Napoleon EPA 1100, EPA 1100C, EPA 1400, EPA 1400L, EPA 1100L Installation And Operation Instructions Manual

...
INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PAR­TICULATE EMISSION STANDARDS BY E.E.M.C. THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS: CSA B366.2 , ULC S627, ULC S628, UL 1482. MODEL 1100 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES.
INSTALLATION AND OPERATION INSTRUCTIONS FOR
HI-TECH LISTED SOLID FUEL BURNING STOVES AND INSERTS
1
FREE STANDING MODELS EPA 1100, 1100L, 1100C, 1150, 1400, 1400L & 1900 INSERT MODELS EPI 1101, 1401,
WARNING:
Please read this entire manual before you install and use your new room heater. Failure to
follow instructions may result in property damage, bodily injury, or even death.
If this unit is not properly installed, a house fire may result.
FOR YOUR SAFETY
Follow the installation directions. This unit can be very hot when burning. Combustible mate- rials such as firewood, wet clothing, etc. placed too close can catch fire. Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children and animals away when the fireplace is hot. The chimney must be sound and free of cracks. Before installing your unit, contact the local building or fire authority and follow their guidelines.
The door must be kept closed during operation to prevent smoke, embers from entering the room. Burn wood directly on firebricks. Do not use a grate or elevate the fire. At least 14 square inches (90 sq.cm.) of outside air must be admitted to the room or directly to the unit through a 4 inch (10cm.) diameter pipe. This unit is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as com­pared to softwoods or to green or freshly cut hardwoods. Do not start a fire with chemicals or fluids such as gasoline, engine oil, etc. Do not burn treated wood, coal, charcoal, coloured paper, cardboard, solvents or garbage which tend to produce more pollution than wood. Do not let the unit become hot enough for any part to glow red.
KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to achieve heat output rates that exceed design specifications can result in steel distortion and damage.
1402
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
www.napoleonfireplaces.com • ask@napoleon.on.ca
W415-0512 /C 10.02.06
2
TABLE of CONTENTS
PG 2-4 INTRODUCTION
Warranty General Information Care of Plated & Enamelled Parts Care of Glass
5-6 INSTALLATION
Installing the Legs Alcove Installation Stove Installation Chimney Connection Adding Chimney Sections Outside Air Wall Pass-through
6-7 MOBILE HOME
Venting Outside Air
7-8 FIREPLACE INSERT
Prior to Installation Installation into a Masonry Fireplace Installation into a Factory Built Fireplace
8-9 OPTIONAL BLOWER
Stove Models Leg Models Insert Models 1101 Blower Service and Replacement 1401 Blower Service and Replacement 1150 Blower Installation 1150 Features
10-11 FINISHING
Brick Installation Ornamental Trivet Installation Door and Handles Installation Pedestal Trim Installation Optional Ash Drawer Kit
11-13
OPERATION
Achieving Proper Draft Fire Extinguishers and Smoke Detectors Fuel Loading and Burn Cycle Flash Fire Extended Fire Smoking Ash Removal Procedures
13-14
MAINTENANCE
Creosote Formation and Removal Runaway or Chimney Fire Gasket Replacement Door Removal
14 WOOD PILE MAINTENANCE
15-17 REPLACEMENTS
Ordering Replacement Parts Replacement Parts Accessories
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
snoitacificepS
HTDIW)mc56(.ni2/152)mc6.47(.ni8/392)mc17(.ni82)mc56(.ni2/152)mc56(.ni2/152)mc56(.ni2/152
HTPED)mc75(.ni2/122)m
GNIHSALFDNIHEBHTPED )mc45ot24(.ni12ot2/161 )m
OTENILRETNECEULF RAER
EDISOTENILRETNECEULF)mc93.23(.ni4/321)mc93.73(.ni61/1141)mc65.53(.ni41)mc93.23(.ni4/3
LEDOMLATSEDEPTHGIEH)mc48(.ni4/133)mc7.29(.ni2/163)mc45(.ni4/112)mc48(.n
LEDOMTSACTHGIEH)mc27(.ni2/182
LEDOMGELTHGIEH)mc18(.ni23 )mc18(.ni23
)H.W.D
(REBMAHC
YTICAPACf7.1
*DETAEHAERA.XORPPA
)NRUBHGIH(TUPTUOTAEH **
*ERIFWOLNOITARUDsruoH7sruoH7sruo
SKCIRBo/wTHGIEW)gk5.79(sbl512)gk721(sbl082)gk9.38(sbl581)gk311(sbl052)gk311(sbl052)gk921(
SKCIRBFOTHGIEW)gk4.45(sbl011)gk4.45(sbl011)gk4.45(sbl011)gk56(sbl541)gk56(sbl541)gk25(sbl411
*FIGURES WILL VARY CONSIDERABLY WITH INDIVIDUAL CONDITIONS.
** WOLF STEEL LTD. ESTIMATED REALISTIC BTU/H WITH HARDWOOD LOGS AND REGULAR REFUELING.
NOTE: Changes, other than editorial, are denoted by a vertical line in the margin.
W415-0512 / C 10.02.06
,0011LEDOM L0011&C0011
)mc15.61(-.ni2/16)mc1.71(.ni4/36)mc49.72(.ni11)mc50.91(.ni2/17)mc79.31(.n
ni21x81x2/131
)mc13x64x43(.
3t
m50.0(3)f7.1
2t
f0051-006
2
m931-65(
)
UTB000,55UTB000,55UTB000,55UTB000,07UTB000,07UTB000,58
0511LEDOM)TRESNI(1011LEDOM
c8.85(.ni61/332)mc96(.ni72)mc96(.ni72)mc96(.ni72)mc08(.ni2/113
ni21x81x2/131
)mc13x64x43(.
3t
m50.0(3)f7.1
2t
f0051-006
2
m931-65(
)
ni21x81x2/131
)mc13x64x43(.
3t
m50.0(3)f52.2
2t
f0051-006
2
m931-65(
)
H7sruoH9sruoH9sruoH21
&0041LEDOM
L0041
i2/15)mc50.91(.ni2/17
21)mc93.23(.ni4/321)mc93.23(.ni4/321
i4/133)mc45(.ni4/112)mc48(.ni4/133
.ni21x81x81
3x64x64(
)mc1
3t
m681-39(
m60.0(3)f52.2
2t
f0002-0001
2
)
3t
2041/1041LEDOM
)TRESNI(
c73(.ni2/141
.ni21x81x81
)mc13x64x64(
m60.0(3)f0.3
2t
f0002-0001
2
m681-39(
)
0091LEDOM
.ni21x81x2/122
)mc13x64x75(
3t
m80.0(3)
2t
f0053-0001
2
m523-39(
)
sbl582
NAPOLEON products are manufactured under the strict Standard of the World Recognized
ISO 9001 : 2000 Quality Assurance Certificate.
NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON.
NAPOLEON WOOD FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY
The following materials and workmanship in your new NAPOLEON wood fireplace are warranted against defects for as long as you own the fireplace. This covers: combustion chamber, heat exchanger, ceramic glass (thermal breakage only), gold plated parts against tarnishing, porcelainized enamelled components, aluminum extrusion trims ashdrawer, and cast iron castings.
Electrical (110V) components and wearable parts such as blowers, thermal switch, switches, wiring, fire­brick, gasketing, stainless steel baffle retainer, and high temperature paint are covered and NAPOLEON will provide replacement parts free of charge during the first year of the limited warranty.
Labour related to warranty repair is covered free of charge during the first year. Repair work, however, requires the prior approval of an authorized company official. Labour costs to the account of NAPOLEON are based on a predetermined rate schedule and any repair work must be done through an authorized NAPOLEON dealer.
3
CONDITIONS AND LIMITATIONS
NAPOLEON warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or legal entity (registered customer) whose name appears on the warranty registration card filed with NAPOLEON -- provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following conditions and limitations:
This factory warranty is non-transferable and may not be extended whatsoever by any of our representatives.
The wood fireplace must be installed by an authorized service technician or contractor. Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes.
This limited warranty does not cover damages caused by misuse, lack of maintenance, accident, alterations, abuse or neglect and parts installed from other manufacturers will nullify this warranty.
This limited warranty further does not cover any scratches, dents, corrosion or discolouring caused by excessive heat, abrasive and chemical cleaners nor chipping on porcelain enamel parts, nor any venting components used in the installation of the fireplace.
In the first year only, this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions.
After the first year, with respect to the President's Limited Lifetime Warranty, NAPOLEON may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).
After the first year, NAPOLEON will not be responsible for installation, labour or any other costs or expenses related to the reinstallation of a warranted part, and such expenses are not covered by this warranty.
Notwithstanding any provisions contained in the President's Limited Lifetime Warranty, NAPOLEON’S responsibility under this warranty is defined as above and it shall not in any event extend to any incidental, consequential or indirect damages.
This warranty defines the obligations and liability of NAPOLEON with respect to the NAPOLEON wood fireplace and any other warranties expressed or implied with respect to this product, its components or accessories are excluded.
NAPOLEON neither assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this product. NAPOLEON will not be responsible for: over-firing, downdrafts, spillage caused by environmental conditions such as rooftops, buildings, nearby trees, hills, mountains, inadequate vents or ventilation, excessive venting configurations, insuffi­cient makeup air, or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
Any damages to fireplace, combustion chamber, heat exchanger, brass trim or other component due to water, weather damage, long periods of dampness, condensation, damaging chemicals or cleaners will not be the responsibility of NAPOLEON.
The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer. The warranty registration card must be returned within fourteen days to register the warranty.
NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim.
ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD.
W415-0512 /C 10.02.06
4
GENERAL INFORMATION
Except for their different depths, models 1100, 1150, 1400, 1900 and the fireplace inserts 1101, 1401, and 1402 are identical and use the same burning principles. They were specifically designed over many months of research to meet the 1990 U.S.A. EPA particulate emission standards and have been extensively tested in Canadian and American laboratories. This system is the most efficient, simple and trouble free we know and works as follows: Combustion air enters through two holes in the bottom covered by a single draft control. Air from the front hole goes up on either side of the door into a preheating airwash located across the top and then down the window to feed the fire and also to ensure that the glass remains clean. Air from this hole also feeds directly into the combustion cham­ber at hearth level. Secondary air from the rear hole travels up the back in the secondary air housing to the manifold located at the top and shoots out laterally to oxidize the gases below the smoke exit. The combustion chamber is lined with high temperature firebrick on 2 sides, the back and across the bottom, with a layer of fibre baffles at the top to maintain a high tempera­ture in the combustion chamber so that gases mixing with the preheated air from the secondary air manifold tube are easily ignited and burned. The stove sides and back are shielded to direct the heat upwards and forwards into the room.
PEDESTAL MODELS ONLY
If the outside air feature of the stove is utilized, you should never experience a shortage of combustion air. If you choose not to utilize outside air and experience draft or smoking problems, you may need to open a door or win­dow.
WARNING: Burning your unit with the ash dump door open or ajar creates a fire hazard that may result in discoloration to the gold plated door, in­ternal damage to the stove or a house and/ or chimney fire.
To ensure that the ash dump door is tightly closed, allow the door to snap shut dislodging anything (ashes or pieces of coal) that may be stuck in the opening.
LEG MODELS ONLY
If you experience smoking problems, you may need to open a door, a window or otherwise provide some method of supplying combustion air to the unit.
CARE OF ALL PLATED AND ENAMELED PARTS
Do not use abrasive cleaners to clean these parts. Buff lightly with a clean dry cloth. Prolonged high temperature burning with the door ajar may cause a permanent rainbowing effect on the lower edge of a gold plated door. Porcelain enamel components must be handled with care. The baked-on finish is "glass". If struck, it will chip. Touch­up paint is available through your Napoleon dealer.
FIGURE 1
Be sure to provide sufficient combustion air. There are many other appliances in your home competing for air such as: a kitchen range hood, forced air heating devices or a bath­room exhaust fan.
Do not connect this unit to a chimney flue serving an­other appliance.
Expansion / contraction noises during heating up and cool­ing down cycles are normal and to be expected. After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles on the firebox burning off. Open a window to suf­ficiently ventilate the room.
CALIFORNIA PROP 65 WARNING: Use of this product may produce smoke which contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
W415-0512 / C 10.02.06
CARE OF GLASS
If the glass is not kept clean permanent discolouration and / or blemishes may result. Normally a hot fire will clean the glass. The most common reasons for dirty glass include; not using sufficient fuel to get the stove thoroughly hot, us­ing green or wet wood, closing the draft so far that there is insufficient air for complete combustion. If it is necessary to clean the glass, use a soft cloth with a nonabrasive cleaner.
DO NOT CLEAN GLASS WHEN HOT!
The glass is very strong but do not let burning fuel rest against it and always close the door gently. If the glass should ever crack while the fire is burning, do not open the door until the fire is out and do not operate the stove again until the glass has been replaced with a new 5mm thick plate of ceramic glass, available from your Napoleon / Wolf Steel Ltd. dealer.
DO NOT SUBSTITUTE MATERIALS.
TO REMOVE THE GLASS: When the unit is cool, open the door and remove the screws and brackets holding the glass in place. Remove all broken glass. Wrap the edges of the new glass with a U-shaped strip of fiberglass gasket, covering 1/4" on each side. Place the glass with the fiberglass gasket in position and replace the brackets and screws. When finished, you should be able to move the glass slightly, horizontally and vertically.
STOVE INSTALLATION
5
INSTALLING THE LEGS
To avoid being damaged during shipping, the stove has been bolted to the pallet and must be unbolted before the stove can be installed.
FIGURE 2A
1. Remove the 4 nuts and washers from the underside of the pallet.
2. Lift the stove up and away from the pallet to clear the threaded studs sticking through the pallet. Place the stove on its back onto a pro­tective surface such as a car­pet or blanket to avoid scratches during leg installa­tion.
FIGURE 2B
3. Remove the four additional nuts from each of the four studs.
4. Use four of the nuts and washers removed above to install the legs as illustrated in FIGURES 2a & 2b.
5. Lift the stove up and gently set down on all four legs. Do not pivot unit up on its legs, as this could result in damage to the legs.
ALCOVE INSTALLATION
Model 1100 only may be installed, using a listed double wall connector, such as Security DL6 in Canada, the Simpson Duravent Plus DVL in the USA or an equivalent double wall connector, into an alcove having a depth of no more than 4 feet and a height of at least 7 feet. The mini­mum clearances are as shown in FIGURE 3.
6"
9"
14"
23"
ALCOVE
FIGURE 3
4 FOOT
MAX.
STOVE INSTALLATION
If the stove is to be installed on a combustible floor, it must be placed on an approved non-combustible hearth pad, that extends 8" (200mm) beyond the stove sides and back, and 18" (455mm) to the front. It must be installed with a minimum height of 7’ between the stove base and the ceiling.
BACK WALL (M/A)
B
A
SIDE WALL (M/L)
FIGURE 4A
BACK WALL (M/A)
45°
C
SIDE WALL (M/L)
FIGURE 4B
SINGLE WALL CHIMNEY CONNECTOR*
1100/1100L/1150 1400/1400L 1900
A 12” (305 mm) 12” (305 mm) 22” (560 mm)
B 10” (254 mm) 12” (305 mm) 12” (305 mm)
C 6” (152 mm) 6” (152 mm) 8” (205 mm)
CLEARANCES CAN BE REDUCED WITH SHIELDING ACCEPTABLE TO LOCAL
*
AUTHORITIES. REDUCED INSTALLATION MUST COMPY WITH NFPA 211 or CAN/CSA-B365.
DOUBLE WALL CHIMNEY CONNECTOR
1100/1100L 1400/1400L 1900
A 10” (254 mm) 10” (254 mm) 22” (560 mm)
B 6” (152 mm) 6” (152 mm) 12” (305 mm)
C 2” (50 mm) 4” (102 mm) 8” (205 mm)
NOTE:CLEARANCES ARE UNABLE TO BE REDUCED FOR THE 1150 BY USING DOUBLE WALL PIPE.
CHIMNEY CONNECTION
A 6” diameter single wall stove pipe, used to connect the stove to the chimney, must be installed with the crimped end toward the stove. This will ensure that the moisture which condenses from the burning wood will flow back into the fire chamber. Each joint in the stove pipe must be se­cured with at least three sheet metal screws. This room heater must be connected to:
1) A chimney complying with the requirements for Type HT chimneys in the Standard for Chimneys, Factory-Built, Resi­dential Type and Building Heating Appliance UL 103, or
2) A code-approved masonry chimney with a flue liner. Vent the stove into a masonry chimney or an approved, insulated solid-fuel stainless-steel chimney with as short and straight a length of six-inch (150mm) diameter smoke pipe as possible. Connection to a masonry chimney must be by a metal or masonry thimble cemented in place. An insulated stainless steel chimney must be supported at the ceiling or roof and its installation must comply with its manufacturer's instructions.
W415-0512 /C 10.02.06
6
THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHT ABOVE THE STOVE.
All horizontal smoke pipe must slope slightly upwards a minimum of 1/4" per foot (6mm/
0.3m) and all connections must be tight and secured by three sheet metal screws equally spaced. An uninsulated smoke pipe shall not pass through an attic, roof space, closet or simi­lar concealed space, or through a floor, ceil­ing, wall or partition, or any combustible con­struction.
DO NOT USE ANY MAKESHIFT MATERIALS DUR­ING INSTALLATION.
1. Move the stove into position with the flue centered, mid­point between two joists to prevent having to cut them. Use a plumb bob to line up the centre.
2. Cut and frame an opening in the roof to provide a 2" clearance between the outside of the chimney and any combustible material.
DO NOT FILL THIS SPACE WITH ANY TYPE OF MATERIAL.
Nail headers between the joist for extra support. Firestop spacers must be placed on the bottom of each framed opening in any floor or ceiling that the chimney passes through.
3. Hold a plumb bob from the underside of the roof to determine where the opening in the roof should be. Cut and frame the roof opening to maintain proper 2" clear­ances.
HEADERS
FIRESTOP SPACER -
FIGURE 5
UNDERSIDE OF JOIST
PEDESTAL MODELS OUTSIDE AIR
If possible connect the air intake at the pedestal's back or bottom to the outside with a 4 inch (100mm) diameter fresh air kit available at your Napoleon/Wolf Steel Ltd. dealer. Follow detailed
PEDESTAL BASE
PEDESTAL BASE
A"
B"
4.5"
instructions under "Mobile Home Outside Air".
FIGURE 7
A (in.) B(in.) 1100 8 5/8" 9 3/4" 1400 11 1/8" 9 3/4" 1900 14 7/8" 9 3/4"
FLOOR AREA BELOW STOVE
WALL PASS-THROUGH
If possible, design the installa­tion so that the connector does not pass through a combustible wall. If during your installation you must pass through a combusti­ble wall, check with your build­ing inspector before you begin. Also check with the chimney con­nector manufacturer for any spe­cific requirements. Consult with your dealer regard-
FIGURE 8
ing special connection components available for use for wall pass-throughs. Use only parts that have been tested and listed for use in a wall pass-through.
MOBILE HOME
PEDESTAL MODEL 1100 IS APPROVED FOR INSTAL­LATION IN MOBILE HOMES IN BOTH CANADA AND THE UNITED STATES. 1150 IS NOT APPROVED FOR MOBILE HOMES. PEDESTAL MODEL 1400 IS APPROVED FOR INSTAL­LATION IN MOBILE HOMES IN THE UNITED STATES ONLY.
WARNING: DO NOT INSTALL IN SLEEPING ROOM. CAUTION: THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED.
BACK WALL
BACK WALL
ADDING CHIMNEY SECTIONS
Add chimney sections, according to the manufacturers installation instructions, securely, to the re­quired height. The chimney must extend, at least, 3 feet above its point of contact with the roof and at least 2 feet higher than any wall, roof or building within 10 feet. FIGURE 6. If your chimney system is enclosed within the attic area, a rafter radiation shield is required.
W415-0512 / C 10.02.06
2 FT. MIN.
FIGURE 6
10 FT.
3 FT. MIN.
6"
10"
SIDE WALL
FIGURE 9
45 °
2"
FIGURE 10
The pedestal base must be firmly bolted to the floor with 1/ 4 inch lag bolts. Minimum clearances to combustibles are as shown in FIGURE 9.
VENTING
Connect the stove to a chimney system using a listed dou­ble wall connector. Use a chimney system listed to ULC S629 in Canada or UL103HT in the U.S.A. The chimney must be installed in accordance with the manufacturer's instructions. Use only specified compo­nents with no substitutions. The chimney and pipe must extend at least 8 feet above the stove and 3 feet above the highest point of the roof. Install a rain cap at the top which will not impede the smoke exhaust. The chimney must be supported at the ceiling or roof so that its weight does not rest on the stove.
SIDE WALL
7
FIGURE 11
It must be installed between ceiling joists, with radiation shield and roof flashing, so that the structural strength, insula­tion and waterproof qualities of the home are not lessened. Seal with silicone to maintain a vapour barrier at the chimney and outside air pipe penetrations.
OUTSIDE AIR
Connection from the stove's air intake to the outside is man­datory in mobile homes only, either through a hole in the wall to line up with the knockout in the pedestal back, or through a hole in the floor to line up with the hole in the pedestal base. Use a fresh air kit. Secure the 4 inch diam­eter aluminum liner by flaring the end once it is inserted through the 4-1/2 inch diameter hole in either the back or base of the pedestal. If the air intake is through the floor, the hole in the pedestal back must be covered with sheet metal to avoid cold air spillage into the room. A cover plate is available from your Wolf Steel Ltd. dealer. Avoid cutting away floor joists, wall studs, electrical wires or plumbing. Seal around the outside pipe with insulation to prevent drafts.
Attach the rear knockout plate (lo­cated inside the ash pan for shipping purposes).
If room air starvation occurs because the fresh air intake is blocked with ice, leaves, etc., or because the stove door was left open, or due to a strong exhaust fan operating etc., dangerous fumes and smoke from the operating stove could be drawn into the room.
FIREPLACE INSERT
Your EPI 1101 and 1401/1402 insert firebox is the exact duplication of the clean-burning technology found in all Na­poleon EPA certified freestanding stoves and in particular that of the EPA 1100 and 1400. External modifications have been made to allow its installation as a "functional fireplace insert" with a heat circulating blower system and a means of enclosing the solid fuel burning fireplace cavity for greater heating efficiency. The EPI 1101 insert must be installed into a solid fuel burning fireplace that is at least 16 1/2 to 21 inches deep, 28 1/2 inches wide and 21 1/2 inches high with an approved lined chimney at least 15 feet high (4.6m). Your EPI 1401/1402 fireplace insert must be installed only into a solid fuel burning fireplace that is at least 14 inches deep 26 inches wide and 22 inches high with an approved lined chimney at least 15 feet high (4.6m). This minimum
recess can only be achieved if the opening height is sufficient enough to allow the connector to fit under the noncombustible facing. The fireplace and chimney must be constructed in
accordance with all national and local building code stand­ards.
HINT FOR INSTALLING PORCELAIN ENAMEL INSERTS:
Ensure the base of the porcelain side panels are protected from rubbing against the hearth when sliding your insert into the masonry fireplace.
PRIOR TO INSTALLATION
Clean all ashes out of the inside of the fireplace. Make sure that the chimney and fireplace are free of cracks, loose mortar, creosote deposits, blockage or other signs of deterioration. If necessary, have any repair work done by a qualified professional before installing
the insert. Do NOT remove bricks or mortar from the fireplace. In case of an outside air inlet or ash dump, fill with fiberglass insu­lation. Adhere to minimum clearances as shown in FIGURE
12.
Do NOT place any com­bustible materials (furni­ture, firewood, etc.) within 48 inches in front or 36 inches at the side of the insert.
Combustible material must not protrude more that 1" to the side of the insert or between the mantle and the top of the insert.
17"
28" TO MANTLE
FIGURE 12
COMBUSTIBLE PROTRUDING SIDE FACINGS
INSTALLATION INTO A MASONRY
FIREPLACE
1. Remove the fireplace damper or fasten it permanently open. * We recommend the following method of sealing off the damper area around the liner.
2. *Measure the throat of the fireplace and mark this shape on a piece of 24 gauge sheet metal (flue cover); cut a six­inch (6.75”) hole to lie directly below the fireplace flue opening. Allow two inches of material for a flange on all sides and cut to these measurements. Bend down the flanges. If you have never done this before, it might be a good idea to make a cardboard pattern and test it first. Fasten this flue cover in position as high as possible with two masonry screws per side through the flanges into the fireplace. FIGURE 13.
DAMPER
REMOVED OR
FASTENED
OPEN
FLUE CONNECTOR
FIGURE 13
In Canada: Install a listed 6 inch diameter flexible stain- less steel liner from the top of the chimney to the insert flue collar. Attach a stainless steel liner connector or elbow to the liner and insert onto the flue collar. Fasten with three screws. Secure the top of the liner to the chimney cap us­ing a liner support and chimney flashing. Cap the top of the chimney liner assembly using an approved rain cap.
MODEL 1401 Illustrated
LISTED CHIMNEY LINER
2" FLANGE
FLUE COVER INSTALLATION
W415-0512 /C 10.02.06
8
In the United States: While it is not required, it is rec- ommended that a chimney liner be installed that is con­tinuous from the insert to the top of the chimney, particu­larly when the insert is installed in a basement. For this type of connection, use the "In Canada" installation instruc­tions above.
In the United States, continued:
If a continuous liner is not installed, a "direct flue connec­tion" must be made. The direct flue connection requires a non-combustible connector that extends from the insert into the chimney flue liner and also that the installed flue cover be sealed below the entry point of the connector to prevent dilution of combustion products in the chimney flue with air from inside the house. Cap the top of the chimney using an approved rain cap. 1401/1402 INSERT MODEL An optional low clearance flue connector is available to facilitate hook up into a tight fitting fireplace. Consult your local dealer for details. The following installation requirements must be observed when installing solid fuel burning inserts into factory built fireplaces.
INSTALLATION INTO A FACTORY
BUILT FIREPLACE
1. The factory built fireplace must be listed per UL 127 or ULC S610.
2. Clearances to any combustible material surrounding this insert as identified in Figure 10 must be followed. These clearance requirements supersede any pre-exist­ing facing material clearances listed for the factory built fireplace.
3. Installation must include a full height listed chimney liner meeting HT requirements (2100°F) per 1777 (U.S.) or ULC S635 (Canada). The liner must be securely attached to the insert flue collar and the chimney top.
4. Means must be provided to prevent room air passage to the chimney cavity of the fireplace. This may be accom­plished by sealing the damper area around the chimney liner, or sealing the fireplace front.
5. The air flow within and around the fireplace shall not be altered by the installation of the insert (i.e. no louvres or cooling air inlet or outlet ports are blocked), unless specifi­cally tested as such for each factory built fireplace manu­facturer and model line. (Note - using a louvred face plate (surround) complies with this requirement)
6. Alteration of the fireplace in any manner is not permitted with the following exceptions;
a. external trim pieces which do not affect the operation of the fireplace may be removed providing they can be stored on or within the fireplace for reassembly if the insert is removed. b. the chimney damper may be removed to install the chimney liner.
7. Circulating air chambers (i.e. in a steel fireplace liner or metal heat circulator) shall not be blocked.
8. Means must be provided for removal of the insert to clean the chimney flue.
9. Inserts that project in front of the fireplace must be sup­plied with appropriate support means.
10. A permanent metal warning label must be attached to the back of the fireplace stating that the fireplace must be restored to its original condition for safe use without the insert.
OPTIONAL BLOWER
Drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to pre­vent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy.
Use of the blower increases the output of heat.
STOVE MODELS
Provisions have been made on the stove to install an op­tional blower kit (EP62-1) that comes complete with a vari­able speed switch to turn the blower on and off, as well as adjusting the blower speed. An optional thermostatic sen­sor control kit, EP36, to thermally activate the blower is also available.
LEG MODELS ONLY
Note: if the optional blower ( EP62-1) is installed, the blower guard (W320-0011) is available from your Napoleon dealer.
Attach the mounting bracket to the blower assembly. Then attach the mounting bracket to the back of your stove, push on the variable speed knob and plug into any grounded electrical outlet.
FIGURE 14
INSERT MODELS
The 1401/1402 inserts comes equipped with two blowers, while the 1101 has one blower. These blowers are ther­mally activated. Depending on the intensity of the fire, the blowers will start 15-30 minutes after lighting. The heat sensor for the 1401/1402 is located on the right hand side of the unit and the 1101 has a heat sensor located at the back on the blower access door. When first starting the fire, the sensor may be impeded by a large log or an unevenly burning fire, causing the blowers to cycle on and off. To control this, either build your fire up evenly or turn down the blowers until the right side of the firebox is hot.
1101 BLOWER SERVICE OR REPLACEMENT
1. Turn off all electrical power to the insert. Remove the glass door and set aside in a safe place.
2. Remove the top right side bricks from inside the firebox, 4-#7's and 2-#2's. Then remove the rest of the side and back bricks from the right side of the 1101 insert. It is not nec­essary to remove the bottom bricks.
must be installed. This guard
MOUNTING BRACKET
BLOWER ASSEMBLY
VARIABLE SPEED SWITCH
BLOWER GUARD
GASKET
THERMAL SWITCH
W415-0512 / C 10.02.06
FIGURE 15
9
3. The access panel can be removed by taking out the 8 #10 self taping screws. A 5/16" nut driver will be required to complete this job. Unplug wires from the thermal switch on the panel. See FIGURE 15.
4. Remove the securing wingnut from the blower mounting bracket, slide the bracket to the right and rotate the left side of the assembly out of the cavity to clear the blower motor. Disconnect the two wires from the blower motor. Remove the ground wire from the blower mounting bracket, then the assembly can be taken out of the rear cavity through the access door opening.
5. Remove the 3 screws that hold the blower to the mount- ing bracket. Service or replace the blower as required.
GROUND STUD
WINGNUT
FIGURE 16
SECURING TAB
WIRES
6. Reinstall the blower assem- bly making sure the blower bracket is seated under the se­curing tab. FIGURE 16. Reattach the wire connectors. FIGURE 17.
7. Replace the gasket on the ac­cess door. To replace the ac­cess panel, reverse Step 3 .
8. Replace the bricks into the firebox. Reinstall the door.
1150 BLOWER INSTALLATION
1. Remove the knock-out from the back of the fireplace.
2. Install the blower and housing as shown using the 4 screws supplied.
FIGURE 19
3. Loosen the thermodisc bracket (2 screws) and slide the bracket forward until the thermodisc is touching the rear firebox and secure.
1150 FEATURES
FIGURE 20
FIGURE 17
1401 BLOWER SERVICE OR REPLACEMENT
1. Turn off all electrical power to the insert. Remove the glass door and set aside in a safe place.
2. Remove the two screws from the outer edge of the side panel(s).
3. Push the side panel toward the door and pull away from the insert, releasing the panel from the keyed slot.
4. Service or replace the blower(s) as required.
5. Re-install the side panel(s) by reversing the procedure.
G B
W
FIGURE 18
HEAT
SENSOR
Wood
Storage
(intended for
short term use)
Pot
Fender
LID LIFTER
HOOK
Remove the screw, as illustrated, from the preferred side of the stove rear. Secure the lid lifter hook, as illustrated, facing out to the side, or bend it towards the back.
W415-0512 /C 10.02.06
10
SIZES
#1. 1-1/4" x 4"-1/2 x 9"
#2. 1-1/4" x 3" x 9"
#3. 1-1/4" x 4-1/2" x 4-1/2"
#4. 1-1/4" x 4-1/2" x 9"
#5. 1-1/4" x 2-1/2" x 4-1/2"
#6. 1-1/4" x 1-1/2" x 4-1/2"
#7. 1-1/4" x 4-1/2" x 9"
* (light weight)
#8. 1-1/4" x 2-1/4" x 9"
#9. 1-1/4" x 2-1/4" x 6-1/8"
#10. Fibre baffle - 9” x 1” x 12”
#11. Fibre baffle - 9” x 1” x 16 1/2”
#12. Fibre baffle - 9” x 1” x 9 3/4”
#13. Fibre baffle - 9” x 1” x 9 3/4”
BACK
SIDES
TOP
FLOOR
FRONT
FINISHING
1100/1100C/ 1101 1400/1400L 1401 1900
1100L/1150
4-#1 4-#1 4-#1 4-#1 4-#7* 2-#4 2-#4 2-#4 2-#4 2-#2
8-#1 8-#1 12-#1 12-#1 12-#7* 2-#3 2-#3 2-#3
2-#4
(notched)
2-#10 2-#10 2-#11 2-#11 2-#12
2-#13
3-#1 4-#1 5-#1 6-#1 7-#7* 2-#2 2-#2 2-#2 2-#2 2-#2 1-#5 1-#5 1-#5 1-#6 1-#6 1-#6
2-#2 2-#2 2-#2 2-#2 2-#2 1-#8 1-#8 1-#8 1-#8 1-#8 1-#9 1-#9 1-#9 1-#9 1-#9
10
10
MODEL 1100/1100C/1100L/1150
- FIGURE 21
11
11
MODEL 1400 / 1400L -
FIGURE 23
10
10
MODEL 1101 - FIGURE 22
MODEL 1401- FIGURE 24
MODEL 1900 - FIGURE 25 BRICK RETAINER DETAIL - TYPICAL
W415-0512 / C 10.02.06
AREA CIRCLED ON EACH FIGURE INDICATES THE
BRICK RETAINER DETAIL
11
BRICKS AND BAFFLES INSTALLATION
With stove and chimney installation completed, move the bricks into place by working as illustrated for your unit on page 10.
1. Install two or three courses of brick on both sides of the unit. Install two courses on the back wall. Install the final course of bricks on the back wall. These bricks are held in place by a brick retainer. Before installing the bricks, loosen the screw holding the retainer and ensure that it has been moved forward. Insert the final two bricks behind the re­tainer and while still holding the bricks in place, slide the retainer snugly into place. Retighten the screw.
2.
1900 only:
Place the stainless steel support onto the top row of the bricks as illustrated on page 10. Pivot the 2 piece baffle up and onto the support, then slide them over and onto the flange of the manifold. En­sure that the overlaps are interlocked to close the gap. Push the baffles to the rear of the firebox. Repeat for the opposite side.
3. Carefully pivot fibre baffle up onto the top of the side brick. Slide it over onto the flange of the manifold.
Ensure that the top baffles are pushed all the way to the rear of the firebox, leaving a minimum of a 1 inch gap along the front. This will allow the flue gases to escape the firebox.
4. Install the bottom bricks, working from the back of the unit.
5. Install the 2 bricks along the front.
NOTE: DO NOTE OPERATE IF BAFFLE AND MANIFOLD SHEILD ARE NOT IN POSITION
ORNAMENTAL TRIVET INSTALLATION
Insert the ornamental trivet into the space on the stove top.
TRIVET
FIGURE 26
DOOR AND HANDLE INSTALLATION
Hang the door using the hinge pins supplied. Twist the large wire handle over the end of the handle rod.
Twist the smaller wire handle over the end of the air damper rod be­low the door. Install ash pan pull handle using screws and washers.
FIGURE 27
See FIGURE 26.
PEDESTAL TRIM INSTALLATION
Ensure that the pedestal surfaces are clean and dry; peel the protective backing from the trim adhesive. In­sert one end of the brass trim into one of the slots located in the ped­estal and pressing firmly, proceed around to the other slot. Cut trim to size. Attach the rear knockout plate (located inside the ash pan for ship­ping purposes).
FIGURE 28
OPTIONAL ASH DRAWER KIT
Models 1100L / 1400L Only: Provisions have been made on the stove to install an optional ash drawer kit. The EPAD­KT kit allows for convenient removal of excess ash. This kit can be purchased through your Napoleon Dealer.
FIGURE 29
OPERATION
CAUTION: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or ‘freshen up’ a fire in this heater. Keep all such liquids well away from the heater while it is in use. Objects placed in front of the fireplace should be kept a minimum of 5” from the front face.
Your Napoleon EPA listed product is a Hi-Tech unit, de­signed with the most advanced technology. The unit is ex­tremely airtight. It has an exclusive direct outside air supply (optional kit), a safety feature designed to prevent spillage, and to keep your house free of carbon monoxide, in case of a downdrafting chimney or an internal negative pressure. The first fire(s) in your unit will be difficult to get going and keep going with little amount of heat being generated. This is a result of the moisture being driven out of the fire brick. Allow 30 to 40 hours of hot fires ( temperatures in excess of 500°F - 600°F) before your unit will perform normally. Dur­ing the break-in period (the first 2 or 3 fires) create only small, hot fires using kindling; this will allow the firebrick to cure. Do not be alarmed if small hairline cracks develop in the firebrick. This is a normal occurrence and does not pose a safety hazard. The paint may also smell a little for the first few fires as it cures and you may wish to open a door or window to alleviate the smell. To start, a brisk fire is required. Place loosely crumpled paper on the floor of the stove and cover with dry kindling. Open the draft control fully by pulling the lever forward. Light the paper and leave the door slightly ajar (one inch) until all kindling is burning. To maintain a brisk fire, a hot coal bed must be established and maintained. Slowly add larger wood (2x4 size pieces). Lay the pieces lengthwise from side to side in the hot coal bed with a shallow trench between, so that the primary air can flow directly into this trench and ignite the fuel above. When the fire seems to be at its peak, medium sized logs may be added. Once these logs have caught fire, carefully close the door. (Closing the door too quickly after refueling will reduce the firebox temperature and result in an unsatisfac­tory burn.) Remember it is more efficient to burn medium sized wood, briskly, and refuel frequently than to load the fireplace with large logs that result in a smouldering, inef­ficient fire and dirty glass. As soon as the door is closed, you will observe a change in the flame pattern. The flames will get smaller and lazier be­cause less oxygen is getting into the combustion chamber. The flames, however, are more efficient. The flames will re­main lazy but become larger again as soon as the firebricks have been heated thoroughly and the chimney becomes heated and provides a good draft. At this point, the roaring fire that you see when the door is opened is wastefully drawing heated room air up the chimney -- certainly not desirable. Always operate with the door fully closed once the medium sized logs have caught fire.
W415-0512 /C 10.02.06
12
You can now add larger pieces of wood and operate the stove normally. Once the stove/insert is entirely hot, it will burn very efficiently with little smoke from the chimney. There will be a bed of orange coals in the firebox and secondary flames flickering just below the top firebrick. You can safely fill the firebox with wood to the top of the door and will get best burns if you keep the stove pipe temperatures be­tween 250 degrees Fahrenheit (120 degrees Celsius) and 450 degrees Fahrenheit (270 degrees Celsius). A surface thermometer will help regulate this.
Without a stove thermometer, you are working blindly and have no idea of how the stove is operating! A stove thermometer offers a guide to performance.
Can't get the fire going? Use more kindling and paper. Assuming the chimney and vent are sized correctly and there is sufficient combustion air, the lack of sufficiently dry quantities of small kindling is the problem. Thumb size is a good gauge for small kindling diameter. Can't get heat out of the unit? One of two things may have happened. The stove/insert door may have been closed prematurely and the unit itself has not reached optimum temperature. Reopen the door and/or draft control to re­establish a brisk fire. The other problem may have been wet wood. The typical symptom is sizzling wood and mois­ture being driven from the wood.
ACHIEVING PROPER DRAFT
Draft is the force which moves air from the firebox up through the chimney. The amount of draft in your chim­ney depends on the length and diameter of chimney, lo­cal geography, nearby ob­structions and other factors. Adjusting the draft control regulates the temperature. The draft can be adjusted from a low burn rate with the handle in fully, to a fast burn rate with the handle fully out. Inadequate draft may cause back-puffing into the room through the stove/insert and chimney connector points and may cause plugging of the chimney. Too much draft may cause an excessive temperature in the stove, glowing red stove parts or chimney connectors or an uncontrollable burn which can lead to a chimney fire or permanent dam­age to the unit. Do not operate your stove/insert for longer than 30 min­utes with the draft control on "HIGH" (fully open).
ASH FENDER
FIGURE 30
1
5
3
2
4
HIGH
LOW
* NOTE: 1100C/1150 and
optional EPA Leg Models ash pans are not equipped with a cover or rear folding handle.
TO OPEN:
PULL AND ROTATE
FIRE EXTINGUISHERS / SMOKE DETECTORS
All homes with a solid fuel burning fireplace should have at least one fire extinguisher in a central location known to all, and at least one smoke detector in the room containing the fireplace. If it sounds an alarm, correct the cause but do not
deactivate or relocate the smoke detector.
FUEL LOADING AND BURN CYCLE
When loading the stove, ensure that the two upper fibre baffles are not lifted up and off their ledge.
For maximum efficiency, when the stove is thoroughly hot, load it fully to the top of the door opening and burn at a me­dium low setting. Maximum heat for minium fuel (optimum burn) occurs when the stove top temperature beneath the trivet is between 500°F (260°C) and 600°F (315°C). The bricks will be nearly all white and the glass mostly clear. The white­ness of the bricks and the cleanness of the glass are good indicators of your operating efficiency. Not enough heat is produced when only one or two pieces of wood are burned or the wood may not burn completely. A minimum of three pieces are needed to encase a bed of coals that sustains the fire. Loosely stacked wood burns quicker than a tightly packed load. Wood burns in cycles rather than giving a steady output of heat. It is best to plan these cycles around your household routine so that only enough coals are left to start the next load. In the evening, load your stove, at least, a half-hour before bed to ensure a good fire, hot enough to close the draft con­trol for an overnight burn. Burn only dry seasoned wood. It produces more heat and less soot or creosote. Do not burn ocean beach wood. Its salt content can produce a metal eat­ing acid. When refueling open the door slowly to prevent smoke spillage. Use a pair of long gloves (barbecue gloves) when feeding the fire. Because these stoves burn at the front, they are clean and efficient, but they are also very hot and gloves are useful. Keep a small steel shovel nearby to use as a poker and to remove ashes. Do not store the wood within 3 feet (1m) of the stove.
FLASH FIRE
A flash fire is a small fire burned quickly when you don't need much heat. After your kindling has "caught", load at least 3 pieces of wood, stacked loosely. Burn with the draft control fully open or closed only slightly.
EXTENDED FIRE
Load your larger pieces of wood compactly, packed close enough to prevent the flames from penetrating it completely. After approximately 30 minutes, depending on the size of the load, close the draft control completely making sure that the fire is not extinguished.
DO NOT OVERFIRE THE STOVE!
Overfiring can occur by:
a) burning large amounts of smaller wood pieces such as
furniture scraps, skids or treated wood;
b) vigorously burning large loads of wood with the draft con-
trol on "HIGH" (fully open) for long periods of time (one or two hours).
ASH WELL COVER
TO CLOSE:
ROTATE
FIGURE 31
W415-0512 / C 10.02.06
REAR FOLDING HANDLE
PULL HANDLE
13
SMOKING
A properly installed Napoleon unit should not smoke. If yours does, check the following: Has the chimney had time to get hot? Is the smoke passage blocked anywhere in the stove, chimney connector or chimney? Is the room too airtight and the air intake not connected to the outside? Try with a window partly open. Is the smoke flow impeded by too long a horizon­tal pipe or too many bends? Is it a weak draft perhaps caused by a leaky chimney, a cold outside chimney, too large a diam­eter of a chimney, too short a chimney, or a chimney too close to trees or a higher roof? Has a direct flue connection been used rather than a chimney liner continuous from cap
to fireplace flue collar.
ASH REMOVAL PROCEDURES
Allow the ashes in your firebox to accumulate to a depth of two or three inches; they tend to burn themselves up. When the fire has burned down and cooled, remove any excess ashes but leave an ash bed approximately 1 inch deep on the firebox bottom to help maintain a hot charcoal bed.
PEDESTAL UNITS WITH ASH PAN
To use your ash pan, pull the ash dump handle forward (FIG­URE 31), rotate approximately 90° counterclockwise to the
open position. Rake the excess ashes into the ash pan. Close the ash well.
NEVER OPERATE YOUR STOVE WITH THE ASH WELL IN AN OPEN POSITION.
This creates a fire hazard that may result in a house/chimney fire, internal damage to the stove or discoloration to the gold plated door (plated finishes are not covered by the warranty). To ensure that the ash well is fully closed, allow the door to snap shut, dislodging anything that may be stuck at the open­ing. Flip the cover up onto the ash pan when transporting the ashes to a closed container with a tight fitting lid for storage.
Carry the ash pan using the front and back handles.
* FIGURE 31.
UNITS WITHOUT ASH PAN
Since these models have no ash pan, shovel some ashes out through the door into a metal container with a tight fitting lid. Leave an ash bed approximately 1 inch deep on the fire­box bottom to help maintain a hot charcoal bed.Keep the closed container on a noncombustible floor or ground, well away from all combustible materials. The ashes should be retained in the closed container until all cinders have thor­oughly cooled. Cold wood ashes can be used on the garden or in the compost.
FIGURE 32
GASKET
LEG UNITS WITH ASH PAN
1. To remove the ashes, clear the ash away from the ash plug.
2. Remove the ash plug. It is recommended to use a poker.
3. Rake the excess ash into the ash drawer.
Do not overfill the ash drawer. Ash should not accumu­late higher than the sides of the drawer.
4. Before removing the drawer, ensure that the area around the ash opening is clean. Tap the ash from the chute into the drawer, then place the ash plug back over opening.
Never operate your stove with the ash plug removed.
MANIFOLD
SHIELD
MAINTENANCE
Check your chimney and chimney connector for creosote and soot buildup weekly until a safe frequency for cleaning is estab­lished. If accumulation is excessive, disconnect the stove and clean both the chimney and the stove. You may want to call a professional chimney sweep to clean them. Both have to be cleaned at least once a year or as often as necessary. Remove fibre baffles and clean above them once a year. Re­place any broken bricks.
CREOSOTE FORMATION AND REMOVAL
When wood is burned slowly, it produces tar and other or­ganic vapours which combine with expelled moisture to form creosote. These vapours condense in the relatively cooler chimney flue of a slow burning fire and when ignited, make an extremely hot fire. So, the smoke pipe and chimney should be inspected monthly during the heating season to deter­mine if a buildup has occurred. If creosote has accumulated it should be removed to reduce the risk of a chimney fire.
RUNAWAY OR CHIMNEY FIRE
Runaway fires can be the result of three major factors:
1. Using incorrect fuel, or small fuel pieces which wood
normally be used as kindling.
2. Leaving the door ajar too long and creating extreme
temperatures as the air rushes in the open door.
3. Burning your stove with the ash dump door open.
SOLUTIONS:
1. Do not burn treated or processed wood, coal,charcoal,
coloured paper or cardboard.
2. Be careful not to over-fire the unit by leaving the door open too long after initial start-up. A thermometer on the chimney connector and/or stove top helps.
3. Always operate the stove with the ash well in a closed
position.
WHAT TO DO IF A RUNAWAY OR CHIMNEY FIRE
STARTS
1. Close the door and draft fully.
2. Call local fire department.
3. Examine flue-pipes, chimney, attic, and roof of the
house, to see if any part has become hot enough to catch fire. If necessary spray with a fire extinguisher or water from a garden hose.
4. Do not operate the stove again until you are certain the chimney and its lining have not been damaged.
GASKET REPLACEMENT
At the end of each burning season inspect the shield and gasket below the manifold for warping or deterioration. Replace if necessary. Both are held to the manifold with machine screws. The shield and the 1/8" fibre cloth gasket are available from your Wolf Steel Ltd. dealer. See FIGURE
32. At this time also check that the door gasket is not worn or loose. Replace with 3/8" high density fiberglass rope if necessary. The airwash gasket and shield above the door should also be inspected and replaced if deteriorated
NOTE: DO NOT OPERATE UNIT IF GASKET, MANIFOLD SHEILD OR FIBRE BAFFLE IS DETERIOTATED OR MISSING.
W415-0512 /C 10.02.06
14
DOOR REMOVAL (1100C ONLY)
1. Remove cast top.
2. Pull pin from top door hinge. It is important to hold the door while removing the pin. Pivot the door to clear the top door hinge. Lift the door off of the lower pin. Do not pivot the door any further than necessary.
WOOD PILE
MAINTENANCE
Burn only dry, clean unpainted wood that has been seasoned. It produces more heat and less soot or creosote. Freshly cut wood contains about 50% moisture while after proper sea­soning only about 20% of the water remains. As wood is burned, this water boils off consuming energy that should be used in heating. The wetter the wood, the less heat is given off and the more creosote is produced. Both hardwood and softwood burn equally well in this stove but hardwood is denser, will weigh more per cord and burn a little slower and longer. Firewood should be split, stacked in a manner that air can get to all parts of it and covered in early spring to be ready for burning that fall. Dry firewood has cracks in the end grain. Cut the wood so that it will fit horizontally, front to back, making for easier loading and less of a likelihood that the wood will roll onto the glass. Ideal lengths of wood are approximately 12" for EPA 1100, 1100C, 1100L, 1150 and 1101, 16 1/2" for EPA 1400, 1400L and 1401, and 21" for EPA
1900.
DO'S
1. Build a hot fire
2. Use only dry wood.
3. Several pieces of medium sized wood are better than a few big pieces.
4. Clean chimney regularly.
5. Refuel frequently using medium sized wood.
6. "Fine Tune" the air settings for optimum performance.
DON'TS
1. Take ash out immediately. Let it accumu­late to a depth of at least one inch. A good ash layer provides for a longer lasting and better burning fire.
2. Burn wet wood.
3. Close the door too soon or damper down too quickly.
4. Burn one large log rather than two or three smaller, more reasonably sized logs.
5. Burn at continually "low setting", if glass door is constantly blackened. This means the firebox temperature is too low.
W415-0512 / C 10.02.06
REPLACEMENTS
15
Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the follow­ing information:
FOR WARRANTY REPLACEMENT PAR TS , A PHOTOCOPY OF THE
ORIGINAL
INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.
REPLACEMENT PARTS
# PART NO. DESCRIPTION
1 W325-0002 SPRING HANDLE - SMALL 2 W325-0007 SPRING HANDLE - LARGE 3* W090-0001 BRICK - # 1 4* W090-0002 BRICK - # 2 5* W090-0004 BRICK - # 4 LEFT 6* W090-0005 BRICK - # 4 RIGHT 7* W090-0015 BRICK - # 7 8* W090-0018 BRICK - # 8 9* W090-0019 BRICK - # 9 10 W715-0073 ASH FENDER TRIM 11* W160-0014 SPRING CLIP FOR ASH FENDER 12 W010-0347 AIRWASH GASKET & SHIELD 13* W570-0007 SCREWS for MANIFOLD & SHIELD 14 GZ551 REPLACEMENT FAN 15 W135-0143
16 W135-0144 17 W135-0145 18 W135-0146 19 W135-0147 20 W325-0040 LID LIFTER
** CAST TOP ** CAST SIDES ** CAST ASHLIP ** CAST LEG ** CAST DOOR
1100 COMPONENTS
21* W090-0003 BRICK - # 3 22* W090-0016 BRICK - # 5 23* W090-0017 BRICK - # 6 24* W018-0077 # 10 FIBRE BAFFLE 25* W200-0077 BLACK TRIVET 26* EP-11MS MANIFOLD GASKET & SHIELD 27* W580-0001 COMPLETE BRICK SET 28* CL28 BLACK CANOPY LOUVRES 29* CL28G GOLD PLATED CANOPY LOUVRES 30 W010-0349 PEDESTAL TRIM 31 KB-35 VARIABLE SPEED CONTROL 32 W010-0243 ASH PAN (NO FRONT PLATE) 33 W325-0011 ASH PAN HANDLE
1400 COMPONENTS
22* W090-0016 BRICK - # 5 23* W090-0017 BRICK - # 6 28* CL28 BLACK CANOPY LOUVRES 29* CL28G GOLD PLATED CANOPY LOUVRES 30 W010-0349 PEDESTAL TRIM 31 KB-35 VARIABLE SPEED CONTROL 32 W010-0243 ASH PAN (NO FRONT PLATE) 33 W325-0011 ASH PAN HANDLE 34* W018-0078 # 11 FIBRE BAFFLE 35* W580-0002 COMPLETE BRICK SET 36* EP-14MS MANIFOLD GASKET & SHIELD 37* GS-330K BLACK TRIVET
1900 COMPONENTS
21* W090-0003 BRICK - # 3 22* W090-0016 BRICK - # 5 23* W090-0017 BRICK - # 6 28* CL28 BLACK CANOPY LOUVRES 29* CL28G GOLD PLATED CANOPY LOUVRES 30 W010-0349 PEDESTAL TRIM 31 KB-35 VARIABLE SPEED CONTROL 32 W010-0243 ASH PAN (NO FRONT PLATE) 33 W325-0011 ASH PAN HANDLE 37* GS-330K BLACK TRIVET 38 W018-0092 # 12 FIBRE BAFFLE 39 W018-0093 # 13 FIBRE BAFFLE 40 W655-0209 BAFFLE SUPPORT BRACKET 41* W580-0003 COMPLETE BRICK SET 42* EP-19MS MANIFOLD GASKET & SHIELD
C/W CORNER BRACKETS
C/W KNOB
C/W KNOB
C/W KNOB
1. MODEL & SERIAL NUMBER OF FIREPLACE
2. INSTALLATION DATE OF FIREPLACE
3. PART NUMBER
4. DESCRIPTION OF PART
5. FINISH
*
IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR
FURTHER
INFORMATION, CONTACT YOUR NAPOLEON
DEALER
.
1101 COMPONENTS
21* W090-0003 BRICK - # 3 24* W018-0077 # 10 FIBRE BAFFLE 26* EP-11MS MANIFOLD GASKET & SHIELD 43* W580-0006 COMPLETE BRICK SET 44 W690-0002 HEAT SENSOR 31A KB-36 VARIABLE SPEED CONTROL
C/W KNOB
1401 COMPONENTS
31 KB-35 VARIABLE SPEED CONTROL C/W KNOB 34* W018-0078 # 11 FIBRE BAFFLE 36* EP-14MS MANIFOLD GASKET & SHIELD 44 W690-0002 HEAT SENSOR 45* W580-0005 COMPLETE BRICK SET 46 W510-0001 5/16" PLUG
1100L COMPONENTS
21* W090-0003 BRICK - # 3 24* W018-0077 # 10 FIBRE BAFFLE 26* EP-11MS MANIFOLD GASKET & SHIELD 31 KB-35 VARIABLE SPEED CONTROL 45* W580-0006 COMPLETE BRICK SET 46 W510-0001 5/16" PLUG
C/W KNOB
1400L COMPONENTS
31 KB-35 VARIABLE SPEED CONTROL C/W KNOB 34* W018-0078 # 11 FIBRE BAFFLE 36* EP-14MS MANIFOLD GASKET & SHIELD 45* W580-0005 COMPLETE BRICK SET 46 W510-0001 5/16" PLUG
1100C COMPONENTS
21* W090-0003 BRICK - # 3 22* W090-0016 BRICK - # 5 23* W090-0017 BRICK - # 6 24* W018-0077 # 10 FIBRE BAFFLE 26* EP-11MS MANIFOLD GASKET & SHIELD 27* W580-0001 COMPLETE BRICK SET 31 KB-35 VARIABLE SPEED CONTROL
C/W KNOB
1150 COMPONENTS
21* W090-0003 BRICK - # 3 22* W090-0016 BRICK - # 5 23* W090-0017 BRICK - # 6 24* W018-0077 # 10 FIBRE BAFFLE 27* W580-0001 COMPLETE BRICK SET 47 W525-0024 POT FENDER 48 W325-0041 ASH DRAWER HANDLE 49 W710-0027 ASH DRAWER 50* W715-0641 PEDESTAL TRIM 51* W290-0101 LID GASKET 52 W135-0234 CAST - FIREBOX TOP 53 W135-0235 CAST - LID 54 W135-0236 CAST - FLUE COLLAR 55 W135-0237 CAST - PEDESTAL BASE 56 W135-0238 CAST - ASH TRAY 57* W325-0040 HANDLE - LID LIFTER
**FOR AVAILABLE PORCELAIN COLOURS,
ADD THESE LETTERS TO THE BASE PART NUMBER: GREEN - F BROWN - N BLACK - K ALMOND - S
W415-0512 /C 10.02.06
16
ACCESSORIES
# PART NO. DESCRIPTION
57 H222G GOLD PLATED DOOR 57 H222 BLACK DOOR 57 H222SS BRUSHED STAINLESS STEEL DOOR
58 H222W BLACK DOOR - EARLY AMERICAN 58 H222GW GOLD DOOR - EARLY AMERICAN 58 H222SSW BRUSHED STAINLESS STEEL DOOR
59 W010-1071 DOOR GLASS W/ GASKET 60* W020-0043 DOOR GASKET 61* W020-0050 GLASS GASKET 62 CISK 63 CISK**A CAST IRON SURROUND KIT, ENAMEL PORCELAIN 64 EPAD-KT ASH DRAWER KIT - LEG MODELS
** CAST IRON SURROUND KIT, PAINTED BLACK
STANDARD ARCH
-
- EARLY AMERICAN
1100 COMPONENTS
65 GS200-G ORNAMENTAL TRIVET 66 EP62-1 VARIABLE SPEED BLOWER 67* W500-0064 FRESH AIR COVER PLATE 68* 111KT OUTSIDE AIR KIT 69* W470-0002 ENAMEL TOUCH UP & BRUSH (
SPECIFY COLOUR)
1400 COMPONENTS
66 EP62-1 VARIABLE SPEED BLOWER 67* W500-0064 FRESH AIR COVER PLATE 68* 111KT OUTSIDE AIR KIT 69* W470-0002 ENAMEL TOUCH UP & BRUSH ( 70* GS-330G GOLD PLATED TRIVET 71* GS-530G ORNAMENTAL TRIVET
SPECIFY COLOUR)
1900 COMPONENTS
66 EP62-1 VARIABLE SPEED BLOWER 67* W500-0064 FRESH AIR COVER PLATE 68* 111KT OUTSIDE AIR KIT 69* W470-0002 ENAMEL TOUCH UP & BRUSH ( 70* GS-330G GOLD PLATED TRIVET 71* GS-530G ORNAMENTAL TRIVET
SPECIFY COLOUR)
1101 COMPONENTS
72 AK-1 ADAPTER KIT FOR CISK 73 EI-900K10 10" FLASHING KIT C/W BULL NOSE TRIM
1401 COMPONENTS
69* W470-0002 ENAMEL TOUCH UP & BRUSH ( 74 EPA335KT LOW CLEARANCE FLUE CONNECTOR 75* EPI-RK SOLID BRASS RAILING KIT 76 AK-2 ADAPTER KIT FOR CISK-A
SPECIFY COLOUR)
1100L COMPONENTS
66 EP62-1 VARIABLE SPEED BLOWER 77 EPA-RK SOLID BRASS RAILING KIT 78* EPLK AIR CIRCULATION CHAMBER LOUVRES (BLACK) 79* EPLG AIR CIRCULATION CHAMBER LOUVRES (GOLD) 80* EPLSS AIR CIRCULATION CHAMBER LOUVRES
81 W320-0011 BLOWER GUARD 82* EP36 THERMOSTATIC SENSOR CONTROL KIT 83 200K TRADITIONAL STEEL LEGS (BLACK) 84 202CK ORNAMENTAL CAST IRON LEGS 84 202CG ORNAMENTAL CAST IRON LEGS (GOLD PLATED) 84 202CSS ORNAMENTAL CAST IRON LEGS
(BRUSHED STAINLESS STEEL)
(BRUSHED STAINLESS STEEL)
1400L COMPONENTS
66 EP62-1 VARIABLE SPEED BLOWER 77 EPA-RK SOLID BRASS RAILING KIT 78* EPLK AIR CIRCULATION CHAMBER LOUVRES (BLACK) 79* EPLG AIR CIRCULATION CHAMBER LOUVRES (GOLD) 80* EPLSS AIR CIRCULATION CHAMBER LOUVRES
81 W320-0011 BLOWER GUARD 82* EP36 THERMOSTATIC SENSOR CONTROL KIT 83 200K TRADITIONAL STEEL LEGS (BLACK) 84 202CK ORNAMENTAL CAST IRON LEGS 84 202CG ORNAMENTAL CAST IRON LEGS (GOLD PLATED) 84 202CSS ORNAMENTAL CAST IRON LEGS
(BRUSHED STAINLESS STEEL)
(BRUSHED STAINLESS STEEL)
1150 COMPONENTS
1 W325-0033 SPRING DOOR HANDLE (LARGE) ­2 W325-0032 SPRING DOOR HANDLE (SMALL) - SATIN CHROME 68* 111KT OUTSIDE AIR KIT 85 EP65 BLOWER KIT
**FOR AVAILABLE PORCELAIN COLOURS,
ADD THESE LETTERS TO THE BASE PART NUMBER: GREEN - F BROWN - N BLACK - K ALMOND - S
SATIN CHROME
W415-0512 / C 10.02.06
17
16
15
12
74
10
33
14
19
30
32
16
44
54
39
17
18
31A
31
53
38
46
77
40
52
58
47
49
85
1
48
55
57
83
84
20
65
59
56
2
62
73727663
64
66
EM3030L-167 zr-2 115V 60Hz 46W Z.P. Ins. ClassB
SEL
073
81
W415-0512 /C 10.02.06
18
Service Performed Special ConcernsDealer Name
Name
Service Technician
Wolf Steel Fireplace Service History
This fireplace must be serviced annually depending on usage.
Date
W415-0512 / C 10.02.06
NOTES
19
W415-0512 /C 10.02.06
20
NOTES
W415-0512 / C 10.02.06
Loading...