SAFETY INFORMATION
NATURAL GAS
1
!
WARNING
If the information in these instructions are
not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbour’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certifi ed kit is used.
GSST8P
PROPANE
WARNING: FOR OUTDOOR USE ONLY
!
WARNING
HOT GLASS WILL CAUSE
BURNS.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
NOTE: Changes, other than editorial, are denoted by a line in the margin.
W415-0689 / C / 06.13.12
1.0 INSTALLATION OVERVIEW
Door, see “DOOR
REMOVAL” section.
3
Cabinet, see “MOUNTING
CABINET INSTALLATION”
section.
Glass, see “DOOR GLASS
REPLACEMENT” section.
Frame, see “FRAMING” section.
Rating plate, see “RATING PLATE
INFORMATION” section.
W415-0689 / C / 06.13.12
4
2.0 INTRODUCTION
• THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.
• Do not operate appliance before reading and understanding operating instructions. Failure to operate
appliance according to operating instructions could cause re or injury.
• Any changes to this appliance or its controls can be dangerous and is prohibited.
• Risk of burns. The appliance should be turned off and cooled before servicing.
• Do not install damaged, incomplete or substitute components.
• Risk of cuts and abrasions. Wear protective gloves and safety glasses during installation. Sheet metal
edges may be sharp.
• Do not burn wood or other materials in this appliance.
• Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing
and operating the appliance. Never obstruct the front opening of the appliance.
• If appliance keeps shutting off, have it serviced. Keep burner and control compartment clean.
• Do not allow wind to blow directly into the appliance. Avoid any drafts that alter burner ame patterns.
• Children and adults should be alerted to the hazards of high surface temperature and should stay away
to avoid burns or clothing ignition.
• Young children should be carefully supervised when they are in the same area as the appliance.
Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier
is recommended if there are at risk individuals in the vicinity of the appliance. To restrict access to an
appliance, install an adjustable safety gate to keep toddlers, young children and other at risk individuals
away from hot surfaces.
• Clothing or other ammable material should not be placed on or near the appliance.
• Furniture or other objects must be kept a minimum of 4 feet away from the front of the appliance.
• Ensure you have incorporated adequate safety measures to protect infants/toddlers from touching hot
surfaces.
• Even after the appliance is off, it will remain hot for an extended period of time.
• Check with your local hearth specialty dealer for safety screens and hearth guards to protect children
from hot surfaces. These screens and guards must be fastened to the oor.
• Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.
• It is imperative that the control compartments, burners and circulating blower and its passageway in
the appliance and venting system are kept clean. The appliance should be inspected before use and
at least annually by a quali ed service person. The appliance area must be kept clear and free from
combustible materials, gasoline and other ammable vapors and liquids.
• Under no circumstances should this appliance be modi ed.
• Do not use this appliance if any part has been under water. Immediately call a quali ed service
technician to inspect the appliance and to replace any part of the control system and any gas control
which has been under water.
• Keep the packaging material out of reach of children and dispose of the material in a safe manner. As
with all plastic bags, these are not toys and should be kept away from children and infants.
• This appliance must not be installed indoors or within any structure that prevents or inhibits the exhaust
gases from dissipating in the outside atmosphere.
!
WARNING
3.14A
W415-0689 / C / 06.13.12
2.1 DIMENSIONS
5
7 9/16”
49 11/16”
ELECTRICAL
ACCESS
6 ”
GAS LINE
ACCESS
2.2 GENERAL INSTRUCTIONS
ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT,
WITH THE GLASS DOOR OPENED OR REMOVED.
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48” FROM THE
FRONT FACE OF THE APPLIANCE.
HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE
TESTING GAS LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE
BEFORE PRESSURE TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG.
USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH
THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS
COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL
VOID THE WARRANTY AND CERTIFICATION.
THE APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE.
THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES.
1 ½”
!
WARNING
FIRE RISK. EXPLOSION HAZARD.
15”
13”
W415-0689 / C / 06.13.12
6
THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to
conform with local codes. Installation practices vary from region to region and it is important to know the
speci cs that apply to your area, for example in Massachusetts State:
• The appliance off valve must be a “T” handle gas cock.
• The exible connector must not be longer than 36 inches.
The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States.
2.3 GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ENSURE ITS OPERATION
AND QUALITY!
Altitude0 - 4,500*0 - 4,500*
Maximum Input6,0006,000
Minimum Inlet Gas Supply Pressure4.5” Water Column11” Water Column
Maximum Inlet Gas Supply Pressure7” Water Column13” Water Column
Manifold Pressure Under Flow Conditions3.5” Water Column10” Water Column
www.ncertied.org
RATES AND EFFICIENCIES
NATURAL GASPROPANE GAS
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certied in the U.S.
by the National Fireplace
®
Institute
(NFI) as NFI Gas
Specialists
4.3A
When the appliance is installed at elevations above 4,500ft, and in the absence of speci c recommendations
from the local authority having jurisdiction, the certi ed high altitude input rating shall be reduced at the rate of
4% for each additional 1,000ft.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certi ed kit is used.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
Purge all gas lines with the glass door of the appliance removed. Ensure that a continuous gas ow is at the
burner before replacing the door.
Objects placed in front of the appliance must be kept a minimum of 48” from the front face of the unit.
Use only authorized accessories designed for and listed with the model.
W415-0689 / C / 06.13.12
2.4 RATING PLATE INFORMATION
EGULATOR, ITMUSEGULATOR, IT MU
NE OR OTHER FLAMMABL
S MANUAL PROVIDED WITH THS MANUAL PROVIDED WITH T
TITUDETITUDE
T
TERT
COLUMCOLUM
C
COLUM
COLUMCOLUM
OO
ME IN CONTACT WITH THEME IN CONTACT WITHTHE
BACKCK
FLOOR FLOOR
& BACK AS PER ABOVE. FOR& BACK AS PER ABOVE. FO
SEE OWNERS MANUAL.
RATING LABEL LOCATION: THE RATING LABEL IS LOCATED UNDER THE CONTROL PANEL AND IS
CHAINED TO THE APPLIANCE. DO NOT REMOVE.
CERTIFIED UNDER : CGA CR97-003 (July, 1997) CSA US Req. 4-96, 3rd Ed. OUTDOOR GAS FIREPLACE
IF APPLIANCE HAS BEEN SUPPLIED WITH A GAS PRESSURE REGULATOR, ITMUST BE USED.
THE GAS SUPPLY MUST BE TURNED OFF AT THE LP-GAS SUPPLY CYLINDER WHEN THIS
APPLIANCE IS NOT IN USE. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. IMPROPER
APPLIANCE, WHICH WILL COME IN CONTACT WITH THE
FLAMES, OTHER THAN THAT SUPPLIED BY THE
MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
TOP 18” BACK 0”
SIDES 1” FLOOR 8”
TOP, SIDES & BACK AS PER ABOVE. FOR FINISHING
MATERIAL, SEE OWNERS MANUAL.
ELECTRICAL RATING: 115v 0.82AMP, 60HZ
INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE. REFER TO THE OWNER’S MANUAL PROVIDED WITH THIS
APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION, CONSULT AQUALIFIED
INSTALLER, SERVICE AGENCY OR GAS SUPPLIER. MUSTNOT BE USED FOR COOKING. FOR
OUTDOOR USE ONLY. IF STORED INDOORS, DETACHAND LEAVE CYLINDER OUTDOORS.
MODEL
GSST8N
(NATURAL GAS)(PROPANE)
0-4500FT (0-1370m)
6,000 BTU/h
MANIFOLD PRESSURE: 3.5" WATER COLUMN
ALTITUDE
A
I
P
INPUT
MANIFOLD PRESSURE: 10" WATER COLUMN
ANIFOLD
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
OLUM
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
NOT FOR USE WITH SOLID FUEL. FOR USE WITH
GLASS DOOR. CERTIFIED WITH THIS UNIT ONLY.
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE
OF GAS INDICATED ON THE RATING PLATE. THIS
APPLIANCE IS NOT CONVERTIBLE FOR USE WITH
OTHER GASES, UNLESS A CERTIFIED KIT IS USED.
WO LF S TE EL LTD .
24 NAPOLEON ROAD. BARRIE, ONTARIO L4M 0G8 CANADA
SERIAL NUMBER:
GSST8
MODEL
GSST8P
0-4500FT (0-1370m)
6,000 BTU/h
7
W385-0420 / E
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all time. It must not be removed.
W415-0689 / C / 06.13.12
8
3.0 INSTALLATION
3.1 INSTALLATION CLEARANCES
C
G
G
D
E
I
H
A
J
B
B
INSTALLATIONS
CANADAU.S.A.
A8 INCHES8 INCHESClearance above grade, veranda porch, deck or balcony.
B12 INCHES9 INCHESClearance to windows or doors that open.
C12 INCHES*12 INCHES*Clearance to permanently closed windows.
D18 INCHES**18 INCHES**Vertical clearance to ventilated sof t.
E12 INCHES**12 INCHES**Vertical clearance to an unventilated sof t.
F
K
F1 INCH1 INCH
G3 FEET3 FEET***
H3 FEET3 FEET***Clearance to a service regulator vent outlet.
I12 INCHES9 INCHES
J6 FEET 3 FEET**** Clearance to a mechanical air supply inlet.
K12 INCHES12 INCHES*** Clearance under a veranda, porch, deck or balcony.
* Recommended to prevent condensation on windows and thermal breakage.
** It is recommended to use a heat shield and to maximize the distance to vinyl clad sof ts.
*** This is a recommended distance. For additional requirements check local codes.
**** Three feet above if within 10 feet horizontally.
W415-0689 / C / 06.13.12
Clearance to an inside combustible corner wall or protruding
combustible obstructions. (vent chase, etc.)
Clearance to each side of the centre line extended above the metre/
regulator assembly to a maximum vertical distance of 15 ft.
Clearance to a non-mechanical air supply inlet to the building or a
combustion air inlet to any other appliance.
3.2 GAS INSTALLATION
ALL GAS CONNECTIONS MUST BE CONTAINED WITHIN THE APPLIANCE WHEN COMPLETE.
A.The appliance is designed to accept a 1/2” gas
supply line. The appliance is equipped with a 1/2”
manual shut-off valve.
B.The access to the gas inlet is located in the bottom
of the cabinet.
C.The shut off valve / ex connector assembly must
always be contained within the cabinet.
D.When exing any gas line, support the gas valve
so that the lines are not kinked.
E.Check for gas leaks by brushing on a soap and
water solution.
!
WARNING
DO NOT USE OPEN FLAME.
9
W385-0380
FLEX
CONNECTOR
SHUT OFF
VALVE
3.3 COMBUSTION AND VENTILATION AIR
!
WARNING
ENSURE THE AREA HAS ADEQUATE VENTILATION.
This appliance is intended for installation on an outdoor patio or in your yard. It must never be installed inside
the warm air envelope of your structure.
It is highly recommended that this appliance be installed in a “sheltered” area. Direct wind will cause an erratic
ame and possible pilot or main burner outage. An erratic ame could also lead to excessive carboning (black
soot), this condition is not a safety issue but is visually undesirable.
Typical installation may include covered patio, screened porch, gazebo, or on an outside wall of a house.