R
333 Bayview Avenue
Amityville, New York 11701
For Sales and Repairs, (800) 645-9445
For Technical Service, (800) 645-9440
© NAPCO 2005
NP-LPS6-24VDC
LINEAR POWER SUPPLY
WI1325D 12/05
DESCRIPTION
This variable-purpose power supply is suitable for many different applications for security, access control and CCTV system
accessories that need supplementary power. NP-LPS6-24VDC
power supply/charger converts low voltage AC input into 6VDC
or 12VDC (@ 1.5 amps or 24VDC @ 1A of continuous supply
current). See specifications that follow.
FEATURES
• Dip switch selectable 6VDC-12VDC-24VDC.
• 1.5 amp continuous supply current at 6VDC-12VDC.
• 1A continuous supply current at 24VDC.
• Filtered and electronically regulated output.
• Built-in charger for sealed lead acid or gel type batteries.
• Maximum charge current 300mA.
• Automatic switchover to stand-by battery when AC Fails.
• Circuit breaker battery protection (fused available).
• AC input and DC output LED indicators.
• Extremely compact design.
• Includes battery leads.
Board dimensions: 70mm L x 60mm W x 40mm H
Voltage Output/Transformer Selection Table:
to Voltage Output/Transformer Selection Table).
Use 18 AWG or larger for all power connections (Battery,
DC output).
Keep power limited wiring separate from non-power
limited wiring (115VAC / 60Hz Input, Battery
Wires). Minimum .25” spacing must be provided.
4. Devices to be powered should be connected to terminals
marked [+ DC] and [– DC] carefully observing polarity.
Note: It is important to measure output voltage before con-
necting devices. This helps avoid potential damage.
5. Connect battery to terminals marked [BAT +] and [BAT –]
(battery leads included). Use two (2) 12VDC batteries connected in series for 24VDC operation.
Note: When batteries are not used, a loss of AC will result
in a loss of output voltage.
LED Diagnostics:
Red
(DC)
Green
(AC)
Power Supply Status
ON ON Normal operating condition.
OFF ON No DC output. Short circuit or thermal overload condition.
OFF OFF No DC output. Loss of AC. Discharged or no battery present.
Terminal Identification:
AC
Output Voltage Selector
Transformer
(DIP SWITCH)
24VDC @ 1A continuous
supply current
12VDC @ 1.5 amp con-
tinuous supply current
6VDC @ 1.5 amp con-
tinuous supply current
1. ON
2. ON
1. ON
2. OFF
1. OFF
2. OFF
P-TRF2450
P-TRF1650
P-TRF1650
INSTALLATION INSTRUCTIONS
1. Mount NP-LPS6-24VDC in desired location / enclosure.
2. Unit is factory set for 12VDC. For 6VDC output dip switch
2 off, for 24VDC output dip switch 1 on.
3. Connect proper transformer to terminals marked [AC] (refer
Terminal
Function/Description
Legend
AC Low voltage AC input (refer to voltage output/transformer
+ DC - 6VDC-12VDC @ 1.5 amp continuous supply current.
+ BAT - Stand-by battery connections. Maximum charge rate
selection table).
24VDC @ 1A continuous supply current.
300mA.
APPENDIX LIST
Item Description Dimension Volume Memo
1 Instruction Sheet A4 1
2 Wire 18AWG 22cm 1 Red
3 Wire 18AWG 22cm 1 Black
4 Double Stick Foam Tape 60*20*7mm 1