Napoleon EPA 1100PL, EPA 1100C, EPA 1400C, EPA 1400PL, 1100C, 1400C, 1400PL Installation And Operating Instructions Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
INSTALLATION AND
OPERATING INSTRUCTIONS
CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 40 C.F. R. PART 60 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PARTICULATE EMISSION STANDARDS BY E.E.M.C THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING
SERVICES TO STANDARDS: CSA B366.2, ULC S627, UL 1482. MODEL 1100 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES.
EPA 1100PL,
1100C, 1400PL, 1400C
LEG MODELS
1
SAFETY INFORMATION
!
WARNING
If the information in these instructions is not followed exactly , a
fi re or explosion may result causing property damage, personal
injury or death. Improper installation, adjustment, alteration,
service or maintenance can cause injury or property damage,
bodily injury or even death. Please read entire manual before
you install and use your appliance.
This appliance has not been tested with an unvented gas log
set. T o reduce risk of fi re or injury , do not install an unvented
gas log set into the appliance.
- This appliance can be very hot when burning.
- Combustible materials such as fi rewood, wet clothing, etc. placed too
close can catch fi re.
- Children and pets must be kept from touching the appliance when it is hot.
- The chimney must be sound and free of cracks. Before installing this unit,
contact the local building or fi re authority and follow their guidelines.
- Operate only with the door tightly closed.
- Burn wood behind the log retainer directly on the fi rebricks.
- Do not use an elevated grate or otherwise raise the fi re.
- At least 14 square inches of outside air must be admitted to the room or
directly to the unit through a 4” diameter pipe.
- This appliance is designed to burn natural wood only. Higher effi ciencies
and lower emissions generally result when burning air dried seasoned
hardwoods, as compared to softwoods or to green or freshly cut
hardwoods.
- Do not start a fi re with chemicals or fl uids such as gasoline, engine oil,
etc.
- Do not burn treated wood, coal, charcoal, colored paper, cardboard,
solvents or garbage.
- Do not let the appliance become hot enough for any part to glow red.
- KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to
achieve heat output rates that exceed design specifi cations can result in
steel distortion and damage.
1400PL Illustrated
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
5.2 DOOR REMOVAL / INSTALLATION (1100PL / 1400PL) 19
5.3 1100C/1400C DOOR REMOVAL / INSTALLATION 19
5.4 1400C CAST LID LEVELLING 20
5.5 DOOR HANDLE INSTALLATION 20
5.6 BRICKS AND BAFFLES INSTALLATION 21
6.1 OPTIONAL BLOWER INSTALLATION 22
6.2 OPTIONAL ASH DRAWER (1100PL/1400PL ONLY) 22
7.1 AIR CONTROL 24
7.2 FIRE EXTINGUISHERS / SMOKE DETECTORS 24
7.3 LIGHTING A FIRE 25
7.3.1 FLASH FIRE 25
7.3.2 EXTENDED FIRE 25
7.4 SMOKING 25
8.1 ASH REMOVAL PROCEDURES 26
8.1.1 APPLIANCES WITHOUT ASH PAN (1100PL/1400PL ONLY) 26
8.1.2 APPLIANCES WITH ASH PAN 26
8.2 CREOSOTE FORMATION AND REMOVAL 26
8.3 RUNAWAY OR CHIMNEY FIRE 27
8.4 CHIMNEY CLEANING 27
8.5 GLASS REPLACEMENT 28
8.6 GASKET REPLACEMENT 28
8.7 CARE OF GLASS 29
8.8 CARE OF PLATED PARTS 29
8.9 WOOD 30
NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.
W415-0762 / B / 11.12.10
1.0 INSTALLATION OVERVIEW
1400PL ILLUSTRATED
Door, see “DOOR AND
HANDLE INSTALLATION”
section.
3
Rating Plate, see
“RATING PLATE
INFORMATION” section.
Blower, see “OPTIONAL
BLOWER KIT
INSTALLATION” section.
Legs, see “LEG
INSTALLATION”
section.
Draft, see “AIR CONTROL”
section.
Ash drawer, see “OPTIONAL
ASH DRAWER KIT” section.
W415-0762 / B / 11.12.10
4
2.0 INTRODUCTION
• THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.
• ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND
IS PROHIBITED.
• Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance
according to operating instructions could cause fi re or injury.
• Before installing this appliance, contact the local building or fi re authority and follow their guidelines.
• This appliance must be installed by a qualifi ed installer.
• Risk of burns. The appliance should be turned off and cooled before servicing.
• Do not let the appliance become hot enough for any part to glow red.
• Do not install damaged, incomplete or substitute components.
• Risk of cuts and abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges
may be sharp.
• Young children should be carefully supervised when they are in the same room as the appliance. Toddlers,
young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if
there are at risk individuals in the house. To restrict access to an appliance or stove, install an adjustable safety
gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
• Clothing or other fl ammable material should not be placed on or near the appliance. Objects placed in front of
the appliance must be kept a minimum of 48” away from the front face of the appliance.
• Due to high temperatures, the appliance should be located out of traffi c and away from furniture and draperies.
• Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot surfaces.
• Even after the appliance is out, the glass and/or screen will remain hot for an extended period of time.
• Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot
surfaces. These screens and guards must be fastened to the fl oor.
• Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.
• Under no circumstances should this appliance be modifi ed.
• This appliance must not be connected to a chimney fl ue pipe servicing a seperate solid fuel burning appliance.
• Do not operate the appliance with the glass door removed, cracked or broken. Replacement of the glass should
be done by a licensed or qualifi ed service person.
• Do not strike or slam shut the appliance glass door.
• Operate only with the doors tightly closed.
• Only doors / optional fronts certifi ed with the unit are to be installed on the appliance.
• Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with all
plastic bags, these are not toys and should be kept away from children and infants.
• If the appliance is not properly installed, a house fi re may result. Do not expose the appliance to the elements
(ex. rain, etc.) and keep the appliance dry at all times. Wet insulation will produce an odour when the appliance
is used.
• The chimney must be sound and free of cracks. Clean your chimney a minimum of twice a year and as required.
• Do not start a fi re with chemicals or fl uids such as gasoline, engine oil, etc.
• Your appliance requires periodic maintenance and cleaning. Failure to maintain your appliance may lead to
smoke spillage in your home.
• Higher effi ciencies and lower emissions generally result when burning air dried seasoned hardwoods, as
compared to softwoods or too green or freshly cut hardwoods. Burning wet unseasoned wood can cause
excessive creosote accumulation. When this is ignited it can cause a chimney fi re that may result in a serious
house fi re.
• This appliance is designed to burn natural wood only. Do not burn treated wood, coal, charcoal, coloured paper,
cardboard, solvents or garbage.
• Burn wood directly on the fi rebricks. Do not elevate grate or otherwise raise the fi re.
• Do not store wood within appliance installation clearances or within the space required for re-fueling and ash
removal.
• Ashes must be disposed in a metal container with a tight lid and placed on a non-combustible surface well away
from the home or structure until completely cool.
• Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance.
Elevated temperatures on the wall or in the air above the appliance can cause melting, discolouration or
damage to decorations, a T.V. or other electronic components.
!
WARNING
3.17B
W415-0762 / B / 11.12.10
2.1 DIMENSIONS
5
B
E
1400PL ILLUSTRATED
2.2 SPECIFICATIONS
Specifi cationsRef1100PL1100C1400PL1400C
FLUE CENTER LINE TO REARC6 1/2” 6 3/4”7 1/2” 6 3/4”
* Figures will vary considerably with individual conditions.
** Wolf Steel Ltd. estimated realistic BTU/h with hardwood logs and regular refueling.
W415-0762 / B / 11.12.10
6
2.3 GENERAL INSTRUCTIONS
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH
LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1 CANADIAN
ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE ANSI/NFPA NO. 70 IN
THIS APPLIANCE HAS NOT BEEN TESTED WITH ANY VENTED OR UNVENTED GAS LOG SET. TO
REDUCE RISK OF FIRE OR PREVENT INJURY, DO NOT INSTALL A VENTED OR UNVENTED GAS LOG
BURNING YOUR UNIT WITH THE ASH DUMP DOOR OPEN OR AJAR CREATES A FIRE HAZARD THAT
MAY RESULT IN DISCOLOURATION TO THE GOLD PLATED DOOR, INTERNAL DAMAGE TO THE
APPLIANCE OR A HOUSE CHIMNEY FIRE.
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
THIS APPLIANCE AND IT’S COMPONENTS ARE DESIGNED TO BE INSTALLED AND OPERATED AS A
SYSTEM. ANY ALTERATION TO OR SUBSTITUTION FOR ITEMS IN THIS SYSTEM, UNLESS ALLOWED
BY THESE INSTALLATION INSTRUCTIONS, WILL VOID THE LISTING AND MAY VOID THE PRODUCT
WARRANTY. IT MAY ALSO CREATE A HAZARDOUS INSTALLATION. READ THROUGH THESE
INSTRUCTIONS THOROUGHLY BEFORE STARTING YOUR INSTALLATION AND FOLLOW THEM
CAREFULLY THROUGHOUT YOUR PROJECT.
!
WARNING
THE UNITED STATES.
SET INTO THE APPLIANCE.
4.7
• Before beginning your installation, consult with your local building code agency or fi re offi cials and
insurance representative to ensure compliance.
• Non-toxic smoke will be emitted during the paint curing process, to help dissipate the smoke open a
window near the appliance.
• Remove any dust or debris off the top of the appliance before fi ring the appliance as the paint will be-
come soft as the appliance heats up and will harden as the appliance cures. To cure the paint on your
appliance burn your appliance moderately hot during the fi rst few fi res.
• To keep the gasket from sticking to the appliance as the paint is curing, periodically open the door
every 5-10 minutes.
• For the fi rst two weeks use generous amounts of fuel and burn the appliance with the damper wide
open for an hour as the appliance goes through a process of eliminating moisture in the steel and fi re-
bricks. The initial heat output will be reduced while the moisture is bring drawn from the appliance and
it will be necessary to build several hot fi res to remove this moisture. DURING THIS PROCESS DO
NOT OVERFIRE THE APPLIANCE. REDUCE THE AMOUNT OF AIR COMING INTO THE APPLIANCE IF THE APPLIANCE OR CHIMNEY BECOMES RED.
W415-0762 / B / 11.12.10
2.4 GENERAL INFORMATION
HOT SECONDARY AIR
FIBRE BRICKS
REFRACTORY
2 SIDES, BACK
& BOTTOM
SECONDARY AIR
PRIMARY AIR
FLUE GLASS
CERAMIC
GLASS
AIR CONTROL
COMBUSTION AIR
INTAKE
OPEN
CLOSED
We suggest that our woodburning hearth products
be installed and serviced by professionals who are
certified in the U.S. by the National Fireplace
Institue® (NFI) as NFI Woodburning Specialists or
who are certified in Canada by
Wood Energy Technical
Training (WETT).
DO NOT OPERATE THIS APPLIANCE WITHOUT THE LEGS INSTALLED.
Y our appliance has been specifi cally designed over many months of research to meet the 1990 U.S.A. EPA particulate
emission standards and have been extensively tested in Canadian and American laboratories. This system is the most
effi cient, simple and trouble free we know and works as follows:
The chimney vent system used on your wood burning appliance should be designed with the least amount of
restriction possible to enable the exhaust products to easily fl ow through it. Chimney vent systems that are
too short or too long can also have an adverse affect on the fl ow of exhaust through it. The wood burning
appliance and chimney vent system also require a suffi cient supply of combustion air not only to support the
combustion in the combustion chamber but to replace the exhaust leaving it so it can fl ow freely up through
the vent system and out into the atmosphere. It is the correct balance of combustion air and the chimney vent
system that will ensure the appliance provides you with its optimum performance.
Combustion air enters through two holes in the bottom covered by a single draft control. Air from the front hole goes up
on either side of the door into a preheating airwash located
across the top and then down the window to feed the fi re
and also to ensure that the glass remains clean. Air from
this hole also feeds directly into the combustion chamber at
hearth level. Secondary air from the rear hole travels up the
back in the secondary air housing to the manifold located at
the top and shoots out laterally to oxidize the gases below
the smoke exit.
!
WARNING
7
The combustion chamber is lined with high temperature
fi rebrick on 2 sides, the back and across the bottom, with a
layer of fi bre baffl es at the top to maintain a high tempera-
ture in the combustion chamber so that gases mixing with
the preheated air from the secondary air manifold tube are
easily ignited and burned. The appliance sides and back are
shielded to direct the heat upwards and forwards into the room.
Be sure to provide suffi cient combustion air. There are many other appliances in your home competing for air such as:
a kitchen range hood, forced air heating devices or a bathroom exhaust fan.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
After extended periods of non-operation such as following a vacation or a warm weather season, the appliance may
emit a slight odour for a few hours. This is caused by dust particles on the fi rebox burning off. Open a window to suf-fi ciently ventilate the room.
CALIFORNIA PROP 65 WARNING:
Use of this product may produce smoke which contains chemicals known to the State of California to cause cancer, birth
defects, or other reproductive harm.
If optional ash drawer is purchased, ensure that the ash dump
door is tightly closed, allow the door to snap shut dislodging anything (ashes or pieces of coal) that may be stuck in the opening.
If you experience smoking problems, you may been to open a door, a window or otherwise provide some method of
supplying combustion air to the appliance.
W415-0762 / B / 11.12.10
8
USING DOUSING DO
DD
OSED.
IR LES
ÀÀ
LA LA
POUR USAGE
UR L’
ÂTRE.
AVERTISSEMEN
VITRE EN CVITRE EN C
E SUR
M
EALCOVE
"B"B"
EST INSTALLEST INSTALL
UÉRE DU
O
SCOMBUSTIBLES
AVEC RACCORD AVEC R
2.5 RATING PLATE LOCATION
For rating plate location,
see “INSTALLATION
OVERVIEW”
LISTED SOLID FUEL BURNING SPACE HEATER /
TESTED TO: / TESTÉ SELON : UL1482 / ULC S627 / CSA B366.2 (DEC 92)
POÊLE À COMBUSTIBLE SOLIDE HOMOLOGUÉ
MODEL / MODÈLE - EPA 1400
14001400L1402
1450
1400C
This illustration is for reference only. Refer to the rating plate on the appliance
for accurate information.
INSTALL AND USE ONL Y IN
ACCORDANCE WITH THE
MANUFACTURER’S
INSTRUCTIONS AND LOCAL
BUILDING CODES.
MINIMUM CEILING HEIGHT:
7FT (2.13m)
HEARTH EXTENSION /
COMBUSTIBLE FLOOR
PROTECTION: IF INSTALLED
ON A COMBUSTIBLE FLOOR,
UNIT MUST BE PLACED ON A
NON-COMBUSTIBLE FLOOR
PROTECTOR EXTENDING 18”
(455mm) IN FRONT AND 8”
(205mm) TO THE SIDES AND
BACK.
CHIMNEY TYPE: MINIMUM 6”
(152mm) DIAMETER
APPROVED RESIDENTIAL
TYPE FOR MOBILE HOME
USE A CHIMNEY LISTED TO
ULC S629 IN CANADA OR UL
103HT IN THE USA.
CHIMNEY CONNECTOR: 6”
(152mm) DIAMETER MINIMUM
24 GAUGE STEEL MINIMUM
CLEARANCE FROM
HORIZONTAL CONNECTOR
AND CEILING 18” (455mm).
DO NOT OBSTRUCT SPACE
UNDER HEATER.
SPECIAL METHODS ARE
REQUIRED WHEN PASSING A
CHIMNEY THROUGH A WALL
OR CEILING. SEE INSTRUCTIONS AND BUILDING
CODES.
DO NOT CONNECT THIS UNIT
TO A CHIMNEY FLUE
SERVING ANOTHER
APPLIANCE.
FUEL: FOR USE WITH WOOD
ONLY. DO NOT USE GRATE
OR ELEVATE FIRE. BUILD
WOOD FIRE DIRECTLY ON
HEARTH.
WARNING: RISK OF SMOKE
SPILLAGE. OPERATE ONLY
WITH DOOR FULLY CLOSED.
REPLACE GLASS ONLY WITH
CERAMIC GLASS.
DO NOT OVERFIRE. IF
HEATER OR CHIMNEY
CONNECTORS GLOW, YOU
ARE OVERFIRING. INSPECT
AND CLEAN CHIMNEY
FREQUENTLY. UNDER
CERTAIN CONDITIONS OF USE
CREOSOTE BUILD-UP MAY
OCCUR RAPIDLY.
OPTIONAL BLOWER KIT:
EP-62, 115V, 60HZ, 0.82AMP.
ROUTE CORD AWAY FROM
UNIT.
DANGER: RISK OF
ELECTRICAL SHOCK.
DISCONNECT POWER
BEFORE SERVICING UNIT.
INSERT: INSTALL AND USE
ONLY IN SOLID FUEL
BURNING FIREPLACES. DO
NOT REMOVE BRICKS OR
MORTAR FROM SOLID FUEL
BURNING FIREPLACE.
INSTALL WITH A POSITIVE
FLUE CONNECTOR AND
FACEPLATE.
POUR INSTALLATION ET
UTILISATION CONFORM
AUX INSTRUCTIONS DU
FABRICANT ET AUX CODES
LOCAUX DU BÂTIMENT.
HAUTEUR DE PLAFOND MINIMAL
7PI (2,13m).
PROLONGEMENT
D’ÂTRE/PROTECTION DU
PLANCHER COMBUSTIBLE: SI
INSTALLÉ SUR UN PLANCHER
COMBUSTIBLE, L’APPAREIL DOIT
ÊTRE PLACÉ SUR UNE PLAQUE
PROTECTRICE INCOMBUSTIBLE
S’ÉTENDANT SUR 18” (455mm)
L’A V ANT ET 8” (205mm) À L ’ARRIÈRE
ET SUR LES CÔTÉS.
TYPE DE CHIMNÉE: DIAMÈTRE
MINIMAL DE 6” (152mm)
APPROUVÉE POUR USAGE
RÉSIDENTIEL. MAISON MOBILE
EMPLOYEZ UNE CHEMINÉE
HOMOLOGUÉE ULC S629 AU
CANADA OU UL 103HT AUX
ÉTA TS-UNIS.
RACCORD DE CHEMINÉE:
DIAMÈTRE DE 6” (152mm) D’ACIER
DE CALIBRE 24 MINIMUM. 18”
(455mm) DE DÉGAGEMENT
MINIMAL ENTRE LE RACCORD
HORIZONTAL ET LE PLAFOND.
NE RIEN ENTREPOSER SOUS
L’APP AREIL.
DES MÉTHODES SPÉCIALES SONT
REQUISES LORSQU’UNE
CHEMINÉE TRAVERSE UN MUR OU
UN PLAFOND. VOIR LES
INSTRUCTIONS ET LES CODES DU
BÂTIMENT.
NE PAS RACCORDER À LA
CHEMINÉED’UN AUTRE APPAREIL.
COMBUSTIBLE: POUR USAGE
AVEC LE BOIS SEULEMENT.
N’UTILISEZ PAS DE CHENET OU NE
SURÉLEVEZ PAS LE BOIS.
RÉLEVEZ PAS LE BOIS.
PRÉPAREZ LE FEU DIRECTEMENT
SUR L’ÂTRE.
R L’
AVERTISSEMENT: RISQUE
AVERTISSEMENT:
D’ÉCHAPPEMENT DE FUMÉE.
D’
TENIR LA PORTE FERMÉE
LORSQUE LE POÊLE FONCTIONNE.
REMPLACEZ LA VITRE PAR UNE
VITRE EN CÉRAMIQUE SEULEMENT.
NE SURCHAUFFEZ PAS
L’APP AREIL. SI L ’APPAREIL OU LES
RACCORDS ROUGEOIENT,
L’APP AREIL SURCHAUFEE.
INSPECTEZ ET NETTOYEZ LA
CHEMINÉE FRÉQUEMMENT. DANS
CERTAINES CONDITIONS, DES
DÉPÔTS DE CRÉOSOTE PEUVENT
SE FORMER RAPIDEMENT.
SOUFFLERIE OPTIONNELLE:
EP-62, 115V, 60HZ, 0,82A. TENEZ LE
CORDON ÉLECTRIQUE LOIN DE
L’APP AREIL.
DANGER: RISQUE DE SECOUSSE
ÉLECTRIQUE. DÉBRANCHEZ AVANT
DE PROCÉDER À L’ENTRETIEN.
ENCASTRÉ: INST ALLEZ ET UTILISEZ
SEULEMENT DANS UN FOYER À
COMBUSTIBLE SOLIDE. NE
RETIREZ PAS DE MORTIER, NI
BRIQUES DU FOYER À COMBUSTIBLE SOLIDE.
INSTALLEZ AVEC UNE GAINE
CONFORME ET UNE PLAQUE DE
RECOUVREMENT.
POUR USAGE
ÂTRE.
CAUTION:
ATTENTION:
WOLF STEEL LTD.
24 Napoleon Rd. Barrie, Ontario L4M 4Y8 Canada
WOLF STEEL USA
103 Miller Drive, Crittenden, Kentucky, USA, 41030
U.S. ENVIRONMENTAL PROTECTION AGENCY
CONTACT LOCAL BUILDING FIRE OFFICIALS ABOUT RESTRICTIONS AND
ÉMENT
INSTALLATION INSPECTION IN YOUR AREA. MODEL 1400 IS SUITABLE FOR USE
IN MOBILE HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT (111KT). A
MINIMUM CLEARANCE OF 18” (457mm) TO THE CHIMNEY CONNECTOR MAY BE
REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
RENSEIGNEZ-VOUS AUPR
SERVICE DES INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONS
D’INSTALLA TION DANS VOTRE RÉGION. LES MODÈ LES 1 400 PE UVENT ÊTRE
INSTALLÉS DANS UNE MAISON MOBILE SI INST ALLÉS CONJOINTEMENT AVEC UNE
PRISE D’AIR EXTÉRIEUR (11 1KT). UN DÉGAGEMENT MINIMAL DE 18” (457mm)
JUSQU’AU RACCORD DE LA CHEMINÉE PEUT ÊTRE EXIGÉ PAR L’AUTORITÉ AYANT
JURIDICTION.
BACK WALL (M/A)
À
B
A
IF THE STOVE IS TO BE INSTALLED ON A COMBUSTIBLE FLOOR, IT MUST BE
PLACED ON AN APPROVED NON-COMBUSTIBLE HEARTH PAD, THAT
EXTENDS 8” (200mm) BEYOND THE STOVE SIDES AND BACK, AND 18”
(455mm) TO THE FRONT.
SI LE POÊLE EST INSTALL
SUR UNE BASE DE PROTECTION INCOMBUSTIBLE CERTIFÉE QUI DOIT DÉPASSER
LES CÔTÉS ETL’AMÉRE DU
(455mm) SUR LE DEVANT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL WITH SINGLE WALL
CHIMNEY CONNECTOR / DÉGAGEMENTS MINIMAUX AUX MATÉRIAUX
COMBUSTIBLES AVEC RACCORD DE CHEMINÉE À PAROI SIMPLE:
MBUSTIBLE
USING DOUBLE W
D’UN CONDUIT DE RACCORDEMENT
*MODEL 1400 MAY MAY BE INSTALLED INTO A MOBILE HOME IN THE UNITED
STATES ONLY.
*LE MODÈLE 1400 NE PEUT ÊTRE INSTALLÉ QUE DANS UNE MAISON
MOBILE AUX ÉTA TS-UNIS SEULEMENT .
ÈS DES AUTORITÉS LOCALES DU BÂTIMENT ET DU
BACK WALL (M/A)
45°
C
SIDE WALL (M/L)
É SUR UN PLANCHER COMBUSTIBLE, IL DOIT ÊTRE PL AC É
LISTED SOLID FUEL BURNING FIREPLACE INSERT /
ENCASTRÉ À COMB USTIBL E SOLIDE HOMOLOGUÉ
TESTED TO / TESTÉ SELON :
ULC S628 / UL 1482
CEILING / PLAFOND
D
FLOOR / PLANCHER
CLEARANCES TO COMBUSTIBLE CONSTRUCTION /
DÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES:
C
B
(MEASURED TO UNIT / À PARTIR DE L’APPAREIL)
A
A SIDE FACING / CÔTÉ 1 IN/PO (25mm)*
B TOP FACING / DESSUS 28 IN/PO (710mm)
C MANTEL / TABLETTE 28 IN/PO (710mm)
D SIDE WALL / MUR LATÉRAL 17 IN/PO (430mm)
*CLEARANCE TO EDGE OF FLASHING / DÉGAGEMENT AU
BORD DE LA FAÇADE
EPI 1402
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,
CLOTHI NG AND FURNITURE
SKIN BURNS.
QUAND L’APP AREIL FONCTIONNE, LA SURFACE DEVIENT
AWAY. CONTACT M
A Y CAUSE
CHAUDE. NE PAS TOUCHER. TENIR LES ENFANTS, LES
VÊTEMENTS ET LES MEUBLES À L’ÉCARTT. LE CON
TA
CT PEUT
CAUSER DES BRÛLURES À LA PE AU.
Certifié conforme à la norme d’émanation de particules de juillet 1992.
EPA1400
DATE CODE / DE DA TE
W385-0401 / G
1400 SERIES RATING PLATE ILLUSTRATED
W415-0762 / B / 11.12.10
3.0 PRE-INSTALLATION PREPARATION
14"
23"
ALCOVE
4 FOOT
MAX
9”6”
3.1 APPLIANCE PLACEMENT
Have an authorized dealer install the appliance. If you install the appliance yourself, have your dealer review
your installation plans and/or installation.
Draw out a detailed plan of the installation including dimensions and verify the dimensions with the requirements listed in this manual.
You may wish to adjust the appliance position slightly to ensure the vent does not intersect with a framing
member. Appliance must be positioned so that no combustibles are within, or can swing within (e.g. drapes,
doors), 48” of the front of the appliance.
3.2 CLEARANCE TO COMBUSTIBLES
!
WARNING
DO NOT INSTALL INTO ANY AREA HAVING A HEIGHT LESS THAN 7 FEET (CEILING OF ENCLOSURE
SIDEWALL (A)12”12”10”10”
SIDEWALL TO FLUE (B)21 3/4”21 3/4”19 3/4”19 3/4”
BACKWALL (C)10”12”6”6”
BACKWALL TO FLUE (D)13 1/2”16 1/2”9 1/2”10 1/2”
CORNER (E)6”6”2”4”
CEILING (F)84”84”84”84”
Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply
with NFPA 211 or CAN/CSA-B365.
3.3 ALCOVE INSTALLATION
1100 series only may be installed, using a listed double wall connector,
such as Security DL6 in Canada, the Simpson Duravent Plus DVL in
the USA or an equivalent double wall connector, into an alcove having
a depth of no more than 4 feet and a height of at least 7 feet.
The minimum clearances are as shown.
A
BACK WALL
SIDE WALL
E
E
F
SIDE WALL
W415-0762 / B / 11.12.10
10
3.4 FLOOR PROTECTION
If the appliance is to be installed on top of a combustible fl oor, it must be placed on an approved non-combusti-
ble hearth pad, that extends 8” beyond the appliance sides and back and 18” to the front. The reduced clearance from the back of the appliance may result in the appliance pad terminating shorter than 8” beyond the
appliance.
K
J
J
I
3.5 OUTSIDE AIR
IF ROOM AIR STARVATION OCCURS BECAUSE THE FRESH AIR INTAKE IS BLOCKED WITH ICE,
LEAVES, ETC., OR BECAUSE THE APPLIANCE DOOR WAS LEFT OPEN, OR DUE TO A STRONG
EXHAUST FAN OPERATING ETC., DANGEROUS FUMES AND SMOKE FROM THE OPERATING APPLI-
The following are signs that a outside air kit may be required:
• When there is combustion present: Wood burns poorly, smoke spills, back-draft takes place and your
chimney does not draw steadily.
• In the winter there is too much condensation on the windows.
MINIMUM FLOOR PROTECTION
FRONT (I)SIDES (J)BACK (K)
CANADA18”8”8”
USA16”8”8”
NOTE: If a section of horizontal chimney connector is used, fl oor protection is
required under the chimney connector and 2” beyond each side.
!
WARNING
ANCE COULD BE DRAWN INTO THE ROOM.
• Opening a window seems to alleviate the above symptoms.
• A ventilation system is installed in the house.
• Other devices are present that exhaust house air.
• The house has tight fi tting windows and/or is equipped with a well-sealed vapour barrier.
A. Connection from the appliance’s air intake to the outside is
mandatory in mobile homes only, either through a hole in the
wall or through the hole in the fl oor to line up with the knock out
in the leg model or the hole in the pedestal base.
B. Use a fresh air kit. Secure the aluminum liner by fl aring the end
once it is inserted through the hole in the base of the leg or
pedestal model. If the air intake is through the fl oor, the hole in
the pedestal back must be covered with sheet metal to avoid
cold air spillage into the room. A cover plate is available from
your Wolf Steel Ltd. dealer. Avoid cutting away fl oor joists, wall
studs, electrical wires or plumbing. Seal around the outside pipe
with insulation to prevent drafts.
C. Attach the rear knockout plate (located inside the ash pan for
shipping purposes).
W415-0762 / B / 11.12.10
3.6 MOBILE HOME
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE
THE APPLIANCE MUST BE PROVIDED WITH OUTSIDE COMBUSTION AIR.
USE A CHIMNEY CERTIFIED FOR WOOD BURNING UL 103 S629, TYPE HT (2100°F).
MODEL 1100PL, 1100C, 1400PL, and 1400C ARE APPROVED FOR INSTALLATION IN MOBILE HOMES
IN THE UNITED STATES ONLY.
!
WARNING
DO NOT INSTALL IN SLEEPING ROOM.
MAINTAINED.
THE APPLIANCE MUST BE BOLTED TO THE FLOOR.
INSTALL ACCORDING TO 24 CFR, PART 3280 (HUD).
11
For specifi c clearances, see “MINIMUM
CLEARANCES TO COMBUSTIBLES” section.
The appliance must be installed between ceiling
joists, with radiation shield and roof fl ashing, so that
the structural strength, insulation and waterproof
qualities of the home are not lessened. Seal with
silicone to maintain a vapour barrier at the chimney
and outside air pipe penetrations.
RAIN CAP
MOBILE HOME
ROOF FLASHING
RADIATION SHIELD
CEILING SUPPORT
TRIM COLLAR
APPLIANCE
BOL TED T O FLOOR
HEARTH PAD
OUTSIDE AIR CONNECTION
THROUGH WALL OR FLOOR
REMOVE TO
ALLOW FOR
TRANSPORATION
W415-0762 / B / 11.12.10
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.