Napoleon VECTOR LHD45 Quick Start Manual

VECTORTM 45 DIRECT VENT GAS FIREPLACE
Specifications
Model BTU
LHD45 24,000 46 1/4 46 3/4 40 13/16 41 1/4 19 7/8 20 1/8 17 13/16 x 40 7/8
Width Height Depth
Actual Framing Actual Framing Actual Framing
Glass
Overview
Dimensions
Mantel, see “MINIMUM MANTEL CLEARANCES” section.
Framing, see “FRAMING” section.
Side Wall
Enclosures, see the section “MINIMUM CLEARANCES TO COMBUSTIBLE ENCLOSURES” section for drywall (or other combustible material).
SAFETY BARRIER
Rating plate, see “RATING PLATE INFORMATION” section.
Venting, see “VENTING” section.
Framing, see “FRAMING” section.
Enclosures, see the section “MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES” section for non-combustible materials such as tile, marble, granite, etc.
SAFETY BARRIER
24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8
Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com
39 5/16" 999mm
452mm
7 1/2"
191mm
10 1/8" 257mm
GAS INLET
18 7/8" 479mm
19 7/8" 505mm
34 1/16" 865mm
46 1/4"
1175mm
Ø
7"
178mm
Ø
4"
102mm
05/2015
VECTOR
45 DIRECT VENT GAS FIREPLACE
Framing & Clearances
Minimum Fireplace Clearances Framing Dimensions
DO NOT BUILD INTO THIS AREA - IT MUST BE LEFT CLEAR TO PROVIDE ADEQUATE CLEARANCE
FOR THE VENT IN THIS 14” (356mm) WIDE AREA CENTERED ALONG THE FRONT OF THE
FIREPLACE. NO COMBUSTIBLES ARE ALLOWED. FIREPLACE SHOULD BE IN ITS FINAL LOCATION
56"
1422mm
MINIMUM FROM BASE
OF APPLIANCE
41 1/4"
TM
Appliance Location
OUTSIDE
CHASE
1187mm
46 3/4"
20 1/8" 511mm
1187mm
46 3/4"
Wall Penetration
18 3/16" 462mm
30 11/16" 780mm
MIN 56 "
1422mm
MINIMUM
ENCLOSURE
HEIGHT
12 1/2" 317mm
TOP OF FIREPLACE OPENING
25 5/16" 643mm
MIN
VENT HEAT SHIELD
2"
14"
NON-COMBUSTIBLE
356mm
MATERIAL
51mm
INSIDE CHASE
20 1/8" 511mm
51mm
2"
COMBUSTIBLE
SHELF
6"
1"
25mm
152mm MIN
52"
1320mm
1187mm
46 3/4"
BACK WALL OF CHASE / ENCLOSURE (INCLUDING ANY FINISHING MATERIAL)
73 1/2"
1867mm
MIN
NON-COMBUSTIBLE
2"
51mm
0” (0mm) IF NON­COMBUSTIBLE FINISHING IS USED SUCH AS BRICK AND STONE
1"
25mm
45 13/16" 1164mm
MIN PLUS
RISE*
Minimum Vertical Vent Rise
Combustible Mantel Clearances
1048mm
46 3/4"
1187mm
!
WARNING
BEFORE FRAMING.
14"
356mm MIN
20 1/8" 511mm *
Product information provided is not complete and is subject to change without notice. Please consult the installation manual for the most up to date installation information.
24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 • 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8
Fireplaces, Heating and Cooling: 705-721-1212 • Grills: 705 726-4278 • napoleonproducts.com
05/2015
Loading...