Napoleon Split Type Wall-mounted Inverter Room AC, Split Type Wall-mounted Inverter Room Air Conditioner User Manual

The des ign and spec ifi catio ns are subject to cha nge w ithou t pr ior n oti ce fo r pro duct im pr ove men t. Cons ul t w ith t he sa le s agency or ma nufa ctur er f or de tai ls.
Thank you very much for purchasing our air conditioner.
11 22
DISPOSAL: Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
When using this air conditioner in the European countries, please read the following information:
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
CONTENTS
SAFETY PRECAUTIONS
NAMES OF PARTS
OPERATING INSTRUCTIONS
CARE AND MAINTENANCE
TROUBLESHOOTING TIPS
Warning .....................................................................................................................................3
Caution ......................................................................................................................................4
.
Indoor unit ........... .....................................................................................................................5
outdoor unit ...............................................................................................................................5
Indication lamp...........................................................................................................................5
Special functions .......................................................................................................................6
Operating temperature................................................................................................................7
Manual operation ......................................................................................................................7
Airflow direction control ............................................................................................................8
How the air conditioner works ..................................................................................................9
Before maintenance...... ...........................................................................................................10
Cleaning the unit.......................................................................................................................10
Cleaning the air filter and air freshening filter ..........................................................................10
Replacement of the air filter and air freshening filter ...............................................................11
Preparation for extended non-operation....................................................................................11
Pre-season inspection...............................................................................................................11
Normal function of the air conditioner.......................................................................................12
Troubleshooting guide .............................................................................................................14
33
44
SAFETY PRECAUTIONS SAFETY PRECAUTIONS
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
Meanings of symbols used in this manual are as shown below.
WARNING
Be sure to follow the instructions.
Strictly prohibited.
CAUTION
This symbol indicates the possibility of injury or damage to property.
Do not extend the cable and never use multiple plugs. A poor electrical connection, poor insulation or voltage which is higher than permitted can cause fire. Do not expose your body directly to the cool air for prolonged period. Never poke fingers, sticks or other objects in the air inlet and outlet vents. Never attempt to repair, relocate, modify the air conditioner yourself. Always contact your service partner if it requires. Never pull the plug out by pulling on the cable. Hold the plug firmly and pull it out of the plug socket, otherwise there is a risk of damaging the cable.
Do not operate your air conditioner in a wet
room such as a bathroom or laundry room.
Never actuate any switches with a wet hand. It may cause an electric shock. Never use the device for any other purpose than the intended use. Never place food, precision instruments, plants, animals, paint, etc. on the unit. Do not expose plants or animals directly to the air flow. Never clean the air conditioner with water. Never use combustible cleaning agents as these could cause a fire or deformation. Never place any burning objects close to the device if they could be directly affected by the emitted air. Never step onto the outdoor device and never place anything on it. Never use an unsteady or rusty base. Never install the air conditioner in places where combustible gas can be emitted. Emmitted gas may collect and cause an explosion. Never allow the air conditioner to run for too long with the doors or windows open, or if the humidity is very high.
Remove all dirt from the power plug and plug it firmly. Soiled plugs can cause fire or an electric shock. In the event of any abnormalities such as smell of burning, immediately switch off the device and pull the plug. Contact your service partner. Always switch off the device and pull the plug before you start to clean it. Use specified power cord.
Contact the authorized installer for installation of this unit. Contact an authorized service technician for repair or maintenance of this unit. This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the air conditioner.
If the air conditioner is to be used in conjunction with other heaters, the air should be refreshed periodically, otherwise there is a risk of lack of oxygen. Always pull out the power plug if the unit is not going to be used for any lengthy period of time. Collections of dust can cause fire. Always switch off the air conditioner and pull out the power plug during a storm. Electrical parts may get damaged. Check that the drainage line is correctly connected. If not, water will escape. Check that the condensation water can run off unhindered. It may cause water damage if the condensation water cannot run off properly. The air conditoner must be earthed in accordance with the local codes. For electrical safety purposes we recommend that you install an earth­ leakage circuit-breaker.
If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similary qualified persons in order to avoid a hazard.
WARNING
CAUTION
55
66
OPERATING INSTRUCTIONS
Special functions
Improving the quality of indoor air is one of the purposes of an air conditioner. This air conditioner is equipped with ionizer or Plasma Dust Collector(Depending on specific configuration of the model). With the anions generated by Ionizer, the air circulation of the air conditioner fills the room with refreshing, natural and healthy air. The Plasma Dust Collector generates a high voltage ionization zone, through which the air is converted to plasma. Inside the air most of the dust, smoke, and pollen particles are captured by the electrostatic filter.
CLEAN AIR function(on some models)
SELF CLEAN function Optional
Function used after the Shut Down of cooling operation to clean the Evaporator and keep it as fresh for the next operation. The unit will operate as following sequence : FAN ONLY mode at Low fan speed--Heating operation with LOW fan speed(applicable to cooling & heating modles only) ---FAN ONLY operation--Stop Operation---Turn off. Note: This function is only available under COOL(AUTO COOL, FORCED COOL) and DRY mode. Before select the function, it is recommended to run the air conditioner under Cooling operation for about half an hour. Once the Self Clean function is activated, all TIMER setting will be cancelled. During Self Clean operation, when press the SELF CLEAN button on the remote controller again will stop the operation and turn off the unit automatically.
Louver Angle Memory Function(optional):
Within the scope of safety angle, it will memorize the open angle of horizontal louver. If it exceeds, it will memorize the boundry of safety angle. In the following circumstances, it will return to standard angle: 1) pressing the manual control button, 2)unplug and then plug in the machine. So we strongly suggest that the open angle of the horizontal
louver should not be set too small, in case the condensed water forms and drops from the horizontal louver.
Refrigerant Leakage Detection
With this new technology, the dipsplay area will appear EC and the indication lamps continue flashing when the outdoor unit detects refrigerant leakage.
,
,
NAMES OF PARTS
8. Connecting pipe
9. Connecting cable
10. Stop valve
Outdoor unit
Indication lamp
NOTE:
All the pictures in this manual are for explanation purposes only. The actual shape of the indoor unit you purchased may be slight different on front panel and display window.The actual shape shall prevail.
Air inlet(rear)
Air inlet(side)
Air outlet
1. Front panel
2. Air inlet
3. Air filter
4. Air outlet
5. Horizontal air flow grille
6. Vertical air flow louver(inside)
7. Display panel
Indoor unit
OPERATION indication lamp
This lamp illuminates when the air conditioner is in operation.
TIMER indication lamp
Lights up during Timer operation.
DEFROST indication lamp
(Enabled on cooling & heating models only):
Lights up when the air conditioner starts
defrosting automatically or when the warm air control feature is activated in heating operation.
Names of parts
4
3
5
2
6
1
9
10
8
7
Signal receiver
A
B
Signal receiver
Temperature indicator
Displays the temperature settings when the air conditioner is operational. Displays the malfunction code.
Anti-mildew function Optional
When turns off the unit on COOL, DRY, AUTO (Cool) mode, the air conditioner will continue operating for about 7-10 minutes (depending on models) at LOW fan speed. If turns off on HEAT mode, the unit will continue operating for about 30 seconds at LOW fan speed. This will help to dry up the condensed water inside the evaporator, and prevent the breeding of mildew. Under Anti-mildew operation, do not restart the air conditioner until the unit is completely off.
77
88
OPERATING INSTRUCTIONS
Airflow direction control
Adjust the air flow direction properly, otherwise it might cause discomfort or cause uneven room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually.
To set the vertical air flow(Up--Down) direction Perform this function while the unit is in operation. Use the remote controller to adjust the air flow direction. The horizontal louver can be moved at
O
a range of 6 for each press, or swing up and down automatically. Please refer to the REMOTE CONTROLLER OPERATION MANUAL for details.
To set the horizontal air flow direction (left - right)
Move the deflector rod manually to adjust the air flow in the direction you prefer. IMPORTANT:Do not put your fingers into the panel of blower and suction side.The high-speed fan inside may
cause danger.
Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dehumidifying mode. Otherwise, condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings. When the air conditioner is started immediately after it was stopped, the horizontal louver might not move for approximately 10 seconds. Open angle of the horizontal louver should not be set too small, as COOLING or HEATING performance may be impaired due to too restricted air flow area. Do not move the horizontal louver manually, otherwise the horizontal louver will be out of sync. Please cease operating, unplug power for a few seconds,then restart the air conditioner.
CAUTION
,,
,,
OPERATING INSTRUCTIONS
Manual operation
NOTE: This manual does not include Remote Controller Operations, see the <<Remote Controller Instruction>> packed with the unit for details.
Operating temperature
Manual switch
Manual switch
Range
Range
Deflector rod
AUTO/COOL
Suspension bars
AUTO/COOL
1
2
Mode
Temperature Room temperature
Outdoor temperature
1. Optimum performance will be achieved within these operating temperatures.If air conditioner is used outside of the above conditions, certain safety protection features might come into operation and cause the unit to function abnormally.
2. If the air conditioner runs for a long time in cooling mode and the humidity is high(over 80%) , condensed water may drip out of the unit. Please sets the vertical air flow louver to
its maximum angle (vertically to the floor), and set HIGH fan mode. Suggestion: For the unit adopts an Electric Heater, when the outside ambient temperature
OO
is below 0 C(32 F), we strongly recommend you to keep the machine plugged in order to guarantee it running smoothly.
NOTE:
Cooling operation
Heating operation Drying operation
-15 50 5 122
For the models with low
temperature cooling system
0 50
32 122
-15 30 5 86
0 50
32 122
Open and lift the front panel up to an angle until it remains fixed with a clicking sound. For some models, please use suspension bars to prop up the panel.
One press of the manual control switch will lead to the forced AUTO operation. If press the switch twice within five seconds, the unit will operate under forced COOL operation. Close the panel firmly to its original position.
This switch is used for testing purposes only. You had better not choose it. To restore the remote controller operation, use the remote controller directly.
CAUTION:
1
3
2
NOTE: The unit must be turned off before operating the manual control button. If the unit is operational, continue pressing the manual control button until the unit is off.
OO
17 C~32 C
OO
(62 F~90 F)
OO
0 C~30 C
OO
(32 F~86 F)
OO
10 C~32 C
OO
(50 F~90 F)
Units are equipped with a switch to run emergency operation mode. It can be accessed by opening the front panel. This switch is used for manual operation in case the remote controller fails to work or maintenance necessary.
99 1010
CARE AND MAINTENANCE
OPERATING INSTRUCTIONS
How the air conditioner works
1 hour
1 hour
Set Temperature
Set Temperature
Cooling
Heating
SLEEP operation
1 hour
1 hour
SLEEP operation
7 hours timer off
7 hours timer off
AUTO operation
When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling/heating models only), or fan only operation depending on set temperature and the room temperature. The air conditioner will control room temperature automatically to the temperature point you set. If you feel uncomfortable in the AUTO mode, you can set your desired temperature.
SLEEP operation
When you push SLEEP button on remote controller during cooling, heating(cooling & heating models only), or AUTO operation , the air conditioner will automatically increase (cooling) or decrease (heating) per hour for the first 2 hours, then hold steadily for the next 5 hours, after that it will switch off. This mode saves you energy and brings you comfort at night.
DRYING operation
Optimal operation
To achieve optimal performance, please note the following: Adjust the air flow direction correctly so that it is not forwards people. Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels. Close doors and windows on COOL or HEAT modes, or performance may be reduced. Use TIMER ON button on the remote controller to select a time you want to start your air conditioner. Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be reduced and the air conditioner may stop running. Clean the air filter periodically, otherwise cooling or heating performance may be reduced. Do not operate unit with horizontal louvre in closed position.
The fan speed will be automatically controlled under dry operation. During the dry operation, if the room temperature is
OO
lower than 10 C(50 F), the compressor stops operation and restarts until the room temperature is above
OO
12 C(54 F).
Before mainatenance
A cloth dampened with cold water may be used on the indoor unit if it is very dirty. Then wipe it with a dry cloth. Do not use a chemically treated cloth or duster to clean the unit. Do not use benzine, thinner, polishing powder, or similar solvents for cleaning. These may cause the plastic surface to crack or deform. Never use water hotter than 40 C/104 F to clean the front panel, it could cause deformation of discoloration.
CAUTIONS
Care and Maintenance
Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.
NOTE: Power supply must be disconnectd before cleaning the indoor unit.
Filter Handle
Cleaning the unit
wipe the unit with a soft dry cloth only. If the unit is very dirty, wipe it with a cloth soaked in warm water.
Cleaning the air filter and air freshening filter
A clogged air filter reduces the cooling efficiency of this unit. Please clean the filter once every 2 weeks.
1. Lift the indoor unit panel up to an angle until it stops with a clicking sound.For some models, please use suspension bars to prop up the panel.
2. Take hold of the handle of the air filter and lift it up slightly to take it out from the filter holder, then pull it downwards.
3. Remove the AIR FILTER from the indoor unit. Clean the AIR FILTER once two weeks. Clean the AIR FILTER with a vacuum cleaner or water, then dry it up in cool place.
4. Remove the Air Freshening Filter from its supporting frame (on some models). Clean the air freshening filter at least once a month, and replace it every 4-5 months. Clean it with vacuum cleaner, then dry it in cool place.
Air freshening filter
Loading...
+ 13 hidden pages