![](/html/d2/d29c/d29c16273ab1890ac8af092f7e445dcc62c241e96d753045ca1e81f029ace4fb/bg1.png)
REPORT NUMBER: G100253851MID-007r1
REPORT DATE: October 29, 2010
REVISED REPORT DATE: November 3, 2010
EVALUATION CENTER
Intertek Testing Services NA Inc.
8431 Murphy Drive
Middleton, WI 53562
RENDERED TO
Wolf Steel Limited
24 Napoleon Road
Barrie, ON L4M 4Y8
Canada
PRODUCT EVALUATED:
MODEL NAPOLEON TPS35 WOOD PELLET FUELED ROOM HEATER
TEST REPORT
Report of Testing Model TPS35 Pellet-Fuel Room Heater for compliance with
the applicable requirements of the following criteria: EPA Method 28
“Certification and auditing of wood heaters” and Method 5G Determination
of particulate matter emissions from wood heaters.”
This report is for the exclusive use of Intertek's Client and is provided pursuant to t he agreement between Intertek and its Client.
Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liab ility to any
party, other than to the Client in accordance with the agreem ent, for any loss, expense or damage occasioned by the use of this
report. Only the Client is authorized to copy or distribute this report and then only in i ts entirety. Any use of the Interte k name or
one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by
Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply
that the material, product, or service is or has ever been under an Intertek certification program.
1
![](/html/d2/d29c/d29c16273ab1890ac8af092f7e445dcc62c241e96d753045ca1e81f029ace4fb/bg2.png)
Wolf Steel Limited Date: November 3, 2010
Project No. G100253851 Page 7 of 15
II.D SUMMARY OF OTHER DATA
EMISSIONS
Run
Number
Test
Date
Burn Rate
(kg/hr)
Emission Rate
(g/hr)
Adjusted
Emission Rate
(g/hr)
1 10/25/10 0.661 4.400 6.224
2 10/25/10 1.688 0.985 1.797
3 10/26/10 2.166 1.024 1.856
4 10/26/10 0.612 3.345 4.958
WEIGHTED AVERAGE CALCULATION
Test No. Burn Rate
(E)
Average
Emission
Rate g/hr
Heat
Output
(Btu/hr)
Probability
(K)
Weighting
Factor
(KxE)
1 0.661 6.224 7970.47 0.1274 0.7314 4.5520
2 1.688 1.797 20354.24 0.8364 0.8059 1.4482
3 2.166 1.856 26118.06 0.9333 0.1636 0.3036
4 0.612 4.958 7379.62 0.1050 0.1274 0.6316
Totals: 1.82824 6.9354
Weighted average emission rate: 3.7935
TEST FACILITY CONDITIONS
Run
Room
Temp.
°F
before
Room
Temp
°F
after
Baro.
Pres.
In. Hg
before
Baro.
Pres.
In. Hg
after
R.H.
%
before
R.H.
%
after
Air
Vel.
Ft/min
before
Air
Vel.
Ft/min
after
1 77 80 28.56 28.57 21 21 0 0
2 80 80 28.57 28.52 21 21 0 0
3 75 79 27.91 27.96 21 21 0 0
4 79 79 27.96 28.06 21 21 0 0
DILUTION TUNNEL FLOW RATE MEASUREMENTS AND SAMPLING DATA
(5G-3)
Particulate
Catch (mg)
Run
No.
Burn
Time
(min)
Velocity
(ft/sec)
Volumetric
Flow Rate
(dscf/min)
Total
Temp.
(oR)
Sample
1 2 1 2
1 120 13.39 139.31 547.43 27.54 27.75 14.6 14.5
2 120 12.24 121.86 571.99 27.16 27.04 3.8 3.5
3 120 13.41 131.25 569.11 26.66 27.18 3.5 3.5
4 120 13.08 132.39 551.93 26.49 26.71 11.3 11.1