will cause the bell, or siren to sound for 2 seconds and also
initiate a test of the battery .
2
Central Station Communication Test
(This test should only be performed on weekends or at a
time designated by your alarm company)
1. Notify Central Station of the impending test.
followed by .This
System Information
Central Station Phone Number: ____________________
Central Station Account Number: ____________________
For Service Call: ____________________
Entry Delay:____________________
Exit Delay:____________________
Alarm Time-out: ____________________
2. Secure all zones to light Ready Light on your keypad.
3. Enter your user code to Arm the system.
4. Violate your alarm by opening a window / door etc.
5. The siren or bell should sound and the system will send
the alarm signals to the Central Station
6. Enter you user code to silence the bell or sounder.
7. Call Central Station to insure that the alarm signals were
received properly.
3
Keypad Controls and Indicators
(
g
www.ealarm.com.my
Key Used to enable
special functions and options. Press
the corresponding Special Function number Option (See Special Functions, Page 11)
Bypass Key Used to
bypass zones. Press
Bypass and the corresponding zone number,
and then Arm system.
Emergency Keys Press
simultaneously to signal
an emergency condition.
Press
$+$
3+3
gency. (Programmable)
4
and then
)+)
for Fire,
for Auxiliary or
for Police Emer-
Numerical Keys 1-9, 0. Used to enter
User Codes, Zone numbers, etc.
99 Key Press to display any present
System troubles. Only available when
99 System Light is lit.
(See System troubles, Page 12)
$50('5($'<
9
),5($&
=21(
=21(=21(=21(
=21(=21(
NAPCO
6<67(0
Armed Li
and will flash when system is in Alarm
Ready Light
and system is ready to be Armed.
99 System Light will light and the Keypad sounder
will pulse to indicate that a system trouble is present.(See System Troubles, Page12)
Fire Alarm Light
sounder will beep when system is in a Fire Alarm
Condition (See Silencing a fire Alarm, Page 8)
AC Light
is present.
Zone Lights
that the corresponding Zone is open, and will
flash to indicate a zone in alarm.
Key - used to reset Fire Zone, clear miss-
entered codes, reset Alarm Memory, etc..
will light when system is Armed,
ht
will light when all zones are secure
will flash and the Keypad
will light to indicate that AC Power
1 through 6) will light to indicate
g
g
g
ARMED
www.ealarm.com.my
READY
SYSTEM
FIRE
AC
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
Arming Your System
Arming Your System When Leaving
1
Before arming your system, make sure the Green
ective zones are secure. If any zones are open, the correspondin
zones before proceedin
2
Enter your user code. The Green
•
If you make a mistake enterin
• If the FIRE light is on, the Fire zone has not been properly reset. Press
(See Silencing a Fire Alarm, page 8)
3
Leave the premises through the Exit/Entry door. If the keypad gives a steady tone you have taken
too long. Enter your code again to disarm system and then re-enter code and leave.
. If any zones cannot be secured, see Bypassing Zones below.
Ready
light will go out, the Red
your code, press
Easy Arm
The Easy Arm feature allows the system to be armed by simply pressing
This will allow the easy arming of the system by someone who is not a regular system user.
Bypassing Zones
If an open zone cannot be immediately fixed it can be left unprotected, or
system is Armed. To Bypass a zone:
1
Press
2
Enter your user code. The Green Ready light will go out and the Red Armed light will light.
3
Leave the premises through the Exit/Entry door.
followed by the zone number to be Bypassed. The Bypassed Zone’s light will flash slowly.
Ready
light is ON. This indicates that all of your prot-
Zone light will be ON. Secure these
Armed
and re-enter the code.
light will light.
followed by .
Bypassed
and enter the code.
, while the rest of the
When the system is subsequently disarmed, all bypassed zones will be reset, ready to be armed again.
If it is necessary to bypass any inoperative zone(s), it is important to have the zone(s) repaired as soon as
possible. A bypassed zone does not provide any protection, compromising system security.