Napoleon GD40-N, GD40-P Installation And Operation Instructions Manual

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL ST ANDARDS, CSA-2.22 AND ANSI Z21.50 RESPECTIVELY FOR VENTED GAS FIREPLACE.
GAS FIRED - DIRECT VENT MILLIVOLT SYSTEM
INSTALLATION AND OPERATION INSTRUCTIONS FOR
MULTI-VIEW DECORATIVE FIREPLACE
1
NATURAL GAS MODEL PROPANE GAS MODEL
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / AGA / CGA METHODS
GD40-N GD40-P
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapours and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas suppli­er's instructions.
• If you cannot reach your gas supplier , call the fire department.
Installation and service must be performed by a qualified installer , service agency
or the gas supplier .
Wolf Steel Ltd., RR#1, 9 Napoleon Rd.,
Barrie, ON., Canada L4M 4Y8 (705)721-1212
Fax: (705)722-6031 Email: ask@napoleon.on.ca
Web: www.napoleon.on.ca
R-2000
WS-415-091 / 06.26.00
2
TABLE of CONTENTS
Pg 4-5 INTRODUCTION
Warranty General Instructions General Information Care of Glass & Plated Parts
6-10 VENTING
Vent Lengths Venting Options Mobile Home Installation Air Terminal Locations
11-12
PENINSULA INST ALLATION PROCE-
DURE
Framing Bar / Countertop Installation Brick Panel Installation Facing
13-14OPEN END INSTALLATION PROCE-
DURE
Framing Brick Panel Installation Facing
15
SEE-THRU INSTALLA TION PROCEDURE
Framing Brick Panel Installation Facing
PG 16-20 VENTING SPECIFICS
Horizontal Venting Installation Vertical Venting Installation Fireplace Vent Connection Gas Supply Connection
20-22FINISHING
Mantle Height Locations Log Placement/Charcoal Embers Door, Louvre & Trim Installation
2 3 OPTIONAL BLOWER INST ALLA TION 24 OPERATION / MAINTENANCE
Operating Instructions Maintenance
25 ADJUSTMENTS
Pilot Burner Adjustment Venturi Adjustments
25-28 REPLACEMENTS
Ordering Replacement Parts Replacement Parts Vent Kits Terminal Kits Accessories
29-30TROUBLE SHOOTING GUIDE 31 SERVICE HISTORY
PLEASE RET AIN THIS MANUAL FOR FUTURE REFERENCE
WARNING
• Do not burn wood or other materials in this fireplace.
• Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the fireplace.
• Due to high temperatures, the fireplace should be located out of traffic and away from furniture and draperies.
• Clothing or other flammable material should not be placed on or near the fireplace.
• Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace.
• It is imperative that the control compartments, burners and circulating blower and its passageway in the fireplace and venting system are kept clean. The fireplace and its venting system should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The fireplace area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids.
• Under no circumstances should this fireplace be modified.
• This fireplace must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.
• Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.
• Do not operate the fireplace with the glass door removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.
• Do not strike or slam shut the fireplace glass door.
WS-415-091 / 06.26.00
3
SEE-THRU MODEL
LEFT OPEN END MODEL
RIGHT OPEN END MODEL
PENINSULA MODEL
WS-415-091 / 06.26.00
4
NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized
ISO9002 Quality Assurance Certificate.
NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON.
NAPOLEON GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY
The following materials and workmanship in your new The following materials and workmanship in your new
The following materials and workmanship in your new
The following materials and workmanship in your new The following materials and workmanship in your new
ranted against defects for as long as you own the fireplace. This covers: combustion chamber,ranted against defects for as long as you own the fireplace. This covers: combustion chamber,
ranted against defects for as long as you own the fireplace. This covers: combustion chamber,
ranted against defects for as long as you own the fireplace. This covers: combustion chamber,ranted against defects for as long as you own the fireplace. This covers: combustion chamber, heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakageheat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage
heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage
heat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakageheat exchanger, stainless steel burner, phazer™ logs and embers, ceramic glass (thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled components and aluminumonly), gold plated parts against tarnishing, porcelainized enamelled components and aluminum
only), gold plated parts against tarnishing, porcelainized enamelled components and aluminum
only), gold plated parts against tarnishing, porcelainized enamelled components and aluminumonly), gold plated parts against tarnishing, porcelainized enamelled components and aluminum extrusion trims.extrusion trims.
extrusion trims.
extrusion trims.extrusion trims.
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,
Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,Electrical (110V and millivolt) components and wearable parts such as blowers, gas valves,
thermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly arethermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are
thermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are
thermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly arethermal switch, switches, wiring, remote controls, ignitor, gasketing, and pilot assembly are covered and covered and
covered and
covered and covered and the limited warranty.the limited warranty.
the limited warranty.
the limited warranty.the limited warranty.
Labour related to warranty repair is covered free of charge during the first year. Repair work,Labour related to warranty repair is covered free of charge during the first year. Repair work,
Labour related to warranty repair is covered free of charge during the first year. Repair work,
Labour related to warranty repair is covered free of charge during the first year. Repair work,Labour related to warranty repair is covered free of charge during the first year. Repair work,
however, requires the prior approval of an authorized company official. Labour costs to thehowever, requires the prior approval of an authorized company official. Labour costs to the
however, requires the prior approval of an authorized company official. Labour costs to the
however, requires the prior approval of an authorized company official. Labour costs to thehowever, requires the prior approval of an authorized company official. Labour costs to the account of account of
account of
account of account of be done through an authorized be done through an authorized
be done through an authorized
be done through an authorized be done through an authorized
NAPOLEONNAPOLEON
NAPOLEON
NAPOLEONNAPOLEON
NAPOLEONNAPOLEON
NAPOLEON
NAPOLEONNAPOLEON
will provide replacement parts free of charge during the first year ofwill provide replacement parts free of charge during the first year of
will provide replacement parts free of charge during the first year of
will provide replacement parts free of charge during the first year ofwill provide replacement parts free of charge during the first year of
are based on a predetermined rate schedule and any repair work must are based on a predetermined rate schedule and any repair work must
are based on a predetermined rate schedule and any repair work must
are based on a predetermined rate schedule and any repair work must are based on a predetermined rate schedule and any repair work must
NAPOLEONNAPOLEON
NAPOLEON
NAPOLEONNAPOLEON
dealer. dealer.
dealer.
dealer. dealer.
NAPOLEONNAPOLEON
NAPOLEON
NAPOLEONNAPOLEON
gas fireplace are war- gas fireplace are war-
gas fireplace are war-
gas fireplace are war- gas fireplace are war-
CONDITIONS AND LIMITATIONS
NAPOLEON warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears on the
warranty registration card filed with NAPOLEON -- provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following conditions and limitations:
This factory warranty is nontransferable and may not be extended whatsoever by any of our representatives. The gas fireplace must be installed by a licenced, authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the
product and all local and national building and fire codes.
This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify
this warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel
parts, mechanical breakage of PHAZER™ logs and embers, nor any venting components used in the installation of the fireplace.
NAPOLEON warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During the first 10 years NAPOLEON will replace
or repair the defective parts at our option free of charge. From 10 years to life, NAPOLEON will provide replacement burners at 50% of the current retail price.
In the first year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated
in accordance with the operation instructions and under normal conditions.
After the first year, with respect to this President's Limited Lifetime Warranty , NAPOLEON ma y , at its discretion, fully discharge all obligations with respect to this warranty by refunding
to the original warranted purchaser the wholesale price of any warranted but defective part(s).
After the first year, NAPOLEON will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not
covered by this warranty.
Notwithstanding any provisions contained in this President's Limited Lifetime Warranty, NAPOLEON’S responsibility under this warranty is defined as above and it shall not in any event
extend to any incidental, consequential or indirect damages.
This warranty defines the obligations and liability of NAPOLEON with respect to the NAPOLEON gas fireplace and any other warranties expressed or implied with respect to this product,
its components or accessories are excluded.
NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. NAPOLEON will not be responsible for: over-firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting configurations, insufficient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
Any damages to fireplace, combustion chamber, heat exchanger, brass trim or other component due to water, weather damage, long periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON.
The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration card must be returned within fourteen days to register the warranty.
NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.
ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE T O ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD.
WS-415-091 / 06.26.00
INTRODUCTION
5
GENERAL INSTRUCTIONS
THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with
local codes. In absence of local codes, install to the cur­rent CAN/CGA -B149 Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1-1988, and NFP A 54­1988 in the United States. Suitable for mobile home instal­lation if installed in accordance with the current standard CAN/CSA Z240MH Series, for gas equipped mobile homes, in Canada or ANSI Z223.1-1988 and NFPA 54-1988 in the United States.
Purge all gas lines with the glass door of the fireplace removed. Assure that a continuous gas flow is at the burner before installing the door.
Under extreme vent configurations, allow several min­utes (5-15) for the flame to stabilize after ignition.
All horizontal runs must have a minimum 1 inch rise per foot when using Napoleon flexible venting components .
Eight (8") inches is the minimum bend radius allowed for the 7" diameter flexible air liner.
The fireplace and its individual shutoff valve must be dis­connected from the gas supply piping system during any pressure testing of that system at test pressures in ex­cess of 1/2 psig (3.5 kPa). The fireplace must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
When the fireplace is installed directly on carpeting, vinyl tile or other combustible material other than wood flooring, the fireplace shall be installed on a metal or wood panel extending the full width and depth.
If the optional heat circulating blower is installed, the blower must be electrically connected and grounded in accord­ance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70-1996 NATIONAL ELECTRI­CAL CODE in the United States.
Minimum clearance to combustible construction from fireplace and vent surfaces:
sides, back, bottom, and top 0 inches vent pipe 2 inch recessed depth (corner installation) 243/4 inches
*
The first 2 feet of outer 7 inch diameter vent pipe from the appliance must be wrapped in the 1 inch thick insulation sleeve (supplied) as well as having a 1 inch air gap. After the insulation sleeve a 2" air gap must be maintained between the re­maining vent system and combustibles.
**
*
**
FIGURE 39.
GENERAL INFORMATION
FOR YOUR SATISFACTION, ALL BURNER ASSEMBLIES HAVE BEEN TEST-FIRED TO ASSURE THEIR OPERA­TIONS AND QUALITY! Maximum input is 40,000 BTU/h
for natural gas and 36,000BTU/h for propane. When the fireplace is installed at elevations above 4,500ft, and in the absence of specific recommendations from the local au­thority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft. Maximum output for natural gas is 33,200 BTU/hr at an efficiency of 83% with the fan on.
Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. Manifold pressure under flow conditions is 3.5 inches water column for natural gas and 10 inches water column for propane.
This fireplace is approved for bathroom, bedroom and bed­sitting room installations and is suitable for mobile home installation. The natural gas model can only be installed in a mobile home that is permanently positioned on its site and fuelled with natural gas.
NO EXTERNAL ELECTRICITY (110 VOL TS OR 24 VOL TS) IS REQUIRED FOR THE GAS SYSTEM OPERATION. Expan-
sion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
CARE OF GLASS, AND PLATED PARTS
Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. The glass is 3/16" ceramic glass available from your Napoleon / Wolf Steel Ltd. dealer .
Do not substitute materials .
If the door glass should crack or break, do not operate the fireplace. Replace only with a door assembly certified with the fireplace. See DOOR, LOUVRE AND TRIM INSTALLA- TION for removal and replacement details. Clean the glass after the first 10 hours of operation with a recommended gas fireplace glass cleaner. Thereafter clean as required.
Do not clean glass when hot!
If the glass is not kept clean permanent discolouration and / or blemishes may result.
Provide adequate ventilation. Provide adequate acces­sibility clearance for servicing and operating the fire­place. Never obstruct the front openings of the fire­place.
Objects placed in front of the fireplace must be kept a minimum of 48" away from the front face of the unit.
WS-415-091 / 06.26.00
6
FIGURE 1
All horizontal runs must have a 1 inch rise per foot in all cases using Napoleon flexible venting components .
Horizontal runs can have a Simpson Dura-Vent components or Na poleon rigid vent­ing components.
Provide a means for visually checking the vent connec­tion to the fireplace after the fireplace is installed.
Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows . K eep it pulled tight. A 1¼" air gap between the inner and outer liner all around is re­quired for safe operation.
For safe and proper operation of the fireplace follow the venting instruction exactly .
Deviation from the minimum vertical vent length can cre­ate difficulty in burner start-up and/or carboning.
0 inch rise per foot using
VENTING
VENTING LENGTHS
Use only Napoleon or Simpson Dura-Vent Model DV-GS venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air termi­nal locations for either system are set out in this manual and must be adhered to.
If vertical rises greater than 57 inches are necessary, the increased rise must be deducted from the horizontal run. (figures 3, and 5a-c .)
The first 2 feet of outer 7 inch diameter vent pipe from the appliance (or from the unit to the first firestop spacer if under 2 feet) must be wrapped in the 1 inch thick insu­lation sleeve (supplied) as well as having a 1 inch air gap.
Use a firestop when penetrating interior walls, floor or ceiling.
The fireplace must be installed against finished walls . Do
not install against a vapour barrier or exposed insulation. Vent lengths tha t pass through unhea ted spaces (attics,
garages, crawl spaces) should be insulated with the in­sulation wrapped in a protective sleeve to minimize con­densation.
The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged.
FIGURE 2
When using Napoleon venting components, use only the following vent kits: WALL TERMINAL KIT GD222, or 1/12 TO 7/12 PITCH ROOF TERMINAL KIT GD110, 8/12 TO 12/12 ROOF TERMINAL KIT GD11 1, FLA T ROOF TERMINAL KIT GD112 or PERISCOPE KIT GD201 (for wall penetration below grade) in conjunction with the various terminations, use either the 5 foot vent kit GD220 or the 10 foot vent kit GD330. For Simpson Dura-Vent, follow the installation pro­cedure provided with the venting components.
These vent kits allow for either horizontal or vertical venting of the fireplace. The maximum number of 4" flexible con­nections is three horizontally or four vertically (excluding the fireplace and the air terminal connections).
For optimum flame appearance and fireplace performance, keep the vent length and number of elbows to a minimum.
WS-415-091 / 06.26.00
When terminating vertically , the vertical rise is a mini­mum 34 inches and a maxi­mum 40 feet above the fire­place. FIGURE 2.
Do not radius vertical vent rises.
FIGURE 3
A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two sin­gle family dwellings and serves both dwellings. Local codes or regulations may r equire different clear ances .
All horizontal runs must have a minimum 1 inch rise per foot when using flexible venting components.
Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows. K eep it pulled tight. A 1¼" air gap all around between the inner liner and outer stove pipe is required for safe operation. Use a firestop when penetrating interior walls, floor or ceiling.
VENTING OPTION #1
When venting, the horizontal run must be kept to a mini­mum of 10 inches or a maximum of 20 feet. If a 20 foot horizontal run is required, the fireplace must have a mini­mum vertical rise immediately off the fireplace of 57 inches.
FIGURES 4a-c.
7
FIGURE 5
Use the chart on this page to calculate vertical rises for horizontal runs between 3 and 20 feet. FIGURE 5.
When calculating maximum run lengths, include 10 feet for each 90° elbow or 5 feet for each 45° elbow. (DO NOT INCLUDE THE FIRST ELBOW DIRECTLY OFF THE UNIT.)
Only the following Napoleon Vent Kits, used in combina­tion with each other can be used:
GD201, GD222, GD110, GD111 or GD112 (Periscope, Wall
or Roof Terminals)
and
GD220 (5ft vent kit) or/and GD330 (10ft vent kits)
FIGURES 4a - c
VENTING OPTION #2
Use this chart to calculate vertical rise for horizontal run between 1 foot (maximum length when the vertical rise is at its minimum of 1 foot) and 8 feet. FIGURES 6.
VERTICAL
RISE in feet
FIGURES 6
HORIZONTAL VENT RUN
in feet
40 FT MAX 1 FT MIN
8 FT MAX (1 FT MAX)
WS-415-091 / 06.26.00
8
VENTING OPTION #3
Use this chart to calculate vertical rise for horizontal run between 3 feet (maximum length when the vertical rise is at its minimum of 1 foot) and 18 feet. FIGURES 7.
VERTICAL
RISE in feet
18 FT MAX (3 FT MAX)
FIGURES 7
20 FT MAX 1 FT MIN
HORIZONTAL VENT RUN
in feet
VENTING OPTION #4
Use this chart to calculate the vertical rise when using a total of 2 horizontal runs that consist of 8 feet maximum or 2 feet (maximum length when the vertical rise is at its mini­mum of 1 foot) for the first run and a 10 feet maximum or 1 foot (maximum length when the vertical rise is at its mini­mum of 1 foot) for the second run. FIGURES 8.
VERTICAL
RISE in feet
10 FT MAX
(1 FT MAX)
FIGURES 8
20 FT MAX 1 FT MIN
8 FT MAX
(2 FT MAX)
COMBINED HORIZONTAL
WS-415-091 / 06.26.00
VENT RUN in feet
VENTING OPTION #5
Use this chart to calculate the total vertical rise required when the horizontal run is between 18 feet maximum or 3 feet maximum length when the initial vertical rise is at its minimum of 1 foot. FIGURES 9.
9
34 FT MAX (1 FT MAX)
18 FT MAX (3 FT MAX)
COMBINED
VERTICAL
RISE in feet
FIGURES 9
HORIZONTAL VENT RUN
in feet
MOBILE HOME INSTALLATION
In Canada, mobile home installation may be vented hori­zontally or vertically. In the United States, it may only be installed vertically. See "
Air Terminal Installation
The fireplace is equipped with four 1/4" diameter holes located near each corner of the base. For mobile home installations, the fireplace must be fastened in place. Use #10 screws, inserted through the holes in the base to se­cure. It is recommended that the fireplace be secured in all installations.
Vertical Venting
" for installation.
" or "
Horizontal
6 FT MAX 1 FT MIN
WS-415-091 / 06.26.00
10
AIR AIR
AIR
AIR AIR
FIGURE 10
A B C
D E
F
G
TERMINTERMIN
TERMIN
TERMINTERMIN
INSTALLATIONS
AL INSTAL INST
AL INST
AL INSTAL INST
CANADIAN U.S.A.
12 INCHES 12 INCHES
12 INCHES*
18 INCHES** 12 INCHES**
0 INCHES
0 INCHES***
2 INCHES***
12 INCHES
9 INCHES
12 INCHES*
18 INCHES** 12 INCHES**
0 INCHES
0 INCHES***
2 INCHES***
ALLAALLA
ALLA
ALLAALLA
TIONS:TIONS:
TIONS:
TIONS:TIONS:
Clearance above grade, veranda porch, deck or balcony . Clearance to windows or doors that open. Clearance to permanently closed windows. Vertical clearance to ventilated sof fit located above the terminal within
a horizontal distance of 2 feet from the centerline of the terminal. Clearance to unventilated soffit. Clearance to an outside corner wall. Clearance to an inside non-combustible corner wall or protruding
non-combustible obstructions (chimney , etc.). Clearance to an inside combustible corner wall or protruding com-
bustible obstructions ( vent chase, etc.).
H
I
J
K
L
M N O
**
* Recommended to prevent condensation on windows and thermal breakage
** ****
** It is recommended to use a heat shield and to maximize the distance to vinyl clad sof fits.
**** ******
*** The periscope GD-201 requires a minimum 18 inches clearance from an inside corner.
****** ********
**** This is a recommended distance. For additional requirements check local codes.
******** ††
Three feet above if within 10 feet horizontally.
†† ‡‡
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family
‡‡
††††
† † Permitted only if the veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor.
†††† †*†*
†* Recommenced to prevent recirculation of exhaust products. For additional requirements check local codes.
†*†*
WS-415-091 / 06.26.00
3 FEET 6 FEET
12 INCHES
6 FEET
7 FEET‡
12 INCHES††
16 INCHES
2 FEET†*
dwellings and serves both dwellings.
3 FEET**** 3 FEET****
9 INCHES
3 FEET†
7 FEET****
12 INCHES****
16 INCHES
2 FEET†*
Clearance to each side of the centerline extended above the meter / regulator assembly .
Clearance to a service regulator vent outlet. Clearance to a non-mechanical air supply inlet to the building or a
combustion air inlet to any other appliance. Clearance to a mechanical air supply inlet. Clearance above a paved sidewalk or paved driveway located on
public property unless fitted with a heat shield kit GD-301. Clearance under a veranda, porch, deck or balcony . Clearance above the roof. Clearance from an adjacent wall including neighbouring buildings.