPERATURE DISPLAY 19
6.6 ROOM THERMOSTAT 19
6.7 SMART THERMOSTAT 19
6.8 FLAME HEIGHT 20
6.9 CHILD PROOF FUNCTION 20
6.10 NIGHT LIGHT 20
6.11 LOW BATTERY / MANUAL BYPASS 21
6.12 IN THE EVENT OF A POWER FAILURE 21
6.13 CONTROL MODULE 21
6.14 SPLIT FLOW VALVE 21
6.15 ANTI CONDENSATION CONTROL SWITCH (OPTIONAL) 22
6.16 TIMED BLOWER 22
7.0 ADJUSTMENTS 22
7.1 PILOT BURNER ADJUSTMENT 22
7.2 VENTURI ADJUSTMENT 23
7.3 FLAME CHARACTERISTICS 23
8.0 MAINTENANCE 24
8.1 CARE OF GLASS 24
8.2 CARE OF PLATED PARTS 24
8.3 DOOR GLASS REPLACEMENT 25
8.4 BURNER REMOVAL 26
8.5 FCM REPLACEMENT 26
8.6 NIGHT LIGHT™ REPLACEMENT 27
8.7 VALVE TRAIN REPLACEMENT 27
9.0 REPLACEMENTS 28
10.0 TROUBLESHOOTING 32
11.0 WARRANTY 35
12.0 SERVICE HISTORY 36
NOTE: changes, other than editorial, are denoted by a vertical line in the margin.
W415-1194 / 03.04.13
1.0 INSTALLATION OVERVIEW
3
EN
Venting, see “INSTALLATION
- CHIMNEY CONNECTION” section.
Rating Plate, see “RATING PLATE INFORMATION” section.
Logs, see “FINISHING - LOG PLACEMENT” section.
W415-1194 / 03.04.13
4
2.0 INTRODUCTION
EN
!
WARNING
THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.
ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED.
Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi re or injury.
• Risk of fi re or asphyxiation do not operate appliance with fi xed glass removed.
Do not connect 110 volts to the control valve.
Risk of burns. The appliance should be turned off and cooled before servicing.
Do not install damaged, incomplete or substitute components.
Risk of cuts and abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges may be sharp.
Do not burn wood or other materials in this appliance.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to
avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers,
young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to an appliance, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
Clothing or other fl ammable material should not be placed on or near the appliance.
Due to high temperatures, the appliance should be located out of traffi c and away from furniture and draperies.
Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot surfaces.
Even after the appliance is out, the glass and/or screen will remain hot for an extended period of time.
Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces. These screens and guards must be fastened to the fl oor.
Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.
The appliance is a vented gas-fi red appliance. Do not burn wood or other materials in the appliance
It is imperative that the control compartments, burners and circulating blower and its passageway in the appliance and venting system are kept clean. The appliance and its venting system should be inspected before use and at least annually by a qualifi ed service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The appliance area must be kept clear and free from combustible materials, gasoline and other fl ammable vapors and liquids.
Under no circumstances should this appliance be modifi ed.
This appliance must not be connected to a chimney fl ue pipe serving a separate solid fuel burning appliance.
Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the glass should be done by a licensed or qualifi ed service person.
Do not strike or slam shut the appliance glass door.
When equipped with pressure relief doors, they must be kept closed while the appliance is operating to prevent exhaust fumes containing carbon monoxide, from entering into the home. Temperatures of the exhaust escaping through these openings can also cause the surrounding combustible materials to overheat and catch re.
Only doors / optional fronts certifi ed with the appliance are to be installed on the appliance.
Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with all plastic bags, these are not toys and should be kept away from children and infants.
As with any combustion appliance, we recommend having your appliance regularly inspected and serviced as well as having a Carbon Monoxide Detector installed in the same area to defend you and your family against Carbon Monoxide.
Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance. Elevated temperatures on the wall or in the air above the appliance can cause melting, discolouration or damage of decorations, a T.V. or other electronic components.
W415-1194 / 03.04.13
3.2B
2.1 DIMENSIONS
THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifi cs that apply to your area, for example in Massachusetts State:
This product must be installed by a licensed plumber or gas fi tter when installed within the commonwealth of Massachusetts.
The appliance damper must be removed or welded in the open position prior to installation of a appliance insert or gas log.
The appliance off valve must be a “T” handle gas cock.
• The fl exible connector must not be longer than 36 inches (914.4mm).
A Carbon Monoxide detector is required in all rooms containing gas fi red appliances.
The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.
5
241/2”
(622.3mm)
241/4”
(616mm)
11”
(279.4mm)
111/2”
(292.1mm)
165/8”
(422.3mm)
213/8”
(542.9mm)
2.2 MINIMUM CLEARANCE TO COMBUSTIBLES
This appliance must be recessed into a vented noncombustible wood-burning appliance (prefabricated or masonry) only. The minimum appliance opening size in which the appliance is to be installed is:
HEIGHT 25" (635mm) WIDTH 34.25" (870mm) DEPTH 17" (431.8mm) The minimum allowable chimney fl ue size is 7" (177.8mm) round.
The minimum distance, from the bottom of a combustible mantel projecting 3" (76.2mm) maximum from the wall to the top of the appliance, is 14" (355.6mm) (see "MINIMUM MANTEL CLEARANCES" section).
2.3 GENERAL INSTRUCTIONS
!
WARNING
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,
WITH THE GLASS DOOR OPENED OR REMOVED.
PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.
PROVIDE ADEQUA TE VENTILA TION.
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48” (1219.2mm)
FROM THE FRONT FACE OF THE APPLIANCE.
SURFACES AROUND AND ESPECIALLY ABOVE THE APPLIANCE CAN BECOME HOT. AVOID CONTACT
WHEN THE APPLIANCE IS OPERATING.
FIRE RISK. EXPLOSION HAZARD.
HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TESTING GAS
LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFORE PRESSURE
TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG (35 mb).
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE.
USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING
COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
335/8” (854.1mm) 251/4” (641.4mm)
(317.5mm)
343/4” (882.7mm)
(422.3mm)
121/2”
165/8”
EN
W415-1194 / 03.04.13
6
4.12A
sealed combustion product.
The installation must conform with local codes or, in absence of local codes, the National Gas and Propane Installation Code CSA B149.1 in Canada, or the National Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United States. Suitable for mobile home installation if installed in accordance with the current standard CAN/CSA Z240MH Series, for gas equipped mobile homes, in Canada or ANSI Z223.1 and NFPA 54 in the United States.
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
We suggest that our gas hearth products be installed and serviced by professionals who are certied in the U.S. by the National Fireplace Institute
®
(NFI) as NFI Gas
Specialists
www.ncertied.org
EN
2.4 GENERAL INFORMATION
FOR YOUR SA TISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY!
XIR4-1
NG LP
Altitude (FT) 0-4,500 0-4,500 Max. Input (BTU/HR) 40,000 40,000 Max. Output (BTU/HR) 33,200 33,200 Effi ciency (w/the fan on) 83% 83% A.F.U.E. (maximum value) 79% 79% Min. Inlet Gas Supply Pressure 4.5" Water Column
(11.2mb)
Max. Inlet Gas Supply Pressure 7" Water Column
(17.4mb)
Manifold Pressure (Under Flow Conditions) 3.5" Water Column
(8.7mb)
W415-1194 / 03.04.13
11" Water Column
(27.4mb)
13" Water Column
(32.4mb)
10" Water Column
(24.9mb)
When the appliance is installed at elevations above 4,500ft (1371.6m), and in the absence of specifi c
APPLIANCEAPPLIANC
LL
LL
COMECOME
NIN
SUPPLIED B SUPPLIED B
UTHE MANU
FF
ACTURERACTURE
XIR4PXIR4P
ProPr
CE FOYCE F
CONCON
HE APPROPRIATE WOLF STEEL VENT KPRIATE WOLF STEEL VENT K
A VENTED NON-COMBUSTIBLE FIREPLAA VENTED NON-COMBUSTIBLE F
11//22
”, DEPTH 17”, WIDTH 34”. THE M”, DEPTH 17”, WIDTH 34”. T
ISTANCE FROM THE BOTTOM OF A CO
45004500
MENTATION MENTATIO
/ALIMENTATION REDUITE ALIMENTATION REDUI
E D’EAUE D’EA
:AFUE:
% 72.4%
M
:MANIFOLD P
10
PRESSION AU COLLECPRESSION
MINIMUM SUPPLY PRMINIMUM SU
PRESSION D’ALIMRESSION D’A
MAXIMUM SUPPIMUM SUP
PERSSION D’PERSSION D
:AFUE
72.44
TÉ DU FOYTÉ DU FO
RME AUX EXIGENCES DE LA NRME AUX EXIGENCES DE LA N
S MOBILES ÉQUIPÉES AU GAZ,
MAISONS MANUFACTURÉES, TITRE 2NUFACTURÉES, TITRE 2
OÙ CETTE NORME DES ÉTATS-UNIME DES ÉTATS-UN
RÉFÉRER À LA NORME RELATIVRME RELATIV
CONTRE L'INCENDIE POUR LECONTRE L'INCENDIE POUR L
MANUFACTURÉES, LES SITMANUFACTURÉES, LES SIT
recommendations from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft (304.8m). Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is not approved for closet or recessed installations. It is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile homes. The natural gas model is suitable for installation in a mobile home that is permanently positioned on its site and fuelled with natural gas.
2.5 RATING PLATE INFORMATION
7
EN
68.9%
XIR4-1
DO NOT TURN ON IF CHILDREN OR OTHER AT RISK INDIVIDUALS ARE NEAR THE FIREPLACE. DIRECT VENT GAS FIREPLACE HEATER. SUITABLE FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
CERTIFIED UNDER / HOMOLOGUÉ SELON LES NORMES: ANSI Z21.88b-2009, CSA 2.22b-2009 VENTED GAS FIREPLACE / APPAREIL À GAZ V E N T I L É S .
CERTIFIED
CERTIFIED FOR CERTIFIEE POUR
REFERENCE #161746
CANADA USA
Natural Gas/Gaz Naturel Propane
AFUE: 72.4%
AFUE
72.4
I
MODEL
MANIFOLD PRESSURE: 10” WATER COLUMN
ANIFOLD PRESSURE
PRESSION AU COLLECTEUR: 10” D’UNE COLONNE D’EAU MINIMUM SUPPLY PRESSURE: 11” WATER COLUMN PRESSION D’ALIMENTATION MINIMALE: 11” D’UNE COLONNE D’EAU MAXIMUM SUPPLY PRESSURE: 13” WATER COLUMN PERSSION D’ALIMENTATION MAXIMALE: 13” D’UNE COLONNE D’EAU AFUE: 72.4%
AFUE
CE FOYER À GAZ VENTILÉS NE DOIT PAS ÊTRE UTILISÉ CONJOINTEMENT AVEC DES FILTRES À AIR. UTILISER AVEC LES PORTES VITRÉES HOMOLOGUÉES AVEC CETTE UNITÉ SEULE­MENT. UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET APPAREIL.
AVERTISSEMENT: N'A JOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT
ENTRER EN CONTACT A VEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI A VEC CET APPAREIL PAR LE FABRICANT.
CLASS : 115V, 1.5AMP, 60HZ L’APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L’ENSEMBLE D’EVACUATION PROPRE A WOLF STEEL. REFERER AU MANUEL D’INSTALLATION DE PROPRIETAIRE POUR L’EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER ET RESCELLER L’EVENT APRES AVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D’AIR. ATTENTION : POUR INSTALLATION DANS UN FOYER VENTILE EN MACONNERIE. LES DIMENSIONS MINIMUMS SONT: HAUTER 24 1/2”, PROFONDEUR 17”, LARGEUR 34”. LE DIAMETRE INTERIEUR MINIMUM DE CONDUIT D’EVACUATION EST DE 6”. LA DISTANCE MINIMALE, DU BAS DU MANTEAU COMBUSTIBLE FORMANT UNE PROJECTION MAXIMALE DE 3” DU MUR AU DESSUS DE LA GARNITURE NORMALE EST 12”. REFERER AU MANUEL D’INSTALLATION POUR DES EXTENSIONS PLUS GRANDES. SOUFFLERIE OPTIONELLE
SERIAL NUMBER/NO. DE SERIE: XIR4/CXIR4
XIR4N XIR4PCXIR4N CXIR4P
PRESSION D’ALIMENTATION MINIMALE: 4.5” D’UNE COLONNE D’EAU
PERSSION D’ALIMENTATION MAXIMALE: 7.0” D’UNE COLONNE D’EAU
4500FT (0-1370m) ALTITUDE/ELEVATION 4500FT (0-1370m) 40,000 BTU/h INPUT/ALIMENTATION 40,000 BTU/h 16,000 BTU/h REDUCED INPUT/ALIMENTATION REDUITE 15,000 BTU/h
MANIFOLD PRESSURE: 3.5” WATER COLUMN
PRESSION AU COLLECTEUR: 3.5” D’UNE COLONNE D’EAU
MINIMUM SUPPLY PRESSURE: 4.5” WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 7.0” WATER COLUMN
THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS. FOR USE WITH GLASS DOORS CERTIFIED FOR THIS UNIT ONLY. NOT FOR USE WITH SOLID FUEL.
WARNING:
CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
ELECTRICAL RATING: 115V 1.5AMP 60HZ THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE OWNER’S INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM. WARNING: FOR INSTALLATION INTO A VENTED NON-COMBUSTIBLE FIREPLACE ONLY. THE MINIMUM FIREPLACE SIZE IS: HEIGHT 24 FLUE SIZE IS 6”. THE MINIMUM DISTANCE FROM THE BOTTOM OF A COMBUSTIBLE MANTEL PROJECTING A MAXIMUM 3” FROM THE WALL TO THE TOP OF THE UNIT IS 12”. SEE OWNER’S MANUAL FOR GREATER EXTENSIONS. OPTIONAL FAN KIT - GZ550-KT, GD65.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 4Y8 CANADA
DO NOT ADD ANY MA TERIAL T O THE APPLIANCE THAT WILL COME IN
1
/2”, DEPTH 17”, WIDTH 34”. THE MINIMUM INSIDE
THATWI
Y Y THE MAN
NE PAS ALLUMER SI DES ENFANTS OU D’AUTRES INDIVIDUS À RISQUE SONT À PROXIMITÉ DU FOYER. APPAREIL DE CHAUFFAGE À ÉVACUATION DIRECTE. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION EST CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE MAISONS MOBILES ÉQUIPÉES AU GAZ, EN VIGUEUR AU CANADA, OU AUX ÉTATS-UNIS, SELON LA NORME DE SÉCURITÉ ET DE CONSTRUCTION DE MAISONS MANUFACTURÉES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OÙ CETTE NORME DES ÉTATS-UNIS NE PEUT ÊTRE APPLIQUÉE, SE RÉFÉRER À LA NORME RELATIVE AU CRITÈRE DE MESURES DE SÉCURITÉ CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉES, LES SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A.
GZ550-KT, GD65.
W385-0662
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to the model, venting and gas type of the appliance.
For rating plate location, see “INSTALLATION OVERVIEW” section. This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
W415-1194 / 03.04.13
8
-
3.0 INSTALLATION
EN
!
WARNING
RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE.
Clean out ashes from the inside of the wood-burning appliance. Make sure that the chimney and wood-burning appliance are in a clean and sound condition and constructed of non-combustible materials. If necessary have any repair work done by a qualifi ed person before installing the insert. Remove the existing appliance damper or lock into an open position.
WARNING: THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIREPLACE
INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS ALL ORIGINAL
Using screws, attach the appliance warning tag to the inside of the fi rebox of the appliance into which the insert is being installed.
The sheet-metal parts of the appliance, in which the gas appliance insert is to be installed, must not be cut.
PARTS HAVE BEEN REPLACED AND THE FIREPLACE IS RE-APPROVED BY THE AUTHORITY HAVING JURISDICTION.
ATTENTION: CE FOYER A ETE CONVERTI AFIN D’ETRE UTILISE SEULEMENT
COMME FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE POUR BRULER DU BOIS OU TOUT AUTRE COMBUSTIBLE SOLIDE, SANS QUE TOUTES LES PIECES ORIGINALES AIENT ETE REMPLACEES ET QUE LE FOYER SOIT APPROUVE DE NOUVEAU PAR LES AUTORITES AYANT JURIDICTION.
ADVERTENCIA: ESTA CHIMENEA SE REMODELÓ PARA USARSE SOLO CON UNA
INSERCIÓN DE CHIMENEA A GAS Y NO PUEDE USARSE PARA QUEMAR MADERA NI COMBUSTIBLES SÓLIDOS, A MENOS QUE SE HAYAN REEMPLAZADO TODAS LAS PIEZAS ORIGINALES, Y LA AUTORI­DAD JURISDICCIONAL LA HAYA VUELTO A APROBAR.
W385-0199_B
If the wood-burning factory-built appliance has no gas access hole(s) provided, an access hole of 1½ inch (38.1mm) or less may be drilled through the lower sides or bottom of the appliance in a proper workman like manner. This access hole must be plugged with non combustible insulation after the gas supply line has been installed.
Ensure that existing chimney cleanouts fi t properly. The refractory, glass doors, screen rails, screen mesh and log grates may be removed from the existing
appliance before installing the gas appliance insert. Smoke shelves, shields and baffl es may be removed if attached by mechanical fasteners. The ventilation openings in the existing appliance may be obstructed by the backer plates, aluminium trim etc.
but these parts are not to be applied so as to have an airtight seal.
68.4B
3.1 LEVELLING THE APPLIANCE
Move the appliance close to its fi nal position. This appliance is equipped with levelling screws located on the base. Level using the levelling screws. Levelling the appliance will eliminate rocking or excessive noise when the fan is in operation. Once the appliance is level, move it partially into place to allow for all connections to be made. It is not practical to level the appliance once it has been installed. Determine the required depth prior to installing the appliance and adjust the levelling screws accordingly.
67.2
W415-1194 / 03.04.13
3.2 CHIMNEY CONNECTION
Chimney installation must conform to both national and local code requirements. The chimney must be lined with one 3" (76.2mm) diameter liner for intake and one 3" (76.2mm) diameter liner for exhaust. The minimum and maximum vent lengths are 10 feet (3.1m) and 35 feet (10.7m) respectively. Recommended kits come in 3 lengths:
2-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST:
GDI-320KT VENT KIT 20FT (6.1m)
GDI-325KT VENT KIT 25 FT (7.6m)
GDI-335KT VENT KIT 35 FT (10.7m)
While the liners must be continuous from the appliance to the chimney cap, to achieve the needed length, they may be coupled, using an approved coupler and sealant. We recommend that exhaust vents that pass through unheated spaces, such as tall exterior chimneys, be wrapped in a protective sleeve to minimize condensation and reverse fl ow symptoms. See Trouble Shooting for details. This appliance is approved for use with a 3" (76.2mm) exhaust and air intake.
A. OUTSIDE: Slip the one end of a liner a minimum of 2" (50.8mm)
over the sleeve of the air terminal. Secure using 3 screws. Then seal the joint and screw heads with high temperature sealant. Repeat with the other liner.
EXHAUST
INTAKE
9
EN
FLASHING PLATE
2” (50.8mm) OVERLAP
SEALANT HI-TEMP
NOTE: We recommend that the other end of the exhaust liner be marked to eliminate the
exhaust liner being connected to the intake collar at the appliance.
B. Gently stretch the liners to the
required lengths and insert into
3” (76.2mm)
LINERS
the chimney. Trim and t the ashing plate to suit the chimney
termination. Place the air terminal onto the top of the chimney. Make weather tight by sealing with caulking (not supplied). Fasten to the chimney with
HIGH TEMP
SEALANT
2” (50.8mm)
OVERLAP
SLIDER
MOUNTING
PLATE
screws and plugs (not supplied).
C. INSIDE: Remove the securing
screw from the front of the vent
INTAKE
VENT MOUNT
ASSEMBLY
mounting plate. Pull the vent mounting plate only, back into
EXHAUST
the track, to the front stop. Start the slider back into position. Re­secure the screw. The appliance may now be pushed into its nal position inside the wood burning appliance, and the screw tightened until the slider has been pulled tight to the front stop.
SECURING
SCREW
D. Route the fl ex liners through
the slider. Attach and secure the liners to the vent mounting plate using the same procedure as before, ensuring that the marked exhaust liner is attached to the exhaust collar.
W415-1194 / 03.04.13
10
3.3 GAS INSTALLATION
EN
!
WARNING
RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS
SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE.
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT
WITH THE GLASS DOOR OPENED OR REMOVED. PURGING OF THE GAS SUPPLY LINE SHOULD BE
PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. ASSURE THAT A CONTINUOUS GAS FLOW IS AT
THE BURNER BEFORE CLOSING THE DOOR. ENSURE ADEQUATE VENTILATION. FOR GAS AND
ELECTRICAL LOCATIONS, SEE “DIMENSION” SECTION.
ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE.
HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE TESTING GAS
LINE AT TEST PRESSURES ABOVE 1/2 PSIG.
VALVE SETTINGS HAVE BEEN FACTORY SET, DO NOT CHANGE.
Installation and servicing to be done by a qualifi ed installer. Do not use open ame.
Move the appliance into position and secure.
If equipped with a fl ex connector the appliance is designed to accept a 1/2” gas supply. Without the connector it is designed to accept a 3/8” gas supply. The appliance is equipped with a manual shut off valve to turn off the gas supply to the appliance.
Connect the gas supply in accordance to local codes. In the absence of local codes, install to the current CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United States.
• When fl exing any gas line, support the gas valve so that the lines are not bent or kinked.
Check for gas leaks by brushing on a soap and water solution.
SPARKS OR OPEN FLAMES.
30.1
W415-1194 / 03.04.13
4.0 FINISHING
11
RISK OF FIRE!
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT GO
BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED.
DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS
REMOVED, CRACKED, BROKEN OR SCRATCHED.
FACING AND/OR FINISHING MATERIAL MUST NEVER OVERHANG INTO THE APPLIANCE OPENING.
4.1 MINIMUM MANTEL CLEARANCES
!
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE
CLEARLY MAINTAINED.
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
HEAT RESISTANT TO PREVENT DISCOLOURATION.
Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed. These same requirements apply to any combustibles protruding on either side of the appliance.
!
WARNING
WARNING
EN
72.1A
73.1
0
$ 1 7 (
/
+ (
* +
7
MANTEL DIMENSIONS
Ref
A 17" (431.8mm) B 16" (406.4mm) C 15" (381mm) D 14" (355.6mm) E 6" (152.4mm) F 5" (127mm) G 4" (101.6mm) H 3" (76.2mm)
A
B
,
C
D
6” (152.4mm) MANTEL
F
G
H
A
B
C
D
241/4” (616mm)
0” (mm)
H
G
MANTEL DEPTH
F
E
W415-1194 / 03.04.13