Namco Controls EA800, EA880 Catalog Page

Single, Double and Triple Pole Hazardous Location
Limit Switches
Butt Contacts
• NEMA Rated for Hazardous Location
• 1 NO-1 NC, 2 NO-2 NC, 3 NO-3 NC
• Bronze, Aluminum or Cast Iron Housing
• Generous Overtravel-EA800 Series
• Heavy Duty Cam Operated-EA800
Limit Switches
Series
• Heavy Duty Rocker T ype-EA880 Series
• Flexibility of Motion, CW and CCW
• Ample Wiring Space
Service Conditions - The Series
EA800/EA880 hazardous location limit switches operate dependably where gases, vapors, and dusts are potential explosion hazards. The switch bodies resist corrosion.
Rugged Construction - Approved spark-proof bronze, aluminum, or cast-iron housings can withstand internal and external gas explo­sions. Silver alloy butt contact arrangement is standard. Wiring space is ample for up to size 12 wire.
Proven Performance - Cycle life is in the millions, when operated at rated current, voltage, and temperature. Standard switches have maximum ambient temperature ratings of 90°C continuous. Switches can be specially ordered with either -40°C or + 150°C capabilities.
Levers Available - A variety of levers for hazardous location limit switches can be ordered from Namco Controls Series EL.
NOTE: Only non-sparking levers should be used in hazardous locations.
Not all models are UL approved.
EA800 Single Pole 1 N.O. - 1 N.C. / Butt Contacts / Cam Action
Angle Angle Angle Angle Angle Angle
Bronze Aluminum Cast Iron Dir. Of Trip Reset Recom. Total Min. Travel Overall Torque Contact
Housing Housing Housing Operation Travel Travel Travel Travel to Maintain Travel (inch lbs) Config.
STANDARD TRAVEL
EA800-10040 EA800-10050 -CW18°14° 30° 90 ° --15A EA800-10041 EA800-10051 - CCW 18° 14° 30° 90 ° --15B EA800-10140 EA800-10150 - CW/CCW 18° 14° 30° 90° --15C
ABCD E F
280
EA800 Double Pole 2 N.O. - 2 N.C. / Butt Contacts / Cam Action
Angle Angle Angle Angle Angle Angle
ABC D E F
Bronze Aluminum Cast Iron Dir. Of Trip Reset Recom. Total Min. Travel Overall Torque Contact
Housing Housing Housing Operation Travel Travel Travel Travel to Maintain Travel (inch lbs) Config.
STANDARD TRAVEL
EA800-20040 EA800-20050 -CW18°14° 30° 90 ° --27D EA800-20041 EA800-20051 - CCW 18° 14° 30° 90 ° --27E EA800-20140 EA800-20150 - CW/CCW 18° 14° 30° 90° --27F
EA800 Triple Pole 3 N.O. - 3 N.C. / Butt Contacts / Cam Action
Angle Angle Angle Angle Angle Angle
ABCD E F
Bronze Aluminum Cast Iron Dir. Of Trip Reset Recom. Total Min. Travel Overall Torque Contact
Housing Housing Housing Operation Travel Travel Travel Travel to Maintain Travel (inch lbs) Config.
STANDARD TRAVEL
EA800-30040 EA800-30050 -CW18°14° 30° 90° --33G EA800-30041 EA800-30051 - CCW 18° 14° 30° 90° --33H EA800-30140 EA800-30150 - CW/CCW 18° 14° 30° 90° --33I
See Operating Levers Section
EA800/EA880
EA880 Single Pole 1 N.O. - 1 N.C. / Butt Contacts / Rocker Type
Angle Angle Angle Angle
ABCD
Aluminum Temperature Dir. Of NEMA Trip Reset Recom. Total Torque Contact
Housing Description Range Operation Type 4 Travel Travel Travel Travel (inch lbs) Config.
STANDARD TRAVEL
EA880-11100 Standard -20C to +90C CW No 10° 8° 13° 38° 13 A EA880-11500 Watertight -20C to +90C CW Yes 10 ° 8° 13° 38° 13 A EA880-11700 Watertight -40C to +90C CW Yes 10 ° 8° 13° 38° 13 A EA880-12100 Standard -20C to +90C CCW No 10° 8° 13° 38° 13 J EA880-12500 Watertight -20C to +90C CCW Yes 10° 8° 13° 38° 13 J EA880-12700 Watertight -40C to +90C CCW Yes 10° 8° 13° 38° 13 J
MAINTAINED
EA880-13100 Standard -20C to +90C CW/CCW No 10° --38°5- EA880-13500 Watertight -20C to +90C CW/CCW Yes 10° --38°5- EA880-13700 Watertight -40C to +90C CW/CCW Yes 10° --38°5-
NEUTRAL POSITION
EA880-17100 Standard -20C to +90C CW/CCW No 7° 6° 7°30' 33° 22 K EA880-17500 Watertight -20C to +90C CW/CCW No 7° 6° 7°30' 33° 22 K EA880-17700 Watertight -40C to +90C CW/CCW No 7° 6° 7°30' 33° 22 K
Limit Switches
Angle Angle Angle Angle
Bronze Temperature Dir. Of NEMA Trip Reset Recom. Total Torque Contact
Housing Description Range Operation Type 4 Travel Travel Travel Travel (inch lbs) Config.
MAINTAINED
EA880-13200 Standard -20C to +90C CW/CCW No 10° --38°5- EA880-13600 Watertight -20C to +90C CW/CCW Yes 10° -38°5-
ABCD
Operational Data Drawing
C
C
A
A
B
D
D
B
2013 West Meeting Street • Lancaster, SC 29720
1-803-286-8491 • FAX: 1-800-678-6263
www.namcocontrols.com
For technical assistance, call 1-800-NAMTECH
281
Single, Double and
Limit
Triple Pole Hazardous Location
EA800/880 Series Drawings
EA800 HAZARDOUS LOCATION
Switches
0.62"
(15.7)
3.64"
(92.5)
Butt Contacts
0.38" (9.7)
0.38" (9.7)
0.406 Three Holes
1.61"
(40.9)
Limit Switches
EA880 ROCKER
48 Serrations Equally Spaced
0.495/0.490 O.D.
1.42"
(36.1)
3.80"
(96.5)
(101.9)
4.00"
(101.6)
4.01"
2.0"
(50.8)
48 Serrations Equally Spaced
0.495/0.490 O.D.
5/16-18 UNC-2B x
0.62 DP. Four Places
B
1.13"
(28.7)
C
A
3.38"
(85.9)
4.60"
(116.8)
3.00"
1.12"
(28.4)
(76.2)
0.31" (7.9)
5.75"
(146.1)
6.37"
(161.8)
282
0.13" (3.3)
1.80"
(45.6)
3/4" - 14 NPT
3.29"
(83.6)
Not to Scale
Switch Conduit Opening NPT Total Height Mounting Height
Type A B C
EA800-1 3/4”-14 6.47” (164.3) 5.42” (137.7) EA800-2 1”-11 1/2 8.50” (215.9) 7.58” (192.5) EA800-3 1 1/4”-11 1/2 10.56” (268.2) 9.67” (245.6)
Dimensions: inches/(mm)
2.24"
(56.9)
2.88"
(73.2)
0.32" (8.1) Dia. Four Places
Contact Configurations
CIRCUIT A
CW
Initial
D B
CCW
C A
CIRCUIT B
CW
D B
Initial
EA800/EA880
CIRCUIT C
CCW
C A
CW
D B
Initial
CCW
C A
CIRCUIT D
CIRCUIT G
CIRCUIT J
CW
CW
CW
H F
D B
M K
H F
D B
D B
Initial
Initial
Initial
CIRCUIT E
CCW
G E
C A
CIRCUIT H
CCW
L J
G E
C A
CIRCUIT K
CCW
C A
CW
CW
CW
H F
D B
M K
H F
D B
D B
Initial
Initial
Initial
CCW
G E
C A
CCW
L J
G E
C A
CCW
C A
CIRCUIT F
CIRCUIT I
CW
CW
H F
D B
M K
H F
D B
Initial
Initial
CCW
G E
C A
CCW
L J
G E
C A
Limit Switches
Common Switch Characteristics
SINGLE, DOUBLE & TRIPLE POLE, HAZARDOUS LOCATION,
BUTT CONTACTS
EA800 EA880
NEMA Enclosure Type 4, 4X, 6, 6P, 7 Class I,
7 Class I, Group C & D, Group C & D, 9 Class II, 9 Class II, Group E, F & G Group E, F & G (Some 4, see
p/n chart)
Housing Material Bronze/Aluminum/
Cast Iron Bronze/Aluminum
(See p/n chart) Ambient Temperature Range* -20°C to +90°C Shipping Weight EA800-1: Al-6 lbs.
Brz-12 lbs. EA800-2: Al-7 lbs. Aluminum: 5 lbs.
Brz-16 lbs. Bronze: 8 lbs. EA800-3: Al-8 lbs.
Brz-19 lbs. Lever Adjustment 7°30’ Increments thru 360° Contacts Butt, Silver Alloy, Form Z
*Some high and low temperature versions available. For EA880, see p/n chart.
For EA800, contact factory.
Continuous Current Rating - Amperes
VOLTAGE AC DC
125 20.0 5.0 250 15.0 1.5 480 10.0 ­600 5.0 -
75-100% Power Factor
2013 West Meeting Street • Lancaster, SC 29720
1-803-286-8491 • FAX: 1-800-678-6263
www.namcocontrols.com
For technical assistance, call 1-800-NAMTECH
283
Loading...