NAPCO NP-PTM Owners Manual

R
333 Bayview Avenue
Amityville, New York 11701 For Sales and Repairs, (800) 645-9445 For Technical Service, (800) 645-9440
© NAPCO 2005
NP-PTM
PROGRAMMABLE TIMER
WI1343A 12/05
DESCRIPTION
The NP-PTM programmable timer is appropriate for various functions that require a timed operation, for example, Siren/ Bell Cut Off Modules, Dialer Delay, Access Control Applica­tions, Guard Tour Supervisory Timers, etc. Some optional functions include: One Shot, Delayed Release, Delayed Op­erate, Delayed Pulse and Pulser/Flasher. Includes a feature that provides a momentary relay activation at the end of a de­sired timing cycle, eliminating the need for using two (2) tim­ers to achieve this function. Another feature cancels (interrupt) the timing cycle and reset the timer if desired.
FEATURES
12 or 24VDC operation is selectable.
Quick and accurate time range adjustment from 1 sec. to
60 min.
LED indicates relay is energized.
Current Draw: Stand-by 3mA, Relay Energized 40mA.
Triggers via positive DC (+) voltage, dry contact closure, or
removal of contact closure.
Form "C" relay contacts are 8 amps at 120VAC/28VDC.
Selectable relay activation at the start or end of the timing
cycle.
One (1) second momentary relay activation at the end of
the timing cycle (eliminates the need to use two (2) timers for this function).
Built-in reset feature which cancels timing cycle.
Repeat (pulser/flasher) mode.
Snap Trac compatible.
DIN Rail Mount version available.
Board dimensions: 76.3mm L x 63.7mm W x 25.0mm H
INSTALLATION INSTRUCTIONS
1. Mount NP-PTM (Multi-Purpose Timer) in desired location or into an enclosure.
2. Set Dip Switch 3 for proper DC Input Voltage- 12VDC switch ON, 24VDC switch OFF
3. Refer to Dip Switch 1 Selection and Dip Switch 2 Selec- tion Tables for desired functions (e.g.: Timing, Trigger, Pulse)
4. Refer to the Terminal Identification Table and Typical Ap- plications (see fig. 8 on reverse) for desired wiring connec­tions.
Note: It is good operating practice to measure and verify DC
input voltage before powering device to ensure proper op­eration.
Note: When triggering via a N.O. (normally open), momen-
tary or maintained trigger, connect the dry contact trigger to Pos (+) and TRG terminals.
When triggering via a N.C. (normally closed), momentary or
maintained trigger, connect the trigger to Neg. (-) and TRG terminals and install a 1K (1,000 ohm) resistor between the Pos (+) and TRG terminals (fig. 8).
DIP SWITCH 1 SELECTION TABLE
DIP# OFF ON
1
Relay energizes at start of
timing cycle.*
2
1-60 minutes timing range.
(adjust trimpot)
3
4
24VDC operating voltage. 12VDC operating voltage.
Timing begins immediately
upon trigger input.
* When relay energizes (LED is on) [N.O. & C] switch from open to close and [N.C. & C] switch from close to open.
DIP SWITCH 2 SELECTION TABLE
DIP# Function/Description
The NP-PTM will go through an initial timing cycle when first
1
powered up unless DIP 1 is OFF. If DIP 1 is OFF, timing can only be initiated via TRG terminal
DIP 2 is OFF puts timer in delayed output mode. Relay will pulse
2
for 1 second at the end of a preset timing cycle. *Dip Switch 1 must be ON for this function.
DIP 3 is OFF selects the pulser/flasher mode. Relay will flip ON
3
and OFF continuously in equally set timed intervals when timer is powered up.
NC
4
TERMINAL IDENTIFICATION
Terminal
Function/Description
Legend
TRG Applying a positive voltage will activate timing cycle.
Trigger voltage range: 7-12VDC at 12 volt setting, 15-24VDC at 24 volt setting.
-, + Connect 12 or 24VDC filtered and regulated voltage. Refer to Dip Switch 1 Selection Table for voltage setting.
N.O., C,
N.C.
Dry form "C" relay contacts are rated 8 amps at 120VAC/28VDC.
Relay energizes at the end of
timing cycle.*
1-60 seconds timing range.
(adjust trimpot)
Timing starts after removal of
trigger input.
NP-PTM Typical Applications
+
CHIME
30
NORTHBROOK,IL.
1
60
-+NOCNC
TRG
Normally open door contacts
-
+
Pos(+)and Neg(-) terminals constant 12 or 24VDC
-
For this application Switch #1 and Switch #4 should be in the OFF position.
DIALER OR
TRANSMITTER
30
NORTHBROOK,IL.
1
60
-+NOCNC
TRG
Normally open swith contacts
For this application Switch #1 and Switch #4 should be in the OFF position.
Pos(+)and Neg(-)
+
terminals constant 12 or 24VDC
-
+ Pos(+)a nd Neg(-)
terminals constant 12
30
NORTHBROOK,IL.
1
60
-+NOCNC
TRG
+
Normally open door contacts
-
or 24VDC
-
For this application Switch #1 should be in the OFF position and Switch #4 should be in the ON position.
Use to bypass
alarm contacts.
Door Contacts
Protective Circuit
30
NORTHBROOK,IL.
1
60
-+NOCNC
TRG
Normally open swith contacts
For this application Switch #1 should be in the OFF position and Switch #4 shound be in the ON position.
Pos(+)and Neg(-)
+
terminals constant 12 or 24VDC
-
Closed Circuit
Zone on Control Panel
30
NORTHBROOK,IL.
1
60
-+NOCNC
TRG
For this application Switch #1 should be in the OFF position and Switch #4 shound be in the ON position.
Delayed Activation of Digital Dialer, Defrost Cycle
Timer, etc...
Use for Door Ajar Alarm,
Use appropriate contacts to reporting devices
Protective Circuit
Pos(+)and Neg(-)
+
terminals constant 12 or 24VDC
-
30
NORTHBROOK,IL.
1
60
-+NOCNC
Normally open triggering device
TRG
For this application Switch #1 should be in the ON position and Switch #4 is not used in this application.
+
Pos(+)and Neg(-) terminals constant 12 or 24VDC
-
BELL OR
SIREN
30
NORTHBROOK,IL.
1
60
-+NOCNC
TRG
For this application Switch #1 should be in the ON and Switch #4 is not used in this application.
+
1K resistor
Circuit Contact
TRG -
For this application a 1K (1,000 ohm) resistor must be installed as shown. (resistor not supplied)
Closed
BELL
OUTPUT
Control Panel 12 or 24VDC
Power
+
-
Supply