PATIO HEATER
Natural Gas
WARNING: For Outdoor Use Only.
FOR YOUR SAFETY
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. If odor continues ,immediately
call gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or
other flammable vapors or liquids
in the vicinity of this or any other
appliance.
CAUTION: Retain the instructions
for future use.
I
S
G
E
N
D
CERTIFIED
C
D
E
E
R
I
T
F
I
Model No.:SRPHN02
Master Contract No.:217109
Customer Item No.: PTHC38NK
Manual,Instructions & Parts List
TOOLS AND PARTS NEEDED FOR ASSEMBLY
TOOLS AND PARTS NEEDED FOR ASSEMBLY
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause injury, death or
property damage.
Read the installation, operating and
maintenance instructions thoroughly
before installing or servicing
this equipment.
WARNING
For outdoor use only.
Storage indoors is permissible only if the
natural gas is disconnected.
The unit should be secured or moved indoors
if winds exceed 35 km/h.
TOOLS NEEDED:
7/16 Wrench
3/8 Open End Wrench
Adjustable Opening Wrench, 8 Long
Philips Head Screwdriver
Leak Detection Solution ( Instructions how to make solution are included in Step 10 )
For questions, replacement parts, service help, or other assistance, please
call SHINERICH at: 86- 755-26930633 or local Shinerich dealer .
2
1 Centre Reflector Cap
1
4 Reflector Cap
2
1 Head Assembly
3
1 Upper Post
4
1 Mid Post
5
1 Lower Post
6
1 Base
7
4 M8 x55 Bolts
8
4 8mm Washers
9
4 8mm Spring Washers
10
4 M8 Nuts
11
15 M6 Nuts
12
18 6mm Washers
13
12 M6x10 Bolts
14
3 M6x70 double pointed bolts
15
PA RT S
12
13
1
2
14
15
3
16
16
8
9
11
14
15
1 Gas Hose
10
12
13
8
10
4
5
6
7
9
11
7
3
NOTE: PLEASE READ THE FOLLOWING SAFETY RULES
WARNING
This appliance must only be used outdoors.
Using this product in an enclosed area may cause
injury, death or property damage.
Read the instructions before use.
This appliance must be installed in
accordance with such regulations as
are in force.
Do not use the heater in an explosive atmosphere.
Keep the heater away from areas where gasoline or other
flammable liquids or vapors are stored.
Prior to use, check for damaged parts such as gas hoses,
natural gas pipe, pilot or burner.
The installation of fixed appliances shall only be carried out
by competent persons and be in accordance with local codes
or in the absence of local codes, with the national fuel gas code
ANSI Z223.1 in the USA or the CSA B149.1 natural gas and
propane installation code in Canada. The manifold pressure and
minimum inlet supply pressure is 7.0 inches water column.
The maximum supply pressure is 10.5 inches water column.
The appliance and its individual shut off valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess
of 0.5 PSIG (3.5 KPA).
The appliance must be isolated from the gas supply piping
system by closing its individual manual shut off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 0.5 PSIG (3.5 KPA).
Always assure there is ample fresh air ventilation.
For outdoor use ONLY.
Do not clean the heater with cleaners that are combustible
or corrosive.
Do not paint radiant screen, control panel or top canopy
reflector.
All leak tests should be done with a soapy solution. NEVER
USE AN OPEN FLAME TO CHECK FOR LEAKS.
The natural gas should be turned off when the heater is
not in use.
At least once a year, the unit should be inspected for the
presence of spiders, spider webs or other insects. Check the
heater immediately if any of the following exist:
1. The smell of gas in conjunction with extreme yellow
colored tips of the burner flames.
2. The heater does not reach temperature.
3. The burner makes popping noise during use (a slight
popping noise is normal when the burner is extinguished
after using).
The natural gas hose assembly shall be located out of
pathways where people may trip over it or in areas
where the hose will not be subject to accidental damage.
Children and adults should be aware of the hazards of high
surface temperature and shall stay away to avoid burns or
clothing ignition.
PRECAUTIONS
Warning: This appliance requires a gas hose and natural
gas pipe, check with your gas supplier and or product supplier.
Regularly check the gas hose and natural gas pipe,
if necessary, replace the gas hose or natural gas pipe.
DISCONNECT Natural Gas before moving the heater.
Do not attempt to alter unit in any manner.
EXAMPLE: using the heater without the top canopy
reflector or radiant screen.
Do not shorten the burner post assembly.
The appliance shall not be used in basements or below
ground level.
It must always be placed on a solid and level surface.
Young children should be carefully supervised when they
are in the area of the heater.
Clothing or other flammable material should not be hung
from the heater, or placed on or near the heater.
Installation and repair should be done by a qualified
service person. The heater should be inspected before
use and cleaning may be required at least once a year, or as
necessary. It is imperative that control compartment, burner
and circulating air passageways of the heater be kept clean.
Keep the appliance area clear of combustible materials
such as gasoline and other flammable vapors and liquids.
Do not obstruct the flow of combustion and ventilation air.
4
WARNING:
TO BE INSTALLED ONLY BY AN
AUTHORISED PERSON
ASSEMBLY FOR LIGHT SYSTEM
Instruction For Battery Installing
Upon first time use of the product,please remove the
ignition button and install an AA battery as indicated.
Ignition button
Control knob
Replace Battery
Ignition button
AA battery
5
NOTE: Assembly of this heater requires
basic mechanical skills. Proper assembly
is the responsibility of the installer.
ASSEMBLY
Step 1
Step 1 ----
Attach lower post to base
Place the lower post on the top of
base.Then connect them
using 4pcs M8*55 bolts,4pcs 8mm
washers,4pcs 8mm spring washers
and 4pcs M8 nuts
Step 2 ----
Turn the mid post clockwise to the
Lower post as illustrated until tighten
them securely.
Assembly for lower post
Attach mid post to lower post
Step 2
8
10
6
7
9
11
5
6
6